Today’s topic RTD D1&D2 Today I will talk about something of RTD and use D1 light to take the AFP Sweep.

Slides:



Advertisements
Similar presentations
©2012 Fluke Corporation SPRT Health 1 Health Monitoring of SPRTs.
Advertisements

The resistance measured by Wheatstone electric bridge School of Electronics & Applied Physics, Hefei University of Technology.
Overview of Temperature Measurement ME 115 Figures are from “Practical Guidelines for Temperature Measurement” unless otherwise notedwww.omega.com.
Pressure Sensors.
SENSORS AND TRANSDUCERS
Measurements in Fluid Mechanics 058:180 (ME:5180) Time & Location: 2:30P - 3:20P MWF 3315 SC Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor: Lichuan.
Temperature Measurement using sensors and signal conditioning
Resistors & Colour Coding
Resistors Electronics 1 CVHS.
Measurements in Fluid Mechanics 058:180:001 (ME:5180:0001) Time & Location: 2:30P - 3:20P MWF 218 MLH Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor:
Pressure Measurement Why is it important?. Pressure Measurement Asses the situation –What is the range of pressures to be measured? –Is pressure dynamic.
Chapter 3 Resistance.
Strain Gauges By Ross, James and Peter. What is a Strain Gauge? A strain gauge is a sensor that converts force, pressure, tension, weight etc into electrical.
Meters and Measurements
Classification of Instruments :
Displacement Transducers/Sensors
Presently Used Industrial Thermometers.. Resistance Temperature Detectors P M V Subbarao Professor Mechanical Engineering Department Active Temperature.
Sensors Introduction Describing Sensor Performance Temperature Sensors
Module 3 Eng. Asma Abu Baker. Introduction One of the most important uses of instruments or measuring devices is in the field of process control. If you.
Temperature Sensors.
“RESISTORS”. DEFINITION - It is an electronic component that has the ability to resist and/or oppose the flow of free electrons (current).
RESISTANCE. The resistance of a conductor is the ratio of the potential difference across it to the current flowing through it.
Interchangeability based Design of Resistance Temperature Detectors
EKT314/4 Electronic Instrumentation
Lecture 3: Bridge Circuits
Temperature Measurement
Resistance. This is a measure of a materials opposition to the flow of current through it. Unit: Ohms ( Ω )
Topic 1 different attributes that characterize sensors ETEC 6405.
We are Group5 Weatherstation The team Members are : Saran Jackson Robert Howard Robert Garvey Gene Fitzgerald Steven Dowling.
Welcome Changes to the International Standard for Industrial PRT’s
28 Feb 2000ISAT 3001 Resistance Temperature Detectors (RTDs)
Signal Conditioning and Linearization of RTD Sensors
Instrumentation (AMME2700) 1 Instrumentation Dr. Xiaofeng Wu.
ALTERNATING CURRENT METERS
DC Circuits Muhajir Ab. Rahim School of Mechatronic Engineering Universiti Malaysia Perlis.
Today’s agenda: Electric Current. You must know the definition of current, and be able to use it in solving problems. Current Density. You must understand.
Instrumentation (AMME2700) 1 Instrumentation Dr. Xiaofeng Wu.
Mechanical Measurement and Instrumentation MECN 4600
EKT 451 CHAPTER 5 DC & AC Bridge..
2 Resistors Chapter Topics Covered in Chapter 2
Resistors Topics Covered in Chapter 2 2-1: Types of Resistors 2-2: Resistor Color Coding 2-3: Variable Resistors 2-4: Rheostats and Potentiometers 2-5:
1 RTD (Resistance temperature detector) n Varying resistance with temperature n Good for measurement of small temperature differences n General equation.
Temperature Measure of internal energy of substance Four common scales Celsius (C) Kelvin (k) Fahrenheit (F) Rankine (R)
Filename: DPKC_Mod02_Part04.ppt
Lecture 3: Bridge Circuits
Displacement and Motion Measurement
INTRODUCTION Strain gauge measurement is a point strain measurement method developed in the USA c.a independently by E. Simmons and A. Ruge. It.
Balances The balance is an instrument which measures the mass of a body or substance using the gravity force which acts on that body At present, there.
Temperature Back to Basics RTDs (Resistance Temperature Detectors)
TEMPERATURE MEASUREMENT: ELECTRICAL TEMPERATURE SENSORS DEPARTMENT OF CHEMICAL ENGINEERING G.H. PATEL COLLEGE OF ENGINEERING & TECHNOLOGY VALLABH VIDYANAGAR.
1 How Does Temperature Non-uniformity of an Annealing Furnace Affect SPRT Stability? Speaker: Mingjian Zhao Authors: Mingjian Zhao, Rose Heaton, Rong Ding,
RESISTIVE TEMPERATURE TRANSDUCERS
Temperature Sensors.
TRANSDUCERS PRESENTATION BY: Dr.Mohammed Abdulrazzaq
Temperature sensors Temperature is the most often-measured environmental quantity. This might be expected since most physical, electronic, chemical, mechanical,
MECH 373 Instrumentation and Measurements
By Anupam Prakash (3RD YR EIE) ROLL NO.:
Electronic Instrumentation Lecturer Touseef Yaqoob
MECH 373 Instrumentation and Measurements
MECH 373 Instrumentation and Measurements
EMT 462 ELECTRICAL SYSTEM TECHNOLOGY Chapter 4: AC Meters By: En. Muhammad Mahyiddin Ramli.
ELECTRICAL METHODS TO MEASURE TEMPERATURE
Voltage and Current Sources Resistors Ohms Law
Overview of Temperature Measurement ME 115
Resistance AIM: Understand resistance, calculate resistor values and know the characteristics of different types of resistors PRIOR KNOWLEDGE: Understand.
Interchangeability based Design of Resistance Temperature Detectors
Prepared by Dr. Mohamed Ahmed Awad
Instruments & Electrical Measurements Lecture 3
TOPIC- Load cell A load cell is a transducer that is used to create an electrical signal whose magnitude is directly proportional to the force being.
Presentation transcript:

Today’s topic RTD D1&D2 Today I will talk about something of RTD and use D1 light to take the AFP Sweep.

Resistance temperature detector, RTD There are many categories; carbon resistors, film, and wire-wound types are the most widely used. Carbon resistors are widely available and are very inexpensive. They have very reproducible results at low temperatures. They are the most reliable form at extremely low temperatures. They generally do not suffer from hysteresis or strain gauge effects. Carbon resistors have been employed by researchers for years because of the many advantages associated with them. Film thermometers have a layer of platinum on a substrate; the layer may be extremely thin, perhaps one micrometer. Advantages of this type are relatively low cost and fast response. Such devices have improved performance although the different expansion rates of the substrate and platinum give "strain gauge" effects and stability problems. Wire-wound thermometers can have greater accuracy, especially for wide temperature ranges. The coil diameter provides a compromise between mechanical stability and allowing expansion of the wire to minimize strain and consequential drift. Coil Elements have largely replaced wire wound elements in the industry. This design allows the wire coil to expand more freely over temperature while still provided the necessary support for the coil. This design is similar to that of a SPRT, the primary standard which ITS-90 is based on, while still providing the durability necessary for an industrial process. The current international standard which specifies tolerance and the temperature to electrical resistance relationship for platinum resistance thermometers is IEC 751:1983. By far the most common devices used in industry have a nominal resistance of 100 ohms at 0 °C, and are called Pt-100 sensors ('Pt' is the symbol for platinum). The sensitivity of a standard 100 ohm sensor is a nominal 0.385 ohm/°C. RTDs with a sensitivity of 0.375 and 0.392 ohm/°C as well as a variety of others are also available. RTD is a detector that uses the electrical resistance which can change the resistance with changing temperature, and it has high accuracy and repeatability. They are almost made of platinum because of its linear resistance-temperature relationship and its chemical inertness, so it is also called platinum resistance thermometers. They are many categories, carbon resistors, film, wire-wound, and so on. I copied the introduction of it from Wikipedia. I’m not sure what categories we used, I guess carbon resistors, right? It’s more like it. I’m not familiar about its principle. The resistance of it is about 111 omega at 19.4 centi degree.

