X-Ray Photoelectron Spectroscopy (XPS)

Slides:



Advertisements
Similar presentations
Auger Electron Spectroscopy
Advertisements

X-ray Photoelectron Spectroscopy
Ion beam Analysis Joele Mira from UWC and iThemba LABS Tinyiko Maluleke from US Supervisor: Dr. Alexander Kobzev Dr. Alexander Kobzev.
PES photoelectron spectroscopy. How does PES work? PES works on the same principle as the photoelectric effect.
Interactions of Radiation With Matter
Saeedeh Ghaffari Nanofabrication Fall 2011 April 15 1.
Photoelectron Spectroscopy Straightforward evidence for the validity of orbital diagram Konsler 2013.
AMCF Materials Characterization School 2012 X-Ray Photoelectron Spectroscopy Tim Morgan.
Module 2: Analytical methods and separation techniques.
Photoelectron Spectroscopy
First of all, do you know any methods to check chemical composition? Or how you know what is what? First of all, do you know any methods to check chemical.
AUGER ELECTRON SPECROSCOPY. Auger Electron Spectroscopy (AES) was developed in the late 1960's deriving its name from the effect first observed by Pierre.
Catalysis and Catalysts - XPS X-Ray Electron Spectroscopy (XPS)  Applications: –catalyst composition –chemical nature of active phase –dispersion of active.
Methods and Tehniques in Surface Science Prof. Dumitru LUCA “Alexandru Ion Cuza” University, Iasi, Romania.
Lecture 18. Chemical: XPS.
Emre Ertuğrul Emin Şahin Seçkin Gökçe KMU 396 Material Science and Technology.
X-Ray Photoelectron Spectroscopy (XPS)
X-Ray Photoelectron Spectroscopy (XPS)
Atomic Absorption Spectroscopy (AAS)
X-Ray Photoelectron Spectroscopy of Interfaces
Rutherford Backscattering Spectrometry
Spectroscopy for AP Chemistry
Qualitative, quantitative analysis and “standardless” analysis NON DESTRUCTIVE CHEMICAL ANALYSIS Notes by: Dr Ivan Gržetić, professor University of Belgrade.
X-ray Photoelectron Spectroscopy —— Application in Phase-switching Device Study Xinyuan Wang A
Thin Film Deposition Prof. Dr. Ir. Djoko Hartanto MSc
Radiology is concerned with the application of radiation to the human body for diagnostically and therapeutically purposes. This requires an understanding.
Mass Spectrometer Mass spectrometere is a very powerful method to analyse the structure of organic compounds.
Electron Microscope Sarah, David, Jóhann.
Spectroscopy for AP Chemistry Photoelectron Spectroscopy (PES) Provides data for ionization energy trends and applications Mass Spectrometry Provides atomic/molar.
Stopping Power The linear stopping power S for charged particles in a given absorber is simply defined as the differential energy loss for that particle.
NUCLEAR PHYSICS & RADIOACTIVITY PHYSICS - UNIT ONE.
Photoemission Fundamentals of Data Acquisition and Analysis J. A. Kelber, June Texts: PHI handbook, Briggs and Seah Outline: I.Photoemission process.
Physical and Chemical Tests 10-1 Purification: Chromatography Distillation Recrystallization Comparison to known compounds: Melting point Boiling point.
IB Chemistry ATOMIC THEORY
Auger Electron Spectroscopy (AES) 1. Brief History Auger Effect discovered in 1920’s Meitner published first journal Auger transitions considered noise.
X-RAY PHOTOELECTRON SPECTROSCOPY (XPS)
III. Analytical Aspects Photoelectron Spectroscopy Cheetham & Day, Chapter 3 Surface Technique: cannot provide completely reliable analysis for bulk samples.
Methods in Surface Physics Experimentation in Ultra-High Vacuum Environments Hasan Khan (University of Rochester), Dr. Meng-Fan Luo (National Central University)
Electron Microscopes Used to count individual atoms What can electron microscopes tell us? Morphology – Size and shape Topography – Surface features (roughness,
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/28/2006Chapter 6Electron Spectroscopy Chapter 6 Electron.
Scanning Electron Microscope (SEM)
K.Azadkish H. Asadi M.N.Amiri S.Amininasab E.Bahjati H.Hamidi A.R.Jafari M.J.Hosseinishahi Dastjerdi * X-ray Photoelectron Spectroscopy Instrumental &
Chapter 32 Radiochemical Methods. Introduction… Radiochemical methods tend to be labor intensive and generate liquid waste due to the chemical separations.
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
Reminders for this week Homework #4 Due Wednesday (5/20) Lithography Lab Due Thursday (5/21) Quiz #3 on Thursday (5/21) – In Classroom –Covers Lithography,
Chapter 25 Nuclear Chemistry 25.1 Nuclear Radiation
Scanning capacitance microscopy
AUGER ELECTRON SPECTROSCOPY
SCC Science Dept F W Aston SCC Science Dept Aston’s Mass Spectrometer.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Nuclear Chemistry. Radioactivity The process by which materials give off such rays radioactivity; the rays and particles emitted by a radioactive source.
Electron Spectroscopy for Surface Analysis 1. Outline Introduction XPS Background XPS Instrument How Does XPS Technology Work? Auger Electron Cylindrical.
THE MASS SPECTROMETER describes how a mass spectrum is produced using a mass spectrometer.
History of Atomic Theory Figuring Out Atoms. Dalton’s Atomic Theory 1.Matter is composed of extremely small particles called atoms. 2.Atoms are indivisible.
Lecture 5: Secondary ion mass spectroscopy (SIMS) Assoc. Prof. Dr. Zainovia Lockman, PPKBSM, USM EBB 245. Materials Characterisation.
Periodic Properties of Elements
1© Manhattan Press (H.K.) Ltd Continuous spectra Spectra Sun’s spectrum and Fraunhofer lines.
 Matter is any thing that occupies space & has mass  Present in three states: solid, liquid, & gas  It could be divided into elements & compounds 
Auger Electron Spectroscopy. Outline 1.Introduction 2.Principle of AES 3.Instrumentation 3.1 UHV environment 3.2 Electron gun 3.3 Electron energy analyzer.
X-ray photoelectron spectroscopy (XPS)
Presentation on SEM (Scanning of Electron Microscope) Represented by:-Ravi Kumar Roll:- (BT/ME/1601/006)
Auger Electron Spectroscopy (AES)
Electron Microscopy General consideration Notes
What is XPS? XPS (x-ray photoelectron spectroscopy) is also known as ESCA (electron spectroscopy for chemical analysis). XPS provides chemical information.
NANO 230 Micro/NanoFabrication
The Mass Spectrometer.
Photoelectron Spectroscopy
Surface analysis techniques part I
Presentation transcript:

X-Ray Photoelectron Spectroscopy (XPS) David Echevarría Torres University of Texas at El Paso College of Science Chemistry Department

Outline XPS Background XPS Instrument How Does XPS Technology Work? Auger Electron Cylindrical Mirror Analyzer (CMA) Equation KE versus BE Spectrum Background Identification of XPS Peaks X-rays vs. e- Beam XPS Technology

XPS Background XPS technique is based on Einstein’s idea about the photoelectric effect, developed around 1905 The concept of photons was used to describe the ejection of electrons from a surface when photons were impinged upon it During the mid 1960’s Dr. Siegbahn and his research group developed the XPS technique. In 1981, Dr. Siegbahn was awarded the Nobel Prize in Physics for the development of the XPS technique

X-Rays Irradiate the sample surface, hitting the core electrons (e-) of the atoms. The X-Rays penetrate the sample to a depth on the order of a micrometer. Useful e- signal is obtained only from a depth of around 10 to 100 Å on the surface. The X-Ray source produces photons with certain energies: MgK photon with an energy of 1253.6 eV AlK photon with an energy of 1486.6 eV Normally, the sample will be radiated with photons of a single energy (MgK or AlK). This is known as a monoenergetic X-Ray beam.

Why the Core Electrons? An electron near the Fermi level is far from the nucleus, moving in different directions all over the place, and will not carry information about any single atom. Fermi level is the highest energy level occupied by an electron in a neutral solid at absolute 0 temperature. Electron binding energy (BE) is calculated with respect to the Fermi level. The core e-s are local close to the nucleus and have binding energies characteristic of their particular element. The core e-s have a higher probability of matching the energies of AlK and MgK. Core e- Valence e- Atom

Binding Energy (BE) The Binding Energy (BE) is characteristic of the core electrons for each element. The BE is determined by the attraction of the electrons to the nucleus. If an electron with energy x is pulled away from the nucleus, the attraction between the electron and the nucleus decreases and the BE decreases. Eventually, there will be a point when the electron will be free of the nucleus. This is the point with 0 energy of attraction between the electron and the nucleus. At this point the electron is free from the atom. x p+ B.E. These electrons are attracted to the proton with certain binding energy x

Energy Levels Vacumm Level Fermi Level Lowest state of energy BE Ø, which is the work function At absolute 0 Kelvin the electrons fill from the lowest energy states up. When the electrons occupy up to this level the neutral solid is in its “ground state.”

