Video cameras and photometry Dave Herald. Background Occultations are usually step events When video introduced, it overcame issues of Personal Equation,

Slides:



Advertisements
Similar presentations
Astronomical Video Reduction Software 1 Hristo Pavlov IOTA 2011, 17 June 2011.
Advertisements

Use of Registax and LiMovie for the Reduction of Marginal Occultations Tony George Umatilla, Oregon.
Advanced CCD Workshop Arne A. Henden
Micron detector testing in Liverpool G. Casse – O. Lodge Laboratory, University of Liverpool.
By Kevin Saunders.  tml tml.
Using a DSLR to Study Variable Stars. Canon 450D - linear over a magnitude using RAW images with a specific setting.
Image Processing IB Paper 8 – Part A Ognjen Arandjelović Ognjen Arandjelović
Automatic measurement of pores and porosity in pork ham and their correlations with processing time, water content and texture JAVIER MERÁS FERNÁNDEZ MSc.
Spectroscopy of Saturn
ABRF meeting 09 Light Microscopy Research Group. Why are there no standards? Imaging was largely an ultrastructure tool Digital imaging only common in.
AOTA Asteroidal Occultation Time Analyser. AOTA is in Occult
By Tony George for 2013 IOTA Conference. Issues:  Many IOTA members are purchasing integrating CCD video cameras to expand the range of occultations.
Video enhances, dramatizes, and gives impact to your multimedia application. Your audience will better understand the message of your application.
{ Recent Developments in Tangra 3 and the ADV File Format Hristo Pavlov IOTA Meeting 2014, College Park, MD, 13 July 2014.
1 Basics of Digital Imaging Digital Image Capture and Display Kevin L. Lorick, Ph.D. FDA, CDRH, OIVD, DIHD.
A Primer on Image Acquisition and Data Reduction Using TheSky6, CCDSoft V5 and Microsoft Excel Thomas C. Smith Dark Ridge Observatory (DRO)
AOTA Asteroidal Occultation Time Analyser. AOTA is in Occult
…….CT Physics - Continued V.G.WimalasenaPrincipal School of radiography.
Different sources of noise in EM-CCD cameras
Digital Images Chapter 8 Exploring the Digital Domain.
Digital Images The digital representation of visual information.
Jupiter Mutual Events Sep 2014 to Aug 2015.
Fabian Salcedo EDTC Competency 004 The Master Technology Teacher knows and applies basic strategies and techniques for using digital video technology.
Updated Release of R-Code Occultation Timing Extractor Programmed by Robert L. (Bob) Anderson Presentation by Tony George at the 2014 Bethesda, Maryland.
Photon Transfer Method 1. Using two identical flat field exposures it is possible to measure the read noise of a CCD with the Photon Transfer method. Two.
Lab #5-6 Follow-Up: More Python; Images Images ● A signal (e.g. sound, temperature infrared sensor reading) is a single (one- dimensional) quantity that.
1 Image Basics Hao Jiang Computer Science Department Sept. 4, 2014.
Standards Subgroup Of the Digital Television Working Group Standards Subgroup Of the Digital Television Working Group UPDATE Presenter John Knox, Manager.
 Refers to sampling the gray/color level in the picture at MXN (M number of rows and N number of columns )array of points.  Once points are sampled,
VIDEO FORMATS Prof Oakes. Compression CODECS COMPRESSOR/DECOMPRESSOR A codec provides specific instructions on how to compress video to reduce its size,
Bit-Mapped Graphic Data: Input (Capture) Hardware Multimedia – Section 2.
1 Video Camera for Photometry: It can be done.. ….but… IOTA July 12, 2014 John Menke x x x
CCD Detectors CCD=“charge coupled device” Readout method:
Sensing for Robotics & Control – Remote Sensors R. R. Lindeke, Ph.D.
Asteroids Image Calibration and Setup Making a Lightcurve What is a Lightcurve? Cole Cook  Physics and Astronomy  University of Wisconsin-Eau Claire.
Measuring Sky Brightness with a Digital Camera Paris 2004.
Asteroids Rotation Period Study the photometric curve Rotation period Shape Is it binary? Surface composition spectroscopy.
Marwan Al-Namari 1 Digital Representations. Bits and Bytes Devices can only be in one of two states 0 or 1, yes or no, on or off, … Bit: a unit of data.
Computer Graphics & Multimedia
Physics 114: Lecture 8 Measuring Noise in Real Data Dale E. Gary NJIT Physics Department.
COMP135/COMP535 Digital Multimedia, 2nd edition Nigel Chapman & Jenny Chapman Chapter 2 Lecture 2 – Digital Representations.
Historically, lunar occultations were observed visually, and were treated as binary events – except for when a binary star was involved. Fading caused.
Faulkes Telescope North The identification of different modes of oscillation provides information about the stellar interior ~the science of asteroseismology,
Basic Detector Measurements: Photon Transfer Curve, Read Noise, Dark Current, Intrapixel Capacitance, Nonlinearity, Reference Pixels MR – May 19, 2014.
CCD Image Processing: Issues & Solutions. CCDs: noise sources dark current –signal from unexposed CCD read noise –uncertainty in counting electrons in.
April / 2010 UFOCapture 1 UFOCaptureV2 Time-Shift-Motion-Detect-Video-Recording software for complete records of un-expected events.
The Reduction and Reporting of Data On Proto-Planetary Nebulae From Two Observatories. By Wesley Cheek With Mr. Wen Lu & Prof. Bruce Hrivnak.
April / 2010 UFOAnalyzerV2 1 UFOAnalyzerV2 (UA2) the key of accuracy UA2 inputs video clip files and outputs meteor trajectories. UA2 does following steps.
CCD Calibrations Eliminating noise and other sources of error.
Master Technology Teacher Competency 4
Digital Light Sources First introduced in 2001.
UFOCaptureV2 Time-Shift-Motion-Detect-Video-Recording software for complete records of un-expected events April / 2010 UFOCapture.
UFOAnalyzerV2 (UA2) the key of accuracy
“ Who will I blame my mistakes on. ” Dr
Color Image Processing
Color Image Processing
CCD Image Processing …okay, I’ve got a bunch of .fits files, now what?
IMAGE ORTHICON.
Color Image Processing
Color Image Processing
T. J. Okamoto (NAOJ/Kyoto Univ.)
UVIS Calibration Update
Photometric Analysis of Asteroids
Karen Meech Institute for Astronomy TOPS 2003
COMS 161 Introduction to Computing
Transforming functions
Modern Observational/Instrumentation Techniques Astronomy 500
Kwoon Y. Wong, Felice A. Dunn, David M. Berson  Neuron 
Histogram The histogram of an image is a plot of the gray _levels values versus the number of pixels at that value. A histogram appears as a graph with.
Limovie for Lunar Occultations - 1
Presentation transcript:

Video cameras and photometry Dave Herald

Background Occultations are usually step events When video introduced, it overcame issues of Personal Equation, increased the timing precision, and provided a mechanism to re- play events Measuring the change in brightness was not important

Background #2 After several years experience, people became interested in measuring brightness changes Double star discoveries – measure the relative brightness of the components Occular – measure light drop and limiting magnitude, for event validation Mutual events of Jupiter and Saturns satellites – generate light curves Large stars – measure their diameter

Question How reliable are our analogue video cameras for photometry?

Traditional CCD camera CCD with array of pixels No anti-bloom gating on CCD (linearity issue) 1:1 correspondence between pixel and image file. Imaged represented at 16 bits Bias frame, dark frame and flat field applied to image Image with linear relationship to light intensity across whole field. Precision of mag readily obtainable with care.

Video issues #1 CCD with array of pixels Array of pixels converted into an analogue signal (x-direction), in multiple scan lines (y- direction) - with number of scan lines generally different to number of rows of pixels. horizontal axis is analogue representation of pixels; Vertical axis – formed by combining pixels in adjacent rows of the CCD 1:1 correspondence to CCD pixels lost

Video issues #2 Analogue signal digitised – to 8-bits Signal frequently compressed. Depending on compression algorithm: The compression is most likely not lossless; and May incorporate data from adjacent pixels in both the compression and decompression Data integrity compromised

Video – issues #3 CCD presumably has anti-bloom gating => non-linear response Video traditionally has a gamma correction applied => non-linear response Darks and flat fields are not usually applied => non-uniform fields Standard video images are not well suited to photometry

Example #1 - Derek Breit video Yellow star at 3,600 – Tycho V = 6.7 Pink star at 1,200 = 0.33 of yellow = 1.2 mag fainter => mag 7.9. HOWEVER Tycho V= 7.3 Pink star should be at height 2070 => Measured brightness star brightness

Example #2 – flat fielding Video of star near moon, 40cm ACF with 3x reducer. Plot shows field brightness in horizontal line across field & thru the star. Plot shows the background is 50% brighter in center of image

Example #2 – flat fielding Limovie & Tangra both measure a changing star brightness as it crosses the field – in this case more than a 50% change Variation in background illumination and star brightness consistent with a need for a flat field

Example 3 – camera response Integrating camera Change integration period – keeping stars in the same position. Measure star brightness If camera response is linear, ratios of star brightness should remain the same {Using brightness ratio avoids any need to precisely determine the exposure duration. Keeping stars in the same position avoids any flat-fielding issues}

Watec 120N+ with Gamma off 1 : 1.7 : 3 1 : 2 : 4 1 : 2.2 : : 2.5 : 7 1 : 2.4 : 9 Ratios relative to pink are: => Camera response definitely non-linear with respect to intensity

Watec 120N+ with Gamma hi 1 : 2 : : 2 : : 1.8 : : 1.2 : : 1.2 : 2.2 Ratios relative to pink are: => Camera response definitely non-linear with respect to intensity

Effect of gamma on long recordings Gamma changes the recorded brightness depending on the brightness of the object Star brightness changes as air mass changes (i.e. a star gets fainter as its altitude decreases) Without gamma, two stars (or moons) of similar brightness retain same brightness ratio With gamma, ratio of recorded brightness changes as star altitude changes. Normalising one object on the basis of another object of non-identical brightness will induce an apparent change in brightness as the altitude changes

Summary Compared to usual CCD photometry, analogue video photometry presents serious challenges Video systems are usually non-linear – need to understand the non-linearity in the recording system as a whole (camera + avi creator + recording software/hardware) Flats and darks are essential for decent photometry