Emergency Action Plans

Slides:



Advertisements
Similar presentations
OSHA Office of Training and Education
Advertisements

OSHA Regulations Part 1910 Subpart E
Emergency Action Plans
Fire Protection OSHA Part 1910 Subpart L.
Fire Prevention & Protection Gordon Cooper Technology Center
This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target.
FIRE PREVENTION & PROTECTION
Fire Prevention and Protection
This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target.
Subpart E Means of Egress.
Coverage and definitions. (a) Every employer is covered
Fire Safety II INSY 3020/7970/7976/ENH 670 Occupational Safety & Ergonomics.
Means of Egress and Fire Protection. 2 Objectives Understand Alarms and Warning Devices Know the location of Exits and Exit Routes Understand the RACE.
Means of Egress Fire Prevention and Protection
Objectives Design and construction requirements for exit routes
Fire Protection John Giefer. Statistics In the Drilling Industry In the Drilling Industry 25% of all inspections found violations of (21 inspections.
Portable Fire Extinguishers Selection and Placement University Safety Council April 19, 2006 Steven G. Triebold Fire Prevention and Protection Program.
1 Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
OSHA Long Term Care Worker Protection Program
Means of Egress & Fire Protection
1 FIRE EXTINGUISHER TRAINING Office of Environmental Health and Safety East Carolina University.
Emergency Action Plans/Fire Prevention Plans
Fire Safety and Fire Extinguishers
Employee Emergency Action Plans and Exit Routes Training Program.
EGRESS AND FIRE PROTECTION
Business Owners and Managers and the Fire Code
Means of Egress and Fire Protection
NO EXIT (adapted from OSHA Office of Training and Education)
1/05 Means of Egress WAC School Safety Training.
New Hire Initial Fire Safety and Prevention Training MHPHRM BR
Safety Training Presentation
Fire Safety and Prevention Plan
Occupational Safety and Health Course for Healthcare Professionals.
Subpart C General Safety and Health Provisions 29 CFR 1926.
Means of Egress and Fire Protection. Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long.
Exit Routes and Fire Protection
Safety & Health Consultation Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
Emergency Action Plans
Means of Egress and Fire Protection
Fire Extinguisher Training
Fire Safety Basics Presentation by: Tauni Aikin, Safety and Risk Consultant OmniSure Consulting Group, LLC.
OCCUPATIONAL SAFETY AND HEALTH Do you remember those school fire drills ? Well, here you go again !
Fire Extinguishers Hand Held Portables. Fire Extinguishers When faced with a fire, you must make some split second decisions: Do I want to put out this.
Means of Egress Don Ebert- Risk Manager (509)
Fire Protection OSHA Part 1910 Subpart L By: Joshua Spurlin.
EGRESS, FIRE PREVENTION & FIRE PROTECTION OSHA 29 CFR 1910 SUBPARTS E & L Bureau of Workers’ Comp PA Training for Health & Safety (PATHS) 1PPT
Department of Defense Voluntary Protection Programs Center of Excellence Development, Validation, Implementation and Enhancement for a Voluntary Protection.
Safety Rule #1 Open flames are not allowed without first obtaining a permit. The exception to this rule is during a period of closely supervised instructions,
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
Emergency Preparedness & Response
Means of Egress and Fire Protection
Emergency Action Plans
Fire Extinguisher.
Fire Safety and Prevention Plan
Fire Prevention and Protection
Table of Contents for Subpart E Coverage and Definitions
OSHA Office of Training and Education
Fire Safety and Prevention Plan
OSHA Office of Training and Education
Approval Sheets.
29 CFR NFPA Life Safety Code
Jay Industries, Inc. Fire Extinguisher Training Fire Prevention Plan
Fire Extinguisher Training
General Requirements of NFPA 101
Fire Prevention and Protection
Fire Prevention and Protection
Egress and Fire Protection
Jay Industries, Inc. Fire Extinguisher Training Fire Prevention Plan
OSHA Office of Training and Education
Fire Extinguisher Training
Presentation transcript:

Emergency Action Plans Subpart E Exit Routes Emergency Action Plans and Fire Prevention Plans 1910.33-1910.39

1910.34(c) Definitions Exit means that portion of an exit route that is generally separated from other areas to provide a protected way of travel to the exit discharge. Exit access means that portion of an exit route that leads to an exit. Exit discharge means the part of the exit route that leads directly outside or to a street, walkway, refuge area, public way, or open space with access to the outside.

1910.34(c) Definitions Exit route* means a continuous and unobstructed path of exit travel from any point within a workplace to a place of safety (including refuge areas). An exit route consists of three parts: The exit access; The exit; and, The exit discharge. *Equivalent to the term Means of Egress in the Life Safety Code and most local building and fire codes

1910.35 Compliance with NFPA 101-2000, Life Safety Code An employer who demonstrates compliance with the exit route provisions of NFPA 101-2000, the Life Safety Code, will be deemed to be in compliance with the corresponding requirements in § § 1910.34, 1910.36, 1910.37 NFPA

1910.36 (b) Fundamental Requirements Buildings maintained to provide free and unobstructed egress from all parts of the building at all times when it is occupied. No lock or fastening to prevent free escape from the inside of any building shall be installed except in mental, penal, or corrective institutions.

