Calorimeter Analysis Tasks, July 2014 Revision B January 22, 2015.

Slides:



Advertisements
Similar presentations
Heat Transfer to Solids in a Flowing Fluid
Advertisements

Conduction Conceptests
Chapter 2 Introduction to Heat Transfer
Application of Steady-State Heat Transfer
ERT 216 HEAT & MASS TRANSFER Sem 2/
Estimation of Convective Heat Transfer Coefficient
UNIT 13 : HEAT 13.1 Thermal Conductivity 13.2 Thermal Expansion.
So Far: Conservation of Mass and Energy Pressure Drop in Pipes Flow Measurement Instruments Flow Control (Valves) Types of Pumps and Pump Sizing This Week:
Heat Transfer Chapter 2.
Chapter 3.2: Heat Exchanger Analysis Using -NTU method
MECHANISM OF HEAT TRANSFER Mode of Heat transfer Conduction Convection
Extended Surface Heat Transfer
Two-Phase: Overview Two-Phase Boiling Condensation
Chapter 2: Overall Heat Transfer Coefficient
Chapter 2: Steady-State One-Dimensional Heat Conduction
Analysis of Simple Cases in Heat Transfer P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Gaining Experience !!!
Thermal Analysis of short bake out jacket version 1 12-Nov-2013.
One-Dimensional Steady-State Conduction
CHE/ME 109 Heat Transfer in Electronics LECTURE 10 – SPECIFIC TRANSIENT CONDUCTION MODELS.
One Dimensional Steady Heat Conduction problems P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi Simple ideas for complex.
DR.PRADIP DUTTA Department of Mechanical Engineering Indian Institute of Science Bangalore.
Update on Various Target Issues Presented by Ron Petzoldt D. Goodin, E. Valmianski, N. Alexander, J. Hoffer Livermore HAPL meeting June 20-21, 2005.
Flow and Thermal Considerations
Heat Transfer Rates Conduction: Fourier’s Law
RF-Accelerating Structure: Cooling Circuit Modeling Riku Raatikainen
STEADY HEAT TRANSFER AND THERMAL RESISTANCE NETWORKS
Fouling Factor: After a period of operation the heat transfer surfaces for a heat exchanger become coated with various deposits present in flow systems,
ISAT Module III: Building Energy Efficiency
Overall Heat Transfer Coefficient
1 Calorimeter Thermal Analysis with Increased Heat Loads September 28, 2009.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
ATLAS Calorimeter Argon Gap Convection Test Bed Brian Cuerden 24 Apr
Boiling Heat Transfer Source:
So Far: Conservation of Mass and Energy Pressure Drop in Pipes Flow Measurement Instruments Flow Control (Valves) Types of Pumps and Pump Sizing This Week:
ERT 216 HEAT & MASS TRANSFER Sem 2/
Application of QuickField Software to Heat Transfer Problems i j k By Dr. Evgeni Volpov.
Optimization Of a Viscous Flow Between Parallel Plates Based On The Minimization Of Entropy Generation Presentation By Saeed Ghasemi.
1 Calorimeter Thermal Analysis Revision C November
ATLAS Calorimeter Argon Gap Convection Test Bed April 25,
Convection: Internal Flow ( )
Test Bed Cases Attempting to Duplicate Test Results December 12, 2014.
Convection in Flat Plate Boundary Layers P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi A Universal Similarity Law ……
1 VI Single-wall Beam Pipe Option: status and plans M.Olcese TMB June 6th 2002.
STEADY HEAT CONDUCTION
1 Monophase Measurements on Prototype Pixel Structures D. Bintinger, M. Gilchriese, J. Taylor and J. Wirth and contributions from D. Cragg, E. Perrin and.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
M. Yoda, S. I. Abdel-Khalik, D. L. Sadowski, B. H. Mills and M. D. Hageman G. W. Woodruff School of Mechanical Engineering Correlations for Divertor Thermal-Hydraulic.
Cooling of GEM detector CFD _GEM 2012/03/06 E. Da RivaCFD _GEM1.
Heat Transfer Su Yongkang School of Mechanical Engineering # 1 HEAT TRANSFER CHAPTER 8 Internal flow.
TUTORIAL 1 7/3/2016.
Chapter 8: Internal Forced Convection
Chapter 15 Heat Transfer. Second Law of Thermodynamics Heat flows naturally from hot to cold objects. Heat will not flow spontaneously from cold object.
Heat transfer mechanism Dhivagar R Lecture 1 1. MECHANISMS OF HEAT TRANSFER Heat can be transferred in three different ways: conduction, convection, and.
HEAT TRANSFER Problems with FEM solution
Lesson 7: Thermal and Mechanical Element Math Models in Control Systems ET 438a Automatic Control Systems Technology 1lesson7et438a.pptx.
Internal Flow: General Considerations. Entrance Conditions Must distinguish between entrance and fully developed regions. Hydrodynamic Effects: Assume.
1 Calorimeter 4-May-2009 Added Slides Data from MAS GCALOR with phojet min-bias events in ATLAS detector.
HW/Tutorial # 1 WRF Chapters 14-15; WWWR Chapters ID Chapters 1-2
Fourier’s Law and the Heat Equation
Conservation of Mass and Energy
Calorimeter Transient Analysis for Steady State with ID Heat Leak and mini-FCal Analysis with 88.5°K Coolant in the Cooling Coil July 25, 2014 Brian Cuerden.
Temperature distribution and deflection in a bimetal
Chapter 8 : Natural Convection
Atlas Calorimeter with LN2 Cooling Loops, Revision B
Atlas Calorimeter with LN2 Cooling Loops
Conduction thermal resistance in different coordinate system
Data from MAS GCALOR with phojet min-bias events in ATLAS detector
Steady-State Heat Transfer (Initial notes are designed by Dr
Internal Flow: General Considerations
Presentation transcript:

Calorimeter Analysis Tasks, July 2014 Revision B January 22, 2015

Calorimeter Time Constant Check A simple model consisting of a mass with associated convective area was used for a time constant check. The mass and the convective surface are at the same temperature which increases over time due to applied heat. Model parameters are listed below.

Simple model compared to calorimeter results Simple model results are representative of the lower temperature nodes that were selected for the response plot. The gradients (in the detailed model) developed in 40,000 seconds after which the mass heated at a uniform rate. The time constant for gradient development (time to 63.2% of the steady state value) is 15,300 sec or 4.25 hrs. Steady state results are shown above. High temperatures occur in a fraction of the total volume in the heated region and away from the cooled region.

Simple Model with Various Shell Convection Coefficients The time constant of the simple model response is taken to be the time for 63.2% of the mass temperature change. at 50% of the nominal convective coefficient the time constant is 9.86 hours at 100% of the nominal convective coefficient the time constant is 4.58 hours at 200% of the nominal convective coefficient the time constant is 2.50 hours

Length of Mini-F-Cal The mini-F-Cal model was based on the “dimensions” tab of the Excel file “Heatmini.xlsx” as shown below. The specified and modeled length of the calorimeter is 30 cm as was intended.

Test Bed External Boundary Conditions Initially the six sides of the test bed box were constrained to be at 90°K Based on the gap convection results, external convection could be as low as 49 W/m 2 -°K – Free convection in the 12 mm gap on the 900 mm diameter calorimeter was 38 W/m 2 -°K for an 0.5°K differential and 49 W/m 2 -°K for a 2°K differential – On the 144 mm diameter ID with a gap of 14 mm convection was calculated to be 40 W/m 2 -°K for an 0.15°K differential – Because the fluid is less constrained around the test bed as compared to the gap cases, the free convection coefficient is expected to be larger than the above cited gap values and 49 W/m 2 -°K is taken as a minimum value. Conduction through the G10 on five sides is equivalent to 20 W/m 2 -°K (20 to 23.4 mm of G10). Adding convection to this gives 14 W/m 2 -°K or ~70% of the conduction expected if convection to the Argon pool is high. Conduction through the copper matrix is high so the addition of convection to the Argon pool makes a large difference. It is concluded that external convection cannot be neglected. Additional cases with external convection of 49 W/m 2 -°K and 98 W/m 2 -°K have been added to these results.

Summary of Test Bed Analysis Results The conduction across the argon layer will be determined by measuring the heat flux through the G10 layer and the temperature drop across the argon layer. – Heat flux and temperature drop will be measured near the centerline. Time required for stability: The heat flux through the G10 will be calculated from the gradient through the G10. The ratio of the G10 and argon gradients is stable after 0.4 hours for both nominal (low) and high external convection cases.

