Improvements of the A2 beamline for the linear polarised beam Patrik Ott Institut für Kernphysik Johannes-Gutenberg Universität Mainz 28.02.2011.

Slides:



Advertisements
Similar presentations
Conducted Immunity IEC
Advertisements

Perspectives for an energy increase of MAMI C Andreas Jankowiak Institut für Kernphysik Johannes Gutenberg – Universität Mainz Cristal Ball.
Eurotag Development of the European Tagged photon facilities. Spokesperson: Ken Livingston, Glasgowurl: Upgrade to 250MeV.
Automatic Position Control in the A2-Beamline Patrik Ott Institut für Kernphysik Johannes-Gutenberg Universität Mainz
Collimation and tagging instrumentation for the GlueX photon beamline Richard Jones Igor Senderovich, Anne-Marie Carroll University of Connecticut APS/DNP.
Measuring the Speed of Light Jack Young Rich Breazeale Ryan Phelan.
ATF2 Interaction Point Beam Size Monitor (Shintake Monitor) Status T. Yamanaka, M. Oroku, Y. Yamaguchi, S. Komamiya ( Univ. of Tokyo ), T. Suehara, Y.
Patricia Aguar Bartolomé Institut für Kernphysik, Universität Mainz PSTP 2013 Workshop, Charlottesville 11th September 2013.
Present status of the laser system for KAGRA Univ. of Tokyo Mio Lab. Photon Science Center SUZUKI, Ken-ichiro.
2 Introduction   MiniCal test-beam studies started at the beginning of March (till March 6 we only had 17 APD’s, then 33 APD’s)   A few days were.
Linear Collider Bunch Compressors Andy Wolski Lawrence Berkeley National Laboratory USPAS Santa Barbara, June 2003.
Measuring the Speed of Light! Photonic partners: David Orenstein Anuta Bezryadina Nathan Burd.
1 Laser Beam Coherence Purpose: To determine the frequency separation between the axial modes of a He-Ne Laser All sources of light, including lasers,
PRINCIPLES OF MEASUREMENT AND INSTRUMENTATION EKT 112
The Tagger Microscope Richard Jones, University of Connecticut Hall D Tagger - Photon Beamline ReviewJan , 2005, Newport News presented by GlueX.
Overview of Proposed Parameter Changes Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator.
Wrap-up 20 January 2004 Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center.
Spontaneous Radiation at LCLS Sven Reiche UCLA - 09/22/04 Sven Reiche UCLA - 09/22/04.
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS-II Stability Workshop April , 2007 NSLS-II Electrical Systems G. Ganetis NSLS-II Electrical Systems NSLS-II.
Progress towards nanometre-level beam stabilisation at ATF2 N. Blaskovic, D. R. Bett, P. N. Burrows, G. B. Christian, C. Perry John Adams Institute, University.
Chapter 9 Electromagnetic Waves. 9.2 ELECTROMAGNETIC WAVES.
Beam based calibration for beam position monitor 15-SEP-2015 IBIC2015 Melbourne M. Tejima, KEK TUBLA01.
Modelling of the ALICE Injector Julian McKenzie ASTeC STFC Daresbury Laboratory IOP Particle Accelerators and Beams Group Status and Challenges of Simulation.
EuroTag Workshop, Glasgow, 1/9/08 A General Geant4 Tagger Simulation David J. Hamilton University of Glasgow ( EuroTag.
1 Status of EMMA Shinji Machida CCLRC/RAL/ASTeC 23 April, ffag/machida_ ppt & pdf.
FLC Group Test-beam Studies of the Laser-Wire Detector 13 September 2006 Maximilian Micheler Supervisor: Freddy Poirier.
MOCT(Magneto Optic Current Transduser)
Status of Møller Polarimeter Peter-Bernd Otte September 23, th Collaboration Meeting, Mainz.
Grzegorz Jablonski, Technical University of Lodz, Department of Microelectronics and Computer Science XFEL-LLRF-ATCA Meeting, 3-4 December 2007 XFEL The.
Hadron physics Hadron physics Challenges and Achievements Mikhail Bashkanov University of Edinburgh UK Nuclear Physics Summer School I.
LOGO The η -mass measurement with the Crystal Ball at MAMI A. Nikolaev for the Crystal MAMI and A2 Collaborations Helmholtz Institut für Strahlen-
#3191, 14 Oct 2012 Cabling installed to allow fast BPM electronics on injector BPMs System is flexible enough to allow different INJ-BPMs to be used (not.