1910.36(d) Maintenance Every required exit, way of approach thereto, and way of travel from the exit into the street or open space, shall be continuously maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency.

1910.36(e)(1) A side-hinged exit door must be used A side-hinged door must be used to connect any room to an exit route Must swing out in the direction of exit travel if the room is designed to be occupied by more than 50 people or if the room is a high hazard area

1910.36(f) The capacity of an exit route must be adequate Exit routes must support the maximum permitted occupant load for each floor served See factors for occupant load and capacity the NFPA Life Safety Code - Chapter 7

1910.36(f) The capacity of an exit route must be adequate The capacity of an exit route may not decrease in the direction of exit route travel to the exit discharge

1910.36(g) Exit minimum height and width requirements Objects that project into the exit route must not reduce the width of the exit route to less than the minimum width requirements for exit routes

1910.37(a) The danger to employees must be minimized Exit routes must be kept free of explosive or highly flammable furnishings or other decorations

1910.37(b) Lighting and marking must be adequate and appropriate (4)If the direction of travel to the exit or exit discharge is not immediately apparent, signs must be posted along the exit access indicating the direction of travel to the nearest exit and exit discharge Additionally, the line-of-sight to an exit sign must clearly be visible at all times Way to exit is not apparent

1910.37(b) Lighting and marking must be adequate and appropriate (5)Each doorway or passage along an exit access that could be mistaken for an exit must be marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g., closet)

1910.38 Emergency action plans (EAP) (b) An emergency action plan must be in writing, kept in the workplace, and available to employees for review. However, an employer with 10 or fewer employees may communicate the plan orally to employees

1910.38(c) Minimum elements of an emergency action plan (1) Procedures for reporting a fire or other emergency (2) Procedures for emergency evacuation, including type of evacuation and exit route assignments (3) Procedures to be followed by employees who remain to operate critical plant operations before they evacuate

1910.38(c) Minimum elements of an emergency action plan (4) Procedures to account for all employees after evacuation

1910.38(c) Minimum elements of an emergency action plan (5) Procedures to be followed by employees performing rescue or medical duties

1910.38(c) Minimum elements of an emergency action plan (6) The name or job title of every employee who may be contacted by employees who need more information about the plan or an explanation of their duties under the plan Contacts ________

1910.38(d) Employee alarm system An employer must have and maintain an employee alarm system The employee alarm system must use a distinctive signal for each purpose and comply with the requirements in § 1910.165

1910.38(e) Training An employer must designate and train employees to assist in a safe and orderly evacuation of other employees EAP

Subpart L Fire Protection 1910.155-.165

Subpart L - Fire Protection (1910.155 - 165) Extinguishers - Training program * Extinguishers - Initial & annual training * Portable extinguishers - Provided and accessible * Standard: 1910. Extinguishers - Charged & operable * Extinguishers - Annual checks * *Average number of Federal OSHA citations issued between 2000 and 2003

Subpart L - Definitions "Class A fire" means a fire involving ordinary combustible materials such as paper, wood, cloth, and some rubber and plastic materials

Subpart L - Definitions "Class B fire" means a fire involving flammable or combustible liquids, flammable gases, greases and similar materials, and some rubber and plastic materials

Subpart L - Definitions "Class C fire" means a fire involving energized electrical equipment where safety to the employee requires the use of electrically nonconductive extinguishing media

Subpart L - Definitions "Class D fire" means a fire involving combustible metals such as magnesium, titanium, zirconium, sodium, lithium and potassium "Dry powder" means an compound used to extinguish or control Class D fires

Subpart L - Definitions "Class K fire" means a fire involving cooking oils such as those used in commercial kitchens and deep fryers.

How to Remember Fire Classes A—leaves Ash B—Boils C—has Current D—can Dent K—KFC

1910. 157 Portable fire extinguishers (a)Scope: The placement, Use, Maintenance, and Testing of portable fire extinguishers provided for the use of employees

(* If all three of the above points apply) Exemption: Where the written fire safety policy requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal and Which includes an emergency action plan and a fire prevention plan which meet the requirements of 29 CFR 1910.38 and 29 CFR 1910.39 respectively, and When extinguishers are not available in the workplace, the employer is exempt from all requirements of this section* (* If all three of the above points apply)

1910. 157(c) General Requirements If required: The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury mounted extinguisher is blocked with maintenance items

1910. 157(c) General Requirements Only approved portable fire extinguishers shall be used

1910. 157(c) General Requirements Assure that portable fire extinguishers are maintained in a fully charged and operable condition and kept in their designated places at all times except during use

1910. 157(d) Selection and distribution Provide portable fire extinguishers provided for employee use Are selected and distributed based on the classes of anticipated workplace fires and on the size and degree of hazards affecting their use

1910. 157(e) Inspection, maintenance and testing Portable extinguishers or stand pipe hose shall be visually inspected monthly

1910. 157(e) Inspection, maintenance and testing Portable fire extinguishers are required to receive an annual maintenance check. The employer shall record the annual maintenance date and retain this record for one year after the last entry