Presentation is loading. Please wait.

Presentation is loading. Please wait.

Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden.

Similar presentations


Presentation on theme: "Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden."— Presentation transcript:

1 Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden

2 Outline Simulation overview –Geometry –Physics list Benchmark simulations Response to gammas and protons Light collection Future work

3 Geometry Material: CsI Separation distance: 0.4 mm, vacuum 15 crystals 10x30 130 mm 15x42 10x10

4 Physics list For gamma: –Low energy package – Photoelectric and conversion, Rayleigh, Compton Scattering For e - and e + : –Low energy package for e - –Multiple scattering, ionization, Bremsstrahlung, and annihilation (for e + ) For protons –QGSP_BIC physics list –QGSP_BERT

5 Preliminary simulations Compare with previous calculations Performed by Thomas Zerguerras 20 MeV gamma Large single block: 110x110x200mm 3 5x5 array of crystals, 22x22x200mm 3 0.1 mm between crystals, space filled with kapton

6 500 keV gamma Large fraction of full energy events in center crystal ~60% of events lie in full energy peak in center crystal Some energy deposition in surrounding crystals

7 500 keV gamma Sum spectrum for entire block, ~91% of the events lie in the full energy peak On average, 1 crystal out of 15 is fired per incident gamma, 6 max width at half max ~ 1 crystal

8 15 MeV gamma Energy deposited in more crystals Number of full energy events decreases No significant full energy peak in center crystal

9 15 MeV gamma Sum spectrum for entire block, full energy peak appears, ~13% of the events lie in the full energy peak ~3 crystals out of 15 fire per incident Gamma,11 at most, width increases ~3 crystals

10 28 MeV gamma Large spread of energy deposition Very few fully contained events, no full energy peak in center crystal

11 28 MeV gamma Full energy peak can be seen, only about ~2.5% of events lie in full energy peak 4.5 crystals out of 15 fire on average, 12 at most, width ~4 crystals

12 50 MeV protons QGSP_BIC physics list Energy deposited mostly in center crystal, little to no energy spread

13 50 MeV protons QGSP_BERT physics list

14 180 MeV protons Large full energy peak in central crystal Some energy deposition in nearby crystals QGSP_BIC

15 180 MeV protons QGSP_BIC physics list Sum spectrum for entire block, full energy peak appears, ~80% of the events lie in the full energy peak 2.2 crystals out of 15 fire on average, 14 at most, width ~1 crystals

16 180 MeV protons QGSP_BERT

17 180 MeV protons QGSP_BERT physics list Sum spectrum for entire block, full energy peak appears, ~80% of the events lie in the full energy peak ~2 crystals out of 15 fire on average, 13 at most, width ~1 crystals

18 Light Collection Preliminary simulations to investigate light collection Input: –Photon emission spectrum, light yield, fast and slow time components –Need absorption length for tracking –G4LogicalBorderSurface with reflection properties of VM2000 was used for the simulations D. Motta et al. NIM A 547 (2005) 368. J.D. Valentine et al. NIM A 325 (1993) 147.

19 Future Work Addition of reflector between crystals 2 nd prototype geometry Light collection in single crystals Threshold effects


Download ppt "Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden."

Similar presentations


Ads by Google