Microfluidic System for Automatic Cell Culture Chun-Wei Huang, Song-Bin Huang, Gwo-Bin Lee Department of Engineering Science, National Cheng Kung University,

Slides:



Advertisements
Similar presentations
Introduction to Pneumatic Components Build a Working Pneumatic Circuit
Advertisements

REPORTED BY: Xela Alexis S. Ibarra III - NEWTON. Hydrostatics – it is the study of this branch of fluid mechanics. Pressure on the walls and dams, and.
Hydraulic and pneumatic systems use fluid power.
Unit 3 Review.
U3f – L3 1. Take out your homework problem worksheet so that we can go over it now. March 17, 2010 DRILL.
Fluid Mechanics.
Mechatronics Department Graduation Project II. OutlineIntroduction. Methodology. Mechanical Design. Control Design.
The bird IPPB machine The Bird is pneumatically powered & controlled.
Design and Simulation of a MEMS Piezoelectric Micropump Alarbi Elhashmi, Salah Al-Zghoul, Advisor: Prof. Xingguo Xiong Department of Biomedical Engineering,
MEMS design and Micro-fabrication Lab MML 2-Dimensional SPR Detection System Integrated with Molecular Imprinting Polymer Microarrays Using Microfluidic.
Chien-Yu ChenMSCL1 A spherical micropump actuated by cultured cardiomyocytes Teacher : Cheng-Hsien Liu Student : Chien-Yu Chen ( 陳鍵瑜 ) Date : 05/16/2007.
Figure 7 Design and Simulation of a MEMS Thermal Actuated Micropump Shiang-Yu Lin, Huaning Zhao, Advisor Prof. Xingguo Xiong Department of Biomedical Engineering,
Safety and Precision of Implanted Intrathecal Pumps December
Introduction to Basic Hydraulics
MONOLITHIC 3-D MICROFLUIDIC DEVICE FOR CELL ASSAY WITH AN INTEGRATED COMBINATORIAL MIXER 陳睿鈞 Mike C. Liu, Dean Ho, Yu-Chong Tai Department of Bioengineering,
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography EECE 491C Unger et al. (Quake group, CALTECH) Science, 2000.
Maastricht, January 25-29, MEMS 2004 Website: Plastic Micropump using Ferrofluid and Magnetic Membrane Actuation C. Yamahata and M.
A PDMS DIFFUSION PUMP FOR ON-CHIP FLUID HANDLING IN MICROFLUIDIC DEVICES Mark A. Eddings and Bruce K. Gale Department of Bioengineering, University of.
1 Lab-On-A-Chip Sensor for On-Site Detection and Sizing of Nanoparticles A. A. S. Bhagat and I. Papautsky BioMicroSystems Research Laboratory
Ventricle Chamber Valve Imaging Chamber ECG Machine Aortic Compliance Chamber Buffer Chamber Secondary Compliance Chamber Flow Meter Pressure Sensors DAQ.
ME8843 The George W. Woodruff School of Mechanical Engineering ME 8843 Advanced Mechatronics Instructor: Professor Charles Ume Introduction to Hydraulic.
Actuators.
Fluid Power Introduction
HYDRAULICS TRAINING MODULE 1. Hydraulic Systems  Transmit power from one point to another Pascal’s Law  Pressure applied on a confined fluid is transmitted.
Control of Pneumatic Energy
Power-Assisted Steering Operation and Service
Chapter 10 Fluid Power Systems.
Development of a Modular Peristaltic Microfluidic Pump and Valve System 3/13/2007 BME 273 Group 20: Adam Dyess, Jake Hughey, Michael Moustoukas, Matt Pfister.
AUTOANALYZER T. Elsarnagawy 22/12/ Elsarnagawy, MASH
Pneumatic and hydraulic actuation system (cont.)
Fluid Mechanics LAB: Introduction to Pneumatic Circuits
Pneumatic system. It is important to know that we are working with compressed air and not with a fluid like at hydraulic systems. Pneumatics is when compressed.
Sample 2 inlet Buffer inlet Pneumatic micropump The vitamin C filtration Micro-valve outlet Sample 1 inlet MIP morphine sensing electrode Pt Ag Multiple.
Minibioreactors -> Volumes below 100 ml Characterized by: -> area of application -> mass transfer -> mixing characteristics.
Microfluidic formation of lipid bilayer array for membrane transport analysis Sadao Ota, Wei-Heong Tan, Hiroaki Suzuki, and Shoji Takeuchi Center for International.
Micro Channel Heat Sink
1 Advisor : Cheng-Hsin Chuang Advisee :Wan-Ting Su Department of Mechanical Engineering & Institute of Nanotechnology, Southern Taiwan University, Tainan,
Generation of DNA Nanostructures for Biomedical Applications by Microfluidic Manipulation of DNA Jingjiao Guan 1, Chee Guan Koh 1, Zhengzheng Fei 1, Yihua.
Modeling and Design Diaphragm Micropump
BioMEMS Device Integration, Packaging and Control for BioMEMS
Fully-integrated microfluidic chips capable of performing DNA amplification from RNA virus, sample transportation, capillary electrophoresis separation,
Multilayer Microfluidics ENMA490 Fall 2003 Brought to you by: S. Beatty, C. Brooks, S. Dean, M. Hanna, D. Janiak, C. Kung, J. Ni, B. Sadowski, A. Samuel,
MICROCHANNEL DESIGN ISSUES Susan Beatty Anne Samuel Kunal Thaker.
Integrated Microfluidic Systems for Automatic Glucose Sensing and Insulin Injection 1 Chao-June Huang, 2 Chih-Hao Wang, 3 Yi-Hsin Chen, 3 Tse-Chuan Chou.
MEMS design and Micro-fabrication Lab MML Glass PDMS #2 Choppers PDMS #1 Inlet hole Outlet hole Air inlet A NEW MICROFLUIDIC CHIP FOR FORMATION OF MICRO-DROPLETS.
Engineering Concepts Chapter 5 Terms. ACTUATOR A device that transfers fluid or electrical energy into mechanical energy.
By John Templeton.  Definition- the science that deals with the laws governing water or other liquids in motion and their applications in engineering;
The Body’s Transport System. Cardiovascular system Heart Blood Vessels – Arteries – Veins – Capillaries Blood.
In this poster, a reconfigurable microvalve array for BioMEMS lab-on-a-chip application is proposed. The device is connected to one inlet port and multiple.
Microfluidic components 2016
Multilayer Microfluidics ENMA490 Fall 2003 Brought to you by: S. Beatty, C. Brooks, S. Dean, M. Hanna, D. Janiak, C. Kung, J. Ni, B. Sadowski, A. Samuel,
Date of download: 7/8/2016 Copyright © ASME. All rights reserved. From: Dynamic Characterization of a Valveless Micropump Considering Entrapped Gas Bubbles.
Bharath S. Kattemalalawadi interfacial Science and Surface Engineering Lab (iSSELab) Department of Mechanical Engineering, University of Alberta, Edmonton,
PNUEMATIC SYSTEMS CONTROL ENGINEERING PREPARED BY:- AADITYA A PATEL CHAUHAN JAY BIPINKUMAR DABHI YOGESH J MEHTA.
Date of download: 9/18/2016 Copyright © ASME. All rights reserved. From: Droplet Detachment Mechanism in a High-Speed Gaseous Microflow J. Fluids Eng.
H & P Formulas Engineering II – August The parts and values of concern…. D 1 = diameter of cylinder (in) D 2 = diameter of piston rod (in) P 1 =
Feng-Chin Tsai+ and Jen-Ching Huang
Engineering II – August 2016
HYDRAULIC AND PNUEMATIC ACTUATION SYSTEMS
Roer Eka Pawinanto, Jumril Yunas and Burhanuddin Yeop Majlis
Introduction to hydraulics
Learning to Work Efficiently and Accurately
Hydraulic lift with the aid of energy storage (accumulators)
Pneumatics Module 9 Time delay valve.
