Measurement of Kr background in the XMASS experiment ICRR master’s course in physics Keisuke Hieda 1.

Slides:



Advertisements
Similar presentations
Lecture 8b Gas Chromatography.
Advertisements

Gas Chromatography.
A. Alton 1, H. O. Back 2, C. Galbiati 2, A. Goretti 2, C. Kendziora 3, B. Loer 2, D. Montanari 2, P. Mosteiro 2, S. Pordes 3 1)Augustana College 2)Princeton.
Status of the XMASS experiment S. Moriyama for the XMASS collaboration Kamioka observatory, Institute for Cosmic Ray Research, Univ. of Tokyo, July 27,
Study of alpha backgrounds using flash ADC in the XMASS experiment Feb. 22nd, 2013 ICRR, Suzuki-Lab. M2 Osamu Takachio.
M. Carson, University of Sheffield, UKDMC ILIAS-Valencia-April Gamma backgrounds, shielding and veto performance for dark matter detectors M. Carson,
1 Search for the Flavor-Changing Neutral-Current Decay,   → p     HyangKyu Park University of Michigan, Ann Arbor for the HyperCP collaboration.
DMSAG 14/8/06 Mark Boulay Towards Dark Matter with DEAP at SNOLAB Mark Boulay Canada Research Chair in Particle Astrophysics Queen’s University DEAP-1:
Status of Ultra-low Energy HPGe Detector for low-mass WIMP search Li Xin (Tsinghua University) KIMS collaboration Oct.22nd, 2005.
Prospects for 7 Be Solar Neutrino Detection with KamLAND Stanford University Department of Physics Kazumi Ishii.
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
The XENON Project A 1 tonne Liquid Xenon experiment for a sensitive Dark Matter Search Elena Aprile Columbia University.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Atomic-Absorption (AA) Spectroscopy 
Preliminary Results of the Test Run at SLAC Petra Hüntemeyer.
Krypton source for the Project 8 neutrino mass experiment Arman Ballado Advisor: Mike Miller.
Engineering Runs on Y(3S). The Cosmic Mystery-Pie o% antimatter WIMPs (Weakly-Interacting-Massive-Particles) are good dark matter candidates.
PANDAX Results and Outlook
Search for Dark Matter at CJPL with PANDAX
Depleted Argon from Underground Sources Henning O. Back – Princeton University For the DarkSide experiment, E-1000 Augustana College – D. Alton FNAL –
30 Ge & Si Crystals Arranged in verticals stacks of 6 called “towers” Shielding composed of lead, poly, and a muon veto not described. 7.6 cm diameter.
IDEA Meeting, LAL-Orsay, April 2005 Purification of nitrogen (argon) Grzegorz Zuzel MPI-K Heidelberg.
A feasibility study for the detection of SuperNova explosions with an Undersea Neutrino Telescope A. Leisos, A. G. Tsirigotis, S. E. Tzamarias Physics.
Chad Orzel Union College Physics Radioactive Background Evaluation by Atom Counting C. Orzel Union College Dept. of Physics and Astronomy D. N. McKinsey.
Chemical Ideas 7.6 Chromatography. The general principle. Use – to separate and identify components of mixtures. Several different types - paper, thin.
Lee, Myeong Jae DMRC, Seoul national university
Cygnus 2013/06/05 Nagoya univ. H.Uchida for XMASS collaboration 1.
Integration of a Clover Detector with the necessary electronics and computer program to utilize the ADDBACK method An SP496 and Capstone Research Project.
Status of DRIFT II Ed Daw representing the DRIFT collaboration: Univ. of Sheffield, Univ. of Edinburgh, Occidental College, Univ. of New Mexico Overview.
INTRODUCTION Matter And Measurement Steps in the Scientific Method 1.Observations - quantitative - qualitative 2.Formulating Hypotheses - possible explanation.
Measurement and Significant Figures
TAUP2007, Sendai, 12/09/2007 Vitaly Kudryavtsev 1 Limits on WIMP nuclear recoils from ZEPLIN-II data Vitaly A. Kudryavtsev Department of Physics and Astronomy.
A screening facility for next generation low-background experiments Tom Shutt Laura Cadonati Princeton University.
Annual Modulation Study of Dark Matter Using CsI(Tl) Crystals In KIMS Experiment J.H. Choi (Seoul National University) SUSY2012, Beijing.
Rare B  baryon decays Jana Thayer University of Rochester CLEO Collaboration EPS 2003 July 19, 2003 Motivation Baryon production in B decays Semileptonic.
2004/Dec/12 Low Radioactivity in CANDLES T. Kishimoto Osaka Univ.
Workshop for Underground experiments and astroparticle physics 1 Radon Environment of Underground Experiment and Detection of Radon Lee, Myeong.
Neutron Monitoring Detector in KIMS Jungwon Kwak Seoul National University 2003 October 25 th KPS meeting.
The current status of XMAS S Introduction Current status of prototype detector Next step Summary Cryodet 1 Y.Koshio for XMASS collaboration (Kamioka observatory,
XMASS experiment Current status 10 th ICEPP Symposium in Hakuba 16 Feb 2004 Yohei Ashie ICRR Univ.of Tokyo.
1 Report on analysis of PoGO Beam Test at Spring-8 Tsunefumi Mizuno July 15, 2003 July 21, 2003 revised August 1, 2003 updated.
in Beijing August 18, 2004 Recent status of the XMASS project Physics goals at XMASS Overview of XMASS Current status of R&D Summary.
IceCube Galactic Halo Analysis Carsten Rott Jan-Patrick Huelss CCAPP Mini Workshop Columbus OH August 6, m 2450 m August 6, 20091CCAPP DM Miniworkshop.
N 2 O-Measurement Methods Folie 1 Nitrous Oxide/Laughing Gas Molar mass: 44,013 kg/kmol Gas density at 0°C and 1,013 bar: 1,9781 kg/m³ Gas density in relation.
BACKGROUND REJECTION AND SENSITIVITY FOR NEW GENERATION Ge DETECTORS EXPERIMENTS. Héctor Gómez Maluenda University of Zaragoza (SPAIN)
Unit 1 How do we distinguish substances?
WIMP search Result from KIMS experiments Kim Seung Cheon (DMRC,SNU)
Chapters 17/23 Classification of Matter. Pure Substance One substance and only one substance is in the material. A pure substance can be an element or.
XMASS experiment Ultra-low BG, multi-purpose detector 3kg fiducial volume (FV) prototype detector 1ton (100kg FV) detector for DM Search S. Moriyama for.
A screening facility for next generation low-background experiments Tom Shutt Case Western Reserve University.
Current status of XMASS experiment 11 th International Workshop on Low Temperature Detectors (LTD-11) Takeda Hall, University of Tokyo, JAPAN 8/1, 2005.
06/2006I.Larin PrimEx Collaboration meeting  0 analysis.
1 Status and background considerations of XMASS experiment Yeongduk Kim Sejong University for the XMASS collaboration LRT2006 Oct. 3, 2006.
A New Upper Limit for the Tau-Neutrino Magnetic Moment Reinhard Schwienhorst      ee ee
A. Tsirigotis Hellenic Open University N eutrino E xtended S ubmarine T elescope with O ceanographic R esearch Reconstruction, Background Rejection Tools.
CH1120.  Vary with respect to chemical properties but share some physical properties ◦ Low molar masses ◦ Non-metallic ◦ Expand spontaneously to fill.
Scintillating Bubble Chambers for Direct Dark Matter Detection Jeremy Mock On behalf of the UAlbany and Northwestern Groups 1.
IDEA Meeting, , Paris, France New results on the Argon purification Grzegorz Zuzel Max-Planck-Institut für Kernphysik, Heidelberg.
Viktor Veszpremi Purdue University, CDF Collaboration Tev4LHC Workshop, Oct , Fermilab ZH->vvbb results from CDF.
Observation Gamma rays from neutral current quasi-elastic in the T2K experiment Huang Kunxian for half of T2K collaboration Mar. 24, Univ.
Neutrinoless double beta decay (0  ) CdTe Semico nductor Band gap (eV) Electron mobility (cm 2 /V/s) Hole mobility (cm 2 /V/s) Density (g/cm 3.
Chromatography.
Status of ULE-HPGe Experiment for WIMP Search in YangYang
Chemical Ideas 7.6 Chromatography.
Status of 100Mo based DBD experiment
Sr-84 0n EC/b+ decay search with SrCl2 crystal
Mo-92 EC/beta+ search with CaMoO4 crystal at Y2L
Upgrade of LXe gamma-ray detector in MEG experiment
杨勇 上海交通大学 On Behalf of the Collaboration 粒子物理数据分析基础和前沿研讨会,2016/9/13
Status of Neutron flux Analysis in KIMS experiment
Presentation transcript:

Measurement of Kr background in the XMASS experiment ICRR master’s course in physics Keisuke Hieda 1

2 Contents 1.Introduction 2.Measurement of Kr in Xe by GC and APIMS 3.85Kr event search using Flash ADC data

3 1.Introduction

4 Introduction ・ XMASS experiment started on 2010 for direct dark matter search. ・ The detector is installed in Kamioka mine and filled with liquid Xe. ・ Xe originally contains Kr and 85Kr beta decay is serious background in XMASS experiment. ・ Kr concentration in Xe should be below 2ppt to detect dark matter (WIMP) signal. Long life time

Introduction (Kr Removal) ・ we removed Kr from Xe by distillation. Xe boiling point Kr boiling point 165[K] 120[K] ・ The structure and performance of XMASS distillation system - Xe circulates in distillation tower and pure Xe is collected at the bottom. - We had to reduce Kr to 5-order smaller amount by distillation because original Xe includes 0.3 ppm Kr. Xd: Kr in off gas Xw: Kr in pure Xe 5 Kr in liquid Xe Kr in gas Xe distillation tower

6 2.Measurement of Kr in Xe by GC and APIMS

Atmospheric Pressure Ionization Mass Spectrometer 7 measurement of pure He gas measurement of He gas including 200ppt Kr Kr peak area is proportional to Kr concentration.

