Power Generation from Renewable Energy Sources Fall 2013 Instructor: Xiaodong Chu : Office Tel.: 81696127.

Slides:



Advertisements
Similar presentations
Chapter 3 Ohm’s Law.
Advertisements

Rooftop Solar Systems Rooftop Solar System (Off-Grid) Reliance Solar Energy™, Ratnagiri.
Foundations of Physics
CAPACITORS. WHAT IS A CAPACITOR? A Capacitor is a device that stores an electrical charge or energy on it’s plate.
Introduction Since the beginning of the oil crises, which remarkably influenced power development programs all over the world, massive technological and.
Unit 3 Simple Circuits. Electric current Voltage produces a flow of charge, or current, within a conductor. The flow is restrained by the resistance it.
Foundations of Physics
POWER SUPPILES LECTURE 20.
EKT214 - ANALOG ELECTRONIC CIRCUIT II
Photovoltaic Solar Cells and Solar Energy Systems for Home Usages Mohammad Anisuzzaman.
Objective of Lecture Describe the mathematical relationships between power and energy. Chapter 4.1 Relate power to voltage and current. Chapter 4.2 Explain.
© 2012 Pearson Education. Upper Saddle River, NJ, All rights reserved. Electronic Devices, 9th edition Thomas L. Floyd Electronic Devices Ninth.
Chapter 9 System Sizing Sizing Methodologies • Sizing Utility-Interactive Systems • Sizing Stand-Alone Systems • Sizing Multimode Systems • Sizing Hybrid.
SOLAR CELL PRESENTED BY ANJALI PATRA ANKITA TRIPATHY BRANCH-EEE.
Electricity Compare AC and DC electrical current and understand their important differences Explain the relationship between volts, amps, amp-hour, watts,
Inverters November 2007, Alex Righolt. Overview A&A Computers sell and install inverter systems as an alternative to UPS-es. Inverters are easily scaleable;
Solar Lightings Solar Module. Charge Controller. Battery. Inverter. Loads Accessories.
1 1 Electricity Introduction. 2 Electricity Current Four (4) requirements for an electrical current. 1An abundance of electrons (-) 2A scarcity of electrons.
Solar PV Design Implementation O& M March 31- April 11, 2008 Marshall Islands 2. Solar Home Systems (SHS) 2. Solar Home Systems (SHS) Herb Wade PPA Consultant.
Batteries Specifications Estimating when they will be fully discharged.
Lesson 9: Electrical Components
Power Generation from Renewable Energy Sources Fall 2013 Instructor: Xiaodong Chu : Office Tel.:
9/27/2004EE 42 fall 2004 lecture 121 Lecture #12 Circuit models for Diodes, Power supplies Reading: Malvino chapter 3, Next: 4.10, 5.1, 5.8 Then.
Generating and Using Electricity
Hybrid Wind & Solar Generation Project
Batteries Storing Renewable Energy “Chemical engines used to push electrons around”
Designing Solar PV Systems (Rooftops ). Module 1 : Solar Technology Basics Module 2: Solar Photo Voltaic Module Technologies Module 3: Designing Solar.
CHAPTER 18 Power Supplies. Objectives Describe and Analyze: Power Supply Systems Regulation Buck & Boost Regulators Flyback Regulators Off-Line Power.
Chapter Twenty One: Electrical Systems
Power Generation from Renewable Energy Sources Fall 2012 Instructor: Xiaodong Chu : Office Tel.:
PV off Grid Design Eng. Laith Basha
Applied Circuit Analysis Chapter 3 - Power and Energy Copyright © 2013 The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
S.A.A 06/071 LECTURE 4 PHOTOVOLTAIC SYSTEM. S.A.A 06/072 Introduction.. 3 common configuration of PV systems: –Grid-connected PV system –Stand-alone PV.
