Overview of Liquid Cooling Systems Peter Rumsey, Rumsey Engineers.

Slides:



Advertisements
Similar presentations
Presented by Paul Almond – Datacentre UK
Advertisements

Trane Voyager™ rooftop units
HEALTHCARE BUILDING AUTOMATION
1 Optimizing the Efficiency of the NCAR-Wyoming Supercomputing Center Ademola Olarinde Team Member: Theophile Nsengimana Mentor: Aaron Andersen August.
Heat Recovery for Commercial Buildings
1Taylor Engineering, LLC Group Think Mark Hydeman, P.E., FASHRAE Taylor Engineering, LLC
Smart Devices. Smart Buildings. Smart Business The Potential for DCx Technology Enabled HVAC Operation Scot Duncan, P.E.
Using Benchmarking to Identify Energy Efficiency Opportunity in Cleanrooms; The Labs 21 Approach William Tschudi and Peter Rumsey June 29, 2004
Cooling Product Positioning
Cloud Computing Data Centers Dr. Sanjay P. Ahuja, Ph.D FIS Distinguished Professor of Computer Science School of Computing, UNF.
PG&E and Altera Data Center Energy Efficiency Project.
The art of Engineering. INDUSTRIAL COOLING SYSTEMS.
IT Equipment Efficiency Peter Rumsey, Rumsey Engineers.
Utility-Function-Driven Energy- Efficient Cooling in Data Centers Authors: Rajarshi Das, Jeffrey Kephart, Jonathan Lenchner, Hendrik Hamamn IBM Thomas.
ENERGY CONSERVATION IN CCIS HEADQUARTERS BUILDING IN LJUBLJANA Jože Renar Chamber of Construction and Building Materials Industry of Slovenia.
Copyright Green Revolution Cooling
PUNTO ENERGIA Experience in Implementing and installing co-generation and energy- saving schemes Eng. Michele Vio President of AICARR Eng.
Solar Energy Technology for Commercial Facilities John Archibald American Solar, Inc. Association of Energy Engineers Baltimore Chapter.
Integration of Mechanical System Redesign Geothermal Heat Pump Redesign Wesley S. Lawson Architectural Engineering Mechanical Option Pennsylvania State.
Steve Craker K-12 Team Lead Geoff Overland IT and Data Center Focus on Energy Increase IT Budgets with Energy Efficiency.
Building Systems Integration - Energy and Cost Analysis The Milton Hershey School New Supply Center Justin Bem AE Senior Thesis – Spring 2007 Mechanical.
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
Best Practices in HVAC Design/Retrofit
Introducing. The Comfort Zone (75° /50% RH) Every HVAC system is trying to hit this target. Hot, humid climates High latent load. The Challenge:
Chilled water Meyrin consolidation Study 1 st Part Many thanks for their contribution to: Pasquale Alemanno, Fortunato Candito, Alexander Putzu.
Air Conditioning and Computer Centre Power Efficiency The Reality Christophe Martel Tony Cass.
Lecture Objectives: Finish with HVAC Systems Discuss Final Project.
COMP 4923 A2 Data Center Cooling Danny Silver JSOCS, Acadia University.
Mission Energy: Energy Efficient Cooling How Data Centre energy consumption and operating costs can be significantly reduced through readily available.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
N O R T H A M E R I C A C O M M E R C I A L TDP
November 2004 Low Hanging Fruit Low Cost Energy Efficiency Opportunities in Cleanrooms.
Overview of Data Center Energy Use Bill Tschudi, LBNL
Lecture Objectives: Clarify issues related to eQUEST –for midterm project Learn more about various HVAC - economizer - heat recovery Discuss about the.
The Data Center Challenge
Introduction to HVAC Optimization
1 LBT Q Engineering Review PLMG: Plumbing, includes IC system, chiller systems, instrument lab cooling, and LUCIFER cryo-compressor cooling.
We can…. 2 GLOBAL REFERENCES Rev: 00 References :
COMP 4923 A2 Data Center Cooling Danny Silver JSOCS, Acadia University.
IMPROVING THE EFFICIENCY GEOTHERMAL or GROUND SOURCE HEAT PUMPS.
Building Systems Integration - Energy and Cost Analysis The Milton Hershey School New Supply Center Justin Bem AE Senior Thesis – Spring 2007 Mechanical.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Row Cooling.
Ventilation & Airflow NetShelter CX 18U,24U,38U Ambient office air is drawn in to the soundproofed air-intake chambers on either side of the NetShelter.
ESKOM - MWP NEW ENERGY CENTRE Mechanical Installation 16 April 2014.
[Eco 2 System] A Fundamental Twist To Data Centre Cooling Ecological Friendly & Economical.
GeoExchange / Thermal Energy Storage Systems Reduce Overall Energy Use and Peak Demand.
Dell EMC Modular Data Centers
Elliott Microturbines Absorption Chiller Integrated System Development
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
The Data Center Challenge
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Lecture Objectives: Discuss Final Project
Integrating a Data Center into an Engineering Laboratory Building
Heat Pumps For Energy Efficient / Economical Hot water Generation
Using Heat to Increase Cooling George Hannah BEng (Hons) CEng MIMechE
CERN Data Centre ‘Building 513 on the Meyrin Site’
Lecture Objectives: Continue with Sorption Cooling
Date of download: 12/16/2017 Copyright © ASME. All rights reserved.
Lecture Objectives: Answer questions related to HW 4
HVAC EQUIPMENT General
Closing the Gap to Free Cooling in the Data Center
P20 Thermal energy storage with PCM for energy systems in buildings
Lecture Objectives: Answer questions related to HW 4
Energy Efficiency in District Coiling System
Chilled Beam Performance:
Cloud Computing Data Centers
Frenger “Radiant” chilled beam performance at 1 Shelly St - Sydney
Cloud Computing Data Centers
Overview: Room ASM - AC/S 1.x.1
Presentation transcript:

Overview of Liquid Cooling Systems Peter Rumsey, Rumsey Engineers

Outline What is liquid cooling? Energy Benefits What is water side economizer Combined benefits

Why Liquid Cooling? Heat Capacity of this much air = Heat Capacity of this much water

Fans move energy less efficiently

Liquid Cooling Closer coupling between cooling source and server

Liquid Cooled Racks Racks with integral coils

Yesterday

Today

Comparison of Conventional Cooling to Liquid Cooling – 1,000 kW data center load Cooling Towers and Pumps ChillerChilled Water Pumps FansOtherTotal Power (kW) % SAVINGS Traditional System - 45 Deg F Chilled Water n/a770N/A Liquid Cooled with Fans in the Rack - 55 Deg F Chilled Water n/a64516% Liquid Cooled without fans in the rack - 55 Deg F Chilled Water n/a54529% Liquid Cooled directly couple with CPU - 70 to 80 deg F Chilled Water Room A/C %

Free Cooling Use cooling towers and heat exchanger to produce chilled water Turn off chiller

Three – Well Suited For 24 hr Load

Put in series with chiller free cooling can improve reliability

Free Cooling

Comparison of Conventional Cooling to Liquid Cooling – 1,000 kW data center load With Free Cooling Cooling Towers and Pumps ChillerChilled Water Pumps FansOtherTotal Power % SAVINGS Traditional System - 45 Deg F Chilled Water n/a770N/A Liquid Cooled with Fans in the Rack - 55 Deg F Chilled Water n/a47538% Liquid Cooled without fans in the rack - 55 Deg F Chilled Water n/a37551% Liquid Cooled directly couple with CPU - 70 to 80 deg F Chilled Water Room A/C %

Take Aways Liquid has greater heat removal capacity Pumps are more efficient than fans Coupling heat removal to the source eliminates mixing Commercially available liquid solutions are available Water side free cooling provides cooling with reduced chiller operation for much of the year in California

Thank You