Q-Exactive LC-MS. TurboFlow technology - Special columns - Complex valving - Extra pump UHPLC -Fast separation -Best separation.

Slides:



Advertisements
Similar presentations
Protein Quantitation II: Multiple Reaction Monitoring
Advertisements

Improvements in Mass Spectrometry for Life Science Research – Does Agilent Have the Answer? Ashley Sage PhD.
Welcome! Mass Spectrometry meets Cheminformatics Tobias Kind and Julie Leary UC Davis Course 7: Concepts for LC-MS Class website: CHE Spring 2008.
Pesticide screening LC-QTOF, Agilent. National Food Institute, Technical University of Denmark Disposition National Food Institute –EURL –NRL –Personale.
How Can Orbitrap Technology Help My Food Safety Analysis?
Chapter 1 Introduction Analytical Chemistry deals with methods for determining the chemical composition of samples. Qualitative Analysis (identification)
* CORRESPONDING AUTHOR Bioanalysis of Exenatide: Intact Versus Signature Peptide Approach to Reach Optimal Sensitivity in Large Molecule Quantification.
Chem. 133 – 4/28 Lecture. Announcements Lab Report 2.3 due Today Pass back graded materials (lab reports 2.2, Q5, and AP3.1) Today’s Lecture Mass Spectrometry.
LC-MS Based Metabolomics. Analysing the METABOLOME 1.Metabolite Extraction 2.Metabolite detection (with or without separation) 3.Data analysis.
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
HOW MASS SPECTROMETRY CAN IMPROVE YOUR RESEARCH
Russell Rouseff FOS 6355 Summer 2005 What is Mass Spectroscopy Analytical Chemistry Technique Used to identify and quantify unknown compounds Can also.
Proteomics Informatics Workshop Part III: Protein Quantitation
Chemalys September 2009 Chemalys Jan Nordin Chemalys Massworks Extend the Limits of Your LC/MS-System Brukermøte i Massespektrometri 27 mai 2010.
Tryptic digestion Proteomics Workflow for Gel-based and LC-coupled Mass Spectrometry Protein or peptide pre-fractionation is a prerequisite for the reduction.
Orbitrap Technology: New Frontiers in Pesticide Residue Analysis
Center for Human Health and the Environment
© 2010 SRI International - Company Confidential and Proprietary Information Quantitative Proteomics: Approaches and Current Capabilities Pathway Tools.
Bias and Errors. Some Terms Used to Describe Analytical Methods Accuracy Precision LOD RDL LOQ Selectivity Sensitivity Linearity Ruggedness.
Quantitative Insulin Analysis Using Liquid Chromatography–Tandem Mass Spectrometry in a High- Throughput Clinical Laboratory Z. Chen, M.P. Caulfield, M.J.
1 Chemical Analysis by Mass Spectrometry. 2 All chemical substances are combinations of atoms. Atoms of different elements have different masses (H =
Proteomics The science of proteomics Applications of proteomics Proteomic methods a. protein purification b. protein sequencing c. mass spectrometry.
Metabolomics Metabolome Reflects the State of the Cell, Organ or Organism Change in the metabolome is a direct consequence of protein activity changes.
Quality Assurance How do you know your results are correct? How confident are you?
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
Finding a Needle in a Haystack: Using High Resolution Mass Spectrometry in Targeted and Non Targeted Searching for Food Contaminants Erik Verschuuren.
Combining and Choosing Analytical Techniques Chapter 8.
Finnish Custom Lab., Pekka Ravio
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/26/2006Chapter 3ICPMS Interference equations Isobaric.
* CORRESPONDING AUTHOR Glucagon Bioanalysis by LC-MS: “Unprecedented Level of Sensitivity (10pg/mL) for a Novel Formulation” Jean-Nicholas Mess 1, Louis-Philippe.
June 9th, 2013 Matthew J. Rardin June 9th, 2013 Matthew J. Rardin MS1 and MS2 crosstalk in label free quantitation of mass spectrometry data independent.
