Simulation Needs in PET (Positron Emission Tomography)

Slides:



Advertisements
Similar presentations
What are PET basics?.
Advertisements

6: Positron Emission Tomography
1 Continuous Scintillator Slab with Microchannel Plate PMT for PET Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat 2, Fukun Tang 2,
PET Design: Simulation Studies using GEANT4 and GATE - Status Report - Martin Göttlich DESY.
1 Physics & Instrumentation in Positron Emission Tomography Paul Vaska, Ph.D. Center for Translational Neuroscience Brookhaven National Laboratory July.
Nuclear Medicine Spring 2009 FINAL. 2 NM Team Nuclear medicine MD Nuclear medicine MD Physicist Physicist Pharmacist Pharmacist Technologist Technologist.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
Gamma Camera Technology
Imaging PET Course Layout Class + ContentDateClass Physical Principles of PET I Physical principles of MRI II Imaging applications III.
Observation of Fast Scintillation of Cryogenic PbI 2 with VLPCs William W. Moses, 1* W.- Seng Choong, 1 Stephen E. Derenzo, 1 Alan D. Bross, 2 Robert Dysert,
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
Kirov A S, MSKCC Overview of Geant4 Use and Issues in Imaging: Emission Tomography (PET and SPECT) Assen S. Kirov Department of Medical Physics Memorial.
Single Photon Computerized Tomography SPECT neuroimaging Seyed Kazem Malakouti, MD Faculty of Iran University of Medical Sciences Seyed Kazem Malakouti,
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Detector technologies: from particle physics to radiotherapy
Positron Emission Tomography Outline PET Examples Imaging Goal Reconstruction/Data Requirements Method of Data Acquisition in PET –Positron Decay/Annihilation.
8/18/2015G.A. Fornaro Characterization of diffractive optical elements for improving the performance of an endoscopic TOF- PET detector head Student: G.
Coincidence imaging today
Very High Resolution Small Animal PET Don J. Burdette Department of Physics.
Novel high resolution detectors for Positron Emission Tomography (PET)
RAD2012, Nis, Serbia Positron Detector for radiochemistry on chip applications R. Duane, N. Vasović, P. LeCoz, N. Pavlov 1, C. Jackson 1,
Positron Emission Tomography (PET)
Positron Emission Tomography Oct. 28, 2003 Chang Kim, GE Medical Systems 1.Anatomic vs. Functional Imaging 2.Anatomy of PET What is PET? Isotopes and.
Coincidence to Image: PET Imaging Jennifer White Marketing Manager SNS Workshop October 13, 2003.
Design and simulation of micro-SPECT: A small animal imaging system Freek Beekman and Brendan Vastenhouw Section tomographic reconstruction and instrumentation.
For internal use only / Copyright © Siemens AG All rights reserved. Recent Innovations in PET and hybrid modality technologies Bernard Bendriem,
May 2015ECFA meeting1 Spin-off technologies for cancer diagnosis J. Varela, LIP Lisbon ECFA meeting, Coimbra, 15 May, 2015.
Innovation is in our genes. 1 Siemens Medical Solutions Molecular Imaging What are SPECT basics?
Department of Radiology UNIVERSITY OF PENNSYLVANIA 1 Investigation of LaBr 3 Detector Timing Resolution A.Kuhn 1, S. Surti 1, K.S. Shah 2, and J.S. Karp.
Nuclear Medicine Quality control.
Medical Image Analysis Dr. Mohammad Dawood Department of Computer Science University of Münster Germany.
19 May 2006 Chair for Computer Aided Medical Procedures & Augmented Reality Department of Computer Science | Technische Universität München Chair for Computer.
TU Delft IRI-ST Inorganic Scintillators in Medical-imaging Detectors C.W.E. van Eijk A msterdam, 9 September 2002.
