Automatic Control System

Slides:



Advertisements
Similar presentations
Chapter 10 Stability Analysis and Controller Tuning
Advertisements

Chapter 10: Frequency Response Techniques 1 ©2000, John Wiley & Sons, Inc. Nise/Control Systems Engineering, 3/e Chapter 10 Frequency Response Techniques.
Frequency Response Techniques
CHE 185 – PROCESS CONTROL AND DYNAMICS
Chapter 8 Root Locus <<<4.1>>>
Chapter 7 System Compensation (Linear Control System Design)
Control System Design Based on Frequency Response Analysis
Frequency Response Methods and Stability
Transient and steady state response (cont.)
Lecture 9: Compensator Design in Frequency Domain.
Dr. / Mohamed Ahmed Ebrahim Mohamed Automatic Control By Dr. / Mohamed Ahmed Ebrahim Mohamed Web site:
Review last lectures.
سیستمهای کنترل خطی پاییز 1389 بسم ا... الرحمن الرحيم دکتر حسين بلندي - دکتر سید مجید اسما عیل زاده.
PID Control and Root Locus Method
Chapter 5 Frequency-Domain Analysis
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
Automatic Control Theory-
1 Chapter 2 We need to write differential equations representing the system or subsystem. Then write the Laplace transform of the system. Then we will.
DNT Control Principle Root Locus Techniques DNT Control Principle.
Compensation Using the process field G PF (s) transfer function.
Unit 5: Feedback and control theory An Introduction to Mechanical Engineering: Part Two Feedback and control theory Learning summary By the end of this.
2-1 (a),(b) (pp.50) Problem: Prove that the systems shown in Fig. (a) and Fig. (b) are similar.(that is, the format of differential equation is similar).
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
Open and closed loop transfer functions. BIBO stability by M. Miccio rev. 3.5 of March 12, 2015.
Professor Walter W. Olson Department of Mechanical, Industrial and Manufacturing Engineering University of Toledo Loop Shaping.
Ch6 The Root Locus Method. Main content §The Root Locus Concept §The Root Locus Procedure §Generalized root locus or Parameter RL §Parameter design by.
Chapter 7 Stability and Steady-State Error Analysis
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
INC 341PT & BP INC341 Frequency Response Method (continue) Lecture 12.
Automatic Control Systems
Chapter 11 1 Stability of Closed-Loop Control Systems Example 11.4 Consider the feedback control system shown in Fig with the following transfer.
1 Chap 6 The Compensation of the linear control systems P553.
Chapter 6: Frequency Domain Anaysis
Frequency Response OBJECTIVE - Bode and Nyquist plots for control analysis - Determination of transfer function - Gain and Phase margins - Stability in.
F REQUENCY -D OMAIN A NALYSIS AND STABILITY DETERMINATION.
自动控制原理 西南交通大学电气工程学院 朱英华 (Catherine) The Principle of Automatic Control.
Chapter 10 Frequency Response Techniques Frequency Response Techniques.
Chapter 3 Dynamic Response The Block Diagram Block diagram is a graphical tool to visualize the model of a system and evaluate the mathematical relationships.
Lecture 17: Introduction to Control (part III)
Chapter 6: Frequency Domain Anaysis
Feedback. 8.4 The Series-Shunt Feedback Amplifier The Ideal Situation.
Lecture 22: Frequency Response Analysis (Pt II) 1.Conclusion of Bode plot construction 2.Relative stability 3.System identification example ME 431, Lecture.
Frequency Response Analysis and Stability
ChE 182 Chemical Process Dynamics and Control
Root Locus Method. Root Locus Method Root Locus Method.
Review. Feedback Terminology In Block diagrams, we use not the time domain variables, but their Laplace Transforms. Always denote Transforms by (s)!
Root Locus Techniques (Sketching Method) Date: 25 th September 2008 Prepared by: Megat Syahirul Amin bin Megat Ali
1 Time Response. CHAPTER Poles and Zeros and System Response. Figure 3.1: (a) System showing input and output; (b) Pole-zero plot of the system;
Exercise 1 (Root Locus) Sketch the root locus for the system shown in Figure K 1 (
Prof. Wahied Gharieb Ali Abdelaal
Control Systems Engineering, Fourth Edition by Norman S. Nise Copyright © 2004 by John Wiley & Sons. All rights reserved. Figure 10.1 The HP 35670A Dynamic.
Lecture 10 Feedback Control Systems President UniversityErwin SitompulFCS 10/1 Dr.-Ing. Erwin Sitompul President University
CONTROL SYSTEM UNIT-IV Datta Meghe Institute of engineering Technology and Research Sawangi (meghe),Wardha 1 DEPARTMENT OF ELECTRONICS & TELECOMMUNICATION.
Control Systems Lect.3 Steady State Error Basil Hamed.
SKEE 3143 Control Systems Design Chapter 2 – PID Controllers Design
Lecture 11/12 Analysis and design in the time domain using root locus North China Electric Power University Sun Hairong.
1 Chapter 9 Mapping Contours in the s-plane The Nyquist Criterion Relative Stability Gain Margin and Phase Margin PID Controllers in the Frequency Domain.
Feedback Control System THE ROOT-LOCUS DESIGN METHOD Dr.-Ing. Erwin Sitompul Chapter 5
Page : PID Controller Chapter 3 Design of Discrete- Time control systems PID C ontroller.
EE4262: Digital and Non-Linear Control
Time Domain and Frequency Domain Analysis
Automatic control systems I
Nyguist criterion Assist. Professor. Dr. Mohammed Abdulrazzaq.
Frequency-Domain Analysis and stability determination
Frequency Response Techniques
Frequency Response Techniques
Chapter 8. Frequency-Domain Analysis
Frequency Domain specifications.
Frequency Response Techniques
The Frequency-Response Design Method
Presentation transcript:

