1 Dynamic Behavior Chapter 5 In analyzing process dynamic and process control systems, it is important to know how the process responds to changes in the.

Slides:



Advertisements
Similar presentations
Dynamic Behavior of Ideal Systems
Advertisements

CHE 185 – PROCESS CONTROL AND DYNAMICS
Dynamic Behavior of Closed-Loop Control Systems
Lecture 3: Common Simple Dynamic Systems
Chapter 4 Continuous Time Signals Time Response Continuous Time Signals Time Response.
CHAPTER V CONTROL SYSTEMS
Lect.7 Steady State Error Basil Hamed
Dynamic Behavior Chapter 5 In analyzing process dynamic and process control systems, it is important to know how the process responds to changes in the.
Dynamic Behavior Chapter 5
4.3. Time Response Specification in Design
Laplace Transforms Important analytical method for solving linear ordinary differential equations. - Application to nonlinear ODEs? Must linearize first.
Transfer Functions Convenient representation of a linear, dynamic model. A transfer function (TF) relates one input and one output: The following terminology.
Chapter Summer 2. Comparator 3. Block Blocks in Series
Dynamic Behavior and Stability of Closed-Loop Control Systems
Development of Empirical Models From Process Data
Transfer Functions Convenient representation of a linear, dynamic model. A transfer function (TF) relates one input and one output: The following terminology.
Transient & Steady State Response Analysis
Dynamic Behavior and Stability of Closed-Loop Control Systems
Chapter 11 1 Closed-Loop Responses of Simple Control Systems In this section we consider the dynamic behavior of several elementary control problems for.
Review last lectures.
Chapter 3 1 Laplace Transforms 1. Standard notation in dynamics and control (shorthand notation) 2. Converts mathematics to algebraic operations 3. Advantageous.
More General Transfer Function Models
Chapter 5 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Chapter 7 PID Control.
Out response, Poles, and Zeros
Feedback Control Systems (FCS) Dr. Imtiaz Hussain URL :
In Engineering --- Designing a Pneumatic Pump Introduction System characterization Model development –Models 1, 2, 3, 4, 5 & 6 Model analysis –Time domain.
ERT 210/4 Process Control & Dynamics
Transfer Functions Chapter 4
DYNAMIC BEHAVIOR AND STABILITY OF CLOSED-LOOP CONTROL SYSTEMS
Chapter 13 1 Frequency Response Analysis Sinusoidal Forcing of a First-Order Process For a first-order transfer function with gain K and time constant,
Chapter 3 mathematical Modeling of Dynamic Systems
Recap of Session VII Chapter II: Mathematical Modeling Mathematical Modeling of Mechanical systems Mathematical Modeling of Electrical systems Models of.
Prepared by Mrs. Azduwin Binti Khasri
DYNAMIC BEHAVIOR OF PROCESSES :
Chapter 5 Transient and Steady State Response “I will study and get ready and someday my chance will come” Abraham Lincoln.
1 Chapter 5 Sinusoidal Input. 2 Chapter 5 Examples: 1.24 hour variations in cooling water temperature Hz electrical noise (in USA!) Processes are.
DYNAMIC BEHAVIOR OF PROCESSES :
Chapter 3 Dynamic Response The Block Diagram Block diagram is a graphical tool to visualize the model of a system and evaluate the mathematical relationships.
Transfer Functions Convenient representation of a linear, dynamic model. A transfer function (TF) relates one input and one output: The following terminology.
Lec 6. Second Order Systems
CHAPTER VI BLOCK DIAGRAMS AND LINEARIZATION
1 Teaching Innovation - Entrepreneurial - Global The Centre for Technology enabled Teaching & Learning, M G I, India DTEL DTEL (Department for Technology.
ERT 210/4 Process Control & Dynamics DYNAMIC BEHAVIOR OF PROCESSES :
TRANSFER FUNCTION Prepared by Mrs. AZDUWIN KHASRI.
Anis Atikah Ahmad CHAPTER 11: Dynamic Behaviour & Stability of Closed-Loop Control Systems Anis Atikah Ahmad
Chapter 11 1 ERT 210/4 Process Control CHAPTER 11 DYNAMIC BEHAVIOR AND STABILITY OF CLOSED-LOOP CONTROL SYSTEMS.
DYNAMIC BEHAVIOR OF PROCESSES :
Control engineering ( ) Time response of first order system PREPARED BY: Patel Ravindra.
System Dynamics Dr. Mohammad Kilani
ETEC 4501 Chapter 4 Laplace Transforms and Transfer Functions.
Lecture 7/8 Analysis in the time domain (II) North China Electric Power University Sun Hairong.
Transfer Functions Convenient representation of a linear, dynamic model. A transfer function (TF) relates one input and one output: The following terminology.
Automatic Control Theory CSE 322
Dynamic Behavior Chapter 5
Laplace Transforms Chapter 3 Standard notation in dynamics and control
Control Response Patterns
Transfer Functions Chapter 4
Time Domain and Frequency Domain Analysis
CHAPTER VI BLOCK DIAGRAMS AND LINEARIZATION
Dynamic Behavior Chapter 5
Dynamic Behavior Chapter 5
Control Response Patterns
First-Order System Chapter 5
Proportional Control and Disturbance Changes
Second-Order Systems Chapter 5 Standard form:
Laplace Transforms Important analytical method for solving linear ordinary differential equations. - Application to nonlinear ODEs? Must linearize first.
Laplace Transforms Important analytical method for solving linear ordinary differential equations. - Application to nonlinear ODEs? Must linearize first.
Dynamic Behavior Chapter 5
Time Response, Stability, and
Presentation transcript:

1 Dynamic Behavior Chapter 5 In analyzing process dynamic and process control systems, it is important to know how the process responds to changes in the process inputs. A number of standard types of input changes are widely used for two reasons: 1.They are representative of the types of changes that occur in plants. 2.They are easy to analyze mathematically.

2 1.Step Input A sudden change in a process variable can be approximated by a step change of magnitude, M: Chapter 5 Special Case: If M = 1, we have a “unit step change”. We give it the symbol, S(t). Example of a step change: A reactor feedstock is suddenly switched from one supply to another, causing sudden changes in feed concentration, flow, etc. The step change occurs at an arbitrary time denoted as t = 0.

3 Chapter 5 Example: The heat input to the stirred-tank heating system in Chapter 2 is suddenly changed from 8000 to 10,000 kcal/hr by changing the electrical signal to the heater. Thus, and 2.Ramp Input Industrial processes often experience “drifting disturbances”, that is, relatively slow changes up or down for some period of time. The rate of change is approximately constant.

4 Chapter 5 We can approximate a drifting disturbance by a ramp input: Examples of ramp changes: 1.Ramp a setpoint to a new value. (Why not make a step change?) 2.Feed composition, heat exchanger fouling, catalyst activity, ambient temperature. 3.Rectangular Pulse It represents a brief, sudden change in a process variable:

5 Chapter 5 Examples: 1.Reactor feed is shut off for one hour. 2.The fuel gas supply to a furnace is briefly interrupted. 0 h X RP T w Time, t

6 Chapter 5

7 Examples: 1.24 hour variations in cooling water temperature Hz electrical noise (in the USA) 4.Sinusoidal Input Processes are also subject to periodic, or cyclic, disturbances. They can be approximated by a sinusoidal disturbance: where: A = amplitude,  = angular frequency

8 Chapter 5 Examples: 1.Electrical noise spike in a thermo-couple reading. 2.Injection of a tracer dye. 5.Impulse Input Here, It represents a short, transient disturbance. Useful for analysis since the response to an impulse input is the inverse of the TF. Thus, Here,

9 Chapter 5 The corresponding time domain express is: where: Suppose. Then it can be shown that: Consequently, g(t) is called the “impulse response function”.

10 Chapter 5 The standard form for a first-order TF is: where: Consider the response of this system to a step of magnitude, M: Substitute into (5-16) and rearrange, First-Order System

11 Chapter 5 Take L -1 (cf. Table 3.1), Let steady-state value of y(t). From (5-18), t___ Note: Large means a slow response.

12 Chapter 5 Consider a step change of magnitude M. Then U(s) = M/s and, Integrating Process Not all processes have a steady-state gain. For example, an “integrating process” or “integrator” has the transfer function: Thus, y(t) is unbounded and a new steady-state value does not exist. L -1

13 Chapter 5 Consider a liquid storage tank with a pump on the exit line: Common Physical Example: -Assume: 1.Constant cross-sectional area, A. 2. -Mass balance: -Eq. (1) – Eq. (2), take L, assume steady state initially, -For (constant q),

14 Chapter 5 Standard form: Second-Order Systems which has three model parameters: Equivalent form:

15 Chapter 5 The type of behavior that occurs depends on the numerical value of damping coefficient, : It is convenient to consider three types of behavior: Damping Coefficient Type of ResponseRoots of Charact. Polynomial OverdampedReal and ≠ Critically dampedReal and = UnderdampedComplex conjugates Note: The characteristic polynomial is the denominator of the transfer function: What about ? It results in an unstable system

16 Chapter 5

17 Chapter 5

18 Chapter 5 1.Responses exhibiting oscillation and overshoot (y/KM > 1) are obtained only for values of less than one. 2.Large values of yield a sluggish (slow) response. 3.The fastest response without overshoot is obtained for the critically damped case Several general remarks can be made concerning the responses show in Figs. 5.8 and 5.9:

19 Chapter 5

20 Chapter 5 1.Rise Time: is the time the process output takes to first reach the new steady-state value. 2.Time to First Peak: is the time required for the output to reach its first maximum value. 3.Settling Time: is defined as the time required for the process output to reach and remain inside a band whose width is equal to ±5% of the total change in y. The term 95% response time sometimes is used to refer to this case. Also, values of ±1% sometimes are used. 4.Overshoot: OS = a/b (% overshoot is 100a/b). 5.Decay Ratio: DR = c/a (where c is the height of the second peak). 6.Period of Oscillation: P is the time between two successive peaks or two successive valleys of the response.