The Body’s Transport System
Design of an integrated liquid flow cell for correlative microscopy
Hydraulic Power basics.
Fluids, Pressure, and Circulation
Gripper that grasps autonomously.
Fig. 2 Fluidic and electrical characteristics of the wireless optofluidic system. Fluidic and electrical characteristics of the wireless optofluidic system.
Presentation transcript:

Microfluidic System for Automatic Cell Culture Chun-Wei Huang, Song-Bin Huang, Gwo-Bin Lee Department of Engineering Science, National Cheng Kung University, Tainan, Taiwan Microfluidic cell culture system Pneumatic micropump & hydrophobic microvalve The current study presents a new cell chip capable of automating cell culture process. This microfluidic cell culture system comprising micropumps, microvalves, microchannels, a cell culture area and several reservoirs is fabricated by using micro-electro-mechanical-systems (MEMS) process. A new pneumatic micropump requiring only one electromagnetic valve (EMV) is developed to transport fluids. With this approach, the control circuit and peripheral apparatus are greatly simplified. Several reservoirs are used to place sample fluids such as cell culture medium, phosphate-buffered saline (PBS) and trypsin solutions. The pneumatic micropump allows the solutions to flow only in one direction. The uni-directional feature of the micropump can prevent the whole culture process from contamination. Moreover, a new check- valve is also used to prevent the culture solutions from flowing back into the microchannels. A typical cell culture process for human lung cancer cells (A549) is successfully performed on the developed microfluidic system. Abstract Schematic illustration of the automatic cell culture system. It is composed of a cell culture area, four micropumps, four micro check-valves, microchannels, and four reservoirs. Experimental (a) Growth curve of the cultured A549 cell. The cells grew exuberantly from day 1 to day 3 with a growth rate around 3. The growth rate reduces to less than 2 from day 3 to day 5. (b) CCD images from daily observation of cell growth, from Day 0 to Day 5. (a) Schematic illustration of the micro check-valve. (b) Cross-sectional view of the actuation mechanism of the microvalve. Before the micropump is activated, the liquid is blocked by the microvalve. When the micropump is activated, the microvalve is lifted due to the hydrodynamic force generated by the micropump and the liquid can flow through the microvalve. (c) SEM images of the SU-8 template (left) and the PDMS replica (right). Cell culture MEMS design and Micro-fabrication Lab MML (a) A photograph of the pneumatic micropump integrated with the micro flow sensor, air chambers and the fluid microchannel. (b) The relation between the back pressure and the flow rate. At a zero flow rate, the micropump has a maximum back pressure of 16.5 mm-H 2 O (or 0.02 psi). ( a) Photograph of the automatic cell culture chip. (b) Two micro check- valves are activated simultaneously. (c) CCD image shows that the ink can be successfully stopped. Cell culture area Trypsin reservoir Medium reservoir Waste reservoir PBS reservoir Micropump Microvalve Microchannel Air inlet (a) Schematic illustration of the pneumatic micropump consisting of three air chambers with different volumes and a flow stopper. (b) Cross- sectional view of the actuation mechanism of the micropump. When compressed air fills the chambers, the flow stopper is pushed downward first. Then, the membranes of the micropump are pushed downward sequentially, and the fluid is pumped to the left-hand side. (c) SEM images of the SU-8 template (upper) and the PDMS replica (lower) Unit: µm 1200 Flow stopper (a) (b) (c) (a) 20 µm 150 µm (b) (c) Unit: mm (a) Back pressure (mm-H 2 O) Flow rate (μl/min) (b) (a) (b) (c) Cell population Culture time (days) (a) D1 D2 D3 D4 D5 D0 (b) 2006