Senior Project – Electrical Engineering- 2009 Biofeedback Training System for Improved Athletic Performance Matt Statton Advisor – Professor Helen Hanson.

Slides:



Advertisements
Similar presentations
CHAPTER 3: SPECIAL PURPOSE OP-AMP CIRCUITS
Advertisements

INTRODUCTION With this chapter, we begin the discussion of the basic op-amp that forms the cornerstone for linear applications; that is, the signal is.
ENTC 3320 Absolute Value.
NuTek® Devices.
Biofeedback Jennifer L. Doherty-Restrepo Entry-level Athletic Training Education Program PET 4995: Therapeutic Modalities.
Mark Neil - Microprocessor Course 1 Digital to Analog Converters.
Team 03 Department of Electrical and Computer Engineering 20 November 2014 Digital Fitness Trainer MDR.
Using an FPGA to Control the Protection of National Security and Sailor Lives at Sea Brenda G. Martinez, Undergraduate Student K.L. Butler-Purry, Ph.D.,
ABSTRACT The goal of this project was to create a more realistic and interactive appliance interface for a Usability Science class here at Union. Usability.
Weather Station Project Wind Speed Wind Direction Temperature Light/Dark Sensor 1.
ECE 201 Circuit Theory I1 Introduction to the Operational Amplifier μA 741 OP AMP.
Operational Amplifier
Electrical and Computer Engineering iLights Nick Wittemen, EE Chris Merola, EE José Figueroa, EE Matt Ryder, EE Comprehensive Design Review.
Lecture161 Instrumentation Prof. Phillips March 14, 2003.
A Solder Reflow Oven Dylan Gifford David Cobler. A typical $30,000 Reflow Oven Solder Paste Surface Mount Technology.
Department of Information Engineering357 Operation amplifier The tail, large impedance gives high CMRR Mirror as active load. High gain Follower as buffer.
Example Problem You are measuring the EEG of a patient and accidently choose two different types of electrodes for EEG lead. One of them has a source impedance.
Introduction AD620 Instrumentation Amplifier
Department of Information Engineering357 Feedback Op amp golden rules Approximations: 1.Voltage difference between the two inputs is zero 2.Input draws.
Operation Amplifier. Golden Rules of OP Amp 1.i in =0, no current flow into op amp. 2.V + =V - Typically one end of op amp is connected to ground, therefore,
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. Chapter 14 Operational Amplifiers.
Op-Amp Oscillator. Reading Schematics: Battery What’s this?
Conceptualizing and Constructing the Smart Speaker: Designing a power-limiting device for the common 2-way loudspeaker. Presented by: Ryan Gwinn – Project.
Operational Amplifiers
Senior Project – Computer Engineering Integrated Workout Shoe Peter Katlic Advisor – Prof. Cotter Development: Consisting of an 8051 microcontroller.
LABORATORY SIX Skeletal Muscle Physiology 1. Contraction of a Skeletal Muscle Begins with electrical excitation of muscle, called a stimulus The stimulus.
Solar Powered Battery Charger
TECHNOLOGY DEMONSTRATOR OF 7-CHANNEL DIGITAL FLIGHT DATA RECORDER AS AVIONICS TEACHING AID USING STATIC MODEL AIRCRAFT Authors 1. Wg Cdr Nikhil Verma,
Group Members: Brad Cox Kevin Burkett Tera Cline Arthur Perkins CS10 Battery Management System.
Lab #5 Overview Activity #1 - Simulation of an Op-Amp inverting amplifier Activity #2 - Build and Test the Op-Amp inverting amplifier Activity #3 - Determining.
Ch4 Electronic Components Circuit/Schematic Symbols.
Fall CS-EE 480 Lillevik480f04-l1 University of Portland School of Engineering Project Swift Fox Design Review 21 Jan 2005 Peter Brunke Andrew Robinson.
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Fourth Edition, by Allan R. Hambley, ©2008 Pearson Education, Inc. Lecture 7 Amplifiers.
Pediatric Dynamometer ABSTRACT The Children’s Hospital of the University of Pennsylvania has long been involved with the study of the correlation between.
ENGR 104: Data Acquisition Lecturers: Dr. Binh Tran Dr. Otto Wilson Jr. © The Catholic University of America Dept of Biomedical Engineering.
1 Skolnik’s Op Amps 101 Challenge Try our brainteaser and have some fun! Press “page down” to continue.
OxCart: Oxygen Concentrator and Analyzer for the Developing World Matt Amdahl, Ryan Le, Dan Nelson, Jay Patel, Abe Segura Department of Bioengineering,
Feedback: Part C – Oscillators Slides taken from:
Senior Project – Electrical Engineering Amateur Radio Repeater Daniel Harkenrider Advisor – Professor James Hedrick Abstract There are a number.
Team 03 Department of Electrical and Computer Engineering 15 October 2014 Digital Fitness Trainer PDR.
ECE-498 Matt Statton Advisor: Professor Hanson.  Goals of athletic training ◦ Muscle hypertrophy through stimulation  Muscle fatigue during a specified.
Design of Digital-to-Analog Converter Qin Chen Yong Wang Dept. of Electrical Engineering Mar. 14th, 2006 EE597G Presentation:
Solar Power Array Management for the Solar Racing Team Mark Calotes Ginah Colón Alemneh Haile Nidhi Joshi Michael Lu School of Electrical and Computer.
EMLAB 1 Chapter 4. Operational amplifiers
Team 03 Department of Electrical and Computer Engineering 6 March 2015 Digital Fitness Trainer CDR.
Automatic accident avoiding system PROJECT MEMBERS MUTHUKUMAR.K (05ME33) SAKTHIDHASAN.S (05ME39) SAKTHIVEL.N (05ME40) VINOTH.S (05ME56) PROJECT GUIDE:
Non - Inverting Amplifier
Programmable Biofeedback Chest Exerciser Eileen Bock, Lauren Cassell, Margaret Gipson, Laurie McAlexander Department of Biomedical Engineering, Vanderbilt.
In and Out Line Monitoring System for Volleyball Kelley White Advisor: Professor Buma.
Mark Neil - Microprocessor Course 1 Digital to Analog Converters.
Voltage Divider Circuits Input transducers Input transducers are devices that convert a change in physical conditions (for example, temperature) into a.
Electronics: Basic to clinical Karl E Misulis MD,PhD.
Solar Power Charge Controller. Solar Power Charge Controller Introduction  A charge controller, or charge regulator is basically.
Muscle Fatigue Interface Final Presentation Shay Chen, Tushar Bhushan, Roman Levitas TA: Lydia Majure ECE 445: Senior Design Project #30 April 1, 2013.
Senior Capstone Design Project – Electrical Engineering – 2016 In and Out Line Monitoring System for Volleyball Kelley White Advisor: Professor Buma DESIGN:
Autonomous Wheelchair Tyler Morton & Ben Hoerst Senior Design Advisor: Dr. Stanislaw Legowski Project Advisor: Dr. Steven Barrett ECE Senior Design.
5-3-2 The Emitter Follower. Learning Objectives: At the end of this topic you will be able to;
Drum Tutor Lite Yuanheng Yan Xun Yu Zhen Qin ECE 445 Senior Project Group 43 December 3,2015.
BIOPOTENTIAL AMPLIFIERS
Feedback: Part C – Oscillators Slides taken from:
Chapter 10: Operational Amplifiers
Pulse Rate Monitor Ying Wang
Absolute Value.
Feedback No feedback : Open loop (used in comparators)
Operational Amplifiers
Examples of Negative Feedback Applications: A) Inverting Amplifiers
ELECTROMYOGRAPHICAL COMPRESSION SHORTS TO PREDICT LACTATE THRESHOLD
Example Example 1: An electric lamp is rated 110 W, 200 V. When the lamp is operated at its rated power and voltage, calculate a) the current flowing through.
Presentation transcript:

Senior Project – Electrical Engineering Biofeedback Training System for Improved Athletic Performance Matt Statton Advisor – Professor Helen Hanson Abstract: The goal of this project is to produce a biofeedback training system that leads to improved athletic training. Electrical signals produced by muscles when they contract, measured by an electromyograph, are used as an indicator of muscle fatigue. The measured signals are processed using a microcontroller, which analyzes the signals and provides a feedback response to the user when the amplitude gets below a certain threshold. In the end, a biofeedback training system was produced that can help people of all ages and fitness levels maximize their benefits from exercise, reach their goals faster, and improve their health. Electromyograph: A MAX666CPA voltage regulator was used to regulate voltage from a 9V battery to 5V to power the operational amplifiers. An LT1494 operational amplifier, with gain A = 1, was used to create a virtual ground of V CC /2 = 2.5 V. An INA106 differential amplifier, with internal gain A = 10, was used to amplify the differential input from two surface electrodes placed on the proximal and distal portions of the muscle. External resistors were used to increase the gain to A = 110. The electromyograph was created using an LPKF ProtoMat C20S circuit board plotter from a schematic made in EagleCAD. All parts were soldered into the board created by the circuit board plotter. The inputs were connected to electrode leadwires, and the output was connected to the 8051 microcontroller for processing. Design Requirements: Measure electrical signals from muscles Use electrodes to measure electrical signals Amplify signal so it can be analyzed Analyze signal to determine level of muscle fatigue Analog-to-digital conversion of signal from muscle Measure maximum and relative maximum amplitude peaks of signal Determine threshold at which muscle fatigue occurs Compare relative maximum to absolute maximum of signal to determine level of muscle fatigue Provide feedback response to user when muscle fatigue occurs Signal Processing: The electromyogram was analyzed using a Silicon Labs C8051F020 microcontroller. After analog-to-digital conversion using the on-board 12-bit analog-to-digital converter, the microcontroller was programmed to measure the average amplitude of the signal during the first repetition. A running average of the following repetitions was compared to the initial average, and a feedback response was provided to the user when the running average reached a threshold of muscle fatigue based on the initial average. Results: The electromyograph measured the electrical activity of the muscles. However, the microcontroller has not yet been able to consistently measure muscle fatigue based on the amplified electromyogram data. Further work is being done to enable the microcontroller to more accurately measure the level of muscle fatigue of the user. Acknowledgments: Professor Hanson Professor Hedrick Ben Bunes Internal Education Fund Figure 1: EagleCAD schematic designed based on circuit diagram from s/s2005/bsm24_ajg47/website/website/index.html Figure 3: Front of electromyograph circuit Figure 4: Back of electromyograph circuit Figure 5: Flow chart of electromyograph signal analysis program Figure 6: Measured Electromyogram signal displaying fully contracted, minimally contracted, and resting biceps muscle Figure 2: EagleCAD board file created from schematic