CMS Week, CERN, 2002 R M Brown - RAL 1 Performance Characteristics of Production VPTs R M Brown, B W Kennedy, P R Hobson (with crucial input from D J A.

Slides:



Advertisements
Similar presentations
PPRP September 2002 UK CMS 1 CMS Endcap Electromagnetic Calorimeter and Global Calorimeter Trigger, Physics & Computing Presented by Peter Hobson, Brunel.
Advertisements

2002 LHC Days at Split, Split, October 2002 D J A Cockerill - RAL 1 The ECAL Endcap Calorimeter for CMS D J A Cockerill RAL - UK 2002 LHC Days at Split.
The Lead Tungstate Calorimeter for CMS
Vacuum Phototriodes for the CMS Electromagnetic Calorimeter Endcap
CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 1 Test results from 500 preproduction VPTs R M Brown RAL - UK CERN 19 September 2001.
STFC RAL EE at SLHC CERN 15/04/08 R M Brown - RAL 1 EE at SLHC What do we expect at SLHC? EE Layout VPT vulnerability to radiation - Faceplate darkening.
CMS-UK Oversight Committee 17/5/04 D.J.A. Cockerill - RAL 1 The CMS ECAL Endcaps Crystal ECAL Endcap Calorimeter (EE) Preshower EE EE crystals.
CMS-UK Oversight Committee 18/11/03 D.J.A. Cockerill - RAL 1 The CMS ECAL Endcaps Crystal ECAL Endcap Calorimeter (EE) Preshower EE.
Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
Study of the MPPC Performance - contents - Introduction Fundamental properties microscopic laser scan –check variation within a sensor Summary and plans.
B W Kennedy, CCLRC Rutherford Appleton Laboratory VPTs for the CMS experiment B W Kennedy CCLRC Rutherford Appleton Laboratory St Petersburg, 26 April.
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
US CMS Collaboration Meeting, May 19, PWO Crystal ECAL Ren-yuan Zhu California Institute of Technology May 19 th 2001.
PPARC forum on developments in scintillator technology R M Brown - RAL 1 Scintillating Crystals for Particle Physics Outline  Performance considerations.
Evaluation of Silicon Photomultiplier Arrays for the GlueX Barrel Calorimeter Carl Zorn Radiation Detector & Medical Imaging Group Jefferson Laboratory,
PANDA electromagnetic calorimeters Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group INSTR08 28 Feb - 05 Mar 2008.
Peter Hobson - Brunel University, UK3 July 2003 VPT 4 Tesla testing  An automated characterisation facility based at Brunel has been commissioned to handle.
PSD8 September 2008, Glasgow.P R Hobson, Brunel University 1 Avalanche Photodiodes and Vacuum Phototriodes for the Electromagnetic Calorimeter of the CMS.
ELECTROMAGNETIC CALORIMETER at CMS EVANGELOS XAXIRIS June 2005 Experimental Physics Techniques.
Rutherford Appleton Laboratory CMS ECAL Split 08/09/04 R M Brown - RAL 1 The Status of the CMS Electromagnetic Calorimeter R M Brown On behalf of the CMS.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
CMS SLHC workshop, D.J.A. Cockerill (RAL)1 CMS SLHC Workshop The CMS ECAL Detector at SLHC D Cockerill RAL
The CMS Electromagnetic Calorimeter Roger Rusack The University of Minnesota On behalf of the CMS ECAL collaboration.
CMS ECAL Elba May 2006 R M Brown - RAL 1 The Status of the CMS Electromagnetic Calorimeter R M Brown On behalf of the CMS ECAL Group.
Calibration of the CMS Electromagnetic Calorimeter with first LHC data
8 July 1999A. Peisert, N. Zamiatin1 Silicon Detectors Status Anna Peisert, Cern Nikolai Zamiatin, JINR Plan Design R&D results Specifications Status of.
CMS ECAL Laser Monitoring System Christopher S. Rogan, California Institute of Technology, on behalf of the CMS ECAL Group High-resolution, high-granularity.
The CMS Electromagnetic Calorimeter at the LHC
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
B W Kennedy, CCLRC Rutherford Appleton Laboratory Vacuum Phototriodes for the CMS Electromagnetic Calorimeter Endcaps K.W.Bell, R.M.Brown, D.J.A.Cockerill,
August 99 E.Auffray CMS/ECAL STATUS on PWO crystals from Bogoroditsk after one year of preproduction for CMS-ECAL Etiennette Auffray SCINT 99, 16 August.
LHC The Large Hadron Collider (LHC) is an accelerator with 27 km circumference. Being built on the France- Switzerland border west of Geneva. It will start.
CMS ECAL End Cap WACH4, 28 Nov 2002 D Cockerill - RAL (1) - Yield, e/MeV with production crystals and production VPTs - Pre-calibration precision using.
RESMDD02 July , Florence, A.Singovski, University of Minnesota1 Radiation hardness of the Avalanche Photodiodes for ECAL CMS detector at CERN.
1 P.Rebecchi (CERN) “Monitoring of radiation damage of PbWO 4 crystals under strong Cs 137  irradiation in GIF-ECAL” “Advanced Technology and Particle.
LHC Beam Loss Monitors, B.Dehning 1/15 LHC Beam loss Monitors Loss monitor specifications Radiation tolerant Electronics Ionisation chamber development.
CMS-UK Oversight Committee 18/11/03 R M Brown - RAL 1 Exploded view of CMS ECAL Tracker HCAL 4T solenoid Muon chambers Total weight: 12,500 t Overall diameter:
Peter Hobson - Brunel University, UK3 July 2003 VPT faceplate testing  Samples of faceplate glass are irradiated to approximately 20 kGy gamma ray dose.
TIMING COUNTER: status report Giorgio CECCHET, PSI July 11th, 2003.
Update on radiation estimates for the CLIC Main and Drive beams Sophie Mallows, Thomas Otto CLIC OMPWG.
The CMS electromagnetic calorimeter
Apatity, Bogoroditsk and Shankhai PWO Crystals under Gamma Irradiation (PRELIMINARY RESULTS) Apatity IHEP Khurchatov North Crystals CMS + BTeV Alice Presented.
PMT Tests for HF Upgrade Ugur Akgun. HF PMT Proposed Tests On Every PMT: – Rise Time – Negative Pulse Width – Transit Time – Transit Time spread – Single.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
December, 2002CMS Ecal1 MGPA status Design progress since October: main efforts on process spread simulations -> look for robustness to manufacturing tolerances.
ECAL Plenary 27/2/07 D.J.A. Cockerill - RAL 1 Status of the CMS ECAL Endcaps ECAL Plenary, 27 Feb 2007 D Cockerill  VPTs  Electronics and Integration.
PbWO 4 crystals Calorimeter Liping Gan University of North Carolina Wilmington.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan for the GLD Calorimeter.
CMS ELECTROMAGNETIC CALORIMETER Jean-Pierre Ernenwein OVERVIEW 6th international conference on advanced technology and particle physics Villa Olmo, Como,
ECAL performance evolution plots Contact: 1.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Peter Križan, Ljubljana September 17, 2008 SuperB PID Peter Križan University of Ljubljana and J. Stefan Institute Forward PID: - SiPM as photon detectors.
3/06/06 CALOR 06Alexandre Zabi - Imperial College1 CMS ECAL Performance: Test Beam Results Alexandre Zabi on behalf of the CMS ECAL Group CMS ECAL.
HEP2001, Budapest, July 2001 R M Brown - RAL 1 The Vacuum Phototriodes for the CMS Electromagnetic Calorimeter P R Hobson, D C Imrie, O Sharif Brunel University,
A possible BGO Setup for the 2008 Beam Test Campaign
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
Vacuum photodetectors: present and future
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
Status of VPT Delivery and Testing
HEP2001, Budapest, July R M Brown - RAL
Overview Detector details Crystals Photo-detectors
The Status of the CMS Electromagnetic Calorimeter
Studies of the effect of the LHC cycle on
Instrumentation for Colliding Beam Physics 2017
Studies of the effect of the LHC cycle on
CMS ECAL Endcaps: Fluence/Dose (500 fb-1)
SoLID EC photonsensor.
ELECTROMAGNETIC CALORIMETER
LC Calorimeter Testbeam Requirements
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