HEALTH Novel MR-compatible PET detectors for simultaneous PET/MRI imaging FP7-HEALTH-2009-single-stage The focus should be to develop novel.
BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 1 Biomedical Imaging I Class 5 – Radionuclide Imaging (PET, SPECT), Part 3: Attenuation and Scatter.
Professor Brian F Hutton Institute of Nuclear Medicine University College London Emission Tomography Principles and Reconstruction.
Ultrasound, Positron Emission Tomography, and Single Photon Emission Tomography Allen T. Newton, Ph.D. PAVE 2014.
Chicago PET Development and Recent Progress in Digital TOFPET 1. Heejong Kim, Chien-Min Kao, Qingguo Xie, Yun Dong, Ming-Chi Shih, Antonio Machado, and.
Where do our data come from? Positron Emission Tomography (PET)
Nuclear Medicine: Tomographic Imaging – SPECT, SPECT-CT and PET-CT Katrina Cockburn Nuclear Medicine Physicist.
Data Acquisition Electronics for Positron Emission Tomography William W. Moses Lawrence Berkeley National Laboratory May 24, 2010 PET Overview PET Electronics.
Nuclear Medicine Physics
Seoul National University Functional & Molecular Imaging System Lab Progress in Nuclear Imaging Mikiko Ito, PhD Dept. of Nuclear Medicine, Seoul National.
Enhancing InBeam PET with single Photon (Compton) Detection CERN September 2nd 2008 VALENCIA GROUP, IFIMED José M. Benlloch (PET hardware, speaker) José.
A Single Photon Emission Computer Tomograph for breast cancer imaging S. Vecchio a, N. Belcari a, P. Bennati b, M. Camarda a, R. Campanini c, M. N. Cinti.
Impact of Axial Compression for the mMR Simultaneous PET-MR Scanner Martin A Belzunce, Jim O’Doherty and Andrew J Reader King's College London, Division.
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
Prostate probe with SPECT technique NSS – MIC November 5 - KnoxvilleF. Garibaldi- INFN – Roma1 – gr. Coll. ISS  the medical problem  the proposal.
1 Nuclear Medicine SPECT and PET. 2 a good book! SR Cherry, JA Sorenson, ME Phelps Physics in Nuclear Medicine Saunders, 2012.
Peter Dendooven LaBr 3 and LYSO monolithic crystals coupled to photosensor arrays for TOF-PET Physics for Health in Europe Workshop February 2-4, 2010,
1 Rome, 14 October 2008 Joao Varela LIP, Lisbon PET-MRI Project in FP7 LIP Motivations and Proposals.
A Multi-Threshold Method for TOF-PET Signal Processing Heejong Kim 1, Chien-Min Kao 1, Qingguo Xie 1, Chin-Tu Chen 1, Octavia Biris 2, Jialin Lin 2, Fukun.
Nuclear Medicine and PET rev this is now slide 1do not print it to pdf things to do (check off when complete): add revision date to cover page.
F. Garibaldi 1,, F. Cusanno 1), S. Majewski 3), N. Clinthorne, P. Musico 4),…………………………. TOPEM: a PET TOF probe, compatible with MRI and MRS for diagnosis.
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
PET Imaging Positron Emission Tomography
Simulations in Medical Physics Y. TOUFIQUE*, R.CHERKAOUI EL MOURSLI*, M.KACI**, G.AMOROS**, *Université Mohammed V –Agdal, Faculté des Sciences de Rabat,
+ Voxel Imaging Pizza Gianluca De Lorenzo. + Positron Emission Tomography April Gianluca De Lorenzo.
P.E.T. Positron Emission Tomography
Physics & Instrumentation in Positron Emission Tomography
MSc medical imaging, Division of Medical Physics, University of Leeds
Prof. Stefaan Vandenberghe Enrico Clementel
Advances in Imaging Instrumentation for Nuclear Cardiology
Qingguo Xie1,2, Chien-Min Kao1, Xi Wang2, Ning Guo2,
Monte Carlo Simulation
Application of Nuclear Physics
Single Photon Emission Tomography
A Multi-Threshold Method for TOF-PET Signal Processing
Function and Structure in
Presentation transcript:

Simulation Needs in PET (Positron Emission Tomography) Chin-Tu Chen, Ph.D. Department of Radiology & Committee on Medical Physics Pritzker School of Medicine & Division of Biological Sciences The University of Chicago The major purpose of this work is to develop computationally efficient techniques for accurate reconstruction of PET systems capable of providing some level of depth of interaction information. We will show that when using such reconstruction methods, it becomes possible to build low-cost, compact PET systems, we call ezPET systems. Such ezPET systems can produce PET images of good resolution and resolution uniformity by using a field-of-view almost as large as the detector ring size.

PET Principle P N + e+ + n + energy E = mc2

Production of Isotopes (Mini-Cyclotron) 18O (p,n) 18F

PET Isotopes 15O 13N 11C 18F PET Tracers 64Cu 82Rb 124I [15O]-O2 [15O]-H2O [15O]-H2O [15O]-CO [13N]-NH3 [18F]-FDOPA [13N]-glutamate [18F–] [11C]-acetate [18F]-FDG [11C]-palmitate [11C]-methionine 023

Metastatic Melanoma 71-year-old male with metastatic melanoma on left shoulder discovered 12/94. CT performed on 7/10/95 demonstrated tumor of the distal femur with negative findings in the abdomen. Bone scan on 7/13/95 showed an abnormal femur and four spine lesions. Whole-body FDG PET scan demonstrates numerous lesions throughout the body. Patient was scheduled for an amputation and total knee replacement based on CT and bone scan results. After PET found multiple lesions, surgery was cancelled, avoiding both the cost and the trauma of an operation that would not be effective. Courtesy of Amjad Ali, M.D. • Rush-Presbyterian-St. Luke’s Medical Center

Alzheimer’s Disease

13NH3 Images

Clinical Applications of PET — In Cancer

244

247

PET/CT Imaging Philips GEMINI PET/CT Open gantry for patient comfort Industry leading 190 cm contiguous scan length GSO PIXELAR detector design with 3D acquisition and 3D reconstruction for excellent image quality Brilliance high efficiency CT detector with sub-millimeter isotropic imaging Parametric PET and CT image registration in Syntegra multi-modality registration and review software Colon cancer,

Imaging of the Brain, Mind, Cognition, and Behavior

072

PET in Drug Development

062

Biochemical Imaging with Small Animals [11C]WIN 35,428 N 11CH3 O F OCH3 SLIDE 2: BIOCHEMICAL IMAGING The reasons for developing a dedicated animal tomograph are many. As more and more new drugs and treatment methods are developed, the need to find methods for testing these at their development stage has become increasingly more important. Radiotracer methods are excellent candidates as tools for research but they have the limitation that the animal must be sacrificed in order for the tracer distribution to be found. microPET was developed specifically for small animal functional imaging. Important dynamic information currently provided by using autoradiography and in-vitro assays can now be obtained in-vivo. This is advantageous because it reduces the total number of animals required, and inter-subject variability. Further, microPET can be used to monitor intervention of a single subject before, during and after the treatment. This equates to a reduction in cost as fewer animals are needed for a given study. microPET

microPET Images microPET EXACT HR+ baby rhesus monkey brain phantom (25 cc) - 1.2 mCi 18FDG 1hr. acquisition microPET SLIDE 8: PHANTOM IMAGES What this difference in voxel resolution translate too is illustrated in these 2 image sets. This phantom is based on the MRI of a baby rhesus monkey and its volume is only 25cc. The diameter of the active area in these slices is 3cm. Top images are from microPET bottom images are from ECAT EXACT HR+ EXACT HR+

Animal Studies: 11C-WIN 35,428 in collaboration with Bill Melega Vervet Monkey Rat Mouse x2 x2 Transverse SLIDE 9: C11-WIN COMPARISON STUDY UCLA has performed studies with the cocaine analog C11-WIN on three different species: a vervet monkey, a rat and a mouse. Here we see the very specific uptake of the striata of these animals. As these transverse and coronal images show, we can get good detail. Enough to see specific uptake down to the mouse brain size. Coronal

FDG Whole Body Rat Study SLIDE 14: WHOLE BODY RAT One of the most difficult tests of a system comes with whole body imaging. Here is a whole body study of a rat which was injected with 2.5mCi of FDG and imaged for ~2 hrs. This shows the usefulness of microPET for biodistribution studies. I’d like to point out that this study was performed on a system with 1/4 of the axial extent of the commercial microPET. This study would take considerably less time using the commercial system. Injected dose: 2.5 mCi Imaging time: ~2 hrs.