XPS Instrument XPS is also known as ESCA (Electron Spectroscopy for Chemical Analysis). The technique is widely used because it is very simple to use and the data is easily analyzed. XPS works by irradiating atoms of a surface of any solid material with X-Ray photons, causing the ejection of electrons. University of Texas at El Paso, Physics Department Front view of the Phi 560 XPS/AES/SIMS UHV System

University of Texas at El Paso, Physics Department XPS Instrument The XPS is controlled by using a computer system. The computer system will control the X-Ray type and prepare the instrument for analysis. University of Texas at El Paso, Physics Department Front view of the Phi 560 XPS/AES/SIMS UHV System and the computer system that controls the XPS.

XPS Instrument The instrument uses different pump systems to reach the goal of an Ultra High Vacuum (UHV) environment. The Ultra High Vacuum environment will prevent contamination of the surface and aid an accurate analysis of the sample. University of Texas at El Paso, Physics Department Side view of the Phi 560 XPS/AES/SIMS UHV System

XPS Instrument X-Ray Source Ion Source SIMS Analyzer Sample introduction Chamber

Sample Introduction Chamber The sample will be introduced through a chamber that is in contact with the outside environment It will be closed and pumped to low vacuum. After the first chamber is at low vacuum the sample will be introduced into the second chamber in which a UHV environment exists. First Chamber Second Chamber UHV

Diagram of the Side View of XPS System X-Ray source Ion source Axial Electron Gun Detector CMA sample SIMS Analyzer Sample introduction Chamber Sample Holder Ion Pump Roughing Pump Slits

How Does XPS Technology Work? A monoenergetic x-ray beam emits photoelectrons from the from the surface of the sample. The X-Rays either of two energies: Al Ka (1486.6eV) Mg Ka (1253.6 eV) The x-ray photons The penetration about a micrometer of the sample The XPS spectrum contains information only about the top 10 - 100 Ǻ of the sample. Ultrahigh vacuum environment to eliminate excessive surface contamination. Cylindrical Mirror Analyzer (CMA) measures the KE of emitted e-s. The spectrum plotted by the computer from the analyzer signal. The binding energies can be determined from the peak positions and the elements present in the sample identified.

Why Does XPS Need UHV? Contamination of surface XPS is a surface sensitive technique. Contaminates will produce an XPS signal and lead to incorrect analysis of the surface of composition. The pressure of the vacuum system is < 10-9 Torr Removing contamination To remove the contamination the sample surface is bombarded with argon ions (Ar+ = 3KeV). heat and oxygen can be used to remove hydrocarbons The XPS technique could cause damage to the surface, but it is negligible.

The Atom and the X-Ray X-Ray Free electron Valence electrons proton neutron electron electron vacancy Core electrons The core electrons respond very well to the X-Ray energy

X-Rays on the Surface Atoms layers e- top layer e- lower layer with collisions but no collisions X-Rays Outer surface Inner surface

X-Rays on the Surface The X-Rays will penetrate to the core e- of the atoms in the sample. Some e-s are going to be released without any problem giving the Kinetic Energies (KE) characteristic of their elements. Other e-s will come from inner layers and collide with other e-s of upper layers These e- will be lower in lower energy. They will contribute to the noise signal of the spectrum.

X-Rays and the Electrons Electron without collision X-Ray Electron with collision The noise signal comes from the electrons that collide with other electrons of different layers. The collisions cause a decrease in energy of the electron and it no longer will contribute to the characteristic energy of the element.

What e-s can the Cylindrical Mirror Analyzer Detect? The CMA not only can detect electrons from the irradiation of X-Rays, it can also detect electrons from irradiation by the e- gun. The e- gun it is located inside the CMA while the X-Ray source is located on top of the instrument. The only electrons normally used in a spectrum from irradiation by the e- gun are known as Auger e-s. Auger electrons are also produced by X-ray irradiation.

X-Rays and Auger Electrons When the core electron leaves a vacancy an electron of higher energy will move down to occupy the vacancy while releasing energy by: photons Auger electrons Each Auger electron carries a characteristic energy that can be measured.

