Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Commercial Kitchen Cooking Measures Convection Ovens, Combination Ovens, Dishwashers.

Slides:



Advertisements
Similar presentations
Y.LUBRINA 26/11/10 Food Equipment TGCP Combis Combis Overview on Ranges TGCP Products.
Advertisements

Residential Refrigerators and Freezers UES Measure Update Regional Technical Forum October 14, 2014.
 Using the “How to Read the EnergyGuide Label” and EnergyGuide examples fill in the template below (1) Estimated Yearly Operating Cost (Natural gas water.
Residential Single Family Clothes Washer UES Measure Update Christian Douglass Regional Technical Forum February 18, 2015.
D EEMED M EASURE R EVIEW P ROJECT Final Report December 7, 2010 Regional Technical Forum Presented by: Michael Baker.
1 Proposed Revision to Energy Star New Homes Deemed Savings September 19, 2008.
Energy Star and Government Purchasing Craig Hershberg, EPA Jeff Harris, LBNL Power Supplies Workshop San Francisco, CA January 14, 2002.
Lumped Burrito Using Lumped Capacitance to Cook a Frozen Burrito Chad Pharo & Chris Howald ME EN 340 Heat Transfer Project.
MVP House in Montana Energy Savings and Costs March 2 nd, 2009 Regional Technical Forum 1.
ENERGY STAR Commercial Food Service (CFS) Equipment January 2010.
ENERGY STAR ®. Earning the ENERGY STAR ® means a product meets strict energy efficiency guidelines set by the US Environmental Protection Agency and the.
Foods and Nutrition Unit 5 Kitchen Appliances Tonja Bolding Lakeside High School Revised 2008.
5 Small Saver Cooking Measures Fryers, Holding Cabinets, Convection Ovens, Combination Ovens, Steamers Regional Technical Forum July 16, 2013.
AVAILABLE AS A FREESTANDING STOVE Kenmore Elite Induction Top Range.
Prescriptive Duct Sealing UES Measure Proposal Regional Technical Forum Subcommittee July 8, 2013.
Dairy Milking Machine Vacuum Pump VFD Savings Calculator Follow-up from the last RTF meeting with more field data Regional Technical Forum December 7,
Kitchen Appliances Mrs. Filinov HFN 2O1 Food and Nutrition Mrs. Filinov.
1 Quality Control Review of E3 Calculator Inputs Comparison to DEER Database Brian Horii Energy and Environmental Economics, Inc. November 16, 2006.
Tracking Energy Savings from the Energy Star % Televisions Program By Christina Steinhoff.
Northwest Power and Conservation Council Deemed Energy Savings and Cost-Effectiveness of 80-Plus Power Supplies RTF January 2007.
Commercial Refrigerators and Freezers
Plans to bring Out-of-Compliance UES Measures back into Compliance: 1. Agricultural Irrigation Hardware UES 2. Agricultural Motors UES Regional Technical.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential Appliance Measure Updates Danielle Gidding Bonneville Power Administration.
Pre-Rinse Spray Valve Small Saver UES Measures Regional Technical Forum September 17, 2013.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential LED Recessed Down light Fixtures RTF January 4, 2011.
Out-Of-Compliance Grocery UES Measure Recommendations Regional Technical Forum March 18, 2014.
Standards and Benchmarking for Energy Efficient Products Rod Janssen HELIO International and eceee September 23, 2009 Geneva.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Smart Power Strips in Commercial Office Applications RTF October 4, 2011.
Proposed Deemed Savings Rates for Energy Star 3.0 Plus 30% Televisions By Christina Steinhoff May 2, 2010.
Standard Information Workbook (SIW) Update Proposal Regional Technical Forum May 13, 2014.
Lodging Market Initiative April 10, Overview Lodging + Foodservice Market Overview Energy Trust + BPA Collaboration Food Service Technology Center.
Drought Busting and Carbon Crushing technologies in Food Service Kong Sham June 17, 2014 Fisher Nickel Inc. Food Service Technology Center Presented by:
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential Appliance Measure Updates Danielle Gidding Bonneville Power Administration.
Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 4/14/2015.
Deemed Savings Update: ECMs in Display Cases Ben Cartwright PECI January 5, 2009.
Hot Food Holding Cabinets, Steamers, and Fryers RTF Meeting 5/5/2009.
10 Turn off Lights Not in Use Motion Sensors simple ways to go green
© 2012 CLEAResult │ All rights reserved. 1 Overview of New Deemed Refrigeration, Food Service and Controls Measures EEIP MeetingNovember 27, 2012.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Energy Savings from Electric Water Heaters in Commercial Applications Danielle Gidding.
Northwest Power and Conservation Council Residential Conservation Resource Assessment Overview of Analytical Process and Major Assumptions April 21, 2009.
Page 404 SciencePower 9. Think about it In every step between mining coal, generating electricity, transmitting it to your home and lighting a lamp some.
1 Analysis of Cost and Savings Values for Revised Energy Star Dishwasher Specifications June 6, 2006 Revised August 8, 2006.
ENERGY STAR Criteria for Clothes Washers Overview of ENERGY STAR Criteria Setting Process and History of Clothes Washer Criteria Richard H. Karney, P.E.
Electrical Efficiency. Electrical Efficiency Electrical Energy Consumption: the amount of electrical energy used.
1 Analysis of Cost and Savings Values for Revised Energy Star Dishwasher Specifications June 6, 2006.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump Sub-Committee Alternative Incentive Approaches BPA Energy.
Beyond NEMA Premium Using CEE Motors List 1. Savings Summary Worksheet 2.
1 Analysis of Two-Tiered Deemed Savings Values for Energy Star Clothes Washers February 10, 2004.
Commercial Ice-Makers May 27, 2008 RTF Meeting Calculator Update.
Commercial Refrigerators and Freezers Efficiency Standards, Savings, and Cost RTF Meeting July 1, 2008.
Proposed Deemed Savings Rates for Energy Star 3.0 Plus 30% Televisions By Christina Steinhoff June 1,
1 Analysis of Cost and Savings Values for Revised Energy Star Dishwasher Specifications June 6, 2006 Revised August 8, 2006 Revised Again January 23, 2007.
Hot Food Holding Cabinets, Steamers, and Fryers RTF Meeting 2/3/2009.
Commercial Clothes Washer UES Measure Update Regional Technical Forum April 16, 2013.
RTF Delivery Verification Guidance Batch 2 Jennifer Anziano Regional Technical Forum September 22, 2015.
Residential Refrigerator UES Measure Update Regional Technical Forum April 16, 2013.
ENERGY STAR Commercial Refrigerators and Freezers Regional Technical Forum January 21 st, 2016 Mohit Singh-Chhabra.
Unit 5—Kitchen Appliances
RTF Management Updates Jennifer Light Regional Technical Forum January 21, 2016.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential Appliance Measure Updates Dishwashers Danielle Gidding Bonneville Power Administration.
1 Analysis of Cost and Savings Values for Revised Energy Star Dishwasher Specifications June 6, 2006 Revised August 8, 2006 Revised Again January 23, 2007.
Energy Consumption Energy consumption is measured in kilowatt. hours. A kilowatt hour is the amount of energy being consumed per hour. –Energy (kwh) =
Residential Single Family Clothes Washer UES Measure Update Regional Technical Forum September 16, 2014.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N BPA Commercial Showerhead Research Plan RTF April 6 th, 2010 Danielle Gidding.
Commercial Efficient Tank Water Heater UES Measure Update Regional Technical Forum December 17, 2013.
RTF Management Updates Jennifer Light Regional Technical Forum February 17, 2016.
Commercial Refrigerators and Freezers Cost & Cost-Effectiveness RTF Meeting March 2nd, 2010 (continued from Feb 2 nd, 2010 meeting, with more Cost discussion.
1 Energy Star LED Recessed Downlights: First Look at Deemed Savings and Cost- Effectiveness for Residential Retrofit Applications January 8, 2008.
Saving Energy Simply Not Your Cup Of Tea? The Eco3 Electronic Kettle James Brewster.
1 EE Kitchen equipment.
Presentation transcript:

Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Commercial Kitchen Cooking Measures Convection Ovens, Combination Ovens, Dishwashers Sponsored by BPA Tim Steele Prepared by EMP2, Inc. David Frank & Le Tran

Slide 2 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Project Goals For Combination Ovens, Convection Ovens, and Commercial Dishwashers: Approval of deemed savings and incremental cost. Plan to present one measure at a time for simplicity and ask for approval after each measure has been presented and discussed with RTF. 1.Establish current practice for baseline cooking equipment. Then develop the baseline criteria. 2.Establish a high efficiency criteria for cooking equipment 3.Develop an energy savings calculator. 4.Develop cost and incremental cost information.

Slide 3 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Convection Ovens Fully enclosed insulated chamber used to heat food. High Efficiency Equipment Improvements: 1.Increased Insulation 2.Improved Controls 3.Double Pane Glass 4.Infrared Burners 5.Halogen Lamps (infrared & visible) Energy Star Qualifying Parameters 1.Cooking Energy Efficiency 2.Idle Energy Rate (kW)

Slide 4 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Convection Oven Market Analysis Needed to determine if the large majority of the equipment being purchased is energy or non-energy star equipment. This gives us our market penetration. Based on a Best in Class Study done by Food Service Equipment and Supply, EMP2 was able to determine the top manufacturers. EMP2 then determined the % of units that qualify for Energy Star. Based on market research the overall market penetration of Energy Star equipment is around ~15%. Therefore EMP2 recommends using non-energy star rated equipment as the baseline.

Slide 5 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Convection Oven Baseline Little or no information available on low efficiency equipment. Not published or shared by manufacturer. Relied on FSTCs estimates for typical efficiencies. FSTC has tested a wide range of equipment and has developed a base case, typical case, and high efficiency case based on the population of tested equipment. EMP2 used FSTCs typical case as the baseline since it represents an intermediate point between the low efficiency equipment and high efficiency equipment. Basically a representative figure for the entire market.

Slide 6 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Convection Oven High Efficiency Criteria Used same high efficiency rating as Energy Star. However, the savings are based off an average efficiency of high efficiency Equipment. The calculator uses 75% cooking efficiency instead of 70%. Same idle energy rate in calculation due to limited data for half size unit.

Slide 7 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Convection Oven Calculation

Slide 8 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Convection Oven Calculation Assumptions

Slide 9 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Convection Oven Incremental Cost Averaged sales price for non-Energy Star rated equipment and energy star rated equipment. The difference between these two numbers was used as the incremental cost. Due to limited half-size data EMP2 used the same incremental cost for full and half size equipment. Average combined sales price of non-Energy Star rated equipment $5,628 Average combined sales price of Energy Star rated equipment $5,843 Incremental cost is $215.

Slide 10 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Convection Oven Summary

Slide 11 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Dishwashers A machine designed to clean and sanitize kitchenware by applying sprays of detergent solution and a sanitizing final rinse. High Efficiency Equipment Improvements 1.Reduced Water Use (Mfg Specific) 2.Water Re-Use 3.Improved Controls (Standby Mode, Sensors) Energy Star Qualifying Parameters 1.Water Consumption (gal/rack) 2.Idle Energy Rate (watts) 3.High/Low Temperature 4.Four Types of Dishwashers

Slide 12 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Dishwasher Market Analysis Energy Star and CEE came out with specifications in late The 2008 Energy Star Penetration report shows an Energy Star penetration rate of 83%. It includes reports from 19 manufacturers. Based on EMP2 market research the overall market penetration of Energy Star equipment over 50%. Therefore, the baseline will be Energy Star rated equipment.

Slide 13 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Baseline/High Efficiency Methodology The top 9 or top 25% of the units yearly kWh consumption was averaged for the high efficiency standard The remaining 26 or bottom 75% of the units kWh consumption was averaged for the base case efficiency

Slide 14 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Dishwasher Baseline Used Energy Star equipment qualification list as market list. The bottom~75% of equipment off the qualification list was used as the baseline. This was done since approximately ~25% of the market is non-energy star rated equipment. The average yearly kWh consumption of the bottom 75% of the equipment was used as the baseline.

Slide 15 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Dishwasher High Efficiency Criteria Selected top 25% off Energy Star List. The average yearly kWh consumption of the top 25% of the units was used as the high efficiency criteria/rating.

Slide 16 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Dishwasher Calculation

Slide 17 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Dishwasher Calculation Assumptions

Slide 18 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Dishwasher Incremental Pricing

Slide 19 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Dishwasher Summary

Slide 20 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Combination Ovens A convection oven that includes the added capability to inject steam into the oven cavity for cooking purposes. Three modes of operation, convection oven, steamer, combination. Energy Efficient Equipment Improvements 1.Increased Insulation 2.Double Pane Glass 3.Improved Controls FSTC Qualifying Parameters (No Energy Star nor CEE) 1.Cooking Efficiency (%) 2.Idle Energy Rate (kW) 3.Water Consumption (gal/hr)

Slide 21 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Combination Ovens Market Analysis Not rated by either Energy Star or CEE ASTM is in the process of revising their testing procedure for Combi-Ovens. This will modify the existing efficiency ratings. Energy Star and CEE will develop a standard after the new ASTM testing procedure is published. FSTC has developed a rating for high efficiency equipment based on the current ASTM testing standard. Based on market research the overall market penetration of FSTC Equipment is around ~12% when compared to FSTC high efficiency program. Therefore EMP2 recommends using the non-FSTC rated equipment as the baseline.

Slide 22 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Combination Oven Baseline Little or no information available on Low Efficiency Equipment. Not published or shared by manufacturer. Relied on FSTC’s estimates for typical efficiencies. FSTC has tested a wide range of equipment and has developed a base case, typical case, and high efficiency case based on the population of tested equipment. EMP2 used FSTC’s typical case as the baseline since it represents an intermediate point between the low efficiency equipment and high efficiency equipment. Basically a representative figure for the entire market.

Slide 23 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Combination Oven High Efficiency Criteria Developed high efficiency standard off list of tested equipment. However, the savings are based off an average efficiency of high efficiency equipment. The calculator uses 75% cooking efficiency and a 2.3 idle energy.

Slide 24 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Combination Oven Calculation

Slide 25 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Combination Oven Assumptions

Slide 26 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Combination Incremental Price Averaged Sales Price for non-FSTC rated Equipment and FSTC rated equipment. The difference between these two numbers was used as the incremental cost. The average sales price for non-FSTC rated equipment based on 5 units is $13,788. The average sales price for energy star rated equipment based on 4 units is $11,805. The incremental cost is $1,983.

Slide 27 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Combination Oven Summary