Whole body image of a normal rat injected with fluorine-18 fluorodeoxyglucose (FDG), illustrating glucose utilization. Mouse model with one tumor on each shoulder. The left tumor expresses the D2 receptor gene and uptakes FESP, while the tumor on the right, represses the tk gene and uptakes FPCV.

Human PET: 3-4mm; Target: 1-2mm Animal PET: 1-2 mm; Target: <0.5mm 024 Human PET: 3-4mm; Target: 1-2mm Animal PET: 1-2 mm; Target: <0.5mm

Simulations in PET Source Distributions Imaging Physics Attenuation Scattering etc.

045

The neue Cologne Phantom 3 mm structure 2 mm structure

Simulations in PET Imaging System Geometry Configurations

HRRT: Octagon - 120,000 crystals 936 electronic channels 4.486*109 LORs

A Benchtop Prototype for High-Throughput Animal Imaging HRRT modules LSO crystals with DOI capability good spatial resolution ~2.42mm crystal pitch ~10mm DOI resolution good detection sensitivity high count rate large detection sensitive area ~25.2cm ×17.4cm 72×104 crystals per layer off-shelf, well tested, cost-effective design adjustable energy and coincidence windows We are setting up the proposed dual-panel system by using two HRRT modules from CPS. This module uses about 2.25mm wide LSO crystals and provides depth of interaction information by using two layers of LSO crystals of different decay time constants, each layer is 10 mm thick. The module can support high count rate. It has a large detection sensitive area, about 25.2x17.4cm and contains 104 by 72 crystals per layer. This module has been well tested and is available from CPS. It adopts quadrant sharing design to reduce the number of photomultiplier tubes to decrease the production cost.

Multi-Modality Integrative System Siemens “Molecular Imaging” PET/SPECT PET/MRI PET/SPECT/CT For Animal Imaging Siemens “Molecular Imaging”

Scintillation Crystals Simulations in PET Photon Detection Scintillation Crystals Photon Sensors PMT/APD/SiPM

Initial Photon Rate (ph/MeV-ns) Scintillation properties of primary crystals in PET Material Denstiy (g/cm3) Decay time (ns) aLight Yield Initial Photon Rate (ph/MeV-ns) Energy resolution %@662 keV NaI:Tl 3.67 230 100 164 6.5 Bi4Ge3O12(BGO) 7.13 300 22 27 9.3 Gd2SiO5:Ce(GSO) 6.71 60 167 7.8 Y2SiO5:Ce(YSO) 4.54 70 377 9.0 Lu2SiO5:Ce(LSO) 7.40 40 80 750 7.9 cLu2(1-x)Y2xSiO5:Ce(LYSO) 7.11 845 7.5~9.5 dLu2(1-x)Gd2xSiO5:Ce(LGSO) 61 575 12.4 Lu2Si2O7:Ce(LPS) 6.23 38 692 9.5~12.5 BaF2 4.89 b0.8 b2300 7~8 LaBr3:Ce0.5% 5.29 35 162 1743 3.0 aRelative to NaI(Tl)=100 bIt is the fast scintillating component of BaF2. cx=0.1 dx=0.1

PET Components detectors block detectors: BGO, LSO, GSO crystals

Quadrant Sharing Design 8x8 crystal matrix; two layer LSO LSO-fast/LSO-slow (or LSO/GSO) 128 single crystals in 2 layers 2.1 x 2.1 x 7.5 mm3

Simulations in PET Electronics (Fast Electronic)

Custom Integrated Circuit Electronics Detector Analog ASIC Detector Digital ASIC Digital Coincidence ASIC Analog Detector Signals Processes Digital X, Y Energy, and Time Data Processes Digital Crystal Position and Time Data Processes Digital PET Coincidence Data

CMOS PET Front End Integrated Circuit Serial Interface Gain Control DACs CMOS PET Front End Integrated Circuit Preamps, Variable Constant Fraction Gain Amps, Summers Discriminator* ECL Driver 6.4 mm Gated Integrators CFD Thld DAC X, Y Offset DACs 6.0 mm * U.S. Patent 5,396,187