Serial vs. Parallel Connections. Serial Connections Serial connections are positive-to-negative in a chain.
Dynamic Presentation of Key Concepts Module 5 – Part 1 Fundamentals of Operational Amplifiers Filename: DPKC_Mod05_Part01.ppt.
Power Generation from Renewable Energy Sources Fall 2012 Instructor: Xiaodong Chu : Office Tel.:
Power and Power Measurement ENGR 10 – Intro to Engineering College of Engineering San Jose State University (Ping Hsu and Ken Youssefi) 1 Introduction.
System Sizing Sizing methodologies Sizing calculations.
Parts of An Electric Circuit Recall: a circuit is a closed path Electric circuit: closed path that flowing charge follows Constructing an electric circuit:
Elsarnagawy, MASH 207, 312 Energy and Power 1. Elsarnagawy, MASH 207, 312 Objectives Define energy and power Calculate power in a circuit Properly select.
Chapter 6 Voltage Regulators By En. Rosemizi Bin Abd Rahim EMT212 – Analog Electronic II.
Power Generation from Renewable Energy Sources Fall 2012 Instructor: Xiaodong Chu : Office Tel.:
Chapter 19 Review Current and Resistance. 1. A current of 2 amps flows for 30 seconds. How much charge is transferred?
Station Backup Power & Solar Powering your station.
Off Grid Living Without a Generator Solar Powered AC Coupled Micro Grid © Boyd Solar corp. Didsbury, AB
Electronic. Analog Vs. Digital Analog –Continuous –Can take on any values in a given range –Very susceptible to noise Digital –Discrete –Can only take.
ELECTRICAL SYSTEMS. Chapter Twenty One: Electrical Systems  21.1 Series Circuits  21.2 Parallel Circuits  21.3 Electrical Power.
Introduction to Solar Photovoltaic (PV) Systems – Part 2
EMT212 – Analog Electronic II
Battery Backup PV Systems Design Considerations
Avoid _____________ _____________ _____________ _____________ _____________ _____________.
Self Switching Power Supply. Introduction Self Switching Power Supply  Embedded system requires a regulated power supply.
Solar Power Charge Controller. Solar Power Charge Controller Introduction  A charge controller, or charge regulator is basically.
What Will We Do If Our Oil Supply Runs Out?. What Will We Do Click here to get an answer! If Our Oil Supply Runs Out?
Quiz: What is the voltage difference across the 25-  resistance? a) 0.1 V b) 2.5 V c) 6 V d) 25 V e) 60 V.
Chapter 2 Diode Applications. Objectives  Explain and analyze the operation of both half and full wave rectifiers  Explain and analyze filters and regulators.
Unit 7, Chapter 20 CPO Science Foundations of Physics.
Renewable Energy Systems David Buchla | Thomas Kissell | Thomas Floyd Copyright © 2015 by Pearson Education, Inc. All Rights Reserved Buchla, Kissell,
Basic Electronics for Computer Engineering 1 Chapter 3 Ohm’s Law.
Photovoltaic and Battery Primer
Photovoltaic and Battery Primer
Electronic Devices Ninth Edition Floyd Chapter 17.
Photovoltaic Systems Engineering Session 22 Solar+Storage Systems
Graduation Project-II submitted to:
Photovoltaic (PV) Systems
ELECTRICAL Currents & Energy
Sizing Methodologies • Sizing Calculations
Photovoltaic Systems Engineering Session 16 Solar+Storage Systems
Components inverters Except where otherwise noted these materials are licensed Creative Commons Attribution 4.0 (CC BY)
Presentation transcript:

Power Generation from Renewable Energy Sources Fall 2013 Instructor: Xiaodong Chu : Office Tel.:

Flashbacks of Last Lecture Configurations of grid-connected PV systems – PV array – Combiner box – Array disconnect switch – Maximum power tracker (MPPT) – Inverter – Breaker Protection design of grid-connected PV systems – Islanding – Reclosing

Flashbacks of Last Lecture Factors influencing performance of grid-connected PV systems – Mismatch – Reclosing

Example 9.6 of the textbook: you should master it! Flashbacks of Last Lecture

Photovoltaic Systems–Stand-Alone PV Systems A general stand-alone PV system includes a generator backup as well as the possibility for some loads to be served directly with more-efficient dc and others with ac A combination charger–inverter has the capability to convert ac to dc or vice versa

Photovoltaic Systems–Stand-Alone PV Systems Off-grid stand-alone PV systems must be designed with great care to assure satisfactory performance Users must be willing to check and maintain batteries, they must be willing to adjust their energy demands as weather and battery charge vary, they may have to fuel and fix a noisy generator, and they must take responsibility for the safe operation of the system

Photovoltaic Systems–Stand-Alone PV Systems The design process for stand-alone systems begins with an estimate of the loads that are to be provided for The user may try to provide the capability to power everything that grid-connected living allows Trade-offs are made between more expensive, but more efficient, appliances and devices in exchange for fewer PVs and batteries – A key decision involves whether to use all dc loads to avoid the inefficiencies associated with inverters, or whether the convenience of an all ac system is worth the extra cost, or perhaps a combination of the two is best – Another important decision is whether to include a generator back-up system and, if so, what fraction of the load it will have to supply

Photovoltaic Systems–Stand-Alone PV Systems AC Micro- (Nano-) Grid

Photovoltaic Systems–Stand-Alone PV Systems DC Micro- (Nano-) Grid

Photovoltaic Systems–Stand-Alone PV Systems Power needed by a load, as well as energy required over time by that load, is important for system sizing In the simplest case, energy (watt-hours or kilowatt-hours) is just the product of some nominal power rating of the device multiplied by the hours that it is in use The situation is often more complicated – Many appliances use different amounts of power during different portions of their operating cycle – Many devices use power even while they are turned off since some circuits remain energized awaiting the turn-on signal – Major appliances encounter the surge of power required to start their electric motors, which is important for sizing inverters, wires, fuses, and other ancillary electrical components in the system

Photovoltaic Systems–Stand-Alone PV Systems A inverter is needed for a stand-alone PV system to converter dc PV power to ac power of load side When no load is present, a good inverter will power down to less than 1 watt of standby power while it waits for something to be turned on that needs ac When it senses a load, the inverter powers up and while it runs on the order of 5–20 W of its own, which means those standby losses associated with so many of electronic devices may keep the inverter running continuously, even though no real energy service is being delivered

Photovoltaic Systems–Stand-Alone PV Systems Inverters are specified by their dc input voltage as well as by their ac output voltage, continuous power handling capability, and the amount of surge power they can supply for brief periods of time The inverter’s dc input voltage, which is the same as the voltage of the battery bank and the PV array, is called the system voltage – The system voltage is usually 12 V, 24 V, or 48 V – One guideline is based on keeping the maximum steady-state current drawn below around 100 A so that readily available electrical hardware and wire sizes can be used

Photovoltaic Systems–Stand-Alone PV Systems The maximum ac power that the inverter needs to deliver can be estimated by adding the power demand of all of the loads that will ever be anticipated to be operating simultaneously The most important specification for an inverter is the amount of ac power that it can supply on a continuous basis It is also critically important that the inverter be able to supply surges of current that occur when electric motors are started

Photovoltaic Systems–Stand-Alone PV Systems Stand-alone systems obviously need some method to store energy gathered during good times to be able to use it during the bad While various exotic technologies are possible including flywheels, compressed air, or even hydrogen production, it is the battery that makes the most sense today Batteries provide several other important energy services for PV systems – Provide surges of current that are much higher than the instantaneous current available from the array – Control the output voltage of the array so that loads receive voltages that are within their own range of acceptability

Photovoltaic Systems–Stand-Alone PV Systems Energy storage in a battery is typically given in units of amp- hours (Ah) at some nominal voltage and at some specified discharge rate A lead-acid battery, has a nominal voltage of 2 V per cell and manufacturers typically specify the amp-hour capacity at a discharge rate that would drain the battery down to 1.75 V over a specified period of time at a temperature of 25◦C

