LBE-Water interaction in LIFUS V facility under different operating conditions A. Ciampichetti, D. Bernardi - ENEA T. Cadiou - CEA N. Forgione – Università.

Slides:



Advertisements
Similar presentations
Associazione EURATOM ENEA sulla FUSIONE CONSEN A COMPUTER PROGRAM FOR TRANSIENT SIMULATION OF ENERGY AND MASS TRANSFER BETWEEN INTERCONNECTED VOLUMES DEVELOPED.
Advertisements

Control calculations Heat Engines & Boilers.
HEAT EXCHANGER GUIDED BY: PREPARED BY:
INTRODUCTION. Seminar on IMPROVEMENT OF THERMAL EFFICIENCY BY RECOVERY OF HEAT FROM IC ENGINE EXHAUST.
INTRODUCTION TO PRESSURE VESSELS
WP4 – Multi-phase flow THINS, Technical meeting - Bologna, 2/9/2010 Task 6.4 Assessment of damping pressure waves inside the SG WP6 – Lead Technology Experimental.
Nathan N. Lafferty, Martin L. deBertodano,
Lesson 17 HEAT GENERATION
Chapter 3.2: Heat Exchanger Analysis Using -NTU method
Thermal-Hydraulic Transient Analysis of the Missouri University Research Reactor (MURR) TRTR Annual Meeting September 17-20, 2007 Dr. Robert C. Nelson1,
Chapter 2: Overall Heat Transfer Coefficient
Chapter 1 VAPOR AND COMBINED POWER CYCLES
EUROTRANS – DM1 RELAP5 Model Evaluation with SIMMER-III Code and Preliminary Transient Analysis for EFIT Reactor WP5.1 Progress Meeting KTH / Stockholm,
October 25-27, th International QUENCH Workshop 1 Top Flooding Experiments and Modeling Estelle Brunet-Thibault (EDF), Serge Marguet (EDF)
Transmutation and ADS Safety EUROTRANS WP1.5 Meeting, Nov 27-28, Karlsruhe Simulation of EFIT Steam Generator Tube Rupture Accident (U-10) M. Flad, S.
Kick off meeting EFDA Task TW6-TSS-SEA2.1 Garching 10th/10/2006 ENEA Engineering approach of the potential accident scenario leading to the worst release.
Capture of Heat Energy From Diesel Engine After Cooler Circuit (2006 Annual Report) Mark Teitzel Alaska Village Energy Corporation
Royal Institute of Technology, Nuclear Power Safety AlbaNova University Center, SE Stockholm, SWEDEN 1 The SGTR Event.
1 Safety studies for MYRRHA B. Arien, S. Heusdains, H. Aït Abderrahim on behalf of the MYRRHA Team and Support IP-Eurotrans Workshop DM1-WP1.5Brussels,
LINEAR SECOND ORDER ORDINARY DIFFERENTIAL EQUATIONS
Evaluation of Safety Distances Related to Unconfined Hydrogen Explosions Sergey Dorofeev FM Global 1 st ICHS, Pisa, Italy, September 8-10, 2005.
Lesson 15 Heat Exchangers DESCRIBE the difference in the temperature profiles for counter-flow and parallel flow heat exchangers. DESCRIBE the differences.
STEAM CONDENSERS.
Chapter 3.1: Heat Exchanger Analysis Using LMTD method
Lease Automatic Custody Transfer
PSB H 0 -H - Injection: Sectorisation Analysis C.Pasquino, J. Hansen, P.Chiggiato LIU - PSB Ho-H- Injection Meeting 1.
KIT – University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association Institute for Nuclear and Energy Technologies.
Multi-Stage Flash Desalination (MSF)
Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling.
Thermal hydraulic analysis of ALFRED by RELAP5 code & by SIMMER code G. Barone, N. Forgione, A. Pesetti, R. Lo Frano CIRTEN Consorzio Interuniversitario.
Pro-Science 4 th International Conference of Hydrogen Safety, September 12-14, 2011, SAN FRANCISCO, USA EXPERIMENTAL STUDY OF IGNITED UNSTEADY HYDROGEN.
C. Chanson PPT 17 WRBRF, March 23-24, Berlin New development in Lithium batteries packaging.
Types of reactors.
Lead Technology Task 6.2 Materials for mechanical pump for HLM reactors M. Tarantino, I. Di Piazza, P. Gaggini Work Package Meeting Karlsruhe, November.
