Elastic Measurements in an Operating Shoe Sole

Slides:



Advertisements
Similar presentations
Prevention of Running Injuries « Everything you must forget!»
Advertisements

Paul Thawley MSc Choosing the Correct Shoe
Team Members: Brant Kochsiek BSAC Steve Pauls Team Leader Tim Rand Communicator Brian Schwartz BWIG.
FIRST Shoe Clinic Numbers Running Mechanics Anatomy of Footwear Rules of Buying Running Shoes Apparel Basics Todays Agenda Sponsored by: 1708-A Augusta.
Troy M. Smurawa, M.D., FAAP Akron Childrens Hospital Sports Medicine Center BAREFOOT RUNNING: IS IT FOR EVERYONE?
ETHICS. Business Conduct  The Agent agrees to conform to all applicable federal, state and local laws in conducting business under this agreement.
Manufacturing Processes MIME 2650 Ioan D. Marinescu, Ph.D. Professor Professor MIME Office NI 4037, NE 1043
Medflight Helmet Design Patrick Schenk, Ben Roedl, Brett Mulawka, Joe Long, Mike Oldenburg Client: Dr. Michael Abernethy Advisor: Professor Willis Tompkins.
Adam McGinnis Fox Trot Runners, Inc. Untying the Knot: Deciphering the run specialty jargon.
Mass Flow Controller System Client: Brad Hodgeman– Instrumentation Specialist, Comparative Biosciences Advisor: Professor Emeritus John G. Webster Team.
Primary functions of running shoes -Reduce high pressure areas -Reduce excessive rearfoot pronation -Reduce impact forces -Reduce take-off supination of.
Running and Court Shoes n Assignments: -Read Ch 2 of Kreighbaum & Smith -Submit 2 questions from readings for discussion n Primary functions of running.
Peak Inspiratory and Expiratory Flow Meter Team: Andrew Eley, Sarah Offutt, Darshan Patel, Eric Bader BME 200/300 December 2, 2005.
Ergonomic Ultrasound Probe
Arches of the Foot Insoles as Treatment March 23, 2015.
History of the Running Shoe. Running as a sport can be traced back to the ancient Greeks, who advocated a culture based on sound bodies and sound minds.
Team Members: Joe Bothwell BWIG IT Ryan Fischer Communicator Brant Kochsiek Team Leader Brian Schwartz BWIG David Ugai BSAC Dan Carlson BSAC.
Accessible Syringe Dosing Jeff DeLorme Elese Hanson Christine Weisshaar Andrew Wentland Advisor : Willis Tompkins.
BME DESIGN 200/300 MICROSCOPE MANIPULATOR UW Medical Physics Department Contact Info:
Skin Color Monitor Sarah Offutt, Rachel Mosher, Victoria Vasys BME 301 March 7, 2008.
Team Members: Joe Bothwell Communicator Kelly ToyTeam Leader Jon Cappel BWIG Karim Mahamud BSAC.
 Feet sustain 2 or 3 times your body weight  Each foot has more than 100 muscles, tendons, and ligaments  6 times force of gravity is exerted on the.
BME Longitudinal Design Teams Freshmen to Senior BME students working together in teams to solve problems involving biomedical engineering design, culminating.
Fatigue behavior of the foam Load and displacement are monitored throughout the test at a rate of 150Hz. The data collected are then analyzed using a custom.
Field Measurement of Running Impacts Team: Chelsea Wanta, Amanda Feest, Matt Kudek, Nicole Daehn, Lindsey Carlson BME 201 March 9, 2007 Client: Dr. Bryan.
Don’t Forget Basic Training Principles... n Warm-up –Specificity n Stretching –Before vs. After n Cool-down.
Your Logo Garth Fletcher Kyler Hast Kyle Meredith Maria Miro Ryne Wickery Cecilia Wong February 13, 2014 Advisors Dr. K. Amin Dr. D. Olawale Team Members.
Choosing the Correct Shoe
Automated Syringe Dosing: The EasyMeasure Syringe Hanson, E.E., Weisshaar, C.L., Wentland, A.L. Biomedical Engineering University of Wisconsin – Madison.
Solar Powered Blood Pressure Assist Device Laura Allen 1, James Berry 2, Casey Duckwall 2, David Harris 1 Advisor: Dr. Franz Baudenbacher 2 Department.
1 SIGCSE Panel on Client-Sponsored Projects - T.C. Lethbridge Experiences with Client- Sponsored Projects (Project Assessment) Timothy C. Lethbridge University.