Photovoltaic Systems–Stand-Alone PV Systems Battery storage capacity is specified in amp-hours rather than watt-hours – A 200-Ah battery that is delivering 20 A is said to be discharging at a C/10 rate, where the C refers to Ah of capacity and the 10 is hours it would take to deplete (C/10 = 200 Ah/10 h = 20 A) – Rapid draw-down of a battery results in lower Ah capacity, while long discharge times result in higher Ah capacity – Deep-cycle batteries intended for photovoltaic systems are often specified in terms of their 20-h discharge rate (C/20), which is more or less of a standard, as well as in terms of the much longer C/100 rate that is more representative of how they are actually used

Photovoltaic Systems–Stand-Alone PV Systems The amp-hour capacity of a battery is not only rate- dependent, but also depends on temperature The combination of cold temperature effects on battery performance—decreased capacity, decreased output voltage, and increased vulnerability to freezing when discharged— mean that lead-acid batteries need to be well protected in cold climates However, the apparent improvement in battery capacity at high temperatures does not mean that heat is good for a battery

Photovoltaic Systems–Stand-Alone PV Systems

Battery efficiency is more easily expressed in terms of current efficiency than in terms of energy efficiency Assume charging a battery with a constant current I C over a period of time ΔT C during which time applied voltage is V C, inputting energy Suppose that the battery is discharged at current I D and voltage V D over a period of time ΔT D, delivering energy

Photovoltaic Systems–Stand-Alone PV Systems The energy efficiency of the battery is If we recognize that current (A) times time (h) is Coulombs of charge expressed as Ah, then The ratio of discharge voltage to charge voltage is called the voltage efficiency of the battery, and the ratio of Ah out to Ah in is called the Coulomb efficiency

Photovoltaic Systems–Stand-Alone PV Systems

If good weather could be counted on, battery sizing might mean simply providing enough storage to carry the load through the night and into the next day until the sun picks up the load once again The usual case is one in which there are periods of time when little or no sunlight is available and the batteries might have to be relied on to carry the load for some number of days During those periods, there may be some flexibility in the strategy to be taken – Some noncritical loads might be reduced or eliminated; and if a generator is part of the system, a trade-off between battery storage and generator run times will be part of the design

Photovoltaic Systems–Stand-Alone PV Systems Given the statistical nature of weather and the variability of responses to inclement conditions, there are no set rules about how best to size battery storage The key trade-off will be cost Sizing a storage system to meet the demand 99% of the time can easily cost triple that of one that meets demand only 95% of the time

Photovoltaic Systems–Stand-Alone PV Systems

A curve fitting technique could be used to approximate the relationship between storage days and peak sun hours Would you like to have a try on some curve fitting problems? – Many tools are available, e.g., Curve Fitting Toolbox of Matlab

Photovoltaic Systems–Stand-Alone PV Systems The simplest PV–battery system consists of just a single module connected to a battery and a DC load, with no charge controller, inverter, or anything else to complicate things Such a system might provide someone with a bit of light at night and maybe a few other simple amenities Some systems allow the battery to leak current back through the PV module at night, which raises the question of whether it might be worthwhile to add a blocking diode to prevent that nightly discharge

Photovoltaic Systems–Stand-Alone PV Systems

The equivalent circuit of a single PV cell will help us analyze the potential nighttime battery loss problem Ignoring the insignificant impact of the very small series resistance and eliminating the ideal current source I SC because the cell is in the dark at night Current through the diode in the equivalent circuit for a cell (at 25 ◦ C) is given

Photovoltaic Systems–Stand-Alone PV Systems The nighttime current from the battery through each cell will be where the voltage V d across the diode will be equal to the battery voltage V B divided by the number of cells n in the PV module With this simple nighttime equivalent circuit, we can decide how much leakage will occur from the battery through the PVs