Relevant ITU-T Recommendations for the Protection of Base Stations

Slides:



Advertisements
Similar presentations
Introduction to Silicon Protection Array Devices.
Advertisements

Chapter 1 The Study of Body Function Image PowerPoint
By D. Fisher Geometric Transformations. Reflection, Rotation, or Translation 1.
Business Transaction Management Software for Application Coordination 1 Business Processes and Coordination.
International Telecommunication Union Seminar on Impact of Electromagnetic Field Emissions Kampala, Uganda, 3-5 September 2003 ITU-T Study Group 5 Publications.
ITU-T SG 5 Technical Session Lightning protection 12 December 2005, ITU Headquarters, Geneva ITU-T Technical Session Lightning Protection Highlights &
Nairobi, Kenya, 26 – 27July 2010 Role of ITU-T & ITU-R Ahmed ZEDDAM Ahmed ZEDDAM, ITU-T SG5 Chair France Telecom Orange ITU-T Workshop on Delivering Good.
International Telecommunication Union ITU-T SG 5 Technical Session Lightning protection 12 December 2005, ITU Headquarters, Geneva Risk assessment for.
International Telecommunication Union Technical Session on Home Networks Geneva, 29/04/2011 ITU-T Study Group 5 Protection against Lightning Phil Day Australia.
International Telecommunication Union Geneva, July 2009 Electrical Safety and Electromagnetic Compatibility Ahmed ZEDDAM, ITU-T SG 5 Chairman (France.
Cotonou, Benin, 19 July 2012 Overview of ITU-T/SG 5 activities Ahmed ZEDDAM Ahmed ZEDDAM, ITU-T SG5 Chair France Telecom Orange ITU Workshop on Tackling.
International Telecommunication Union ITU-T Study Group 5 The need for special requirements Tetsuya Tominaga Technical Session on Home Networks Geneva,
International Telecommunication Union ITU-T Workshop Lightning Protection Technical Session December 2005, Geneva, Switzerland Risk assessment for.
Summary of Results Study Period ITU-T Study Group 5 Protection against electromagnetic environment effects in telecommunications Roberto Pomponi.
ITU-T SG5 activities on EMF
Overview of SG5 and SG5RG for Africa activities
Standards for the protection of radio installations
Quito, Ecuador, 14 August 2013 Assessing EMF Levels Guidance and Recommendations Mike Wood EME Management Education & Compliance Telstra ITU Workshop on.
Paolo Gemma, Senior Expert, Huawei
Jeopardy Q 1 Q 6 Q 11 Q 16 Q 21 Q 2 Q 7 Q 12 Q 17 Q 22 Q 3 Q 8 Q 13
Jeopardy Q 1 Q 6 Q 11 Q 16 Q 21 Q 2 Q 7 Q 12 Q 17 Q 22 Q 3 Q 8 Q 13
Multiplying binomials You will have 20 seconds to answer each of the following multiplication problems. If you get hung up, go to the next problem when.
DIVIDING INTEGERS 1. IF THE SIGNS ARE THE SAME THE ANSWER IS POSITIVE 2. IF THE SIGNS ARE DIFFERENT THE ANSWER IS NEGATIVE.
FACTORING ax2 + bx + c Think “unfoil” Work down, Show all steps.
Addition Facts
Year 6 mental test 5 second questions
1 According to PETROSAFE safety policy, the company is keen that: Introduction All Egyptian Petroleum companies and foreign companies working in A.R.E.
BT Wholesale October Creating your own telephone network WHOLESALE CALLS LINE ASSOCIATED.
Grounding Electrodes.
Table 12.1: Cash Flows to a Cash and Carry Trading Strategy.
1 Washington, Oct. 2nd 2013 Informal working group: Large Lithium batteries testing RECHARGE & SAFT.
UNDERGROUND CABLES.
1 Recognize Any Hazard(s)?. 2 Yes No employer shall permit a worker to work in such proximity to any part of an electric power circuit that the worker.
Copyright © 2012, Elsevier Inc. All rights Reserved. 1 Chapter 7 Modeling Structure with Blocks.
ITU-T Study Group 5 “Environment and Climate Change”
Committed to connecting the world Overview of ITU-T Study Group 5 “Environment and Climate Change” Ahmed ZEDDAM France Telecom Orange Chairman, ITU-T Study.
Chapter 5 Test Review Sections 5-1 through 5-4.
Addition 1’s to 20.
25 seconds left…...
Committed to connecting the world Overview of ITU-T Study Group 5 “Environment and Climate Change” Cristina Bueti Adviser, ITU-T Study Group 5.
Week 1.
We will resume in: 25 Minutes.
1 Titre de la diapositive SDMO Industries – Training Département MICS KERYS 09- MICS KERYS – WEBSITE.
1 Unit 1 Kinematics Chapter 1 Day
How Cells Obtain Energy from Food
Announcements Be reading Chapters 9 and 10 HW 8 is due now.
Committed to connecting the world Ninth ITU Symposium on ICTs, the Environment and Climate Change Kochi, India, 15 December 2014 Damage prevention and.
EE4503 Electrical Systems Design
ASSIGNMENT TEACHER Smt. K.VASUMATHY GROUP MEMBERS:- MANSI DWIVEDI (ET 4 TH SEM) ARTI DWIVEDI (ET 4 TH SEM) DIKSHA CHANDRAKAR (ET 4 TH SEM) MAMTA CHOUDHARY.
Committed to connecting the world Ninth ITU Symposium on ICTs, the Environment and Climate Change Kochi, India, 15 December 2014 Damage prevention and.
MUHAMMADALI MC SDE(KAM) KANNUR EARTHING. O BJECTIVES OF EARTHING  To reduce the cross talk and noise  To afford reliable path for circuits involved.
Overvoltage Protection, A. Zeddam, Dakar, Senegal, 25 March 2015 ITU Regional Standardization Forum For Africa Dakar, Senegal, March 2015 Overview.
Overview of ITU-T Study Group 5 “Environment and Climate Change” Cristina Bueti, Adviser, ITU.
Overvoltage protection (surge arrester)
Protection against Electric Shock (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation.
International Telecommunication Union ITU-T SG 5 Technical Session “Lightning protection” 12 December 2005, ITU Headquarters, Geneva Risk regarding safety.
Eleventh ITU Symposium on ICTs, the Environment and Climate Change Kuala Lumpur, Malaysia, 21 April 2016 Damage prevention and safety Requirements for.
ITU Symposium on ICTs, the Environment and Climate Change Kuala Lumpur, Malaysia 21 April 2016 Session2: Damage prevention and safety Resistibility of.
Grounding the Electrical System Reference: AAVIM “Electrical Wiring” Created May 2007.
Committed to connecting the world Overview of ITU-T SG5 Work on Damage protection and safety Guy-Michel KOUAKOU Chairman of Study Group 5 Regional Group.
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
Radio Base Stations Sited on Power Line Towers
Grounding the Electrical System
Grounding the Electrical System
9. Deleterious effects of lightning and protective techniques
ELECTRIC SHOCK AND EARTHING
POWER QUALITY AND MANAGEMENT. TITLE : EARTH GROUND GRID SYSTEM AND POWER GROUND SYSTEM. PREPARED BY : JOBIN ABRAHAM.
Engineering Project Cable Management.
EET 323 – Electrical System Design Lecture 9: Grounding
Protection against over voltages
Presentation transcript:

Relevant ITU-T Recommendations for the Protection of Base Stations ITU Workshop on “Tackling climate change and Specific Absorption Rate (SAR) Measurement” (Cotonou, Benin, 19 July 2012) Relevant ITU-T Recommendations for the Protection of Base Stations Ahmed ZEDDAM, ITU-T SG5 Chair France Telecom Orange Cotonou, Benin, 19 July 2012

RECOMMENDATION ITU-T K.56 Outline INTRODUCTION LIGHTNING PROTECTION RECOMMENDATION ITU-T K.56 Need of Protection Earthing and Bonding procedures Use of SPDs DECOUPLING WITH POWER NETWORK CONCLUSION Cotonou, Benin, 19 July 2012

Protection of an installation may require a combination of: Introduction Protection of an installation may require a combination of: Lightning protection for the building Protection on incoming lines Resistibility of equipment Earthing and bonding of installation This presentation is about the protection of equipment within a base station Cotonou, Benin, 19 July 2012

SG 5 role in equipment protection SG 5 is unique SDO in overvoltage protection Ensures coordination of the equipment and external protection Considers installation practices and their effect on resistibility requirements Cotonou, Benin, 19 July 2012

Resistibility and protection Preventing equipment damage may require a combination of resistibility and protection Resistibility is The ability of the equipment to withstand an overvoltage or overcurrent Protection is The addition of primary protection to prevent damage from larger surges Need to check that the protector operates and protects the equipment Cotonou, Benin, 19 July 2012

Lightning Protection Lightning discharges can reach a telecommunication system by the following mechanisms: Cotonou, Benin, 19 July 2012

Lightning Protection Direct strikes Cotonou, Benin, 19 July 2012

Lightning Protection Coupling through the earth Cotonou, Benin, 19 July 2012

electromagnetic fields Lightning Protection Coupling through electromagnetic fields Cotonou, Benin, 19 July 2012

Lightning Protection  If adequate protection is missing, the lightning surges can be very dangerous to telecommunications systems, threatening : Terminal equipment Station equipment And even human beings  In order to protect the telecommunications systems against the effects of lightning discharges, the ITU-T SG-5 produced Handbooks and a set of Series K Recommendations: Cotonou, Benin, 19 July 2012