Temperature of the Argon Layer The argon layer temperature and the copper matrix temperature are sensitive to the external convection coefficient. It should be possible to determine the external convection coefficient from the test data. Boiling in the argon layer must be avoided. If the external convection coefficient is low the argon layer temperature will be higher and boiling may occur. This will increase the heat transfer rate since nucleate boiling is a particularly effective heat transfer mechanism.

Mini-F-Cal with Conductive Bars Contact conductance between the bar and the 12 mm OD pipe is estimated to be larger than or equal to an argon film 0.1 mm thick – Q/ΔT = 2.2 W/°K Argon conductivity is E-3 W/mm/K Area in contact is 12π*44 mm 2 Path length is 0.1 mm – For reference the conduction from the matrix to the tube through the 3x44mm strap is 12.4 W/°K Copper conductivity is Area is 3x44=132 mm 2 Path length is ~ 30 mm (20 mm to the tube and ¼ the distance around the tube – Contact resistance is modeled by decreasing the conductivity of part of the copper bar near the “tube”. The tube is a region constrained to 77°K

Nominal Power Level, Cooled only by the LN2 loop Most of the collimator is near 84 K. The bar could be shortened since most of its length is at the same temperature as the copper matrix. The only cooling here is from the LN 2 loop.

Operation at 7.5 times Power The LN 2 loop is still at 77°K but 7.5 times the power is applied resulting in a peak temperature of 132 K. Again the only cooling is from the LN 2 loop.

Operation at 7.5xPower with LN2 Loop Cooling and External Wall Cooling by 90°K Argon Peak temp is 101°K

Backup Slides Test bed results with various outer surface convection coefficients

Thermal Result for an 0.5°K Gradient Across the 12 mm Argon Layer, Net Conductance of the Argon is 3.8 Times the Conductivity of Argon Total heat input = 6.75 W Heat into 8 mm Al plate = 1.82 W Heat into 12 mm Argon layer = 1.77 W (21.9 W/m 2 ) Heat out of Argon Layer = 1.67 W Radial loss from Al and Argon 0.14 W Heat lost through base = 4.84 W 72% of the input heat is lost through the base. Most of the rest passes through the Argon 14 Outer surfaces fixed at 90°K (very high convection coefficient)

Thermal Result for a 2°K Gradient Across the 12 mm Argon Layer, Net Conductance of the Argon is 4.8 Times the Conductivity of Argon Total heat input = W Heat into 8 mm Al plate = 8.78 W Heat into 12 mm Argon layer = 8.62 W (107 W/m 2 ) Heat out of Argon Layer = 8.26 W Radial loss from Al and Argon 0.49 W Heat lost through base = W 70% of the input heat is lost through the base. Most of the rest passes through the Argon 15 Outer surfaces fixed at 90°K (very high convection coefficient)

Thermal Result for an 0.5°K Gradient Across the 12 mm Argon Layer, Net Conductance of the Argon is 3.8 Times the Conductivity of Argon Total heat input = 6.05 W Heat into 8 mm Al plate = 2.00 W Heat into 12 mm Argon layer = 1.90 W (23.6 W/m 2 ) Heat out of Argon Layer = 1.72 W Radial loss from Al and Argon 0.32 W Heat lost through base = 4.05 W 67% of the input heat is lost through the base. Most of the rest passes through the Argon 16 Outer surface convection to 90K is 49 W/m 2 -°K (nominal convection coefficient)

Thermal Result for a 2°K Gradient Across the 12 mm Argon Layer, Net Conductance of the Argon is 4.8 Times the Conductivity of Argon Total heat input = W Heat into 8 mm Al plate = 9.72 W Heat into 12 mm Argon layer = 9.35 W (116 W/m 2 ) Heat out of Argon Layer = 8.53 W Radial loss from Al and Argon 1.41 W Heat lost through base = W 66% of the input heat is lost through the base. Most of the rest passes through the Argon 17 Outer surface convection to 90K is 49 W/m 2 -°K (nominal convection coefficient)

A tabular summary of test bed results with various external convection values and with 0.5 and 2°K gradients in the Argon layer Reduced external convection results in a significant increase in the copper matrix and Argon layer) temperatures. Reduced external convection changes the ratio of Argon layer to G10 layer heat flux from 81-84% for high coupling to 74-76% for low coupling efficiency. “High” external convection means the external surface is set at 90°K “nominal” external convection is 49x10 -6 W/m 2 -°K

Temperature Drop Across the Argon Layer 19