Legacy Remote I/O Upgrade to Ethernet

Slides:



Advertisements
Similar presentations
Legacy Hardware and Software Upgrade Overview
Advertisements

● Hardware Upgrade Overview20 minutes ● Legacy Application Import Tool60 minutes ● Add Quantum Ethernet DIO drops 45 minutes ● Add new X80 Ethernet DIO.
Niobrara R&D Corp Compact PLC Upgrades With the CERI.
Spyder Re-flash 2.0 How-To
Introduction to the Enhanced AIM When Q.i was first introduced, a ladder logic driver program – called the Application Interface Module (AIM) - was created.
Unit Test Calibration Training
Spyder Re-flash How-To
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment Chapter 2: Managing Hardware Devices.
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment Chapter 2: Managing Hardware Devices.
1 Proctor Caching and TestNav Configuration. Role-Based Key 2 Role-Based Codes LEA Test Coordinator – School Test Coordinator – Test Administrator/Proctor.
Copyright © 2002 Delmar Thomson Learning Chapter 9 Putting Together a Modular PLC.
Control Activity & Industry Services
Virtual Machine Management
● Hardware Upgrade Overview20 minutes ● Legacy Application Import Tool60 minutes ● Add Quantum Ethernet DIO drops 45 minutes ● Add new X80 Ethernet DIO.
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
System Resources INFO1119 (Fall 2012).
Part 1 Using the ARM board And start working with C Tutorial 5 and 6
This presentation will guide you though the initial stages of installation, through to producing your first report Click your mouse to advance the presentation.
One to One instructions Installing and configuring samba on Ubuntu Linux to enable Linux to share files and documents with Windows XP.
Packet Tracer: Novice Session
Packet Tracer 4.1: Novice Session
Configuring the MagicInfo Pro Display
Hands-On Microsoft Windows Server 2008
MagicInfo Pro Server Software All control, content, and scheduling is performed within the MagicInfo Pro Server software previously installed. Before.
Module 13: Configuring Availability of Network Resources and Content.
ActEyes IP Cam Training Part 1: Camera Setup. Network Setup Overview Each IP Cam on the network will need its own IP address to be assigned. This address.
Chapter 7 AC 800M Hardware Course T314.
Module 14: Configuring Print Resources and Printing Pools.
Hands-On Virtual Computing
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment, Enhanced Chapter 2: Managing Hardware Devices.
SLC 500 Ethernet Processor Communications Configuration
1999 Cabletron Systems. Wireless Networking RoamAbout RoamAbout Installation Installation/Configuration of: Network adapter card on a: Windows 95 system.
Home Media Network Hard Drive Training for Update to 2.0 By Erik Collett Revised for Firmware Update.
MagicInfo Pro Scheduler Now that a template has been created from content imported into the Library, the user is ready to begin scheduling content to.
1 Chapter Overview Configuring and Troubleshooting the Display Configuring Power Management Configuring Operating System Settings Configuring and Troubleshooting.
Microsoft FrontPage 2003 Illustrated Complete Finalizing a Web Site.
M340 Modbus Plus Proxy Link legacy systems to Ethernet
1 PanelView ™ 300 Micro & MicroLogix ™ Lab 1. 2 Today you will receive training on the NEW PanelView 300 Micro operator terminal and the NEW version of.
Overview of MSWS Control of 212-LC July 15, 2006.
1 Micro Economix 1500 RSLogix 500 LAB#3 Sequencing and Subroutines.
Date: File:PRO1_04E.1 SIMATIC S7 Siemens AG All rights reserved. Information and Training Center Knowledge for Automation Hardware Configuration.
Managing Hardware Devices Facilitator: Suleiman Mohammed(mcpn, mncs) Institute of Computing & ICT, Ahmadu Bello University, Zaria.
Quick guide to ASIMON configuration For version 3.0 or greater SAFETY AT WORK Date: 3/18/2009.
WHQL Code Coverage Prototype Program Andy Wen. 2 Agenda What is Code Coverage Prototype Program? What is Code Coverage Prototype Program? A prototype.
Programming Software and Setting. Default IP Add : , also can be changed via Programming Software, if forget IP address, Programmer can.
Unity Application Generator Step 4d: Defining PLC.
DPM - IPMI Product Support Engineering VMware Confidential.
Unity Application Generator How Can I… Exchange data between TWIDO PLC and any Unity PLC using UAG.
Unity Application Generator How Can I… Develop a Generic device which can communicate Over IO Scanner.
© 2002, Cisco Systems, Inc. All rights reserved..
How to setup DSS V6 iSCSI Failover with XenServer using Multipath Software Version: DSS ver up55 Presentation updated: February 2011.
Unity Application Generator Step 7a: Generating PLC.
Run the on your PC to start the firmware configuration process Run IP Config Tool.
Technology Coordinator Training. Agenda Getting Started Using SystemCheck Technology Configurations Infrastructure Trial Proctor Caching Overview Managing.
An Overview When Connecting to Yaskawa Drives Date: 8/14/06, Rev: PP.AFD.26.
How do I access the disclosure form? Go to Office of Research Compliance website Click on the eCOI link under Conflict.
Version of the document: 1.01 Software Version CBox: v3.7.1 Hardware Version CBox: C5 Remote Access Configuration Client Language: English.
SCC P2P – Collaboration Made Easy Contract Management training
OCS Configuration Software:
Do-more Technical Training
Unity Application Generator
Bomgar Remote support software
ReadySet Achieve Maximize Training Agenda
Setup Of 4050 EIP To Control LOGIX PLC
Programmable Logic Controllers (PLCs) An Overview.
MicroEconomix 1500 RSLogix 500 LAB#1
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Unity Application Generator
Create, Upload and Use Data Extensions (Lists)
Presentation transcript:

Legacy Remote I/O Upgrade to Ethernet

Upgrading a Legacy LL984 Remote I/O system to Unity Benefits of Ethernet Remote I/O Daisy chain loop for reliability No infrastructure hardware for dependability Increased communications Speed Future forward the system with PlantStruxure products Distributed I/O (up to 128 nodes) on the same network (must use the Connexium Dual ring switches (DRS) ) Remote access to the PLC from the RI/O drops thru the available service port

Upgrading a Legacy LL984 Remote I/O system to Unity Unity version 7.0 has all of the previously mentioned features PLUS: The ability to add an Ethernet RI/O head into the Quantum PLC system while maintaining the Legacy S908 network. M340 (x80 I/O) Remote I/O drops in the Ethernet RI/O network

Legacy Upgrade Agenda Legacy Application Import Tool 60 minutes Hardware Upgrade Overview 20 minutes Legacy Application Import Tool 60 minutes Add Quantum Ethernet DIO drops 45 minutes Add new X80 Ethernet DIO drops 45 minutes LL984 Editor and Unity Overview 60 minutes The flow and topics to be covered today Estimated time to cover the information.

Ethernet Remote I/O What will we discuss: Upgrading Enhancing Monitoring Distributed I/O

Upgrading Remote I/O system Demonstration the steps to Upgrade your PLC Remote I/O system Import Project and Analyze Error Elimination Modify the Unity configuration for QEIO Upgrade the Remote I/O hardware Analyze error elimination of your program Verify process operating in the Unity QEIO environment

Import and Elimination of Analyze errors After Importing the Legacy application into Unity 6.0 or greater, Analyze and correct all errors until you have the application in the Built state. This step is done to get the original Legacy application ready to confirm the process operation on the Unity PLC. Always verify the application operation after Import. Upgrade in a stepped process.

Modify the Unity configuration for QEIO Ethernet RI/O uses DTM (Device Type Manager) technology. The DTM should be installed as part of Unity. But if this is the first time using QEIO you should check to see that it was loaded. This can be done by exposing the Project Browser by either opening an I/O Drop or selecting Tools>> Project Browser. Select the DTM tab at the bottom of the window.

Open Vendors and select Schneider Electric Open Vendors and select Schneider Electric. If it is listed in the devices, the Ethernet RI/O head can be configured in the local Quantum drop (1).

If it is not in listed in the Device list, you will need to update the DTM catalog. Select “External Update Tool” 2) Select the correct device then “Update” and 3) Select “Reload catalog” Note: This is also how you would add a new DTM to the Unity catalog. 1) 3) 2)

Upgrade the Remote I/O hardware Prior to Upgrading the Remote I/O network you need to replace the PLC with a QEIO compatible version. If there are Communication Adapter modules in the system, they may also need to be Upgraded.

After replacing the PLC, don’t forget about the PLC configuration selections “Operating Mode on Cold Start”. These need to be selected if you want the source applications State Ram PLC values moved into Unity State Ram and/or if you want the PLC to power up in the Run state.

Insert the QEIO Head into an empty backplane slot Insert the QEIO Head into an empty backplane slot. Right click and select New Device then the 140 CRP 312 00 Head.

To add a Remote Drop, open the ERIO Bus To add a Remote Drop, open the ERIO Bus. Right click on the empty Drop box and select New Device. Select Quantum drop and the appropriate rack size. If the drop number is not sequential, the address can be a changed in the Topological Address window. Changing it here will update all of the required parameters. For this example the remote drop will be changed to 4. Note: The QEIO address range is 1-31 which differs from legacy RI/O that is 2-32.

Again the drop number will be changed to 4. The drop number can also be manually changed by modifying two default settings. Again the drop number will be changed to 4. 1) Change the Drop number, double click on the number and enter new drop number that matches the CRA 312 rotary switch settings. 2) In the Project Browser, double click on the RI/O drop number, select the Parameter tab and change the address to match the rotary switch settings

Copy the I/O Modules the modules from the legacy S908 drops to the new QEIO. Once all modules have been copied / pasted you can delete the legacy S908 RI/O head from the local drop.

Don’t forget to set your drop number rotary switches to match the drop number in the configuration before applying power to the Remote drop.