Two Ways to Produce Auger Electrons The X-Ray source can irradiate and remove the e- from the core level causing the e- to leave the atom A higher level e- will occupy the vacancy. The energy released is given to a third higher level e-. This is the Auger electron that leaves the atom. The axial e- gun can irradiate and remove the core e- by collision. Once the core vacancy is created, the Auger electron process occurs the same way.

Auger Electron 2 3 4 1 Free e- e- released to analyze e- Vacancy e- of high energy that will occupy the vacancy of the core level Free e- 3 e- released to analyze 4 1 e- gun e- Vacancy 1, 2, 3 and 4 are the order of steps in which the e-s will move in the atom when hit by the e- gun.

Auger Electron Spectroscopy (AES) e- released from the top layer Outer surface Inner surface Electron beam from the e- gun Atom layers

Cylindrical Mirror Analyzer (CMA) The electrons ejected will pass through a device called a CMA. The CMA has two concentric metal cylinders at different voltages. One of the metal cylinders will have a positive voltage and the other will have a 0 voltage. This will create an electric field between the two cylinders. The voltages on the CMA for XPS and Auger e-s are different.

Cylindrical Mirror Analyzer (CMA) When the e-s pass through the metal cylinders, they will collide with one of the cylinders or they will just pass through. If the e-’s velocity is too high it will collide with the outer cylinder If is going too slow then will collide with the inner cylinder. Only the e- with the right velocity will go through the cylinders to reach the detector. With a change in cylinder voltage the acceptable kinetic energy will change and then you can count how many e-s have that KE to reach the detector.

Cylindrical Mirror Analyzer (CMA) 0 V +V X-Rays Source Sample Holder Electron Pathway through the CMA Slit Detector

Equation KE=hv-BE-Ø KE Kinetic Energy (measure in the XPS spectrometer) hv photon energy from the X-Ray source (controlled) Ø spectrometer work function. It is a few eV, it gets more complicated because the materials in the instrument will affect it. Found by calibration. BE is the unknown variable

Equation KE=hv-BE-Ø The equation will calculate the energy needed to get an e- out from the surface of the solid. Knowing KE, hv and Ø the BE can be calculated.

KE versus BE KE can be plotted depending on BE Each peak represents the amount of e-s at a certain energy that is characteristic of some element. Binding energy # of electrons (eV) BE increase from right to left 1000 eV 0 eV E KE increase from left to right

Interpreting XPS Spectrum: Background The X-Ray will hit the e-s in the bulk (inner e- layers) of the sample e- will collide with other e- from top layers, decreasing its energy to contribute to the noise, at lower kinetic energy than the peak . The background noise increases with BE because the SUM of all noise is taken from the beginning of the analysis. Binding energy # of electrons N1 N2 N3 N4 Ntot= N1 + N2 + N3 + N4 N = noise

XPS Spectrum The XPS peaks are sharp. In a XPS graph it is possible to see Auger electron peaks. The Auger peaks are usually wider peaks in a XPS spectrum. Aluminum foil is used as an example on the next slide.

XPS Spectrum O 1s O Auger O because of Mg source C O 2s Al Al Sample and graphic provided by William Durrer, Ph.D. Department of Physics at the Univertsity of Texas at El Paso

Auger Spectrum Characteristic of Auger graphs The graph goes up as KE increases. Sample and graphic provided by William Durrer, Ph.D. Department of Physics at the Univertsity of Texas at El Paso

Identification of XPS Peaks The plot has characteristic peaks for each element found in the surface of the sample. There are tables with the KE and BE already assigned to each element. After the spectrum is plotted you can look for the designated value of the peak energy from the graph and find the element present on the surface.

X-rays vs. e- Beam X-Rays Electron Beam Hit all sample area simultaneously permitting data acquisition that will give an idea of the average composition of the whole surface. Electron Beam It can be focused on a particular area of the sample to determine the composition of selected areas of the sample surface.

XPS Technology Consider as non-destructive because it produces soft x-rays to induce photoelectron emission from the sample surface Provide information about surface layers or thin film structures Applications in the industry: Polymer surface Catalyst Corrosion Adhesion Semiconductors Dielectric materials Electronics packaging Magnetic media Thin film coatings

References Dr.William Durrer for explanations on XPS technique, Department of Physics at UTEP. www.uksaf.com www.casaxps.com www.nwsl.net XPS instrument from the Physics Department.

Acknowledgements Elizabeth Gardner, Ph.D. from the Department of Chemistry at the University of Texas at El Paso William Durrer, Ph.D. from the Department of Physics at the University of Texas at El Paso Roberto De La Torre Roche Lynn Marie Santiago