Gas Chromatography ・ You can temporally separate components in Xe sample by Gas Chromatography because the strength of interaction with material in GC varies from component to component in Xe sample. 8 impurity Sensitivity (ppb) H2 N2N2 CO2 CH4 N2+O2 Kr Kr is observed between 150s and 210s.

The method of Kr measurement ・ Gas Chromatography The sensitivity for Kr measurement is only 1ppb. ・ APIMS Ionization energy of Xe is lower than that of Kr so that Kr is not ionized. Combined measurement system of Gas Chromatography and APIMS enables you to measure Kr with much higher sensitivity. ① Firstly Xe sample is introduced to Gas Chromatography and Kr is separated from Xe. ② Only separated Kr is carried to APIMS and measured by APIMS. Time region where sample gas is carried to APIMS 9 Kr

Measurement of Kr in Xe 1.pure He gas ( background measurement ) 2.Kr calibration gas measurement 3.Xe sample measurement gas-phase Xeliquid-phase Xe Kr peak is observed in Xe sample. Kr peak is “not” observed in Xe sample. 10 APIMS

Calculation of Kr in Xe ・ liquid-phase Xe Xe sample measurement is comparable with background measurement. Kr in Xe sample is below APIMS’s sensitivity for Kr. 90%C.L. mean 11

Result ・ Kr in liquid-phase Xe is almost consistent with our goal (2ppt). ・ Kr in gas-phase Xe is about one-order bigger than Kr in liquid-phase Xe. Temperature of XMASS detector is kept around Xe boiling point ( about 170K) so that Kr easily evaporates because Kr boiling point (120K) is lower than Xe boiling point. 12 dateSample pointKr in calibration gas [ppb]Kr in Xe [ppt] 2011/08/27liquid phase0.23±0.05< 2.3 (90%C.L.) 2011/09/02liquid phase0.23±0.05< 3.7 (90%C.L.) 2011/11/15gas phase0.16±0.0577± /11/22gas phase0.16±0.0555± /01/24liquid phase0.07±0.02< 1.2 (90%C.L.) 2012/01/26liquid phase0.07±0.02< 4.2 (90%C.L.)

Kr event search using Flash ADC data

Flash ADC ・ XMASS uses 642 PMTs. The sum of signal from 10 or 11 PMTs is input into each Flash ADC channel. ( Flash ADC has 64 channels.) ・ The figure below shows an example of FADC waveform. Y-axis is ADC count obtained by transforming voltage into digital signal. X-axis is time[ns]. 8ch/board ・ If you integrate this waveform, you can obtain event’s energy. ・ The live time of FADC data for this analysis is days. 14

85Kr event search cut criteriaefficiency β-like peak energy < 260keV100% α event cut95% 440keV < γ-like peak energy < 580keV76% time difference between β-like peak and γ-like peak(dT) > 300ns75% Total efficiency : 54% 15 β γ life time

background event ・ If two independent events whose energies are comparable with 85Kr β and γ accidentally happen in short time, This event can be background. ・ I applied the following cut to all peaks in FADC dataset to estimate the number of background events. (background events) =1.08[Hz]×0.17[Hz]×3700[ns]×86400[s/day]×55.96[day] = 3.4event ・ Considering statistic and systematic error in the same way as 85Kr event candidate, I obtained the number below as background event. 16 criteriaevent rate [Hz] β-like peak energy < 260 kev && non-α event keV<γ-like peak energy < 580 kev && non-α event0.17 FADC time window

Result ・ I subtracted background event from 85Kr event candidate and considered the remaining events as 85Kr events. ・ I calculated the upper limit of Kr in Xe at 90%C.L. (85Kr event candidate) – (background event) = event < 14.4event (90%C.L.) 26.6event (90%C.L.) Efficiency:54% XMASS uses 830kg Xe. Assuming that Kr in Xe is 2ppt, the number of observed 85Kr event (for 55.96days) should be (2.8±0.9) events. ・ This result is consistent with the result of the other Kr measurement ・ This upper limit is one-order higher than the other one, so I need much more statistics and reduction of systematic error. 17

Conclusion & Summary ・ XMASS experiment works on direct dark matter search using liquid Xe. ・ Xe originally includes Kr and 85Kr beta decay is serious background in direct dark matter search. ・ We removed Kr from Xe by distillation. ・ I measured Kr in Xe with combined measurement system of GC and APIMS and found Kr is reduced to about 2ppt as we expected. ・ I searched for 85Kr decay based on β and γ coincidence event in FADC data and showed the upper limit of Kr in Xe is 28.0 ppt (90%C.L.). This result is consistent with Kr measurement by APIMS and GC. 18