Tissue Imaging by 5 kHz High-Performance MALDI-TOF Poster Number TP191 Christina Vestal 1, Kenneth Parker 1, Kevin Hayden 1, George Mills 1, Marvin Vestal.

Slides:



Advertisements
Similar presentations
High Performance MALDI MS, MS/MS, and Multiplexed MS/MS Tissue Imaging
Advertisements

Imaging MS MIAPE Working Document Helmholtz Institute, Munich, April 16 th 2012.
Imaging MS MIAPE Working Document Helmholtz Institute, Munich, April 16 th 2012.
Improvements in Mass Spectrometry for Life Science Research – Does Agilent Have the Answer? Ashley Sage PhD.
Mass Spectrometry Kyle Chau and Andrew Gioe. Computation of Molecular Mass -Mass Spectrum is a plot of intensity as a function of mass- charge ratio,
Evaluation of Peptides in Wisconsin Beer Mckenna L. Missfeldt, Dr. Jennifer Grant, University of Wisconsin-Stout Abstract Matrix-assisted laser desorption/ionization.
Oligonucleotide analysis by Linear MALDI-TOF mass spectrometry Stephen J. Hattan , Kenneth C. Parker, Marvin L. Vestal; SimulTOF Systems, 60 Union Ave,
Introduction to MALDI-TOF MS
Analyzing Biological and Organic Polymers by MALDI-TOF Jonathan A. Karty, Ph.D.
Laser Desorption Ionization Mass Spectrometry of Ink Katie Axwik Jory Schlitt Broc Glover.
Lecture 9. MALDI/TOF. Introduction Matrix-assisted laser desorption/ionization (MALDI) is a soft ionization technique used in mass spectrometry, allowing.
Novel 3-D Sample Plate using Monolithic Capture Media in Collimated-Hole Structures for Interfacing High Capacity Separations with MALDI-TOF Poster Number.
High Performance MALDI-TOF Mass Spectrometry Marvin Vestal and Kevin Hayden Virgin Instruments Corp. Sudbury, MA.
Development of TOF-MS from intellectual curiosity to practical technique Marvin Vestal SimulTOF Systems The Jim Waters Symposium at PittCon March 2, 2014.
MALDI MS Imaging on the 4800 MALDI TOF/TOF™ Analyzer Prepared by Andrew James, PhD.
PROTEIN IDENTIFICATION BY MASS SPECTROMETRY. OBJECTIVES To become familiar with matrix assisted laser desorption ionization-time of flight mass spectrometry.
Theodore Alexandrov, Michael Becker, Sören Deininger, Günther Ernst, Liane Wehder, Markus Grasmair, Ferdinand von Eggeling, Herbert Thiele, and Peter Maass.
Beta-Galactosidase Digest from 500 fmole Loaded on a 1-D Gel A. B. C. Bovine Serum Albumin Digest from 250 fmole Loaded on a 1-D Gel Automation of In-Gel.
Basics of 2-DE and MALDI-ToF MS
FIGURE 5. Plot of peptide charge state ratios. Quality Control Concept Figure 6 shows a concept for the implementation of quality control as system suitability.
MALDI Imaging Mass Spectrometry Nan Kleinholz Mass Spectrometry and Proteomics Facility The Ohio State University Proteomics Summer Workshop 2015.
Conventional and Computed Tomography
MALDI-TOF-TOF with High Resolution Precursor Selection and Multiplexed MS-MS Poster Number ThP 618 Kevin Hayden, Stephen C. Gabeler, Mark Dahl and Marvin.
Development of a TOF Version of the Desktop MiniSIMS Design & Applications A.J. Eccles, B. Cliff, C. Jones, N. Long, P. Vohralik Millbrook Instruments.
Proteomics Informatics – Overview of Mass spectrometry (Week 2)
Comparison of chicken light and dark meat using LC MALDI-TOF mass spectrometry as a model system for biomarker discovery WP 651 Jie Du; Stephen J. Hattan.
Introduction Recent research has proposed rapid and robust identification of intact microorganisms using matrix assisted laser desorption/ ionization time-of-flight.
Chapter 9 Mass Spectrometry (MS) -Microbial Functional Genomics 조광평 CBBL.
Marvin Vestal and Kevin Hayden Virgin Instruments Corp. Sudbury, MA
Gaucher’s Disease – A glycolipid storage disorder characterized by the accumulation of glucosylceramide in the spleen, liver, lungs, bone marrow and brain.
Tissue Imaging with New MALDI-TOF(TOF) Instrumentation Presented at MSIA 2013 Vanderbilt University April 17,2013 Marvin Vestal, CSO.
Acknowledgements This work is supported by NSF award DBI , and National Center for Glycomics and Glycoproteomics, funded by NIH/NCRR grant 5P41RR
Division of Bioorganic Chemistry and Molecular Pharmacology Department of Medicine Washington University School of Medicine - St. Louis Shotgun Lipidomics.
