Cargo Compartment alternative MPS testing using Low Pressure Dual Fluid Water Mist and Hypoxic Air International Aero Inc. FAA & JAA Repair Station IQNR108K.

Slides:



Advertisements
Similar presentations
ATR Combi & Freighter  Exit.
Advertisements

Chapter 3. HVAC Delivery Systems
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
Halon Replacement for Airplane Cargo Compartments What it Takes Fourth Triennial International Fire and Cabin Safety Research Conference Lisbon, Portugal.
Cargo Compartment Minimum Performance Standards for Gaseous Total Flood Agents FAA Technical Center Fire Safety Section, AAR-422 John Reinhardt Website:
A Different look At Inerting in Flight Ivor Thomas – Chief Scientific and Technical Advisor to the FAA, Fuel System Design.
International Aircraft Fire and Cabin Safety Conference Fuel Tank Inerting Modeling Ivor Thomas Consultant to FAA
Modeling of Fuel Tank Inerting for FAA OBIGGS Research
Presented by Phil Jones & Brian Greenawalt Shaw Aero Devices
WJH FAA Technical Center John W. Reinhardt
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
LITHIUM BATTERY FIRE TESTS Harry Webster FAA William J Hughes Technical Center
ISRU atmosphere harvesting Robert Dyck. Mars Atmosphere CO % N 2 2.7% Ar1.6% O % CO0.07% H 2 O0.03% Ne % Kr % Xe % O 3.
Protective Packaging and Materials Handling
Fire Suppression Techniques Part 2
3.7.6 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Conducting Container Vapor Flaring Operations Before.
Watertube Boiler.
Lithium Metal and Lithium-ion Battery Packaging Development 2014.
Introduction Hydrogen has been successfully used in industry for decades, but current safety codes and standards must be updated for the situations encountered.
Important Terms & Notes Feb. 24 & 25, Phases of Matter Phase: The State in which Matter exists at given Environmental and Energy conditions Five.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
Engineer Presentation
Drug Delivery & Tissue Engineering Laboratory
Cargo Bay Fire Protection with a Fuel Tank Inerting System William Cavage AAR-440 Fire Safety Branch Wm. J. Hughes Technical Center Federal Aviation Administration.
Installation and Initial Start Up by Martin Noska, Service Engineer, Aftersales & Service.
Hydraulics.
Engine Intro & Basic Induction
1 VACUUM ATMOSPHERES Co NEW PRODUCT ANNOUNCEMENT November 28, 2001.
AIRCRAFTS HYDRAULIC SYSTEM
Aircraft Cargo Compartment Fire Detection David Blake FAA William J. Hughes Technical Center Atlantic City Airport, NJ Phone:
Modeling of Single Bay Fuel Tank Inerting for FAA OBIGGS Research
LNG Hazards.
International Aircraft Systems Fire Protection Working Group March Hosted by John Brooks International Aero Inc Fire Protection Laboratory
STEAM HEATING.
Fuel Tank Inerting Joint Airbus/FAA, A320 Flight Tests
CHAPTER 6 Moving Heat: Heating and Air Conditioning Principles
Kidde Engineered Fire Suppression System 25 bar Equipment Hardware Engineered for use with 3M™ Novec™ 1230 Fire Protection Fluid.
B757 Review Questions.
Inerting Background Inerting refers to rendering the ullage (air above fuel) unable to propagate a reaction given flammable conditions and ignition source.
Flight Testing of the FAA OBIGGS On the NASA 747 SCA
Full Scale Battery Fire Test Plan