液相層析質譜分析 LC-MS Method development and Analyte Identification 授課教師:賴滄海教授 授課教師:賴滄海教授
Overview of Mass Spectrometry
Background Aerosols are studied for –Environment impact Direct climate effect Indirect climate effect –Biofuels –Human health impact Medicinal Cigarette.
Separates charged atoms or molecules according to their mass-to-charge ratio Mass Spectrometry Frequently.
Mass Spectrometry Quantitative Mass Spectrometry
Metabolomics MS and Data Analysis PCB 5530 Tom Niehaus Fall 2015.
Chem. 133 – 2/16 Lecture. Announcements Lab today –Will cover last 4 set 2 labs + start on set 2 labs –Lab Report on electronics labs – due 2/23 (I planned.
Deducing protein composition from complex protein preparations by MALDI without peptide separation.. TP #419 Kenneth C. Parker SimulTof Corporation, Sudbury,
Chem. 133 – 4/26 Lecture. Announcements Return graded quiz and additional problem Lab – Lab report deadlines (2:4 – Thursday) Today’s Lecture – Mass Spectrometry.
Metabolomics Workshop
Toxicological Screening of 80 Drugs in Urine Using the High Resolution Exactive LC/MS Orbitrap Mass Spectrometer Coupled to Online Extraction and Turbulent.
The world leader in serving science For Research Use Only. Not for use in diagnostic procedures Quantitative Analysis of 4 Immunosuppressant Drugs in Whole.
DIA Method Design, Data Acquisition, and Assessment
Protein quantitation I: Overview (Week 5). Fractionation Digestion LC-MS Lysis MS Sample i Protein j Peptide k Proteomic Bioinformatics – Quantitation.
Objective  To develop methods for analysis of compounds in organic aerosol particles Why is this important?  Environmental impact  Alternative fuels.
The world leader in serving science Alternate Channels Meeting 12 th June 2007 Tom Whitehouse European Commercial Marketing Manager Small Molecules.
Introduction to Liquid Phase Mass Spectrometry
Quantitation using Pseudo-Isobaric Tags (QuPIT) and Quantitation using Pseudo-isobaric Amino acids in Cell culture (QuPAC) Parimal Samir Andrew J. Link.
RANIA MOHAMED EL-SHARKAWY Lecturer of clinical chemistry Medical Research Institute, Alexandria University MEDICAL RESEARCH INSTITUTE– ALEXANDRIA UNIVERSITY.
Evolution GC-MS/MS: Pesticide analysis in canola oil Evolution GC-MS/MS: Pesticide analysis in canola oil Vivian Watts 1, Ingo Christ 1, Mark Misunis 2.
Forensic Toxicology Use Only Analysis of ETG, ETS using the Thermo Scientific Exactive Mass Spectrometer Kent Johnson Fortes lab, Portland Oregon.
Yonsei Proteome Research Center Peptide Mass Finger-Printing Part II. MALDI-TOF 2013 생화학 실험 (1) 6 주차 자료 임종선 조교 내선 6625.
Target Analyses in Parallel Reaction Monitoring Mode (PRM)
Plasma Free Metanephrines Analysis using LC-MS/MS with Porous Graphitic Carbon Column Xiang He (Kevin) and Marta Kozak Thermo Fisher Scientific.
Metabolomics Part 2 Mass Spectrometry
Multi-Analyte LC-MS/MS Methods – Best Practice.
Metabolomic Profiling in Drug Discovery: Understanding the Factors that Influence a Metabolomics Study and Strategies to Reduce Biochemical and Chemical.
LC-MS/MS Identification of Impurities Present in Synthetic Peptide Drugs Dr Anna Meljon*, Dr Alan Thompson, Dr Osama Chahrour, and Dr John Malone Almac.
For Forensic Toxicology use Only
For Research Use Only. Not for use in diagnostic procedures
Metabolomics Part 2 Mass Spectrometry
Protein/Peptide Quantification
Chem. 133 – 2/16 Lecture.
Peter Kovarik and Yves LeBlanc
High Resolution Quantitation of Microcystins with SCIEX X500R QTOF System KC Hyland.
Presentation Title NEMC 2018 Dale Walker, Bruce Quimby Agilent
Metabolomics: Preanalytical Variables
1.0 Basic Concepts and Definitions
Shotgun Proteomics in Neuroscience
Presentation transcript:

Q-Exactive LC-MS

TurboFlow technology - Special columns - Complex valving - Extra pump UHPLC -Fast separation -Best separation

fewer sample prep steps with TurboFlow technology

Why TurboFlow columns are different: Duality Chemistry C18 C8 Ion Exchange Cyclone P Cyclone 12 different types For targeted analyses, not profiling - yet Size Exclusion Turbulence within column Velocity faster than diffusion on large molecules Bimodal Separation on One Column

Turboflow column

A 10,000-fold dilution of. matrix B TurboFlow Method C Generic SPE D Protein Precipitation ABCD 1 mm, 4-12% Bis-Tris gel 20 μL applied Equivalent matrix amounts applied Cleaner Plasma Extracts

Tetracycline at 500 pg/ml with TLX vs HPLC in Pig Liver Matrix HPLC TLX TLX Sample shows removal of interference compared to standard HPLC! Courtesy of Dr. Charles Yang

Leuco Malachite Green at 50pg/ml in Pig Liver HPLC vs TLX turboflow HPLCTLX Aria TLX Sample shows improved S/N and removal of chemical noise! Courtesy of Dr. Charles Yang

Rat Plasma Buffered H20 50:50 MeOH:H20 TLX System With TurboFlow method has less ion suppression than other 2 methods PPT 4:1 MeOH/H20 SPE [J. L. Herman, Cephalon, Inc., Brandywine Parkway, PA] Reduce Ion Suppression Effects SPE, PPT and TurboFlow method comparison A B c

 Ubiquitous (all species)  Concentrated (mg/ml in plasma)  Relatively late-eluting  Surfactants –“matrix effectors”  Strongly retained (ghost peaks)  Unstable –degrade to fatty acids and head groups Ref: K. C. Van Horn, Tandem Labs, BSAT Presentation 2006 Phospholipids – ion suppression

Times Less Phospholipid Sample precipitation enhances extraction of endogenous phospholipids Direct injection of plasma results in a 1000-fold reduction in phospholipid signal A: PPT B: direct TurboFlow method

Accela Q Exactive R = 70,000 All compound elute in 2mins, with peak width of 0.04 mins = 9 scans under the peak UHPLC: 60+ pesticides in 2 mins, 4s wide peaks, Full scan

Instrumentation: Q Exactive Quadrupole Mass Filter HCD Collision Cell S-lens C-trap Spectrum Multiplexing Orbitrap Enhanced FT

Q-Exactive specs Mass Resolution – up to m/z 200 Scan speed decreases with resolution Up to 70,000 Res. at UHPLC speeds Resolution decreases as mass increases Very high resolution for small molecule analyses Mass accuracy < 5 ppm; usually < 2 ppm With external calibration Mass range 50 – 6000 m/z Scan speed – 12,000 amu / second Sensitivity in ppt range Dynamic range

SIM Signal visibility is dependent on whether a signal is visible above the spectrum noise Spectrum noise is dependent on the ratio of compound within a certain ion population Relative Abundance N= N= NL: 1.94E8 [ ] NL: 1.12E8 [ ] Full MS SIM (10amu) S/N = 745 S/N = 5400 Lowest detected signal/scan Lowest detected signal/scan Gain in sensitivity (7x) Sensitivity gain 5 – 10 x with SIM mode Caffeine

Long-term Mass Accuracy with External Calibration 3° C Realistic conditions of an average lab Temperature variations up to 3°C peak-to-peak, up to 1°C/hour

Q Exactive – functions FunctionWhat for?Information Full scan Positive or negative ions Qualitative screening Quantitation Accurate mass SIMQuantitation of knownsVery low concentration In-source CIDQualitative screening Quantitation Accurate mass with extra confirmation and structure information. CID + MS 2 MS 3 structure info.Accurate mass with extra confirmation and structure information. MS 2 in HCD cell; All Ions Fragmentation, Data Dependent or targeted like QQQ Qualitative screening Quantitation Accurate mass with extra confirmation and structure information.

Target or Non-Target analysis workflow SAMPLE Target Analysis Non-Target Analysis Quantitation Target screening ? Profiling Fingerprinting Authenticity Identification Quantitation Q-Exactive Triple Quad HR/AM

 Metabolomics  A comprehensive analysis of all metabolites  A measure of the fingerprint of biochemical perturbations – pattern recognition  Useful when you don’t know what to expect  Hypothesis generation  Targeted Analysis  Metabolite target analysis  E.g. Analysis restricted to metabolites of an specific enzyme system that is known to be affected by a certain perturbation  Metabolite profiling  E.g. Analysis focused on a class of compounds associated with a particular pathway  Only find what you are looking for Metabolomics analyses possibilities

m/z window = ± 1 Da [M+H] + m/z z =+2 5 >1,000,000 data points ~100,000 extracted ion peaks Peak area ranges ~ 7 orders Much irrelevant data Much redundant data High quality data from the Orbitrap allows for more precise automated data processing Need to be able to reduce the data to chemical entities Anatomy of a UHPLC + Orbitrap Data Set +4+4

Software for Q Exactive Xcalibur for data acquisition & initial processing SIEVE for handling large LC-MS data sets; differential analysis, trend evaluation; discovery ExactFinder for searching external data bases; unknown screening & routine targeted analysis MetWorks for metabolic samples; searches for biotransformations Mass Frontier for structural elucidation Proteome Discoverer for proteomics data; qualitative & quantitative ToxID for automated screening for known compounds

= Analyte signalsSample ~98% of lower intensity signals are eliminated - Solvent blank Chemical: Background Subtraction

SIEVE: Removing Noise from Statistics FastedFed Female Male Components Loss of group separation m/z Peaks Increased intra group variability

Q-Exactive UHPLC – ultimate separation TurboFlow - targeted analyses in bio matrices with little prep Accurate mass, very stable, MS/MS Margaret Coe