-Aluminum housing with o-ring seal allows for washing (salt removal), plate cleaning and regeneration enabling for multiple use -Sample elution for MS.
Marvin Vestal and Kevin Hayden SimulTOF Systems
Overall efficiency and speed of analysis – key factors are ions per sample molecule desorbed and ions produced per laser pulse Precision and accuracy of.
MS Calibration for Protein Profiles We need calibration for –Accurate mass value Mass error: (Measured Mass – Theoretical Mass) X 10 6 ppm Theoretical.
A new "Molecular Scanner" design for interfacing gel electrophoresis with MALDI-TOF ThP Stephen J. Hattan; Kenneth C. Parker; Marvin L. Vestal SimulTof.
Quantification of Membrane and Membrane- Bound Proteins in Normal and Malignant Breast Cancer Cells Isolated from the Same Patient with Primary Breast.
Temple University MASS SPECTROMETRY INTRODUCTION Ilyana Mushaeva and Amber Moscato Department of Electrical and Computer Engineering Temple University.
INF380 - Proteomics-51 INF380 – Proteomics Chapter 5 – Fundamentals of Mass Spectrometry Mass spectrometry (MS) is used for measuring the mass-to-charge.
MALDI demonstration Frímann, Helgi, Long, Nanna. Sample preperation The sample of interest and matrix are dissolved in a volatile solvent The sample/matrix/solvent.
High throughput Protein Measurement Techniques Harin Kanani.
Proteomics What is it? How is it done? Are there different kinds? Why would you want to do it (what can it tell you)?
The Future of Time-of-flight Mass Spectrometry
Innovative Paths to Better Medicines Design Considerations in Molecular Biomarker Discovery Studies Doris Damian and Robert McBurney June 6, 2007.
A versatile MALDI target plate based on polymer-filled reticulated vitreous carbon foam ThP Stephen J. Hattan ; Jie Du; Kenneth C. Parker VIC Instruments.
EBI is an Outstation of the European Molecular Biology Laboratory. In silico analysis of accurate proteomics, complemented by selective isolation of peptides.
Quantitative MALDI-TOF for Clinical Applications.
Velocity Map Imaging Study of a Mass-Selected Ion Beam: the Photoinitiated Charge-Transfer Dissociation of and Ag + (C 6 H 6 ) Jonathon A. Maner, Daniel.
Quantification of Albumin and Creatinine in Urine by MALDI-TOF Mass Spectrometry Jane Y. Yang, David A. Herold Department of Pathology, University of California.
Quantification of Glycated Hemoglobin by MALDI-TOF Mass Spectrometry
MALDI-TOF analysis of whole blood: its usefulness and potential in the assessment of HbA1c levels Jane Y. Yang, David A. Herold Department of Pathology,
2014 생화학 실험 (1) 6주차 실험조교 : 류 지 연 Yonsei Proteome Research Center 산학협동관 421호
RANIA MOHAMED EL-SHARKAWY Lecturer of clinical chemistry Medical Research Institute, Alexandria University MEDICAL RESEARCH INSTITUTE– ALEXANDRIA UNIVERSITY.
Yonsei Proteome Research Center Peptide Mass Finger-Printing Part II. MALDI-TOF 2013 생화학 실험 (1) 6 주차 자료 임종선 조교 내선 6625.
1 st : Mass Spectrometry on Heavy Molecules with Cryogenic Detectors - status Project Review 2004 PROTEOM 2 nd : Measurement of the Quenching Factors in.
Expanding lipidome coverage using LC-MS/MS data-dependent acquisition with automated exclusion list generation Supporting Information Jeremy P. Koelmel1,
Mass Spectrometry 101 (continued) Hackert - CH 370 / 387D
MALDI-TOF MS Bergdís Björk Bæringsdóttir Daníel Arnar Tómasson
Acknowledgements Slides and animations were made by Dr. Jon Karty Mass Spectrometry Facility Indiana University, Bloomington.
Starter Complete the quiz and hand in..
Schematic of the principles of mass spectrometry (MS).
