Geant4 simulation of the attenuation properties of plastic shield for  - radionuclides employed in internal radiotherapy Domenico Lizio 1, Ernesto Amato.

Slides:



Advertisements
Similar presentations
Advanced Neutron Spectrometer (ANS) Geant4 Simulations
Advertisements

Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
The best collimator configuration (material, number of collimators, collimator shape) is determined by minimizing the ratio R, where N ae is the number.
Radiopharmaceutical Production Target Foil Characteristics STOP.
X-radiation. X-rays are part of the electromagnetic spectrum. X-radiation (composed of X-rays) is a form of electromagnetic radiation. X- rays have a.
Medical Imaging X-Rays I.
Geant4-Genova Group Validation of Susanna Guatelli, Alfonso Mantero, Barbara Mascialino, Maria Grazia Pia, Valentina Zampichelli INFN Genova, Italy IEEE.
Charged Particle Radiation
MONTE-CARLO TECHNIQUES APPLIED TO PROTON DOSIMETRY AND RADIATION SAFETY F. Guillaume, G. Rucka, J. Hérault, N. Iborra, P. Chauvel 1 XXXV European Cyclotron.
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods
Bruce Faddegon, UCSF Inder Daftari, UCSF Joseph Perl, SLAC
J. Tinslay 1, B. Faddegon 2, J. Perl 1 and M. Asai 1 (1) Stanford Linear Accelerator Center, Menlo Park, CA, (2) UC San Francisco, San Francisco, CA Verification.
Interactions with Matter
03/07/2015radiation safety - level 51 Radiation safety level 5 Frits Pleiter.
Tissue inhomogeneities in Monte Carlo treatment planning for proton therapy L. Beaulieu 1, M. Bazalova 2,3, C. Furstoss 4, F. Verhaegen 2,5 (1) Centre.
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Radiation Dosimetry Dose Calculations D, LET & H can frequently be obtained reliably by calculations: Alpha & low – Energy Beta Emitters Distributed in.
Validation of the Bremsstrahlung models Susanna Guatelli, Barbara Mascialino, Luciano Pandola, Maria Grazia Pia, Pedro Rodrigues, Andreia Trindade IEEE.
American Association of Physicists in Medicine (AAPM) Task Group on Monte Carlo Validation Sets: Geant4 Related Findings Ioannis Sechopoulos, Ph.D. Assistant.
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Stopping Power The linear stopping power S for charged particles in a given absorber is simply defined as the differential energy loss for that particle.
Workshop on Physics on Nuclei at Extremes, Tokyo Institute of Technology, Institute for Nuclear Research and Nuclear Energy Bulgarian Academy.
Sergey Ananko Saint-Petersburg State University Department of Physics
Radiation Detection and Measurement, JU, First Semester, (Saed Dababneh). 1 Spectrum if all energy is captured in detector. Allows identification.
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
GRAS Validation and GEANT4 Electromagnetic Physics Parameters R. Lindberg, G. Santin; Space Environment and Effects Section, ESTEC.
Summary of Work Zhang Qiwei INFN - CIAE. Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases.
Design of the Photon Collimators for the ILC Positron Helical Undulator Adriana Bungau The University of Manchester Positron Source Meeting, July 2008.
Helsinki, June 28 - July 2, 2004 COSIRES 2004: 7th International Conference on Computer Simulation of Radiation Effects in Solids Monte Carlo simulation.
Precision Analysis of Electron Energy Deposition in Detectors Simulated by Geant4 M. Bati č, S. Granato, G. Hoff, M.G. Pia, G. Weidenspointner 2012 NSS-MIC.
Space Instrumentation. Definition How do we measure these particles? h p+p+ e-e- Device Signal Source.
Department of Physics University of Oslo
The Particlelike Properties of Electromagnetics Radiation Wei-Li Chen 10/27/2014.
1 PHYS 3313 – Section 001 Lecture #10 Monday, Feb. 17, 2014 Dr. Jaehoon Yu Photoelectric Effect Compton Effect Pair production/Pair annihilation Monday,