Properties of Matter Chapter Four: Density and Buoyancy
John Reinhardt FAA Fire Safety Section, AAR-422. BULK LOAD FIRESCONTAINERIZED FIRES FLAMMABLE LIQUIDS FIRE AEROSOL CAN EXPLOSION SIMULATION “Minimum Performance.
Systems Fire Protection Working Group DTA - Grenoble, France June 21-22, 2003 FAA Inerting System Flight Testing on an Airbus A320 William Cavage AAR-440.
1 HVACR215 – Mechanical for Oil Oil Combustion. 2 Combustion The burning of a substance. Rapid Oxidation The burning of a substance. Rapid Oxidation.
Presented to: By: Date: Federal Aviation Administration In-Flight Burn- Through Tests Aluminum vs. composite materials Aircraft Systems Fire Working Grp.
Facilities Engineering *1 st draft By: Saha. Development options ProposalDevelopment OptionEstimated Cost (Mil) A FPSO converted to Tanker Hull 300 kbo.
Presented to: International Aircraft Systems Fire Protection Working Group. Atlantic City, NJ By: Dave Blake. FAA Technical Center. Atlantic City, NJ.
Cargo Bay Fire Protection with a Fuel Tank Inerting System
Full-Scale Ground-Based Inerting ___________________________________ AAR-422 Fire Safety R&D July 17-18, 2001 International Aircraft Systems Fire Protection.
OBIGGS Sizing Data for Transport Canada Trade Study William Cavage AAR-440 Fire Safety Branch Wm. J. Hughes Technical Center Federal Aviation Administration.
March 26-27, 2003 International Aircraft Systems Fire Protection Working Group Phoenix, Az Inerting of a Scale 747SP Center-Wing Fuel Tank During a Typical.
Presentation to Transport Canada November 2008 – Fire & Cabin Safety Research Integrated Fire Protection Systems – Update.
October 30-31, 2002 International Aircraft Systems Fire Protection Working Group Atlantic City, NJ Inerting of a Scale 747SP Center Wing Fuel Tank During.
Fuel Cell By-Products for Cargo Hold Fire Suppression
FAA R&D Efforts on Flammability Ivor Thomas Chief Scientific and Technical Advisor to the FAA, Fuel System Design August 14th 2002
Systems Fire Protection Working Group DTA - Grenoble, France June 21-22, 2003 Preliminary Results of FAA Fuel Tank Inerting Flight Testing on the NASA.
R.G.W. Cherry & Associates Limited #1 INTERNATIONAL AIRCRAFT SYSTEMS FIRE PROTECTION WORKING GROUP MEETING AN INTEGRATED FIRE PROTECTION SYSTEM.
Subpart F - Fire Protection & Prevention ( ) Flammables/combustibles - Approved containers Fire protection program/equipment 2A fire extinguishers.
Manoj kumar 2009JE0406 Mining machinery engineering.
Air Line Pilots Association, International EMB 145 Oral Questions Emergency/Abnormal Procedures Select “Slide Show” Use the space bar on your computer.
FGUP “Federal center for dual-use technologies “Soyuz"
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
14 Refrigerant Recovery, Recycling, and Recharging.
UNIT IV AUXILIARY SYSTEM
Power Plant Engineering. Boilers Boilers Boiler is an apparatus to produce steam. Thermal energy released by combustion of fuel is used to make steam.
FAA R&D Efforts on Flammability
1 INTERNATIONAL MARITIME COLLEGE OMAN PROCESS TECHNOLOGY & SYSTEMS (TPTS & PT-TPTS) PE (TPTS & PT-TPTS) (Chapter-3) Chapter - 3 Distillation Systems Textbook.
Behaviour of M2 & M3 general construction in case of Fire Event
Presentation transcript:

Cargo Compartment alternative MPS testing using Low Pressure Dual Fluid Water Mist and Hypoxic Air International Aero Inc. FAA & JAA Repair Station IQNR108K Fire Protection Laboratory International Aircraft Systems Fire Protection Working Group November 5-6, 2003

System Participants IAI FirePASS Air Liquide

Background Started looking at misting in 1998 as a Halon alternative along with condensed aerosols. Full scale Cabin ground based testing May 1999 Flight test Aug 2001 Rebuilt the MPS device in May 2003 Testing on going

We reconstructed the Cargo M PS device Data collection in a LD3 cargo pallet alongside

Low Pressure Dual Fluid Nozzle US Navy patent IAI holds license works at 0.8 to 12 bar Liquid and gas are equal pressure

Why LPDF Simple Hard to clog or plug Makes the same size droplet through out the operating range (50 micron) Instills a tremendous amount of kinetic energy in the droplet for distribution Adjustable flow rates from the same nozzle (1-15 liters per minute)

System Goals Use existing systems and equipment where ever possible Be lighter, cheaper and, more efficient With a lower overall life time cost be ready for the future Be better than any gas system, Level of safety longer duration lower temperatures less damage to the air vehicle

Extinguishing Agent chemistry Name Air ; (Hypoxic Air) –Snap listed in July 2003 UN Transportation Code UN1002 Gas Properties: Gas density (1.013 bar at boiling point) : 3.2 kg/m 3 Specific gravity (air = 1) (1.013 bar and 21 °C (70 °F)) : 1 Specific volume (1.013 bar and 21 °C (70 °F)) : m 3 /kg Normal composition of dry air: –Gas Concentration (% vol. ) ppm or ppbAgent –N % –CO2.330 ppm –H2 500 ppb –O % 15.2% or 10% –Ne 18 ppb –Xe 86 ppb –Ar 0.93% –He 5.2 ppm –Rn ppb –Kr 1.1 ppm

Hollow Membrane Diagram (it’s just a bunch of small tubes that leak O 2 )

Key to system Air Liquide “MEDAL” Air Separation Reverse Osmosis Membrane Air flow Air conditioning Packs Bleed air from Engines or APU Nov 2003 IAI proprietary Control selector valve Re circulated Hypoxic Air On OFF

MEDAL Membrane Filter Hypoxic air out to the system Bleed air or re-circulate air 20.97% O 2 Hypoxic 10% O 2 O 2 out

Basic layout 10% 21% Alarm mode closed Flow controllers 10% 21% 10% 21% 10% 21% 10% 21% Air conditioning flow System controller and O2 monitoring Clean out Nov 2003 IAI proprietary

Start / Taxi block diagram Preventive mode Airpack System 1,2,3 flow bleed air until 15.2% O 2 4,5 available if required >15.2% O 2 Nov 2003 IAI proprietary H2OH2O

Climb block diagram Preventive mode Airpack Climb 15.2% O 2 2, 3 recycle 1 make up for leakage if required >15.2% O 2 Nov 2003 IAI proprietary H2OH2O

Cruise block diagram Preventive mode Airpack >15.2% O 2 Nov 2003 IAI proprietary Cruise only a small maintenance flow requirement H2OH2O

Descent block diagram Preventive mode Airpack >15.2% O 2 Nov 2003 IAI proprietary Descent will require a flow larger to make up for decrease in altitude H2OH2O

Alarm Block Diagram Inert mode Airpack >10% O 2 Alarm all MDEAL filters on at max flow to bring the Cargo bay to below 12.2 % O 2 Water mist for temp control H 2 O via LPDF mister Nov 2003 IAI proprietary

Post Alarm Descent block diagram Inert mode Airpack >12.2% O 2 Water off reduced O 2 flow is maintained until airport ARFF crew on scene H2OH2O Nov 2003 IAI proprietary

Fusion of two technologies Advantages –uses existing systems –light weight –simple –will operate as long as the engines are running –“Gate to Gate” suppression –No existing or foreseen future environmental impacts –easily expandable for SFAR 88 or hidden fires, cabin water mist –we are extinguishing the fires Obstacles –New technology –New paradigm in fire suppression –will be hard due to existing thoughts on protection are “it needs to be a GAS” Nov 2003 IAI proprietary

Bulk Load Temp profile

Bulk load MPS profile

Container load Temp

Container load

Surface load (high) temp

Surface load (high) MPS

Surface load (Mid) Temp

Surface load (Mid) MPS

Phase II FirePASS Preventive Use the Bulk load igniter box Place in center of the Cargo MPS device reduce the O2 to 14% apply power to the NiCrome wire Wait for the smoke to clear. Did two test to date 45 minute and 90 minute

Test one last Thursday 45 minute with power applied Temp went to 325 F for 10 minutes then stabilized at 145 F Some char and discoloration inside the box NO FLAMES detailed data at

Test two last Friday Same test set up –(same box with new paper) 90 minute test Power applied at 14% oxygen content T=0 Temps +350 F for 20 minutes after temp drop and stabilized at 137 F, we increased the O2 by 1% every 20 minutes ignition wire dropped and burned through the bottom of the box with NO FLAMES We started to see a 40 Deg F temp rise at 15.2% O2 at T+84 minutes. Stopped the test at 90 minutes future test planned

Data was collected with virtual instruments constructed with “National Instruments” LabView DAQ software and a SCXI signal conditioner Test data and remote video observations available via TCP/ IP connection Data is updated and posted at For further information contact: John Brooks Director of Research International Aero Inc Westar Lane Burlington Wa P F

“Your Interior Configuration Specialist” Thank You No Animals real or imaginary were injured while performing these test