Figure 1 Schematic representation of a typical MALDI-MSI workflow
Analyzing Biological and Organic Polymers by MALDI-TOF
Volume 2, Issue 4, Pages (April 2016)
Volume 143, Issue 3, Pages e2 (September 2012)
Pierre P. Massion, MD, Richard M. Caprioli, PhD 
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
Investice do rozvoje vzdělávání
Presentation transcript:

Tissue Imaging by 5 kHz High-Performance MALDI-TOF Poster Number TP191 Christina Vestal 1, Kenneth Parker 1, Kevin Hayden 1, George Mills 1, Marvin Vestal 1, Shannon Cornett 2, and Richard Caprioli 2. 1 Virgin Instruments, Sudbury, MA, 2 Vanderbilt University School of Medicine, Nashville, TN. Introduction Tissue imaging and profiling by MALDI-TOF MS provides unique information that facilitates our understanding of normal biological and pathological processes. This technology provides a high-throughput tool to interrogate protein expression in tissue at the molecular level. It can also provide direct measurements of distribution of drugs and metabolites in tissues and correlate these distributions with changes in the proteome. While many significant results have been reported over the past ten years, more widespread applications have been inhibited by limitations on the combined speed and spatial resolution available with existing instruments. In this work two new high-performance MALD-TOF instruments are evaluated for these applications. Method The new analyzers employ a 5 kHz laser for higher speed and better sample utilization. A linear MALDI-TOF mass spectrometers is used for imaging proteins. This analyzer operates at ion energy of 42 keV and includes a new hybrid detector that is immune to saturation effects without compromising time resolution. The second instrument is a reflector MS operating at 8 kV that provides very high resolving power and mass accuracy for peptides and small molecules. This instrument was used for imaging lipids in tissue samples using DHB matrix Sample Plates These instruments employ a sample plate 124x127 mm outside dimensions with 102x108 mm active area, allowing relative large samples such as whole body tissue sections from small mammals to be imaged with relatively high resolution. For this work adaptor plates accommodating up to 4 conductive 45x45 glass slides or 45x47 metal plates were used. An image of the plate is generated by a flat-bed scanner and that image is used to define the sample to be analyzed. Conclusions and Future Work This work has demonstrated that tissue images with 50 mm resolution can be generated with practical speeds for many applications using a laser operating at 5 kHz. There is no apparent loss in data quality relative to earlier work at Hz. We have demonstrated that up to 1 million spectra can be generated, stored, and processed per day, but at present data interpretation may be significantly slower than data acquisition. The images and spectra presented here represent a very small part of the total information available in one of these measurements. Further improvements in software and matrix deposition will be required to fully utilize this capability. References 1. J. A. Hankin, R. M. Barkley, R. C. Murphy, “Sublimation as a Method of Matrix Application for Mass Spectrometric Imaging”, J. Am. Soc. Mass Spectrom. 2007, 18, P. Chaurand, J. L. Norris, D. S. Cornett, J. A. Mobley, and R. M. Caprioli, “New Developments in Profiling and Imaging of Proteins from Tissue Sections by MALDI Mass Spectrometry”, J. Proteome Res. 2006, 5, Acknowledgements The assistance of Dr. Pierre Chaurand in providing the tissue sections with matrix deposition and the histological images of the sections. This work was supported in part by the National Institutes of Health under grants RR and GM TIC  m resolution protein The metal plate in the upper left position contains three mouse brain sections similar to those analyzed here, but all of the work presented was from samples on conductive glass plates. Whole mouse pup sections labeled 1-4 were analyzed for lipids using sublimed DHB matrix as described earlier. 1 This image was generated after analysis and most of the matrix has been desorbed. All 4 of these sections were analyzed in one day and generated 1,000,000 mass spectra. Data from one of these (3) is presented here. All of the data presented on protein imaging from whole mouse pup was generated from the sample on a glass slide at lower right. Matrix was spotted with sinipinic acid at 200 mm intervals using the automatic spotter described previously. 2 Example of mouse brain image generated with profile spectra. 250 shots per pixel, 1 mm/s raster at 50  m spacing. 100,000 spectra in 1.4 hours 20,000 RP note doublets High Speed Imaging of lipids in mouse brain sections. 2.5 mm/s, raster at 50 mm spacing, 50 shots/pixel (spectra transfer time 0.01 s) 50 pixels/s at 50 mm resolution 150,000 spectra in 50 minutes stained section for similar (but not identical) mouse brain section , 800,845,881 Lipid images of whole mouse pup section at 50 mm resolution, 100 shots/pixel, 150,000 spectra in 1.3 hours. Note: Our mouse is backside down. stain Protein images of whole mouse pup at 5 kHz, 37 mJ/pulse. Raster at 50 mm spacing, 1 mm/s 500 shots/spectrum, 50x100 mm pixels, 75,000 spectra in 2.2 hours. Expanded view of 1x1.5 mm portion of TIC for whole mouse image. Sinipinic acid matrix was spotted at 200 mm intervals and sample was scanned with 50x100 mm pixels. Results indicate that matrix spots typically less than 150 mm in dia and resolution of scanning is 50 mm. 200 mm brain bladder spine spinal cord Imaging of lipids and other small molecules using high-resolution Reflector TOF employs “on-the-fly” peak detection and calibration. Spectra are only saved if they meet predetermined criteria; typically a minimum intensity within a selected mass range. This has no effect on maximum acquisition rate (limited only by transfer time from digitizer to computer--typically <10 ms) but dramatically reduces storage requirements and accelerates data reduction and interpretation. Protein imaging with the linear TOF typically employs full profile spectra with 4 ns bins