1 Multi-use Facility. 2 Occupancy – 140 persons Building Characteristics Single story 20,000 square feet (250’ x 80’) Standard construction.

Slides:



Advertisements
Similar presentations
HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman
Advertisements

Energy-Efficient Process Cooling
Improve Facility Operation through Commissioning-A Case Study Mingsheng Liu, Ph.D., P. E. University of Nebraska.
The value in mechanical & electrical retrofits What Pays and what Doesnt? What Pays and what Doesnt? June 16, 2011 June 16, 2011 Mark Kesseler Mark Kesseler.
Lindbergh Field International Airport New Terminal Bill Mahoney LSW Engineers.
CON 4003 Construction Estimating Prof R. V. Locurcio.
Environmental Controls I/IG Lecture 14 Mechanical System Space Requirements Mechanical System Exchange Loops HVAC Systems Lecture 14 Mechanical System.
Heating, Ventilation and Conditioning (HVAC) for Hospitals 1 Presentation for: Presented by Leach Wallace Associates September 8, 2011.
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Learning Outcomes Upon completion of this training one should be able to: Identify open loop and closed loop campus-type hydronic water system applications.
University of Iowa Indoor Practice Facility Outside-the-box HVAC Lincoln Pearce, PE – KJWW Engineering David Hahn – University of Iowa Chilled Water Plant.
Upon completion of this training one should be able to: Identify different types of hydronic heating systems Identify key components in a simple hydronic.
© Belimo University 2011, All Rights Reserved
Jim Chmielewski – HVAC Sales Manager Emerson Control Techniques
CHW Optimization Case Studies
UTSW Thermal Energy Plants, Power Generation and Electrical System What do we do to meet the Emission Reduction, Energy usage Reduction and Electrical.
Energy Valve Delta T Manager
Sean Kalman – Hays Fluid Controls
Demystifying SelfSensing Pumps. Design Operating Point 300 Gallons Per Minute 53 Feet of Head System Curves 150 ton 12deg Delta T 60 GPM each.
Piping Systems.
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
CNN Center John Hester Turner Properties, Inc.. CNN Center Built in ,583,000 square feet on 18 floors Five structures joined by a common atrium.
Chilled Water Systems Total Cost of Ownership
Grundfos FLOW THINKING Air conditioning the Grundfos Way.
Lecture Objectives: Finish with thermal storage systems Plumbing Hydronic distribution systems –Chiller/Boiler – Storage – Building.
Green Building Demonstration Project Adam Saling City of San Diego.
Technology and Engineering Development (TED) Building Thomas Jefferson National Accelerator Facility Newport News, VA David Blum | Mechanical Option Dustin.
Chilled water Meyrin consolidation Study 1 st Part Many thanks for their contribution to: Pasquale Alemanno, Fortunato Candito, Alexander Putzu.
Lawrence Livermore National Laboratory Building 111 Mike Holda Lawrence Berkeley National Laboratory (510) or (209) ,
1 Medical Office Building. 2 Occupancy – 400 persons 8 a.m. – 5 p.m. Monday - Friday Building Characteristics Three stories 40,000 square feet (200’ x.
Lecture Objectives: Finish with thermal storage systems Learn about plumbing systems.
1 Upon completion of this training one should be able to: Identify different types of hydronic heating systems Identify key components in a simple hydronic.
City of Hope Amini Medical Center Christopher Bratz Pennsylvania State University Architectural Engineering Mechanical Option Faculty Advisor: Dr. Jelena.
November 2004 Low Hanging Fruit Low Cost Energy Efficiency Opportunities in Cleanrooms.
Objectives - Finish with pumps and plumbing example - Learn about district cooling and heating systems.
Lecture Objectives: Finish boilers and furnaces Start with thermal storage systems.
MECHANICAL ENGINEERING FOR SYSTEM BALANCE ASHRAE MEETING 2/15/2007 NORTHERN NEVADA CHAPTER 126 MATT BRENNAN, TBE.
Architectural Engineering Senior Thesis Mechanical System Redesign Saint Joseph Medical Center Chris Nicolais.
Sizing Variable Flow Piping – An Opportunity for Reducing Energy
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
1 Pumping System Fundamentals 2014 Jeff Turner Systecore Inc.
Learning Outcomes Upon completion of this training one should be able to: Identify the influence of codes on pump & hydronic design Understand HVAC loads.
1 Variable Speed Pumping in Hydronic Systems Why use VFD or VSD Pumps? What are they and how do they work Back to the basics – reading constant speed curves.
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
1 Hospital Building and Campus Piping. 2 Hospital Building Occupancy – office and patient areas Patient areas: 24 hours per day Office areas: 8 am – 5.
Geothermal. Defining “Geothermal” Energy Dictionary definition – Relating to the internal heat of the earth The Earth acts as a giant solar collector,
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Lecture Objectives: Answer question related to Project 1 Finish with thermal storage systems Learn about plumbing systems.
Lecture Objectives: Learn about Pumps and System Curves.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
Lecture Objectives: Plumbing Pumps Hydronic distribution systems
ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 10 : CONTROL VALVES IN CLOSED LOOP SYSTEMS.
Hilario J. Negrón (787) ext 3223 (787) Measuring Operational Efficiency.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Course Exam Next Thursday (April 15) 7 pm Same classroom (ECJ 7.208) 2.5-hour exam Open book open notes All problem types of questions (short but comprehensive)
Michael Reilly, Jr. – Mechanical Option Advisor – James Freihaut, PhD & Dustin Eplee The Pennsylvania State University Nassau Community College Life Sciences.
WELCOME. Glycol Refrigeration A most basic definition of refrigeration is taking heat from someplace we don’t want it and moving it to someplace where.
Rack Refrigeration Systems ©2015 Master-Bilt Products, an unincorporated division of Standex International Corporation. All rights reserved.
WSHP Systems 1.
Chapter 14 Heating, Ventilation & Air conditioning (hvac)
Lecture Objectives: Learn about thermal storage systems

ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Energy Efficiency in District Coiling System
Objectives Finish duct systems Learn about plumbing systems
INNOVATION lab MEP MECHANICAL/ELECTRICAL/PLUMBING :
Lecture Objectives: Learn about Pumps and System Curves.
System Curve Example Design Condition 20 ft.w.c. required each way to deliver design flow to and from the headers at the loads Distribution Pump Bell.
‘‘ BUILDING AUTOMATION’’
Presented by Mike Zacharias
Presentation transcript:

1 Multi-use Facility

2 Occupancy – 140 persons Building Characteristics Single story 20,000 square feet (250’ x 80’) Standard construction

3 What we will cover: Types of hydronic heating systems Closed loop perimeter heating Closed loop radiant systems Water source heat pumps Ground source heat pumps Piping methods Constant speed/constant volume Constant speed/variable volume Variable speed/variable volume Retrofit market Significant opportunities! Magna3 advantages

4 HW Closed Loop Perimeter/ Fan Coil System Optional Variable Speed Components ∆P Sensor Modulating Control Valve (typ.) Secondary Pump Common Pipe 2-way or Two Position Valve (typ.) Boiler Primary Pumps Expansion Tank Air Separator Balance Valve (typ.) Boiler Load (typ.)

Manual balance valve 3-way control valve 2-way control valve Air separator System piping components

6 Fan coil VAV box

7 HW Closed Loop Radiant Floor/Snow Melt System Radiant Floor or Snow Melt Panels Boiler #2Boiler #1 P1 P2 Secondary Pump Mixing Valve Primary Pumps P1 & P2* Redundant* Expansion Tank Air Separator Common Pipe

8 HW Closed Loop Radiant Floor/Snow Melt System

9

10 Heat Pumps 60ºF HPWS 53ºF HPWR Heat Pump 160ºF HHWR 180ºF HHWS 53ºF CHWR Fan Coil Unit 45ºF CHWS Air 60ºF HPWS 67ºF HPWR 60ºF HPWR 60ºF HPWS Heat Pump Cooling Heating

Heat Pump Operation 11 53ºF HPWR Fan Air 60ºF HPWS Heating Water to Refrigerant Heat Exchanger Compressor Reversing Valve Refrigerant Coil Expansion Valve Refrigerant Piping

12 Heat Pumps Types Water source Boiler and chiller Ground source Bore field / pond loop / well Hybrid A ground source plus supplemental heating or cooling

Closed Circuit Cooling Tower WSHP Buffer Tank ( Optional )) Compression Tank 13 Water Source Heat Pump (WSHP) Boiler WSHP Make-up Water Primary Pumps P1 & P2* Redundant* Expansion Tank Air Separator

14 WSHP Components Cooling Towers Boilers

15 Ground Source Heat Pump (GSHP) Bore Field GSHP Buffer Tank ( Optional ) Compression Tank GSHP Make-up Water HP Loop Pumps P1 & P2* Redundant* Expansion Tank Air Separator Bore Field Loop Pump