CMS Week, CERN, 2002 R M Brown - RAL 1 Performance Characteristics of Production VPTs R M Brown, B W Kennedy, P R Hobson (with crucial input from D J A Cockerill, M Raymond, C Seez) (and thanks to M Sproston, A L Lintern, J H Williams and K W Bell for the RAL Measurements) 4 December 2002

CMS Week, CERN, 2002 R M Brown - RAL 2 Outline of Talk  Delivery status  Test Status  Specification  Test set-up  Test Results  Radiation levels  Face plate irradiation  VPT Performance  Anomalous behaviour  Conclusions

CMS Week, CERN, 2002 R M Brown - RAL 3 Photodetectors: end caps B-field orientation favourable for VPTs (Axes: 8.5 o < |  | < 25.5 o wrt to field) More radiation hard than Si diodes (with UV glass window) Gain at B = 4 T Active area of ~ 280 mm 2 /crystal Q.E. ~ 20% at 420 nm  = 26.5 mm MESH ANODE Vacuum Phototriode (VPT): Single stage photomultiplier tube with fine metal grid anode (10  m pitch)

CMS Week, CERN, 2002 R M Brown - RAL 4 VPT Gain vs Dynode Voltage

CMS Week, CERN, 2002 R M Brown - RAL 5 Technical specification Response in a magnetic field: There shall be a complete absence of internal discharge at normal operating voltage, in zero field, and for magnetic fields between 1 and 4T, at angles in the range 0 o to 26 o to the VPT axis.

CMS Week, CERN, 2002 R M Brown - RAL 6 Delivery Status 21%

CMS Week, CERN, 2002 R M Brown - RAL 7 Characterisation of VPTs 4.0T Solenoid at Brunel1.8T Dipole Magnet at RAL Detail of RAL test Cell Perspex diffuser plate with LEDs at corners. (Red circle indicates effective VPT diameter) All VPTs are measured at 0  B  1.8T and -30 o    30 o at RAL Sample VPTs are measured at B =4.0T and  = 15 o at Brunel

CMS Week, CERN, 2002 R M Brown - RAL 8 Acceptance testing status Ordered = Delivered = 3200 Visual inspection = 3200 Tested up to 1.8T = 2700 Tested at 4T = 265 Faceplate irradiations17 batches (36 faceplates)

CMS Week, CERN, 2002 R M Brown - RAL 9 Delivery and testing vs time

CMS Week, CERN, 2002 R M Brown - RAL 10 Determining the grid orientation The result of the ‘  ’ scan depends on the ‘  ’ orientation of the grid. (Not fixed in prod n )   is determined during visual inspection. (Laser interference pattern)

CMS Week, CERN, 2002 R M Brown - RAL 11 Anode response vs angle (1.8T) Arrows indicate angular range covered by EE

CMS Week, CERN, 2002 R M Brown - RAL 12 Anode response vs magnetic field  B =15 o

CMS Week, CERN, 2002 R M Brown - RAL 13 Anode sensitivity 86% have 18< A< 40 e/MeV A

CMS Week, CERN, 2002 R M Brown - RAL 14 Normalisation of RAL Test Set-up Difference % % % % % Estimated yield (e/MeV) For 5 prototype RIE tubes ‘Absolute yield’ estimated from 1999 test beam run in H4 using prototype VPTs from ET, Hamamatsu and RIE.

CMS Week, CERN, 2002 R M Brown - RAL 15 RAL/RIE Correlation Anode sensitivity (RAL) (pulsed, B=1.8T) versus Photocathode-efficiency x Gain (RIE) (dc, B=0T)

CMS Week, CERN, 2002 R M Brown - RAL 16 Relative gain at 4T

CMS Week, CERN, 2002 R M Brown - RAL 17 Doses and neutron fluences Integrated dose (kGy) and neutron fluence (x10 13 cm -2 ) for  L = 5x10 5 pb -1 (~10 yrs) Black: Dose in the Crystals at the position of the shower maximum Blue: Dose behind the crystals at the position of the photodetectors Red: Neutron fluences behind the crystals HCAL Barrel ECAL Barrel ECAL Endcap

CMS Week, CERN, 2002 R M Brown - RAL 18 Faceplate irradiation 91.4% transmission of PbWO 4 spectrum after 20.8 kGy Radiation Hardness: Sample faceplates shall, neglecting surface reflection losses, transmit at least 90% of PbWO 4 light, following a dose of 20 kGy and exposure to a fluence of 5x10 14 fast neutrons cm -2.

CMS Week, CERN, 2002 R M Brown - RAL 19 CMS ECAL Layout 3170 mm 1290 mm Full projective geometry (‘Off-pointing’ by ~3 o ) Barrel: 17x2 Crystal types End cap: 1 Crystal type 14648

CMS Week, CERN, 2002 R M Brown - RAL 20 Transverse Noise Analysis by Chris Seez et al: ‘Transverse noise’ E T noise = E noise x sin  Allows for light loss in PWO (dose vs  ),etc Exploits variation in VPT response to achieve uniform E T noise after ‘sorting’ But assumes Response A  34 e/MeV (28 e/MeV more realistic) Coverage 27% 29% 19% 12% 11% 2%

CMS Week, CERN, 2002 R M Brown - RAL 21 Possible noise improvements for endcap if reduce dynamic range requirement to 1500 GeV Cpf -> Cpf/2, Rpf -> 2.Rpf charge amp. gain doubled and subsequent noise sources less significant GainRGRG Diff. stage gain Energy range [GeV] Noise [electrons] Energy range [GeV] Noise [electrons] – – – – – – TeV fullscale1.5 TeV fullscale Noise simulation of ‘MGPA’ (From talk by Mark Raymond)

CMS Week, CERN, 2002 R M Brown - RAL 22 Anomalous behaviour at 1.8T

CMS Week, CERN, 2002 R M Brown - RAL 23 Response vs time

CMS Week, CERN, 2002 R M Brown - RAL 24 Anomalous behaviour at 4T

CMS Week, CERN, 2002 R M Brown - RAL 25 Summary  VPT Production is well underway (>20% delivered on schedule)  RAL capacity for testing at 1.8T is adequate and allows for some re-testing if required  Batch VPT testing at 4T and faceplate irradiation checks progressing smoothly at Brunel  The measured performance of the VPTs matches the EE design objectives, but ‘sorting’ will be required to accommodate the spread in anode response  Anomalous behaviour has been observed in some tubes at certain angles in a high magnetic field. This is under investigation by RIE