Gail Vanairsdale Global Clinical Education Manager Enlite Sensor Insertion.

Slides:



Advertisements
Similar presentations
Wash hands using standard precautions techniques..
Advertisements

Assisting Another Sterile Team Member
Injection for Medications
Session IV B, Slide #1 Contraceptive Implants Session IV B: One-Rod Implant Removal.
Self-Cannulation. 2 Why Offer Self-Cannulation? Benefits for patients: –Less painful –Less likely to promote fear and anxiety –Less stressful –Greater.
NUR 113: SKILL 8-2: PREPARING A STERILE FIELD
DBS preparation from finger stick blood in Microtainer®
Fingerstick Procedure
Injection. Photo of a typical juvenile diabetic before and after treatment.
111 LESSON 7 How to give an injection with Sayana Press.
Module: Session: Advanced Care Paramedicine Medication Routes 6 4a.
Session IV: Practicing Provision of Progestin-Only Injectables
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
7- Intravenous (I.V) Infusion
Laboratory Training for Field Epidemiologists Best infection control measures for sampling venous and capillary blood WHO intermediate recommendations.
Starting a Peripheral IV Principles of IV Therapy BSN336 Lab.
Smallpox Vaccine Administration Department of Health and Human Services Centers for Disease Control and Prevention December 2002.
Insulin Administration by Syringe 8/17/ This PowerPoint covers basic procedures for administering insulin by syringe. There are different kinds.
MC11000 Kit Replacement 1 1. Open the face plate and remove the 2 screws. Remove and discard the original face plate. 3. Remove the 2 white caps on the.
PRPEARED BY : SALWA MAGHRABI CLINICAL INSTRUCTOR
Copyright 2008 Kenneth M. Chipps Ph.D. How to Use the 3M Mechanical Splice Tool Last Update
1 July 2007 P48610 Rev.2 SmartInfuser PainPump ™ P49220, P49224N Operation Instructions.
INSULIN BY PEN 12/2008.
Subcutaneous Intramuscular Injections
Helping Belton ISD Students Succeed What BISD Staff Need to Know About: Helping Belton ISD Students Succeed What BISD Staff Need to Know About: Insulin.
Insulin Pens An interactive, instructional module on the correct technique of insulin pens.
Intramuscular Injections
Injections. Injections – general rules  Expiry dates Check the expiry dates of each item including the drug. Check the expiry dates of each item including.
Administration of Vaccine via Intramuscular Route
Fingerstick Proficiency Training. Overview  Fingerstick waiver form  Background presentation  Universal Precautions  Demo  Participants do 5 sticks.
Session VI, Slide #1 Contraceptive Implants Session VI: Infection Prevention.
Interactive Learning Tool For Patients And Nurses By: Regina Jones.
Session IV A, Slide #1 Contraceptive Implants Session IV A: One-Rod Implant Insertion.
Session V B, Slide #1 Contraceptive Implants Session V B: Two-Rod Implant Removal.
Session V A, Slide #1 Contraceptive Implants Session V A: Two-Rod Implant Insertion.
Using Sterile Technique to Load a Syringe
Sterile Techniques. Surgical Asepsis A. Involves keeping the clinical setting and objects as free from microorganisms as possible. B. Used in operating.
Administration of Vaccine via Subcutaneous Route Hand hygiene is the first step in medication administration is hand hygiene. Use either an alcohol-based.
Wildlife Forensics Environmental Study Center. Chinchilla.
 Teach patient to rotate injection sites (subcutaneous areas) daily.  Change needles daily.  Insulin is most effective when injected into the abdomen.
Chapter 9 Routine Venipuncture.
Blood collection.  Venipuncture is the collection of blood from a vein. As a general rule, arm veins are the best source from which to obtain blood.
Smallpox Vaccine Administration  Learning Objectives Demonstrate appropriate vaccine administration techniques Demonstrate appropriate vaccine administration.
INSULIN BY SYRINGE AND VIAL 12/2008.
Open Gloving Removing Soiled Gloves
Dalia Kamal Eldien Mohammed. introduction  Types of blood specimen include  Venous blood  Capillary blood.
Biochemistry Clinical practice Lecturer of Biochemistry
Asepsis Gloving. When to Wear Sterile Gloves Sterile gloves should be worn when there is direct contact with other sterile supplies and equipment Sterile.
First Aid Dressings and Bandages. Dressings *Covers an open wound. *Touches the wound.
Wash hands using standard precautions techniques.
Venous Blood Collection
ABOUT THIS PRESENTATION For Instructor Use Only
Allergic Reaction Protocol Preparing & Administering Epinephrine IM
INSULIN BY PEN 12/2008.
Diabetes Care Tasks at School: What Key Personnel Need To Know
INSULIN BY SYRINGE AND VIAL 12/2008.
Home Use Fingerstick Technique Training
Diabetes Care Tasks at School: What Key Personnel Need To Know
INSULIN BY SYRINGE AND VIAL 12/2008.
Contraceptive Implants Session V A: Two-Rod Implant Insertion
Contraceptive Implants Session IV A: One-Rod Implant Insertion
INSULIN BY SYRINGE AND VIAL 12/2008.
Contraceptive Implants Session IV B: One-Rod Implant Removal
The 4th Family Medicine Review Course
Putting Allergy injections
Contraceptive Implants Session V A: Two-Rod Implant Insertion
INSULIN BY PEN 12/2008.
Presentation transcript:

Gail Vanairsdale Global Clinical Education Manager Enlite Sensor Insertion

2 | For Internal Use Only Enlite Sensor Insertion Objectives 1 Identify necessary supplies and system components 2 Describe appropriate insertion sites and technique for inserting Enlite sensor Complete successful Enlite sensor insertion into model abdomen 3 At the completion of this session, participants will:

3 | For Internal Use Only Patient Training Video

4 | For Internal Use Only Gather Supplies Enlite™ Sensor Enlite™ Serter MiniLink® transmitter Alcohol wipe Sensor overtape Sharps container

5 | For Internal Use Only Prepare to Insert Wash your hands. 7B7B 1

6 | For Internal Use Only Prepare to Insert 5 centimeters from your injection site 5 centimeters (2 inches) from your navel 5 centimeters (2 inches) from your insulin pump infusion site 7.5 centimeters (3 inches) from any manual insulin injection site 2 Select appropriate insertion site Note: Clinical trials for glucose sensors were performed on sensor inserted in the areas shown above

7 | For Internal Use Only Prepare the Site Clean insertion site with alcohol. Let it air dry. 3

8 | For Internal Use Only Open the Sensor Package Open the sensor package. Remove the pedestal from the package. Place the pedestal on a flat surface, such as a table. 4 5

9 | For Internal Use Only Push Serter onto Pedestal Push the Serter down until the base of the Serter sits flat on the table. 6 7

10 | For Internal Use Only Detach Serter from Pedestal To detach the Serter from the pedestal, place two fingers on the pedestal arms and slowly pull the Serter straight up. Do not detach the pedestal from the Serter in mid-air, as this might damage the sensor. 8

11 | For Internal Use Only Place Serter on Site Place the base of the Serter flat against your insertion site. 9 WARNING: Never point a loaded Serter toward any body part where insertion is not desired

12 | For Internal Use Only Inserting the Enlite Sensor 10A 10B 10C 10D

13 | For Internal Use Only Remove Needle Housing 11 Gently hold the base of the sensor against the skin. Hold the needle housing at the top and slowly pull straight out, away from the sensor. Dispose of the needle housing in a sharps container after a single use. Do not clean or resterilize, and do not try to extract the needle from the needle housing. WARNING: If bleeding occurs, apply steady pressure using sterile gauze or a clean cloth for up to three minutes

14 | For Internal Use Only Sensor Adhesive Tape Straighten the sensor adhesive tape so that it lies flat against the skin While holding the sensor in place, gently lift the adhesive tab. Carefully remove the bottom piece of white paper from under the adhesive pad. Press the adhesive against the skin.

15 | For Internal Use Only Apply the Sensor Overtape 14 3 Before connecting the device, apply overtape. Do not cover the adhesive tab (1) or sensor connectors (2) with overtape (3).

16 | For Internal Use Only Connecting the Device Connect the device to the sensor. NOTE: Overtape is not shown in steps 15-19

17 | For Internal Use Only Cover with Sensor adhesive tab Cover the device with the sensor adhesive tab.

18 | For Internal Use Only Skill Practice Table lead will guide you through process Two participants at a time will insert sensors, apply overtape, and attach MiniLink, using model abdomen. Do NOT insert sensors into yourself, each other, or other living beings When you have completed your practice, remove your sensors from models and place into sharps container. The next pair of participants will then insert sensors.