Vapour Compression Refrigeration Systems
Chapter One Basic Concepts in Refrigeration Basic Concepts in Refrigration1.
Thermal Model of MEMS Thruster Apurva Varia Propulsion Branch Code 597.
20 th June 20111Enrico Da Riva, V. Rao Project Request and Geometry constraints June 20 th 2011 Bdg 298 Enrico Da Riva,Vinod Singh Rao CFD GTK.
Explosion An explosion is a rapid expansion of gases resulting in a rapid moving pressure or shock wave. The expansion can be mechanical or it can be.
Accuracy Based Generation of Thermodynamic Properties for Light Water in RELAP5-3D 2010 IRUG Meeting Cliff Davis.
Development of a RELAP5-3D thermal-hydraulic model for a Gas Cooled Fast Reactor D. Castelliti, C. Parisi, G. M. Galassi, N. Cerullo (San Piero A Grado.
Valves In Industry (Part 3)
EUROTRANS – DM1 ENEA Activities on EFIT Safety Analysis ENEA – FIS/NUC Bologna - Italy WP5.1 Progress Meeting Tractebel / Brussels, March 17, 2006 G. Bandini,
ADVANCE IN AUTOMOBILES HYDROGEN FUELLED ENGINES BY C.SUBRAMANIAN, 10MECH50, III-MECH, VCET,MADURAI.
Cooling R&D at RWTH Aachen Lutz Feld, Michael Wlochal (RWTH Aachen University) CEC Meeting, CERN Lutz Feld, Michael Wlochal (RWTH Aachen University)
Silesian University of Technology in Gliwice Inverse approach for identification of the shrinkage gap thermal resistance in continuous casting of metals.
AN ALTERNATIVE PROPOSAL FOR A HIBRID REACTOR (SUB-CRITICAL FACILITY COUPLED WITH AN ACCELERADOR) Sergio A. Pereira and Adimir dos Santos.
Experimental and numerical studies on the bonfire test of high- pressure hydrogen storage vessels Prof. Jinyang Zheng Institute of Process Equipment, Zhejiang.
Convection: Internal Flow ( )
E3 Teacher Summer Research Program. Willie L. Smith - IPC, Physics Tidehaven ISD Tidehaven High School.
ERMSAR 2012, Cologne March 21 – 23, ON THE ROLE OF VOID ON STEAM EXPLOSION LOADS.
ERMSAR 2012, Cologne March 21 – 23, 2012 In-vessel retention as retrofitting measure for existing nuclear power plants M. Bauer, Westinghouse Electric.
ERMSAR 2012, Cologne March 21 – 23, 2012 Experimental and computational studies of the coolability of heap-like and cylindrical debris beds E. Takasuo,
Mitglied der Helmholtz-Gemeinschaft Jörg Wolters, Michael Butzek Focused Cross Flow LBE Target for ESS 4th HPTW, Malmö, 3 May 2011.
ERMSAR 2012, Cologne March 21 – 23, 2012 Post-test calculations of CERES experiments using ASTEC code Lajos Tarczal 1, Gabor Lajtha 2 1 Paks Nuclear Power.
Cryogenic scheme, pipes and valves dimensions U.Wagner CERN TE-CRG.
Bay Zoltán Foundation for Applied Reseach Institute for Logistics and Production Systems BAY-LOGI Assessment of crack like defect in dissimilar welded.
Heat Transfer by Convection
Process Safety Management Soft Skills Programme Nexus Alliance Ltd.
22 March The Institute of Petroleum’s “Guidelines for the Design and Safe Operation of Shell and Tube Heat Exchangers to Withstand the Impact of.
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
MODUL KE ENAM TEKNIK MESIN FAKULTAS TEKNOLOGI INDUSTRI
GOVERNMENT ENGINEERING COLLEGE, BHAVNAGAR TOPIC : INTRODUCTION TO PRESSURE VESSELS Prepared By :- 1.Aal Akash Ansari Aarif.
Audrey DUCLOS1, C. Proust2,3, J. Daubech2, and F. Verbecke1
Aachen Status Report: CO2 Cooling for the CMS Tracker
INTRODUCTION TO PRESSURE VESSELS
Risk Reduction Potential of Accident Mitigation Features
5. EXPERIMENT Material: Instrument Experiment condition:
NRC Event Number – Event Date
Aachen Status Report: CO2 Cooling for the CMS Tracker
Presentation transcript:

LBE-Water interaction in LIFUS V facility under different operating conditions A. Ciampichetti, D. Bernardi - ENEA T. Cadiou - CEA N. Forgione – Università di Pisa D. Pellini - KIT International DEMETRA Workshop Berlin, March 4th, 2010

Introduction The XT-ADS and EFIT reactors’ heat exchangers / steam generator modules are designed to be placed in direct contact with the heavy liquid metal in the main vessel. Since the likelihood of a pipe break is not negligible, the interaction between the secondary coolant and LBE represents an important concern for such a configuration. In fact, the consequences might have a strong impact on safety, design and maintenance of these reactors. Consequences The peculiarities of the heavy liquid metals (such as high thermal conductivity, high density and low surface tension) determine their gift to interact with water energetically, thus producing vapour at high pressure. The interaction leads to pressures waves propagation which might damage the surrounding structures, causing an escalation of the accident. The seriousness of the consequences is determined by the injection pressure and flow rate, the vapour production rate and the intervention of safeguards.

Description of work An experimental study focused on LBE/water interaction aimed at assessing physical effects and possible consequences relating to this kind of interaction has been performing in ENEA through LIFUS 5 plant. The main parameters for carrying out the experiments have been selected taking into account the XT-ADS primary heat exchanger design and the indications obtained from the pre-test activity performed with SIMMER code. The parameters considered have been: - system geometry; - lead temperature; - temperature and pressure of the water The modelling activity with SIMMER code have been performing in CEA and University of Pisa.

LIFUS 5 Facility The main LIFUS 5 components are: the reaction vessel S1, containing at the bottom the water injection device. Its volume is 100 l the expansion vessel S5, connected to S1 through four tubes. Its volume is 10 l the pressurised water vessel S2 the safety vessel S3 the liquid metal storage vessel S4 Instrumentation: S1 is equipped with water-cooled high precision piezometric pressure transducers, which allow to achieve very low time constants. A number of K-type thermocouples are also present. A fast DAQ system with a dedicated software acquires the main test parameters in different positions of the system. LIFUS 5 has been designed to simulate LOCA accidents and to operate in a wide range of conditions (pressure up to 200 bar, initial LM temperature up to 500 °C)

LIFUS 5 Facility

Experimental campaigns Three experimental campaigns for DEMETRA have been completed and the last one will be completed in March 2010.

Test n.1: experimental results Pressure evolutions in the reaction-expansion vessel First phase: the pressure reaches a maximum of about 65 bar. Second phase: pressure decreases in S1 because of the free flow of gases into S5 is not balanced by an equivalent injection of water. Third phase: there is a further pressure increase in both S1 and S5 due to the further water vaporization. A maximum value of about 80 bar has been reached. Fourth phase: pressure become stable at 70 bar due to the reverse flow-rate. Liquid metal temperature: 350 °C Water injection pressure: 70 bar Water temperature: 235 °C (sub-cooling of 50 °C) Test performed with the expansion vessel S5

Test n.1: modelling SIMMER model of LIFUS5 Pressure evolutions in the interaction vessel (S1) and expansion vessel (S5) S1 S5

Test n.2: experimental results Pressure evolution detected in gas phase followed the same trend as in LBE but the first sharp peak was not present. Liquid metal temperature: 350 °C Water injection pressure: 6 bar Water temperature: 130 °C (sub-cooling of 28 °C) Test performed without the expansion vessel S5 Temperature evolution detected in three vertical positions.

Test n.2: modelling /1

Test n.2: modelling /2 SIMMER III domains developed by PISA University Comparison between SIMMER simulations and experimental results Pressure evolution Temperature evolution University of Pisa

Experimental and SIMMER results of Test n.2 were used to support the assessment of the accidental scenario of “heat exchanger tube rupture” considered as reference accident in the safety analysis of the ICE activity. Test n.2: experimental results SIMMER domain for Test n.2 Safety activity for ICE /1

ICE simulations with SIMMER have shown that a double rupture of a HX tube produces a fast pressurisation of CIRCE main vessel that strongly overcomes the design value. ICE design team has developed another solution for the HX based on the adoption of water at 1 bar and double wall tubes Safety activity for ICE /2 University of Pisa

