SUPPORT FUNCTION 1-1. SBS installation will be done same time by product specialist. 1-2. Loading & Unloading will be taken care for safe handling of.

Slides:



Advertisements
Similar presentations
Selling Inoculants Module One – How are your Cows?
Advertisements

Safety in the Drafting Lab
Easi-Sterilise Standard Operating Procedures & Workplace Skills Assessments Getting it right, every step of the way.
East Carolina University Compressed Gas Safety Training Program
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Refrigerators.
WIRED TYPE MULTI ZONE FANCOIL CONTROL SYSTEM MODEL : WSF- 700 SYSTEM
The pumps should be tightened about once a month. If a new pump is installed, the pump should be initially tightened and then re-torqued one week later.
Sand Sampler User’s Manual Introduction Things to Know Before Starting your Sampler Starting and Operating Troubleshooting Maintenance.
Installation. Indoor Unit Installation Typical Installation.
ATLIER FRANCOIS (COMPRESSOR). MAINTENANCE AND CHECKS DAILY CHECKS DAILY CHECKS INSPECT AND NOTE THE OIL LEVEL AND ALL THE PRESSURE AND TEMPERATURE LEVELS(FILLL.
① The output signal of a room thermostat is ON or OFF according to changes of room temperature ② The power supply to a motorized valve is ON or OFF according.
MyLock 644D Service Seminar.
Back & Lifting Safety By: Forestry Mutual Insurance Company.
Finally, a compressed air piping system so simple…it’s EZ!
1 Oil Fuel Line De-aerators What they are, what they do and how to install.
HACCP and GMP in school restaurants School Development Project STORING AND KEEPING FOODSTUFFS.
Condensation Piping and Installation Drain Pans
PEUGEOT 206 INSTALLATION 99’— 05’ TU5JP4
Fire Electrical Back Security
Pump Installation Vigyan Ashram, Pabal.
Electrical Power Systems
Installation. Indoor Unit Installation Typical Installation.
FALL PROTECTION. WHY? –BECAUSE: Falls accounted for 10% of fatal work injuries in 1994 & Serious hazards can be present while above ground. –Examples:
Presentation on Installation of a Domestic Cold Water Storage Cistern
Next Slide Introduction to the Drill Press Created by Mr. Heck.
MAKE SURE YOUR OWN ACTIONS REDUCE RISKS TO HEALTH AND SAFETY.
Best sensitivity in the world. ( Lux F# IRE) Best sensitivity in the world. ( Lux F# IRE) 700 TV line in B/W and 600 TV line.
Perfect solution for large building
Installation. Indoor Unit Installation Typical Installation.
Kitchen design What’s wrong with this picture?. He can’t see what’s in the pans! Are all chefs the same height? Are people all the same height? Which.
Settings & Adjustments. Settings & Adjustments.
BUILDING MATERIAL BUILDING MATERIAL PALESTINE UNIVERSITY chapter No.#7 Mechanical Works Dr. Ali Ibrahim Tayeh.
INSTALLATION & COMMISSIONING. 5WSS Installation Hanging the Unit Hanging the Unit Location Considerations Location Considerations Refrigerant Piping Refrigerant.
1 HVACR316 - Piping Safety Solder and Braze Joints Safety Solder and Braze Joints.
Set Up for Live Streaming Video This presentation will walk you through the set up and delivery for streaming video of a live event over the internet.
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
Framed Canopy Fitting Instructions Contents – 6- Angled frame fixing brackets 1 x handle pack 6 x self drilling tech screws 3 keys 1x door 6 x coach screws.
Chapter 5 DefensiveDriving Standard Accident-Prevention Formula Be Alert - Never think the other driver will not make a driving mistake. Be Prepared.
1 HVACR316 - Piping Safety Solder and Braze Joints Safety Solder and Braze Joints.
Natura Water Machine B and D Series 3 – Dispense tower plumbing kit Kit number Kit includes components used for both Natura B and Natura D series.
The Flow of Food: Storage
Fabrication of Fishtank Reservoir ENGR 121 living with the lab.
Dental radiology د. باسم الاعسم.
Direct Hot Water. What Cold Water System is Pictured? What hot Water System is Pictured?
1 Product Presentation January Normal BinROXELL Bin Old feed Normal bin: ‘centerflow’ feed flows first in center  bridging ‘mass flow’ feed.
1  2008 Kaeser Compressors, Inc., USA (V2.2) “Specifications are subject to change without notice” Presenting... Kaeser Omega Blowers.
Horizon Icemaker for Vision Satellite-fill Installation Installation Best Practices To navigate through the presentation, press the → and ← keys on your.
© 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. Bad case of Installation RAC-B-A07.
Powered Industrial Trucks: Forklifts—Overhead Transparencies © 1998 Comprehensive Loss Management, Inc. 1 Powered Industrial Trucks.
Planned Preventive Maintenance for Fridges To improve your fridge’s function do the following tasks all the time: 2) Defrost your fridge once a month OR.
ARÇELİK TİCARİ KLİMA EĞİTİM DÖKÜMANI APPENDIX.
INSTALLATION MANUAL FATL Machine Installing: ACTIVITY CHECK POINT 1. Minimum two persons required for opening the Machine. 2. Cut the straps & tape. 3.
"This document can not be used without Samsung's authorization"
Scorpion is a remote tester specifically designed for testing ASD systems. Scorpion is compatible with the FAAST aspirating smoke detector. It is particularly.
ENGINE MODE CODES.
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
"This document can not be used without Samsung's authorization"
Product Presentation January 2010.
"This document can not be used without Samsung's authorization"
Chapter 10 Sanitary Facilities and Equipment
Microscope Basics T. Trimpe
East Carolina University Compressed Gas Safety Training Program
LEGEND High press Low press Liquid vapour mixture
By: JAGDEEP SANGWAN Refrigeration Basics 101.
Presentation transcript:

SUPPORT FUNCTION 1-1. SBS installation will be done same time by product specialist Loading & Unloading will be taken care for safe handling of product Demo will be covered by product specialist after the complete installation.

SBS REF INSTALLATION PROCESS

PREPARATION BEFORE INSTALLATION 1. Entrance Check 1-1. Check if the ref goes through the entrance. MODELDIMENSIONS (A-B-C-D-E-F) REF VPP60ZPS-FSC651*65*25*655*942*1808 REF VPL60ZPS-FSC600*57*5*675*908*1760 REF VPS65ZLM-FSC600*57*5*675*908*1760 Fridges with more than 750mm of “D” are not able to go into the elevator. So, disassemble the doors or use a ladder car.

HOW TO DELIVER & UNPACK THE PRODUCT 1. Loading/Unloading of Ref. Loading Unloading Transporting 1-1. Loading When loading products, make sure to use fork lifts and work by 2 personnel as a team Transporting To prevent products from moving freely, fix the products with rubber bands Unloading When unloading products, also make sure to use fork lifts and work by 2 personnel as a team. Make sure that products shall not be bumped on the corners and fallen down.

Space Procurement Cover Disassembly 2-1. Space Procurement Secure enough space to remove the packaging box Removing packing box Be careful not to scratch the product with EPS or Angle and make sure to check the outer appearance after removing all packaging materials Disassembling Front Cover Open the F/R-Doors, remove screw caps (3ea) and remove the Front Cover screws (3ea) by turning them counter-clockwise. For the dispenser model, remove the water pipe clamping clip. Detach the front cover first before moving the ref after removal of the packaging box. Package Removal HOW TO DELIVER & UNPACK THE PRODUCT

PRECAUTION BEFORE INSTALLATION 1. Delivery 1-1. Upon loading/unloading the ref, make sure that 4 personnel work as a team Upon delivery, make sure to use protection materials preventing any damage Move the ref carefully after getting rid of the packaging box. 2. Installation 2-1. Check if the floor is leveled. If the floor is not leveled, it causes vibration and noise, and when opening/closing the doors, the refrigerator could be tipped over resulting in personal injuries For dispenser models, select a place easy to access the water supply with little humidity Install the set maintaining adequate distances from the surrounding. If there is not enough space around the set, power consumption will be increased due to weak cooling power caused by insufficient ventilation Keep it away from places with direct sun light, much heat or too low temp. A place with a surrounding temp ranging from 5 ℃ to 43 ℃ is recommended. A place with too high/low temps causes problem and affects cooling power.

PRECAUTION BEFORE INSTALLATION 3. Function Check 3-1. Carry out a water leakage test after completing the water supply connection. 1) Let more than 1.2L water flow by pressing the Water Lever. 2) Let water pass by pressing the Ice Maker Test button for 3 times repeatedly. 3) Check for any water leakage in the order of Water Connector/ Water Tube Valve/ Inlet & Outlet of Water Valve and Coupler at the lower part of the door Check if the ref is leveled and there are no level differences between the doors. 1) Check if the ref is rocking and the adjusting legs are completely set on the floor. 2) Check if there are level differences of doors and if any, adjust it with the adjusting bolt Check if the room lamps work normally.