Analyze error elimination of your program After adding the Remote I/O drops, an Analyze of the program will produce invalid RIO Drop! ” errors. Ethernet RI/O does not get referenced to the LL984 Segments as the legacy RI/O did. You will need to “Clear” the Read and Write Drop references for all Imported Legacy RI/O drops to eliminate these errors.

Ethernet Remote I/O servicing is handled differently than Legacy Remote I/O. This example is for a traditional 3 Segment, 3 I/O Drop Segment Scheduler. Legacy Remote I/O servicing: In legacy and Unity PLC’s Ethernet Remote I/0 LL984 servicing in Unity PLC Scan

If the migration has more than one Remote I/O drop then additional IEC Sections can be added between the LL984 Sections to initiate the required drop reads and writes.

Verify process operating in the Unity QEIO environment Once all of the Analyze errors are eliminated perform a “Rebuild All”, and confirm system operation.

Lab Exercise 7 – Quantum Ethernet IO At the completion of this module the participant should be able to: Configure a new CRP head EIO Processor (140 CRP 312 00) Configure a new CRA EIO Adapter (140 CRA 312 00) Successfully “Build” and download the Unity project. Run and Test the newly configured QEIO drop

Legacy Upgrade Agenda Legacy Application Import Tool 60 minutes Hardware Upgrade Overview 20 minutes Legacy Application Import Tool 60 minutes Add Quantum Ethernet DIO drops 45 minutes Add new X80 Ethernet DIO drops 45 minutes LL984 Editor and Unity Overview 60 minutes The flow and topics to be covered today Estimated time to cover the information.

Enhancing Demonstration the steps to Enhance a PLC system Import and Analyze error elimination of your program Modify the Unity configuration for QEIO Always Verify process operating in the Unity S908 environment Do a stepped upgrade

Adding Ethernet IO Head Once the source application is successfully Imported, modified and in the Built state, we will enhance the Unity project. This will be done by adding a QEIO head to backplane slot position 10 and adding one X80 remote drop. This is done by left clicking on an empty backplane slot, select New Device, Communications and select part number 140CRP31200. Note, make sure you select a compatible PLC for this mixed RI/O system.

Modify the Unity configuration for QEIO Now the x80 Remote I/O drop will be added to the new QEIO network. This can be done with a right mouse click, open the enter the drop Select the x80 EIO drop type Select the correct rack P/N for the drop Right click and Open will open the QEIO bus for configuring open the EIO bus Right click on the Drop number box Select New Device

Finally, add the appropriate x80 hardware as a new EIO drop Finally, add the appropriate x80 hardware as a new EIO drop. Analyze the project and correct any errors. Once the Analyze errors are corrected, Rebuild All, download to the PLC and confirm system operation.

Again, don’t forget to set your drop number rotary switches to match the drop number in the configuration before applying power to the Remote drop.

Lab Exercise – X80 Ethernet IO At the completion of this module the participant should be able to: Configure a new CRP head EIO Processor (140 CRP 312 00) Configure a new CRA EIO Adapter (140 CRA 312 00) Successfully “Build” and download the Unity project. Run and Test the newly configured QEIO drop

Monitoring Demonstrate how to Monitor the QEIO Network Unity System Words (%SW) and Bits (%S) Unity Device DDT’s

Unity System Words (%SW) and Bits (%S) STAT monitoring of the QEIO network is not available. Here are two methods that can be implemented to monitor different aspects of the Legacy STAT instruction. Monitor the System Bits (%S) and Words (%SW): Unity provides a vast amount of diagnostics data through the system bits and words. These can be monitored like the original STAT data or they can be moved into the same 4x area of the application. Example: Battery Failed: LL984 STAT word 1, bit 12 = Unity %S68. Drop Address 4 (both), Rack 1 module health: LL984 STAT word 27 = Unity %SW647 Distributed I/O such as Advantys and Momentum can be connected to the same QEIO network with a DRS switch, this switch MUST be used. Attached is a spreadsheet that contains cross referencing, Note: This spreadsheet is not an exhaustive list.

Unity Device DDT’s Use the Unity Device DDT’s for Quantum and M340 QEIO : Unity provides Device DDT’s that can be used to access Remote I/O drop status. These DDT’s are automatically created when the QEIO drop is configured. The DDT name can be found under the Device DDT tab of the QEIO drop The Device DDT for Quantum is T_U_DROP_STD_IN. The Device DDT for M340 is T_M_DROP_EXT_IN.

Distributed I/O Demonstrate how to incorporate DI/O onto the QEIO Network Discuss how the QEIO network can support DI/O (Advantys, Momentum etc.) on the same media

Distributed I/O connected to the QEIO network thru a Connexium DRS switch Distributed I/O such as Advantsys and Momentum can be connected to the same QEIO network with a DRS switch, this switch MUST be used.

Ethernet Remote I/O Quick Start During this presentation we covered: Upgrading a Remote I/O system Enhancing a Remote I/O system Monitoring the PLC and Remote I/O system Distributed I/O on the QEIO network Questions?

Thank You