Synchrotron radiation at eRHIC Yichao Jing, Oleg Chubar, Vladimir N. Litvinenko.
Tohoku university Daisuke Okamoto TILC09 1. Motivation 2. Principle 3. Design 4. Expected performance 5. Conclusion contents.
Development of a Low-latency, High-precision, Intra-train Beam Feedback System Based on Cavity Beam Position Monitors N. Blaskovic Kraljevic, D. R. Bett,
Overview of the GlueX Tagger and Photon Beamline..
Coherent Diffraction Radiation experiment Konstantin Lekomtsev, Grahame Blair, Gary Boorman, Pavel Karataev, Maximilian Micheler John Adams Institute at.
1 BROOKHAVEN SCIENCE ASSOCIATES The use of fast-modulated elliptically polarized soft x-rays in the detection of small polarization signals Cecilia Sánchez-Hanke.
LASERS AND SPECTROSCOPY . EXCITING MOLECULES  Molecules can be excited using either broadband or monochromatic light. Spectra obtained using monochromatic.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
J. Pfingstner, LCWS13 Jitter and ground motion studies November 13, 2013 Beam jitter at ATF2: A. Source localisation and B. Ground motion correlation Jürgen.
CERN Accelerator School Superconductivity for Accelerators Case study 5 Group: Be Free Vicky Bayliss Mariusz Juchno Masami Iio Felix Elefant Erk Jensen.
1 Virgo Commissioning Status WG1 meeting Potsdam, 21 st July 2006.
Multipixel Geiger mode photo-sensors (MRS APD’s) Yury Kudenko ISS meeting, KEK, 25 January 2006 INR, Moscow.
Y. R. Roblin Hall A beamline and accelerator status.
UCLA IEEE NATCAR 2004 SUMMER CLASS Magnetic Sensors & Power Regulation.
J. Pfingstner Imperfections tolerances for on-line DFS Improved imperfection tolerances for an on-line dispersion free steering algorithm Jürgen Pfingstner.
Thomas Jefferson National Accelerator Facility SensL 6-Oct CHL-2 12 GeV CEBAF Upgrade magnets and power supplies Two 1.1GV linacs Enhanced capabilities.
Microwave Measurement of Recycler Electron Cloud: Jeffrey Eldred 12/19/14.
DaMon: a resonator to observe bunch charge/length and dark current. > Principle of detecting weakly charged bunches > Setup of resonator and electronics.
FSS Frequency Stabilisation System. Overview Why we need FSS:  Stabilise the optical frequency of fibre laser to +3 kHz  Use Rb frequency standard at.
FJPPL-FKPPL ATF2 Workshop Jitter studies March 18, 2014 Beam jitter localization and identification at ATF2 Marcin Patecki Jürgen Pfingstner 18 th of March.
SACE Stage 2 Physics Light and Matter Electromagnetic Waves.
Lecture 4 Longitudinal Dynamics I Professor Emmanuel Tsesmelis Directorate Office, CERN Department of Physics, University of Oxford ACAS School for Accelerator.
Beam Diagnostics Seminar, Nov.05, 2009 Das Tune-Meßverfahren für das neue POSI am SIS-18 U. Rauch GSI - Strahldiagnose.
Professor Philip Burrows John Adams Institute for Accelerator Science Oxford University ACAS School for Accelerator Physics January 2014 Longitudinal Dynamics.
Matthias Liepe. Matthias Liepe – High loaded Q cavity operation at CU – TTC Topical Meeting on CW-SRF
Progress in CLIC DFS studies Juergen Pfingstner University of Oslo CLIC Workshop January.
Interference of Light Ø It is generally He-Ne type that generates stable coherent light beam of two frequencies. one polarized vertically and another.
Optical Emitters and Receivers
A compact pair polarimeter and spectrometer
JINR: J. Budagov, M. Lyablin., G. Shirkov.
LASER (semiconducting Lasers)
INEL 6069 Klystron A power amplifier tube used to amplify weak microwave energy (provided by a radio- frequency exciter) to a high power level for a radar.
ELECTRON SPIN RESONANCE Dylan Prendergast Advanced Lab, Fall 2007
Present status of the laser system for KAGRA
Progress on J-PARC hadron physics in 2016
e-/e+ Vertical Beam Dynamics with 6 and 12Wigglers On
Linac Design Update P. Emma LCLS DOE Review May 11, 2005 LCLS.
Fanglei Lin JLEIC R&D Meeting, August 4, 2016
Presentation transcript:

Improvements of the A2 beamline for the linear polarised beam Patrik Ott Institut für Kernphysik Johannes-Gutenberg Universität Mainz

Content Motivation –Characteristics of linear polarised photon beam –Why do we need these two devices Beam Stabilisation –Recent Status –Possible automation? Pair-Spectrometer

Therefore collimation is a simple way to increase the relative amount of coherent linear polarised photons in the beam Coherent peak Ken Livingsten Characteristics of linear polarised photon beam Roman Leukel, Diss Large incoherent background Coherent part is strongly collimated Colli at 7.5 m pol. 70% Colli at 5.0 m pol. 58% Colli at 2.5 m pol. 44%

Problems of the collimation So far we have no possibility to measure the coherent peak without analysing the data Cause of the small emission angle, a small deviation of the electron beam can cause the complete loss of the linear polarised photons

Position control

A2-Beamline TM 110 Scanners The stabilisation converges best with the correction magnets SFA2WEDL06 and SFA2WEDL08.

Measuring the position in both cavities as a function of the current in both correction magnets With these gradients one can calculate the necessary change of current. The Hysteresis of the correction magnets cause an unpredictable error. Due to this only 90% of the aberration is compensated. After a few iterations the nominal position is reached without oscillation.

Measuring the position in both cavities as a function of the current in both correction magnets Cavity1 Cavity2 Magnet 1 Magnet 2 Necessity for convergence: Different slopes for both magnets in at least one cavity

Lock-in amplifier Cavity output 2.45 GHz MAMI main oscillator 2.45 GHz – 100 kHz 2.45 GHz ∆φ∆φ Add a reference Signal of 2.45 GHz – 100 kHz to reduce the frequency Measure the output signal at a time defined by the MAMI main oscillator To adjust the phase ∆φ one needs to steer the beam highly. This produces a large output signal so that the Lock-in amplifier can find a reproducible reference phase. 100 kHz Wavelength : 12.2 cm A difference of the electron path through MAMI of 2 cm reduces the signal output to one half.

Measured horizontal beam position Position is measured 25 times before switching to the other orientation. This is done to conserve the HF-Relay.

Measured vertical beam position Position is measured 25 times before switching to the other orientation. This is done to conserve the HF-Relay.

MAMI-Optimisation After a MAMI-optimisation the beam position often has a large offset, but the operator can bring back the beam with one button.

After the first 2 days of beam time, the accelerator is in thermal equilibrium and the position is quite stable. If an aberration is detected, it is not clear if the reference phase or the beam position is not right. Due to this, there is no automation so far. The operator gets an acoustic signal and adjusts the phase again. If an aberration is still detected he can correct the beam. During the phase adjustment we need the blank radiator. After a MAMI-optimisation the operator can bring back the beam with one button. Position Control

Pair-Spectrometer

Experimental setup Measure the tagger channels in coincident with the Pair-Spectrometer to get the coherent Peak.

Hamamatsu APD Dark currentSignal No need of HV Is not disturbed by magnetic fields easy connection with scintillator

First tests Does the setup work with the APD? Measure the influence of the current and the foil-thickness Can we find the coincident of both scintillators? Find the timing between Pair-Spectrometer and Tagger (Moeller-FPGA)

Provide an excellent grounding of the electronic to suppress noise. Find the correct timing in the FPGA Open the beam line to build in longer scintillators. Pair-Spectrometer To do list: