Comparison of Load to Failure and Calcar Strain for Two Press-Fit Femoral Stem Implantation Techniques in Matched Cadaver Femora During Simulated Impaction.

Slides:



Advertisements
Similar presentations
Introducció Two surgical techniques to determine FCER Landmarks
Advertisements

Hip Arthroplasty.
Re-written by: Daniel Habashi Intertrochanteric Hip Fractures.
Testing Test Setup TapLok Insert Shear Key Copper Threads Friction Tests Collar Shear Tests NSTX TF FLAG JOINT REVIEW 8/7/03 Michael Kalish.
Modulus of Elasticity and Poisson Ratio of Concrete
by Spencer Amundsen, Karl Koenig, Douglas Goodwin, and Vincent Memoli
Forging new generations of engineers. The following MATERIAL PROPERTIES can be evaluated / determined by TENSILE TESTING: STRENGTH DUCTILITY ELASTICITY.
Chapter 11 Mechanical Properties of Materials
Department of Bioengineering FRACTURE PROPERTIES OF CHICKEN BONES WITH AND WITHOUT MARROW 101A1 Edwin Akrong – Background & Hypothesis Ping-Chien (Sam)
1 ASTM : American Society of Testing and Materials.
Congenital Hip Dislocation.
Hypothesis Figure 1: Proximal end of human humerus bone fitted with the 3.5mm Proximal Humerus Plate before testing. Figure 2: Proximal end of human humerus.
 Finite Element modeling to predict the implant holding strength of osteoporotic bone Bhishan Kayastha ( ) Supervisor: Karen Reynolds.
Figure 1: Locations of rosette strain gauges (n = 10) on the cadaveric pelvis. * * * * * * * * * * G Figure 3: Fixture for loading the pelvis (A) actuator,
Computer Assisted Knee Replacement Surgery By (insert surgeon name)
Knee replacement surgery Typical patient has severe knee osteoarthritis.
Impulse Loading on the Lower Leg using a Synthetic Bone Marley Winfield Department of Biochemical Engineering and Medical Biophysics MBP 3302.
Mechanics of Materials Goal:Load Deformation Factors that affect deformation of a structure P PPP Stress: intensity of internal force.
Statistical Analysis. Purpose of Statistical Analysis Determines whether the results found in an experiment are meaningful. Answers the question: –Does.
Context The Femur Basic Model Comparison Objectives Results Application Structural Analysis of the Femur: A Collaborative Tool for Surgeons and Engineers.
© 2011 Autodesk Freely licensed for use by educational institutions. Reuse and changes require a note indicating that content has been modified from the.
Statistical Analysis Statistical Analysis
Mechanical Properties
Review for Exam #1 ISE316 Fall Readings Chapter 1 -- What is manufacturing? Chapter 2 -- The nature of materials Chapter 3 -- Mechanics of materials.
Computer-Assisted Knee Replacement Surgery. Knee Replacement Surgery Arthritic surfaces on the tibia and femur are removed. Arthritic surfaces on the.
ICJR Cleveland Clinic: How I do the Direct Anterior Approach with a table Stefan Kreuzer, MD Houston, Texas Memorial Bone and Joint Clinic.
Controversies and Techniques in the Surgical Management of Patellofemoral Arthritis by William M. Mihalko, Yaw Boachie-Adjei, Jeffrey T. Spang, John P.
Transformations of Stress and Strain
Volume 91(Supplement 6): Sex Differences in Hip Morphology: Is Stem Modularity Effective for Total Hip Replacement? by Francesco Traina, Manuela.
by Donald G. Eckhoff, Thomas F. Dwyer, Joel M. Bach, Victor M
Tensile testing of an as-cast copper alloy
Mechanical Properties Considerations for Fast Core Propellants
Enhanced Early Outcomes with the Anterior Supine Intermuscular Approach in Primary Total Hip Arthroplasty by Keith R. Berend, Adolph V. Lombardi, Brian.
Mechanical Properties of Materials
Open Reduction and Internal Fixation Compared with Circular Fixator Application for Bicondylar Tibial Plateau Fractures by Jeremy A. Hall, Murray J. Beuerlein,
Volume 91(Supplement 2 Part 1):50-73
Femoral Component Revision with Use of Impaction Bone- Grafting and a Cemented Polished Stem by B. Willem Schreurs, J.J. Chris Arts, Nico Verdonschot,
Mechanics of Elastic Materials. Why study mechanics? Useful for the analysis and design of load-bearing structures, such as: buildings bridges space shuttles.
