Realistic requirements from R 3 B program  In-beam tests of Demonstrators (no TRD yet) Decisions on: Readout device, Forward cap detectors (  Detector.

Slides:



Advertisements
Similar presentations
Edge Sensors for the Schwarzschild-Couder Telescopes David Hanna McGill University UCLA AGIS Meeting June 26-27, 2008.
Advertisements

Basic Principles of X-ray Source Detection Or Who Stole All Our Photons?.....
Recent progress with TES microcalorimeters and signal multiplexing J. Ullom NIST NASA GSFC SRON J. Beall R. Doriese W. Duncan L. Ferreira G. Hilton R.
Adding electronic noise and pedestals to the CALICE simulation LCWS 19 – 23 rd April Catherine Fry (working with D Bowerman) Imperial College London.
Status of Ultra-low Energy HPGe Detector for low-mass WIMP search Li Xin (Tsinghua University) KIMS collaboration Oct.22nd, 2005.
From Cave C to R3B: Time Schedule 2008 Experiments with upgraded setup: proton arm, Si detectors, QFS detection system 2009 Implementation of new readout.
Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden.
Proton test facilities Uppsala, TSL, GWC, B-line (Blue hall): Energy ±0.80 MeV. Flux reduced from normal 2·10 8 s -1 to 900 s -1 with a profile as.
Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden.
Tests of scintillators CsI, CsI(Na), BGO, NaI(Tl) CsI(Tl)
R&D on CsI(Tl) + APD Optimisation of the energy resolution M. Gascón I.Durán.
Crystals !? R3B/EXL meeting Milan Oct-06. Crystal growing factories Quality and price on 20(23)*20(23)*110 mm 3 detector light output uniformity* price.
Progress report on APD zThe Gain dependence on temperature measurements were made using a good channel of APD for three temperature values, using LED as.
GEANT4 simulations for the Lund R 3 B prototype Douglas Di Julio Lund University, Lund, Sweden.
Especially concerning optimization of identification power, energy resolution, efficiency, optimal readout device for the barrel part of CALIFA, a calorimeter.
Status of the Calorimeter Working group activities GSI, 16 th October 2007.
What the Lund/Dubna group wishes to achieve until next annual meeting produce two* close-to-final (forward) EGPA clusters requiresCsI(Tl) decided (alternatives?,doping.
B. Jakobsson, CWG meeting, June 18-19, 2007: Intoductory slide
ipno.in2p3.fr Orsay - October 2007IPNO-RDD-Jean Peyré1 Test Protocole for Crystals with Gamma Sources Jean Peyré Oct 2007.
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
2/26/2008 To : Teknisk-Naturvetenskapliga fakulteten Uppsala universitet Dekanus, Prof. Jan-Otto Carlsson Box 256 SE UPPSALA From: FAIR/NuSTAR R.
Ideas on VFEE I. Durán Universidad de Santiago de Compostela NUSTAR Calorimeter WG Valencia, June 2005.
October-November 2003China - ALICE meeting1 PHOS in ALICE A PHOton Spectrometer with unique capabilities for the detection/identification of photons and.
A High-speed Adaptively-biased Current- to-current Front-end for SSPM Arrays Bob Zheng, Jean-Pierre Walder, Henrik von der Lippe, William Moses, Martin.
H. Alvarez Pol - NUSTAR Calorimeter WG R3B/EXL Collaboration Meeting - Santiago Sept Geometrical design, simulation progress and first detector.
RAD2012, Nis, Serbia Positron Detector for radiochemistry on chip applications R. Duane, N. Vasović, P. LeCoz, N. Pavlov 1, C. Jackson 1,
Photon detection Visible or near-visible wavelengths
Absolute light output determination of crystal scintillators
EXL/crystal simulations B. Genolini Simulation of NUSTAR crystals with Litrani Presentation of Litrani: simulation of.
INSTR-08, BINP, Novosibirsk 1 Belle calorimeter upgrade B.Shwartz, Budker Institute of Nuclear Physics Novosibirsk on behalf of BELLE calorimeter.
DSSD – Si, 300 mkm, 1.85 mm pitch, 59.5x59.5 mm**2. CsI(Tl)/PD, 20x20(front)23x23(back)x100mm**3. Produced by St.Gobain, Khar’kov and China Companies PD.
Status of scintillator KLM study P. Pakhlov (ITEP)
November 8, 2005JLAB Awake Animal Project New Instrumentation for JLAB Awake Animal Project Smaller Pixel Size requires higher granularity in PMT (2.4.
Status of Projectile Spectator Detector A.Kurepin (Institute for Nuclear Research, Moscow) I. Introduction to PSD. II. Conception and design. III. Development.
Light Output Uniformity of Long CsI(Tl) crystals - the “bottle-neck” for gamma and proton spectroscopy Light Output Uniformity for CsI(Tl) as supplied.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
Montpellier, November 15, 2003 J. Cvach, TileHCAL and APD readout1 TileHCAL- fibre readout by APD APDs and preamplifiers Energy scan with DESY beam –Energy.
Scintillator tile-SiPM system development for CALICE Engineering AHCAL Prototype Michael Danilov, ITEP & CALICE LCWS10 Beijing March 2010 Outline New scintillator.
Status of the Genova activity on a direction-sensitive optical module toward the KM3 detector M.Taiuti WP3 PYLOS 16/4/2007.
Progress on the beam tracking instrumentation Position measurement device Tests performed and their resolution Decision on electronics Summary.
PSD upgrade: concept and plans - Why the PSD upgrade is necessary? - Concept and status of the PSD temperature control - Concept of the PSD analog part.
Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.
Gain stability and the LYSO beam radiation monitor measurements
RESMDD02 July , Florence, A.Singovski, University of Minnesota1 Radiation hardness of the Avalanche Photodiodes for ECAL CMS detector at CERN.
Multipixel Geiger mode photo-sensors (MRS APD’s) Yury Kudenko ISS meeting, KEK, 25 January 2006 INR, Moscow.
first results from EMCal test beam
December Status of MRS photodiodes ND280 Convener’s Meeting, 9 June 2006 Yury Kudenko INR, Moscow.
Digitization in EMC simulation Dmytro Melnychuk, Soltan Institute for Nuclear Studies, Warsaw, Poland.
Quality control for large volume production GEM detectors Christopher Armaingaud On behalf of the collaboration GEMs for CMS.
A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA.
PSD upgrade: concept and plans - Why the PSD upgrade is necessary? - Concept of the PSD temperature stabilization and control - Upgrade of HV control system.
Avalanche Photodiodes from the Start.
Gusev K., JINR , Gerda meeting Spectrometric performance of Kurchatov Institute detectors.
R3B - meeting April GSI Readout concepts for the CALIFA detector options dynamic range preamplifier solution digital solution digital readout chain.
CBM 12 th Meeting, October 14-18, 2008, Dubna Present status of the first version of NIHAM TRD-FEE analogic CHIP Vasile Catanescu and Mihai Petrovici NIHAM.
Update on works with SiPMs at Pisa Matteo Morrocchi.
May 10-14, 2010CALOR2010, Beijing, China 1 Readout electronics of the ALICE photon spectrometer Zhongbao Yin *, Lijiao Liu, Hans Muller, Dieter Rohrich,
CALIFA - USC R&D activities: Designing and prototyping CALIFA a next generation calorimeter for R3B/FAIR Huelva July 07.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Hybrid Detector(s) for Complete Gamma Ray Spectroscopy S. S. Bhattacharjee, R Raut, S S Ghugre, A K Sinha UGC-DAE Consortium For Scientific Research, Kolkata.
26th September 2014 Guillermo Ribeiro 1 G. Ribeiro, E. Nácher, A. Perea, J. Sánchez del Río, O. Tengblad Instituto de Estructura de la Materia – CSIC,
Performance of the PHENIX NCC Prototype Michael Merkin Skobeltyn Institute of Nuclear Physics Moscow State University.
Ilhan TAPAN* and Fatma KOCAK
Status of ULE-HPGe Experiment for WIMP Search in YangYang
Activities on straw tube simulation
Roman Mizuk (ITEP, Moscow)
The Lund R3B prototype: In-beam proton tests and simulations
On behalf of the GECAM group
BESIII EMC electronics
Scintillator tile- SiPM systems R&D
Presentation transcript:

Realistic requirements from R 3 B program  In-beam tests of Demonstrators (no TRD yet) Decisions on: Readout device, Forward cap detectors (  Detector manufacturing program, Formulation of acceptance test) CALIFA LU DEMONSTRATOR ARRAY V. Avdeichikov, P. Golubev, B. Jakobsson, June 2008

Readout of CsI(Tl) – photodiodes? + PDs do not need specific temperature or voltage stability precausions What about resolution and threshold? With existing PA/PD significantly worse energy resolution high threshold ~100 keV

Can the proper combination of PA and PD solve the problem? black points: calculated, open (1.0 nA), closed (2.0 nA). red points: measured with PAs eV5091 and PHOS The gamma energy resolution depends very much on the PD noise level. A low-capacity (15 pF) PD with low current (< 1 nA) can give a resolution close to what an APD can provide.  We should order a PD with these parameters now if

the R3B and/or EXL programmes or at least a substantial part of these programmes can live with a threshold of ~100 keV. remember the proton performance  some parts of the programmes may have a stronger wish to use CALIFA/EGPA to identify light fragments (fragmentation, spallation, multifragmentation.....)

Other items that the LU group wrestles with are: - How to optimize gain corrected summing of gamma signals - How to optimize the LO uniformity in a practical way - The response function non-linearity in CsI(Tl) - Large scale production and its control (certification) mechanisms - Production of 210 mm CsI(Tl) detectors as option for La – crystals about which you can read in the submitted report (pdf file) by V. Avdeichikov and in our (two) previous video meeting reports -Writing a TSR report which may be useful for the TDR (BJ) - Preparing in-beam tests (proposals to be discussed in Tech. Boards) - Planning a test station in Kharkov (Dubna, VA – producer not chosen yet)