In order to simulate the possibility to discharge the vapour/liquid metal mixture outside the steam generator module during a tube rupture accident, the reaction system of Lifus5 facility has been modified. A discharge line directly connecting the reaction vessel S1 with the safety vessel S3 has been designed and constructed. Modification of LIFUS5

LIFUS5: old and new configuration

Test n.3: experimental results /1 Pressure evolution detected by the different transducers placed in S1 Liquid metal temperature: 350 °C Water injection pressure: 40 bar Water temperature: 235 °C (sub-cooling of 15 °C) Possibility to discharge in S3

Test n.3: experimental results /2 Pressure Temperature PT close to the water injectorPT in the flange of S1 TCs in front of the water injector

Features of the domain Simplified geometry: cylindrical coordinates (r-z) with 30 radial and 39 axial meshes. In LIFUS 5 there is a strong asymmetry in the geometry Assumptions 1.The overall volume of the main elements is conserved 2.The injector and vent pipe are placed coaxially with the reaction vessel S1 3.The flow area of the various pipes is conserved Test n.3: modelling /1 In the reaction vessel S1, U tubes are represented by 12 “no calculation” regions The strong asymmetry due to U tube shape and position cannot be adequately accounted for U tubes are simulated through annular elements which conserve the overall volume SIMMER III Model (2D): Geometry University of Pisa

Test n.3: modelling /2 Comparison between calculated and experimental pressure in S1 vessel SIMMER III overestimates the maximum value of the pressure in the reaction vessel S1 even though the trend is in agreement especially for the pressurization Comparison between calculated and experimental temperature in LBE region: top thermocouple University of Pisa

SIMMER IV Model (3D): Geometry 3-D model of LIFUS 5 facility performed with SIMMER IV code Simplified geometry: Cartesian coordinates (x- y-z) with 20 meshes along x, 15 along y and 18 along z The correct position of the water injector and of the vent tube is preserved Test n.3: modelling /3 University of Pisa

Test n.3: modelling /4 The 3D version of the code is able to evaluate the first pressure peak associated with the impact between the water jet and the “rigid surface” of the liquid metal. A better agreement concerning the maximum values reached with respect to SIMMER III results even though some discrepancies still remain. University of Pisa

Test n.3: modelling /5 Test Total mass of injected water [kg] SIMMER III1.66 SIMMER IV1.13 Experimental data1.60 Mass Flow Rate: Comparison between SIMMER III and SIMMER IV calculation results University of Pisa

Possible consequences The pressure evolution detected during Test n.3 has shown a first sharp peak and a following slower pressurisation of the system. In reactor scale the latter event can be avoided using adequate countermeasures (e.g. rupture disks, stop and check valves on the steam generator tubes). The first sharp peak reached about 15 bar in the pressure transducer closest to the water injector and smaller values in the other pressure sensors. This peak is originated from the impact of the water jet on the liquid metal and it could be a threat for the integrity of the surrounding tubes. Further tests are necessary to investigate this issue.

Conclusions Experimental results concerning the simulation of water large leaks in LBE have been obtained under different operating conditions. Maximum pressure values higher than the water injection pressure have been detected during Test n.1 and 2. The experimental results provided helpful data to prove the capability of the SIMMER code to simulate such an accident. SIMMER III was able to reproduce the interaction between a water jet and LBE, even though the 2D feature of the code has represented a limitation in reproducing the LIFUS 5 results. A new activity with SIMMER IV (3D) has been recently launched and is giving promising results. Test n.2 was used to support the safety analysis of ICE. In this case simulations showed that a double rupture in the LBE–pressurized water shell heat exchanger leads to a fast pressurisation of CIRCE main vessel that strongly overcomes the design value. Considering this warning, the ICE design team has adopted another solution with water at atmospheric pressure. LIFUS 5 has been modified in order to simulate the possibility of discharging the vapour/liquid metal mixture outside the steam generator module during a tube rupture accident as it might happen in lead cooled reactors. After that, Test n.3 was carried out in the operating conditions fixed for the heat exchanger of XT-ADS. Test n.3 has shown a first sharp pressure peak and a following slower pressurisation of the system. In reactor scale, the first peak could be dangerous for the surrounding structures while the following pressurisation can be avoided with adequate safeguards.