Percutaneously Assisted Total Hip Arthroplasty (PATH): A Preliminary Report by Brad L. Penenberg, W. Seth Bolling, and Michelle Riley J Bone Joint Surg.
Rigid Intramedullary Nailing of Femoral Shaft Fractures in Skeletally Immature Patients Using a Lateral Trochanteric Entry Portal by Elliott J. Kim, Samuel.
A 2D/3D correspondence building method for reconstruction of a 3D bone surface model Longwei Fang
Date of download: 6/23/2016 Copyright © ASME. All rights reserved. From: Development of an Inertia-Driven Model of Sideways Fall for Detailed Study of.
Distal Third Femoral Shaft Fracture: Antegrade vs. Retrograde Nailing Michael Zlowodzki MD University of Minnesota Department of Orthopaedic Surgery.
 Dual energy x-ray absorptiometry (DXA) is the current standard for measuring bone mineral density (BMD) as it offers quick scan times with low radiation.
ISE 311 Tensile Testing Lab in conjunction with Section 3.1 in the text book “Fundamentals of Modern Manufacturing” Third Edition Mikell P. Groover 4/25/2008.
Olson EM, Sturm PF, Jain VV, Schultz LR, Glos DL, Bylski-Austrow DI
Chapter 4. Mechanical Testing: Tension Test and Other Basic Tests
Dislocation Rates in Furlong Hemiarthroplasty General Characteristics
Patterns of Failure in the Distal Radius Following Treatment for AO 23-A3.2 Fractures Using Two-Column Volar Plates Deana Mercer, MD; Christina Salas,
Introduction We select materials for many components and applications by matching the properties of the material to the service condition required of the.
Date of download: 12/22/2017 Copyright © ASME. All rights reserved.
Comparison of carina- versus bony anatomy-based registration for setup verification in esophageal cancer image-guided radiotherapy Melanie Machiels* 1,
Tensile Testing of Aluminum Alloy
Poisons Ratio Poisons ratio = . w0 w Usually poisons ratio ranges from
Volume 4, Issue 3, Pages (September 2018)
Forging new generations of engineers
Eng. Ahmed Al-Afeefy Eng. Ibrahim Aljaish
Tutorial in Mechanical Properties
Determination of Fracture Toughness
Nahhas, M., Turcotte, R.E. and Isler, M.
Volume 4, Issue 1, Pages (March 2018)
Lecture 9 – Deformation and Damage
A clinically realistic large animal model of intra-articular fracture that progresses to post- traumatic osteoarthritis  J.E. Goetz, D. Fredericks, E.
Anatomic Arthroscopic Ligamentum Teres Reconstruction for Hip Instability  Travis J. Menge, M.D., Justin J. Mitchell, M.D., Karen K. Briggs, M.P.H., Marc.
Volume 88, Issue 3, Pages (November 2015)
Emergency Clinical Hospital of Constanta, Romania
A comparison of radiographic leg-length and offset discrepancies between 2 intraoperative measurement techniques in anterior total hip arthroplasty  Daniel.
PDT 153 Materials Structure And Properties
Mechanical Properties Of Metals - I
Femoral Geometry and Bone Quality Influence on Fracture Patterns of the Proximal Femur Andris Džeriņš1,3, Valts Boginskis3, Pēteris Studers1,2, Matīss.