Analysis of Runner Biomechanics Using Edge Detection and Image Processing Techniques to Determine Pronation Levels Asa Kusuma.
Analysis of Runner Biomechanics Using Edge Detection and Image Processing Techniques to Determine Pronation Levels Asa Kusuma.
MEDIATION THE KEY TO REDUCING THE COST, STRESS AND TIME NECESSARY FOR INTER AND INTRA-ORGANIZATIONAL AND PERSONAL DISPUTES AND LITIGATION PRESENTED AS.
Technical Information & FAQ. Benefits: Efficiency and cushioning Less wear and tear for your muscles People feel a ‘great ride’ Testing: 17,500 miles.
Displacement and Motion Measurement
Results Conclusions Development of an Pronation Controlling Suspension in Running Shoes Caroline de Monasterio, Brandon Jackson, Philip O'Bannon, Robin.
Spikes made from plastic Outsole made from plastic Inside cleat- Insole made from a type of foam Midsole made from a cushioned material Upper made from.
BME Design 200/300 Glaucoma Medication Reminder. Intellectual Property  All information provided by individuals or Design Project Groups during this.
ROBOTICS 01PEEQW Basilio Bona DAUIN – Politecnico di Torino.
University of Wisconsin - Madison Biomedical Engineering Design Courses All information provided by individuals or Design Project Groups during this or.
By: Mason Jellings, Sarah Reichert, John Byce, and Justin Gearing Advisor: Prof. Tom Yen Client: Dr. Joshua Medow Instrument Controlled Microscopy for.
Manual Ventilator Project Peter Ma, Richard Long, Matt Valaskey, Jimmy Fong Client: Michael K. Abernethy, MD, FACEP Advisor: Paul Thompson, PhD
University of Wisconsin-Madison Biomedical Engineering Design Courses INTELLECTUAL PROPERTY STATEMENT All information provided by individuals or Design.
Arin Ellingson Anika Lohrentz Ben Schoepke Alice Tang Advisor- Paul Thompson Ph.D. Client- Ken Schreibman M.D., Ph.D.
Roller PATH: A Patient Transfer and Positioning Aid for Medical Imaging Team Members Josh Anders, Leader Megan Buroker, Communicator Alyssa Walsworth,
Team Members: Sara Karle Ashley Matsick Michele Lorenz Emily Maslonkowski Client: Dr. Mihai Teodorescu Advisor: Prof. Mitch Tyler.
Gas Pressure Meter (Engineering World Health) Advisor: Professor Naomi Chesler Client: EWH and Professor John Webster Team Members: Ksenija Bujanovic-
INTRACRANIAL PRESSURE MONITOR Dan Frost Rebecca Koszalinski Justin Lundell Michael Socie Advisor: Professor Naomi Chesler, UW-Madison Client: Joshua Medow,
Determine method of rapid prototyping or plastic extrusion to create prototype of true-to-scale catheter Determine optimal slot size without affecting.
Adjustable arm for an ultrasound probe during peripheral nerve block procedures Team Members: Sara Karle Michele Lorenz Emily Maslonkowski Ashley Matsick.
University of Wisconsin - Madison Biomedical Engineering Design Courses INTELLECTUAL PROPERTY STATEMENT INTELLECTUAL PROPERTY STATEMENT All information.
Finding the best shoes for your plantar fasciitis is not an easy task because there is a need to understand the multitude of footwear options that is currently.
INTELLECTUAL PROPERTY STATEMENT
Team: Michael Alexander, Samantha Bergh, Mollie Lange and Peter Ma
Running Gait.
Pulse Transit Time Measuring Device
Digital Braille Watch Alice Tang | Alison Boumeester
Intracranial Pressure Monitor
Biomedical Engineering Design Courses INTELLECTUAL PROPERTY STATEMENT
Endotracheal Tube Pressure Monitor
INTELLECTUAL PROPERTY STATEMENT
WELCOME TO MY PROJECT WORK.
Peak Inspiratory and Expiratory Flow Meter
Embedded Biomaterial Failure Detection
Accessible Incontinence Device
Transcranial Magnetic Stimulation Positioner
Breast Pedicle Protector
Continuous Passive Motion Hand Rehabilitation
Key Question: What is a simple machine?
Presentation transcript:

Elastic Measurements in an Operating Shoe Sole BME 301 Steven Pauls, Timothy Rand Brian Schwartz, Brant Kochsiek Advisor: Professor Naomi Chesler Client: Professor David Beebe March 5, 2004

University of Wisconsin – Madison Biomedical Engineering Design Courses INTELLECTUAL PROPERTY STATEMENT All information provided by individuals of Design Project Groups during this or subsequent presentations is the property of the University and of the researchers presenting this information. In addition any information provided herein may included results sponsored by and provided to a member company of the Biomedical Engineering Student Design Consortium (SDC). The above information may include intellectual property rights belonging to the University to which the SDC may have l license rights. Anyone to whom this information is disclosed: 1) Agrees to use this information solely for purposes related to this review; 2) Agrees not to use this information for any of her purpose unless given written approval in advance by the Project Group, the Client / SDC, and the Advisor. 3) Agrees to keep this information in confidence until the University and relevant parties listed in Part (2) above have evaluated and secured any applicable intellectual property rights in this information. 4) Continued attendance at this presentation constitutes compliance with this agreement.

Problem Statement Device should fit into the sole of a shoe Inform runner when shoe is worn Decrease incidence of injury due to shoe wear Measure the elasticity of the shoe sole Direct measurement Other methods

Problem Motivation Running shoes last 300-500 miles Worn shoes not always “worn” Incidence of injury increases with worn shoes Diagnostic tool in relation to running style

Client Requirements Lightweight Ergonomic with sole Operable for life of the running shoe Should not hinder performance Have clear indicator

Elastic Effect Elastic recoil cushions impact Age/Wear decreases elastic effect Similar stresses create more strain on material

Shoe Materials Ethylene and Vinyl Acetate (EVA) Polyurethane (PU) Upper Footbridge Midsole Outsole http://www.dummies.com/WileyCDA/DummiesArticle/id-450,subcat-SPORTS.html

Pronation Styles Wet sand imprints indicating foot shape and pronation style Most common strides (note: underpronation is also termed supination) http://www.dummies.com/WileyCDA/DummiesArticle/id-450,subcat-SPORTS.html

Shoe Wear Patterns Forefoot Striking Neutral Overpronation Supination http://www.fleetfeethouston.com/tips/basics.asp

Principles Design Matrix Electrical Mechanical Chemical Complexity 3 1 Feasibility 2 Cost Performance Total 11 8 7

Strain Gauge Directly affected by elasticity (ε = σ ∕ E) Inexpensive Small Requires calibration Incorrect alignment http://www.dur.ac.uk/richard.scott/gauges.html

Conductive Polymer Force Sensor Resistive elements Medium to high pressure range Compact Indirect Measurement Requires calibration http://interlinkstore.com

Force Differential Impact creates force (F), smaller dispersal force (f) F α f as a function of shoe sole force absorbance Force absorbance during impact is a function of elasticity Set ratio F:f will trigger sensor, indicate elastic wear

Retroreflectors Advantages Disadvantages Small, lightweight, & cheap Only taking one measurement (distance) instead of two Virtually no wear on device Disadvantages Need for clear polymer in some portions of the shoe sole Distance measurement may not correlate to shoe sole elasticity

Future Work Polymer which degrades faster than EVA or polyurethane Integrate retro-reflector, strain gauge, & a conductive polymer force sensor into polymer mold Perform tests to determine which device is able to detect wear (elasticity) the best Determine correlation between shoe wear and output of each device Select ultimate wear value Integrate chosen device into a shoe sole for field testing Possible patent application

Prototype Design Matrix Retro-Reflectors Strain Gauge Conductive Polymer Performance Cost Reliability Size/Weight Totals

Acknowledgments Professor Naomi Chesler Professor David Beebe Professor John Webster UW Biomedical-Engineering Dept.