Depth-of-Interaction (DOI) Simulations in PET List Mode Position Energy Timing Depth-of-Interaction (DOI) Time-of-Flight (TOF)

DOI Detectors Phoswich detectors photo-diodes LSO GSO/LSO PMT scintillator (BGO) PMT photo diode

Depth-of-Interaction (DOI) Detector

Time-of-Flight Tomograph  x Can localize source along line of flight - depends on timing resolution of detectors Time of flight information can improve signal-to-noise in images - weighted back-projection along line-of-response (LOR) D One normal variation in PET cameras is the “time-of-flight” or TOF design. By measuring the difference in arrival time at the two detectors, the positron source can be localized along the line of flight. Doing this does not improve the spatial resolution, but improves the signal to noise ratio (the mechanism will be described in more detail in the next slide) — the variance improves by a factor of 2D/ct, where D is the diameter of the radionuclide distribution, c is the speed of light, and t is the TOF resolution. Several TOF PET systems were built in the 1980’s with barium fluoride or cesium fluoride scintillators. They achieved ~500 ps timing resolution, which results in 8 cm localization. For objects the size of the human head (which was what most PET cameras imaged in the 1980’s) the net result is a tomograph with a factor of ~2 lower variance than a non-TOF BGO tomograph. Problems arose from the use of barium fluoride as a scintillator. It is less dense than BGO, and so the spatial resolution is degraded. In addition, the wavelength of its fast emission is in the hard UV, which made it difficult to work with (i.e. expensive) because it does not penetrate glass-windowed photomultiplier tubes or any known glue (to couple the crystal to the photomultiplier tube). Finally, it was difficult to keep these cameras in tune. Thus, TOF PET largely died at the end of the 80’s. However, the advent of LSO and other new PET scintillators (that can provide excellent timing resolution without the material drawbacks of barium fluoride) makes TOF a promising direction for modern PET.  x = uncertainty in position along LOR = c . t/2 Karp, et al, UPenn

Benefit of TOF no TOF 300 ps TOF 1 Mcts 5 Mcts 10 Mcts Better image quality Faster scan time 1 Mcts 5Mcts 1Mcts 1Mcts TOF 5Mcts TOF 5 Mcts 10 Mcts Karp, et al, UPenn

Simulations in PET Image Reconstruction Image Processing Image Analysis

Multi-Modality Bayesian Image Reconstruction One area that our image reconstruction group pioneered is the concept of multi-modality image reconstruction. Using the co-registered CT or MRI images, Dr. Chen and his group demonstrated that image quality can be improved very substantially by a Bayesian image reconstruction algorithm that incorporates high-resolution information from CT/MRI in the reconstruction of PET or SPECT images. Upper Two: Filtered BackProj. Lower Two: Multi-Modality Image Reconstru. Chen, Kao, et al Co-registration of PET/SPECT with CT/MRI Incorporation of high-resolution information from the co- registered CT/MR images into a Bayesian image recons- truction framework to enhance image quality of PET/SPECT Using the co-registered CT/MR images as an anatomic map in correction for attenuation and scatters in PET or SPECT

Dual Planar Detector High-Throughput Animal PET Imager Dual Layer D.O.I. Detectors (LSO) Variable Detector Face-to-Face Spacing

Example Reconstruction 25.2 cm 5 cm ~16 cm Noiseless data To examine how the missing data affect image quality, we do a preliminary study by considering only the stationary configuration with different number of subjects inside. The objects are the these 2cm-diameter disks. Again, the panel spacing is 5 cm. We use computer simulations to generate data and perform reconstruction by using the EM algorithm. The results shown here that you can get decent reconstruction up to about ~16 cm wide FOV, especially for noisy data no noticeable differences are observed between 5-subject and one-subject imaging. So our results suggest that with a compact geometry and good reconstruction algorithm we can indeed achieve good reconstruction for a large FOV. Noisy data

Simulations in PET Physiology Biochemistry Biology

18Fluoro-2-deoxy-D-glucose

024

System Geometry/Configuration Source Distribution/Physics Simulations in PET System Geometry/Configuration Source Distribution/Physics Photon Detection/Collection Electronic ListMode/DOI/TOF Image Reconstruction Physiological Modeling