IEEE NSS 2012 IEEE NSS 2007 Honolulu, HI Best Student Paper (A. Lechner) IEEE TNS April 2009 Same geometry, primary generator and energy deposition scoring.
Susanna Guatelli & Barbara Mascialino G.A.P. Cirrone (INFN LNS), G. Cuttone (INFN LNS), S. Donadio (INFN,Genova), S. Guatelli (INFN Genova), M. Maire (LAPP),
Alpha and Beta Interactions
Evaluation of absorbed fractions for beta- gamma radionuclides in ellipsoidal volumes of soft tissue through Geant4 Ernesto Amato 1, Domenico Lizio 2 and.
© Jimoid.com 2005 Ionising Radiation There are two types of radiation; ionising and non-ionising. Radiation Ionising Non-ionising Indirectly ionising (neutral.
Precision Validation of Geant4 Electromagnetic Physics Geant4 DNA Project Meeting 26 July 2004, CERN Michela.
Medical Image Analysis Interaction of Electromagnetic Radiation with Matter in Medical Imaging Figures come from the textbook: Medical Image Analysis,
Increase in Photon Collection from a YAP:Ce Matrix Coupled to Wave Lenght Shifting Fibres N. Belcari a, A. Del Guerra a, A. Vaiano a, C. Damiani b, G.
Precision analysis of Geant4 condensed transport effects on energy deposition in detectors M. Batič 1,2, G. Hoff 1,3, M. G. Pia 1 1 INFN Sezione di Genova,
Applications of Monte Carlo Code for a Gamma Resonance System Analysis L. Wielopolski, A. Hanson, I. Dioszegi, M. Todosow, Brookhaven National Laboratory,
Chapter 5 Interactions of Ionizing Radiation. Ionization The process by which a neutral atom acquires a positive or a negative charge Directly ionizing.
Accelerator Physics, JU, First Semester, (Saed Dababneh). 1 In the figure: Photoelectric suppressed. Single Compton (effect of crystal dimensions).
1 Cost Room Availability Passive Shielding Detector spheres for accelerators Radiation Detection and Measurement, JU, First Semester, (Saed Dababneh).
G.I. SmirnovMaterials for Collimators and Beam Absorbers, Simulating radiation damage effects in LHC collimators (code development status)
1 Neutron Effective Dose calculation behind Concrete Shielding of Charge Particle Accelerators with Energy up to 100 MeV V. E Aleinikov, L. G. Beskrovnaja,
Validation of the bremssrahlung process IV Workshop on Geant4 physics validation Susanna Guatelli, Luciano Pandola, Maria Grazia Pia, Valentina Zampichelli.
Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases Zhang Qiwei INFN-LNS/CIAE 14th Geant4 Users and Collaboration.
INTERACTIONS OF RADIATION WITH MATTER. twCshttp:// twCs
Radiation Protection and Safety 3/12/ Interactions with Electrons   Energy-loss Mechanisms Electrons and positrons have similar stopping powers.
Interaction of x-ray photons (and gamma ray photons) with matter.
Validation of GEANT4 versus EGSnrc Yann PERROT LPC, CNRS/IN2P3
Course : Inorganic Pharmacy II Course code: PHR 107 Course Teacher : Zara Sheikh Radioactivity and Radiopharmaceuticals.
Study of the cryogenic THGEM-GPM for the readout of scintillation light from liquid argon Xie Wenqing( 谢文庆 ), Fu Yidong( 付逸冬 ), Li Yulan( 李玉兰 ) Department.
1 Transmission Coefficients and Residual Energies of Electrons: PENELOPE Results and Empirical Formulas Tatsuo Tabata and Vadim Moskvin * Osaka Prefecture.
Chapter 2 Radiation Interactions with Matter East China Institute of Technology School of Nuclear Engineering and Technology LIU Yi-Bao Wang Ling.
Radiopharmaceutical Production Cyclotron radionuclide production STOP.
A Study of Reverse MC and Space Charge Effect Simulation with Geant4
Heating and radiological
INTERCOMPARISON P3. Dose distribution of a proton beam
M.I. Abbas - Alexandria University - EGYPT.
X-Radiation.
CEA – Saclay, DRT/LNHB/LMD, Gif-sur-Yvette, France
Arghya Chattaraj, T. Palani Selvam, D. Datta
Resident Physics Lectures (Year 1)
CRaTER Science Requirements
Resident Physics Lectures (Year 1)
Presentation transcript:

Geant4 simulation of the attenuation properties of plastic shield for  - radionuclides employed in internal radiotherapy Domenico Lizio 1, Ernesto Amato 2 and Sergio Baldari 2 1 : Department of Physics, University of Messina, Italy 2 : Department of Radiological Sciences, University of Messina, Italy

The need to store, transport and handle β − radioactive isotopes poses a safety problem arising from the potential exposure of workers and public to the directly ionising radiation emitted. This problem can be solved with low- Z material shields, which are able to absorb the high-energy electrons, maximising their energy loss by inelastic collisions and thus minimising the energy losses by radiative (bremsstrahlung) x-ray emission

When it is necessary to handle sources for purpose of, i.e., radiochemical or radiopharmaceutical preparations, special requirements can be posed on the thickness or shape of the shields, as well as on the physical properties of the materials such as : Trasparency Thermal conductivity Electrical conductivity Elasticity Range of operating temperatures

To study the attenuation properties of different plastic materials which can be employed to build effective shields in the various applicative contexts We developed a Monte Carlo simulation in Geant4 environment, in order to compare the attenuation properties as well as the relative bremsstrahlung X- ray production yield in the various plastic materials considered.

Our simulated set-up consisted of a collimated radioactive source of 90 Sr or 90 Y in contact with a thick slab of plastic absorber. The radioactive sources were chosen as representative of low- and high-energy  - emitters:  - radionuclides

We chose eight different types of plastic material characterized by densities ranging from 0.91 g/cm 3 to 2.16 g/cm 3, by different atomic composition and a variety of thermal, electrical, optical and mechanical properties: Plastic Material

Geant4 simulation The simulation was carried out using Geant4 version 9.1 on a Linux Ubuntu 8.04 workstation equipped with Intel Core 2 Duo processors at 1.8 GHz and 2 Gbytes of RAM. The statistical uncertainties (2  ) associated with the presented results of the Monte Carlo calculations are below 1%, less than the uncertainties on the relative experimental data taken as comparison. We briefly discuss the validation of the Geant4 processes relevant for our work and we present the results of our code in comparison with different reference data-sets for energy deposition, range and radiative losses for low- energy electrons.

Validation of Geant4 code By choosing the default values (cut = 1 mm and F R = 0.02), we found no statistically significant difference between the energy deposition calculated adopting the three physics packages (Standard, Livermore, Penelope). Adopting the standard physics and the default values for cut and F R, we compared our results with the SANDIA reference data for different electron energies and beam incidence angles, evaluated with respect to the normal to the target's surface. In table below we present some of our validation results.

With the same values for range cut and F R, we compared the CSDA range calculated in our simulation with the data from NIST for aluminium, water and all the plastic materials considered in our study. In figure below the comparison is shown for some relevant materials, revealing a full match. Validation of Geant4 code

We compared the fraction of electron energy lost by radiative emission from our simulation with the NIST reference data for a collimated beam of monoenergetic electrons on the same targets. The uncertainties in NIST data are reported to be within 5% below 2 MeV. Validation of Geant4 code

Results for 90 Y Absorption curves for some relevant materials Comparison of maximum ranges and number of X-rays emitted per 100 events

Results for 90 Sr Comparison of maximum ranges and number of X-rays emitted per 100 events Absorption curves for some relevant materials

Bremsstrahlung emission spectra for 90 Y source Bremsstrahlung emission spectra for 90 Sr radioisotope

Summary of 90 Y results The results indicate that 90 Y electrons are stopped in 5.2 – 11 mm of material, respectively PTFE and PP. ranges between 39.3 keV for PVC and 42.6 KeV for PET. Values for are between 0.33% for PP and 0.7% for PVC. N X /10 2 event between 7.72 for PP and of the PVC.

Summary of 90 Sr results The results indicate that 90 Sr electrons are stopped in 0.85 – 1.7 mm of material, respectively PTFE and PP. ranges between 14 keV for PP and 16.4 KeV of PTFE. Values for are between 0.09% for PP and 0.2% for PVC. N X /10 2 event are between 1.24 for PP and 2.73 for PVC.

PA and PC, with similar range and X-ray yield, are valid alternatives to PMMA in realizing low-Z transparent barriers for low- and high-energy  – emitters. PP can be privileged when X-rays must be kept at a minimum (15% less than PMMA) even if with a 25% of increase in the maximum range. PTFE can be a good choice for compact and high-temperature resistant shields, since it provides a 41% shorter maximum range with respect to PMMA, with a 34% of increase of X-ray production yield. PTFE should be definitively preferred to PVC, apart from its physical properties, because with larger density (2.16 versus 1.42 g/cm 3 ) achieves 30% reduction in R max together with 26% less X-ray photons. This effect is due to the presence of chlorine in the PVC formula. Conclusions

Reference E. Amato and D. Lizio “Plastic materials as a radiation shield for β − sources: a comparative study through Monte Carlo calculation” J. Radiol. Prot (2009)‏