Automatic Control System IV. Time domain performance Stability

Transfer functions of closed loop Gw(s) Gr(s) Gc(s) Ga(s) Gp1(s) Gp2(s) Gt(s)

Steady-state characteristic of the feedback system WP2 y(t) t WP1 Dynamic response of the feedback system R The unit step response of the feedback systems shows the quality parameters in time domain. r(t) t

Time domain performance specification (rv-fv) = Steady-state error 90% Tolerance band Second peak value (spv) Settling time Rise time 10% Final value (fv) of response It’s 100% Peak value (pv) Required value of response (rv)

Stability of a closed loop system Definition of stability of linear system: Energised the closed-loop system input a short impulse which move the system from it’s steady-state position and wait. When the transient response has died and the system remove the original position or remain inside a predicted defined small area of the original position the system is stable and linear. Definition of stability of non-linear system: Energised the closed-loop system input a short impulse which move the system from it’s steady-state position and wait. If the system remove and remain inside a predicted defined small area of the original position the system is stable. If the transient response hasn’t died the system is unstable.

Stability examination from closed loop transfer function Unit feedback model r(s) y(s) A dynamic system is stable if the transient part of the differential equitation has died. It means the real part of the roots of the characteristics equitation have negative value. If  negative. The denominator of the operator transfer function is very similar to the characteristic equitation and the roots are the same.

Continuation of stability examination from closed loop The transient solution is given bz the roots of the differential equation’s characteristic equation. The roots are equal the denominator of closed loop transfer function and so it gives transient solution too. A dynamic system is stable if the transient part of the differential equitation has died. It means the real part of the roots of the characteristics equitation have negative value. If  negative. The denominator of the operator transfer function is very similar to the characteristic equitation and the roots are the same. 7

Definition of stability in frequency domain The system is stable if the all real part of the roots of denominator of the transfer function is negative. The pi are named the poles and zj are named the zeros

Stability examination from closed loop’s transfer function The root locus diagram Poles and zeros arrangement The root loci depends on the arrangement of poles and zeros and changing a parameter. The default: K runs from zero value to infinite. The loci shows the actual the roots’ positions at actual parameters’ value. Root locus diagram: gyökhely görbe Root loci: gyökhely Poles arrangement of actual value of K

Advantages of stability examination from closed loop’s transfer function Poles and zeros arrangement Minimum damping ratio of the second order parts of transfer function Acceptable region for poles Using the results derived for first and second-order systems enables a bounded design region to be drawn on the s plane within which the poles produce an acceptable performance. Maximum settling time

Stability examination from transfer function of opened-loop Opened-loop transfer function From definition of stability: The frequency at which the open-loop system gain is unity is termed the gain-crossover frequency. The frequency at which the open-loop system phase-shift is -180° is termed the phase-crossover frequency. The system is stable if plots of the opened-loop transfer function at the gain-crossover frequency the phase-shift less than -180° and at the phase-crossover frequency the amplitude gain less than unity. Gain-crossover frequency: vágási frekvencia

Gain margin and phase margin Opened-loop transfer function The gain margin is the reciprocal of open-loop gain at the phase-crossover frequency. Expressed in decibel the gain margins is: -20log(open-loop’s gain at the phase-crossover frequency) dB The phase margin is the difference of the phase-shift of the system and -180° at the gain-crossover frequency. The system is stable if plots of the opened-loop transfer function at the gain-crossover frequency has a positive the phase margin and at the phase-crossover frequency has a positive the gain margin. Gain-crossover frequency: vágási frekvencia

Stability examination from transfer function of opened-loop Plots on j (s) plane is named Nyquist diagram. This is a point on the s plane. If the area of the s plane which is bordered by the positive real axis and the Nyquist plots doesn’t cover this point than the system is stable. Independent plots the amplitude gain and phase-shift on lg axis is named Bode diagram. It is the x axis line on the amplitude plots and the -180 phase-shift line on the phase-shift plots. If the gain and phase margin criterion is true the system is stable.

Advantages of working with Bode plots Bode form of opened-loop transfer function Bode plots of systems in series simply add. Bode’s important phase-gain relationship is given. A much wider range of system behaviour can be displayed on a single plot. Dynamic compensator design can be based on Bode plots.

Using MATLAB Start of stability examination K=1 First using root’s loci. Enabled damping ratio: 0.72, 0.45, 0,23 Secondly using Bode plots. Enabled phase shift: -120, -135, -150 Define the time domain performance specifications.

Summary questions Definition of stability of linear and non-linear systems. Which methods have used the closed-loop transfer function to examine the stability a control system? Which methods have used the opened-loop transfer function to examine the stability a control system? Explain the following terms: phase margin, gain margin. Explain what is meant by the term “dead time” in control and how it may affect the stability of a control loop.