Presentation transcript:

Comparison of Load to Failure and Calcar Strain for Two Press-Fit Femoral Stem Implantation Techniques in Matched Cadaver Femora During Simulated Impaction William Kurtz 1, Stephen Murphy 2, Irina Timmerman 3, Satya Nambu 3, James Brownhill 3, Michael Roark 3, Jon Moseley 3 1) Tennessee Orthopedic Alliance, Nashville, TN 2) Center for Computer Assisted and Reconstructive Surgery – New England Baptist Hospital, Boston, MA 3) Wright Medical Technology, Inc, Arlington, TN TOATOA INTRODUCTION A tight press-fit condition, coupled with the wedge-like geometry of a hip stem (Figure 1), puts substantial hoop stresses into the proximal femur when the stem is impacted into prepared bone. Depending on the degree of press-fit and the size and quality of the patient’s bone, this can lead to intra-operative fracture of the femur. A recently developed technique for less invasive implantation utilizes a modified approach to prepare the femoral canal in-situ in which the femoral head is not removed until after the stem has been implanted. DISCUSSION The force required to fracture the femur was higher for the SUPERCAP® group, which suggests that removal of the femoral head increases the chance of an intraoperative fracture. In general, the peak principle strain correlated with the peak force measurements (r = 0.573), but the differences in strain between experimental and control groups were not statistically significant (p>0.05). All constructs fractured with vertical splits initiating from the proximal end of the stem. With the traditional technique, fractures occurred more often on the medial or antero- medial area, with the split initiating at the resection line. The fractures in the SUPERCAP® group were more variable in location, with only one fracture initiating antero-medially and none on the medial side. MATERIALS AND METHODS (continued) Twenty four hours prior to testing, specimens were thawed and cut off six inches below the distal tip of the stem and potted vertically inside a 3” diameter aluminum cylinder 3” high using dental acrylic. Two hours prior to testing, two rosette strain gauges (Omega, gage L = 1 mm) were adhered to the calcar region. (Figure 2) For femurs prepared with the traditional technique one gage was placed below on the medial calcar, 5mm below the resection line and the other was placed at the same level and 10mm anterior to the first gage.(1) Distances from the gages to the lesser trochanter were measured on the traditionally prepared femur and used to place the gages on the SUPERCAP® femur. (Figure 3) The construct was secured in a servohydraulic load frame (Mini-Bionix, MTS Inc.) using machine clamps. A custom ram was used to apply load to the proximal surface of the hip stem at a rate of 25 mm/sec. The ram was offset 5mm proximally from the superior flat of the stem to simulate impact loading. Load, displacement, and strain data were captured at a rate of 200 Hz. The maximum load to failure, principle strains for the medial and antero-medial gage locations, and failure mode were determined for each femur. Maximum bone stress was calculated from the peak von-Mises strain using a value of 17.5 GPa for the elastic modulus of cortical bone. RESULTS In general the peak load to failure was greater for the larger size stems. (Figure 4) Seven of the pairs had higher peak loads for the SUPERCAP® femur (delta range: 116 – 3961N), three had higher peak loads for the control technique (delta range: 45 – 470N) CONCLUSIONS The use of a less invasive, in-situ technique for implantation of the femoral stem resulted in a clinically and statistically significant increase in the force required to fracture the femur. This implies that the in-situ technique should reduce the chances of intraoperative fractures due to stem impaction. REFERENCES 1.Elias JJ et al, “Medial cortex strain distribution during noncemented total hip arthroplasty” Clin Orthop Rel Res 2000 (370): PURPOSE To compare the load to failure and calcar stress and strain between traditional femoral preparation and implantation and the less invasive technique using matched pairs of cadaver femora. MATERIALS AND METHODS Ten matched-pair cadaveric femurs were imaged to screen for signs of severe osteoarthritis, deformity, tumors or existing proximal hardware. Specimen pairs were randomly assigned to either the traditional or less-invasive SUPERCAP® technique. Femurs were clamped into a custom frame, reamed and progressively broached following the surgical protocols for both techniques. The femoral head was resected for the traditional technique prior to femur preparation, but was left in place for the less- invasive technique. Fluoroscopy was used to verify final broach size and alignment prior to impaction of the modular, plasma-sprayed stem (PROFEMUR® Z, Wright Medical Technology, Arlington, TN). The same size stem was used for both sides of each matched pair. Following implantation, the specimens were wrapped, enclosed in plastic bags, and frozen. Figure 1: PROFEMUR® Z modular, plasma- sprayed stem component Figure 2: Specimen prepared using the traditional surgical technique. Strain gages on the medial and antero-medial surfaces are shown. Figure 4: (Left) A force vs displacement plot of a typical specimen pair. Sudden drops in force are indicative of bone fracture. (Right) The maximum stress recorded by the strain gages in the calcar region of the proximal femur. PropertySUPERCAP®TraditionalDelta Mean Peak Force: N 8,479 (3,793) 6,813 (3,532) 1660 (1620) Peak Force Range: N 4,568 to 16,988 1,940 to 13, to 3,961 Mean Peak Strain: 3,451 (2,790) 2,451 (1,895) 748 (2,212) RESULTS (continued) Table 1: Average Peak Loads and Strain The maximum load and corresponding principle stresses are summarized in Table 1. The mean difference in peak force between traditional and SUPERCAP® groups was 1,660N (p = 0.01, two sided t-test, and p = 0.027, Wilcoxon signed rank test). Figure 3: Specimen prepared using the SUPERCAP® surgical technique.