16 GSHP

17 Hybrid Ground Source Heat Pump Bore Field GSHP Buffer Tank ( Optional ) Compression Tank GSHP Make-up Water HP Loop Pumps P1 & P2* Redundant* Expansion Tank Air Separator Bore Field Loop Pump

18 Hydronic Piping Systems Types: Constant Speed/Constant Volume (CS/CV) Piping & equipment requirements Deficiencies Energy usage Constant Speed/Variable Volume (CS/VV) Piping & equipment requirements Advantages Energy usage Variable Speed/Variable Volume (VS/VV) Piping & equipment requirements Advantages Energy usage

19 CS/CV Piping System 3-way Valve Load Balance Valve (Typ.) Expansion Tank Air Separator Boiler 2* Boiler 1 Primary Pumps P1 & P2* * Redundant

20 CS/CV System Deficiencies High return water temperatures Robs hot water from other coils at part loaded conditions Increases flow Adds additional boilers on line Boiler performance is reduced

21 CS/CV System Load for Multi-use Facility: Chicago, IL Plot load profile Select pump for ft

Flow (gpm) Head (ft) ft CS/CV Pump 97%

23 Pump Energy Consumption - CS/CV CS/CV

24 CS/VV HW Piping Systems Primary Pumps P1 & P2* *Redundant Return Supply Secondary Pumps P1 & P2* Boiler 1 Boiler 2* Expansion Tank Air Separator

25 CS/VV Pumping Systems Add secondary pumps Add common pipe Add system bypass Add 2-way valves Eliminate 3-way valves…or

26 CS/VV Pumping Systems Eliminate 3-way valves Disable 3-way valves Shut bypass valve Disconnect bypass pipe Actuator may be undersized for 2-way operation Does this make $ense?

Flow (gpm) Head (ft) ft CS/VV Pump Curve 97%

28 CS/VV Advantages Lower return water temperatures Minimizes flow to coils Decreases secondary flow Reduces boilers on line Boiler performance is increased Ease of system operation Energy savings Preferred piping method

29 Pump Energy Consumption - CS/VV CS/CV CS/VV

30 VS/VV Pumping Add: Variable frequency drive (VFD) Programmable logic controller (PLC) Differential pressure sensors (∆P) Direct digital controls (DDC) Save 75% AOC versus CS/CV!

31 VS/VV Hot Water Systems Secondary Pumps VSP1 & VSP2* ΔP Sensor Air Separator Expansion Tank *Redundant Return Supply Boiler 1 Boiler 2* VS Pumps And Controls

32 Pump Curve Summary CS/CV ft CS/VV VS/VV ft ft 54 9 ft

ft Flow (gpm) Head (ft) VS/VV Pump Curve Magna

34 VS/VV Advantages Optimizes return water temperatures Optimizes flow to coils Decreases secondary flow Reduces boilers on line Boiler performance is increased Ease of system operation Optimum energy savings

35 Pump Energy Consumption - VS/VV CS/CV CS/VV VS/VV

36 VS/VV Advantages Cost effective design Primary-secondary pumping Common pipe design 2-way valve operation Save 75% of pumping energy over CS/CV systems Save 50% of pumping energy over CS/VV systems

37 Additional System Savings Additional sources of energy savings Boiler operation ΔT optimization Sources of first cost savings Pump sizing Boiler sizing Valve sizing Pipe sizing

38 VS/VV Pumping Add: Variable frequency drive (VFD) Programmable logic controller (PLC) Differential pressure sensors (∆P) Direct digital controls (DDC) Or add…

39 Demand More Magna3!

40 HW Systems w/ Magna3 Secondary Pumps VSP1 & VSP2 Primary Pumps MP1 & MP2* *Redundant Return Supply Boiler 1 Boiler 2* Expansion Tank Air Separator Magna3 VS Pumps With Controls

41 VS/VV Retrofit Opportunities Converting CS/CV to VS/VV Steam systems 3 pipe hot/chilled water systems One pipe hot water systems 3-way valve hot water systems Uncontrolled radiant systems Over-sized boiler pumps

42 VS/VV Retrofit Opportunities Converting CS/VV to VS/VV CS 2-way valve HW systems CS three pipe systems Systems with poor ΔT control Systems with over-sized pumps Systems with local ΔP sensors Systems with single VS pumps

43 Demand More Magna3: Features & Benefits