Advantages of platinum resistance thermometers: High accuracy Low drift Wide operating range Suitability for precision applications Limitations: RTDs in industrial applications are rarely used above 660 °C. At temperatures above 660 °C it becomes increasingly difficult to prevent the platinum from becoming contaminated by impurities from the metal sheath of the thermometer. This is why laboratory standard thermometers replace the metal sheath with a glass construction. At very low temperatures, say below -270 °C (or 3 K), due to the fact that there are very few phonons, the resistance of an RTD is mainly determined by impurities and boundary scattering and thus basically independent of temperature. As a result, the sensitivity of the RTD is essentially zero and therefore not useful. Compared to thermistors, platinum RTDs are less sensitive to small temperature changes and have a slower response time. However, thermistors have a smaller temperature range and stability. Here is the advantages and limitations of RTD, include high accuracy, low drift, wide operating range and suitability for precision applications, and can’t used above 660 degree and below -270 degree.

Two-wire configuration Wiring configurations The simplest resistance thermometer configuration uses two wires. It is only used when high accuracy is not required as the resistance of the connecting wires is always included with that of the sensor leading to errors in the signal. Using this configuration you will be able to use 100 meters of cable. This applies equally to balanced bridge and fixed bridge system. Three-wire configuration In order to minimize the effects of the lead resistances a three wire configuration can be used. Using this method the two leads to the sensor are on adjoining arms, there is a lead resistance in each arm of the bridge and therefore the lead resistance is cancelled out. High quality connection cables should be used for this type of configuration because an assumption is made that the two lead resistances are the same. This configuration allows for up to 600 meters of cable. Four-wire configuration The four wire resistance thermometer configuration even further increases the accuracy and reliability of the resistance being measured. In the diagram above a standard two terminal RTD is used with another pair of wires to form an additional loop that cancels out the lead resistance. The above Wheatstone bridge method uses a little more copper wire and is not a perfect solution. Below is a better alternative configuration four-wire Kelvin connection that should be used in all RTDs. It provides full cancellation of spurious effects and cable resistance of up to 15 Ω can be handled. Actually in four wire measurement the resistance error due to lead wire resistance is zero. Here is several configurations, there are many configurations can be choose, two-wire, three-wire, and four-wire. We use four-wire configuration in our target lab. I also haven’t researched its principle in detail.

placed Target upstream Target downstream Target chamber center Pumping chamber (Also for laser interlock) Oven Heater We put RTD in several places, outside the oven there has three RTDs, Target upstream, downstream and chamber center, you can see it in this pictures, and inside there is only one RTD at pumping chamber working now, another is broken now because of some reasons I don’t know. And also Oven and heater have RTDs too, though I don’t know where they put.

D1 & D2 5S1/2 5P1/2 5P3/2 D1 795nm D2 785nm Last week we did the NMR and EPR sweep several times, though the result is not very good, and also have many questions. Eric will talk about our progress this week. And I also did D1 EPR Sweep. You know, when a additional field is applied, these two states will be mixture and will increase the P two thirds state and we can pick up a D2 peak here, I don’t know what I said is right or wrong, I think here also the light will have a deep absorption here, because when the two states mixed the polarization of Rb will be destroyed a little and the polarized light will be absorbed again and the Rb will also emit the D1 light, because the light source is very narrow the Rb can absorb almost all of the light. and we can pick up this D1 light. But a question is, when the Rb is polarized, Rb will not absorb the D1 light anymore, so I think the peak is like this. I can’t understand it.

EPR FM Sweep D2 as reference D1 This is the FM Sweep of D1 and D2, you see, the peaks of them and the frequency range is very same.

AFP Sweep D2 as reference D1 And this is the AFP Sweep of D1 and D2, I don’t know why the D1 AFP is worse, may be the integration gain haven’t be adjusted so well.

EPR-NMR Analysis D2 as reference This is the Polarization Analysis of D1 and D2.

EPR-NMR Analysis D1

Fix the problem what we have Plan of next week Fix the problem what we have Try to adjust the oven temperature or adjust the power of the laser in order to see what will happen Next week we will fix the problem what we have and Try to adjust the oven temperature or adjust the power of the laser in order to see what will happen .

Thanks!