Recommendation ITU-T K Recommendation ITU-T K.56 : Protection of radio base stations against lightning discharges Presents the techniques applied to a telecom. radio base station in order to protect it against lightning discharges The need of protection is obtained from the methodology contained in IEC 62305-2, which is used to determine the relevant lightning protection level (LPL) for the installation The protection techniques for the external area cover the lightning protection system (LPS), bonding procedures, earthing and the installation of surge protective devices (SPDs) at the power meter station The protection techniques for the equipment building cover the feeder and lighting cables, the electric power conductors, the telecommunication cabling and the earthing/bonding procedures applied to cable trays and equipment frames Cotonou, Benin, 19 July 2012

Need of protection The risk assessment of the RBS shall be performed according to [IEC 62305-2] in order to determine a Lightning Protection Level (LPL) for the design of the protection procedures. Table 1 shows some lightning flash parameters associated with each LPL. Parameter Unit LPL I II III IV Maximum peak current kA 200 150 100 Maximum current rate of rise kA/s Radius of electro-geometric sphere m 20 30 45 60 Probability of flash % 99 98 95 90 Table 1 – Lightning flash parameters from [IEC 62305-1] Cotonou, Benin, July 2012

Earthing and bonding procedures applied to the external area Figure 1 – General view of earthing and bonding procedures in the external area Cotonou, Benin, July 2012

Earthing configuration Figure 5 – Earthing system of the RBS Cotonou, Benin, July 2012

Earthing configuration A bare conductor forms a ring electrode around the building and another ring around the tower. Multiple earthing conductors are used to interconnect the two rings (three, in the figure). The distance of the buried conductor from the associated structure shall be approximately 1.0 m, and the depth of the conductor shall be at least 0.5 m. Vertical rods should be installed along the ring electrode, as shown in Figures 1 and 5. These rods should be made of steel covered with copper or made of galvanized steel, and they shall be attached to the earth electrode by appropriate connectors. The legs of a metallic tower (or the down conductors of a non-metallic tower) shall be bonded through short connections to the tower's earthing ring. The steel reinforcement of the tower's basement, if any, shall also be connected to the earthing ring (see Figures 1 and 5). The steel reinforcement of the building's structure shall be bonded to the earthing ring at least at its four corners. If the building is metallic, its feet shall be bonded to the earthing ring. The earthing ring of the building shall be connected to the main earthing bar (MEB) located inside the building, preferably on the wall that faces the tower. The earthing conductor shall be as short as possible and have 50 mm2 as the minimum cross-section area. All conductors in contact with the earth should be made of copper or steel covered with copper and have 50 mm2 as the minimum cross-section area. Galvanized steel conductors could also be used, with 90 mm2 as the minimum cross-section area. A fence usually surrounds the terrain where the RBS is located. If the fence is metallic, some precautions have to be taken in order to minimize the hazard due to the voltages transferred by the fence. Cotonou, Benin, July 2012

Bonding at the feed-through window The cable manufacturers usually provide appropriate earthing kits for these connections Figure 6 – Example of earthing the feeder cable at the feed-through window Cotonou, Benin, July 2012

Use of SPDs Figure 7 – Diagram of the electric board Cotonou, Benin, July 2012

Installation of SPD in the electric board Figure 8 – Scheme for SPD installation on TT power systems The SPDs shall comply with [IEC 61643-11]  The SPD installed in the electric board shall coordinate with the SPD installed in the power meter station [see IEC 61643-12 for coordination] Annex A of [ITU-T K.66] gives information on SPD installation for different power systems. Cotonou, Benin, July 2012

Protection of telecommunication lines Figure 11 – Installation of SPD in the distribution frame  The procedures for the protection of telecommunication lines against direct and indirect lightning discharges can be found in [ITU-T K.47] and [ITU-T K.46], respectively, taking into account [ITU-T K.72]. Cotonou, Benin, July 2012

Example of earthing and bonding configuration inside an RBS  More information on the implementation of earthing and bonding configurations can be found in [ITU-T K.27] and [ITU‑T K.35 Cotonou, Benin, July 2012

Decoupling with power network  D1 : Distance entre la prise de terre des masses du poste de transformation HTA/BT et la prise de terre du Neutre BT,  D2 : La distance entre a prise de terre des masses du poste de transformation HTA/BT et la prise de terre du Site de Radiocommunication,  D3 : Distance entre a prise de terre du Neutre BT et la prise de terre du Site Radiocommunication Cotonou, Benin, July 2012

Decoupling with power network Cotonou, Benin, July 2012

Protection of Base Stations is based on the combination of : CONCLUSION Protection of Base Stations is based on the combination of : Lightning protection for the building Protection on incoming lines (SPDs) Resistibility of equipment Earthing and bonding of installation Decoupling with power network Recommendation ITU-T K.56 provides useful information for the protection of RBS and refers to other relevant Recommendations Cotonou, Benin, July 2012

Thank you Cotonou, Benin, 19 July 2012