Nursing Instructions for the Tru-Close® Suction Drainage System

Slides:



Advertisements
Similar presentations
Site Saver training is designed to help secure an IV site within seconds.
Advertisements

Contents & Uses of common IV fluid
Fresenius Medical Care Peritoneal Dialysis Connections
Leisure Vac Auto pool Cleaner. Trouble shooting Guide: Top Head Assembly Problem: Debris in the top head, causing cleaner to not work due to poor water.
Fresenius Medical Care Peritoneal Dialysis Connections
Fresenius Medical Care Peritoneal Dialysis Connections
Fresenius Medical Care Peritoneal Dialysis Connections
Fresenius Medical Care Peritoneal Dialysis Connections
Practical Nursing Diploma Program - Semester 2 Lab Oxygen therapy, Incentive Spirometry, Pulse Oximetry &Sputum Collection.
Anesthesia Machine Presented by Gil Soto C.R.N.A.
RadiStop™ Compression Assist Device
Boussignac CPAP System
2 Fire Fighter Qualifications and Safety Skill Drills.
1 FUEL SYSTEM SERVICE ENGINE CLEAN FUEL TOOL MODEL RX 777.
Radiopharmaceutical Production Filter integrity test STOP.
High-Pressure Air Bags 101
Blood Transfusion Nursing Procedure. *Whole blood transfusion replenishes the circulatories:  Volume  Oxygen-carrying capacity *Packed Red Blood Cells.
Principle Concepts of Iv therapy.
Technical support provided by: Highly Pathogenic Avian Influenza Control Programme SOP Use and Maintenance of High Pressure Washer Machine Market chain.
Determination of the Ideal Gas Constant Go to browse and the full screen.
Indications & Management of ICC’s & UWSD’S
UreSil Tru-Set Locking System
Nursing Instructions for the Tru-Close® Thoracic Vent
1 Expansion Tanks. 2 3 Expansion Tanks WHY USE THEM TYPES LOCATION SIZING.
Arterial Catheters Systemic arterial blood pressure is most accurately measured by placing a catheter directly into a peripheral artery. Peripheral arterial.
Preparation of Ribavirin solution for Nebulisation: 6g in 100ml The following guidelines for the safe reconstitution (in the patients room) of ribavirin.
Urinary – Nephrostomy Catheter Care
ResQmax Line Deployment Kit -ResQmax Launcher- 5 nozzle protectors -2 Streamline Projectiles- O-ring kit -500’ 3mm line with container- Corrosion block.
Easy and inexpensive production of small quantities of 15 N 2 Step-by-step tutorial (Prepared by Juan-Pablo Hernandez) Step-by-step tutorial (Prepared.
Filling, purging and air removal
Dennis Sabre Fire Appliances
Skilled Trades 1201 Residential Plumbing.
Surgical Instruments and Terminology 4-H Veterinary Science Extension Veterinary Medicine Texas AgriLife Extension Service College of Veterinary Medicine.
Hydronic Mechanical Controls
Surgical Asepsis and Wound Care Equipment: ABD pads Sterile 4x4’s Betadine swabs Cotton tip applicators Silk tape, paper tape, canvas tape, Montgomery.
1 July 2007 P48610 Rev.2 SmartInfuser PainPump ™ P49220, P49224N Operation Instructions.
HVAC523 Circulator Pumps.
Avantae L. Cruz, RN, BSN CHEST TUBES Do’s and Don'ts.
The Disposable Infusion Pump Instruction Basal + PCA Bolus Model.
Fresenius Medical Care Peritoneal Dialysis Connections
AJ5806 PCA INFUSION PUMP Quick Operating Instructions.
Managing Symptoms at the End of Life When the Oral route Fails.
AJ5808/5808A INFUSION PUMP QUICK OPERATION GUIDE.
ASSISTED VENOUS DRAINAGE
Surgical instruments Dr. Abdussalam M jahan ENT depart, Misurata university, faculty of medicine.
Removing an Indwelling Catheter ACC RNSG 1341 online.
Catheter Types and Care for Residents with Catheters
Subacute Care Chapter 25 Subacute Care Care for Residents With Specific Needs Formerly cared for in Hospital Rehabilitation Complicated Respiratory Care.
Metal Fabrication Oxygen & Acetylene Integra ® Cylinders 2014.
Copyright © 2007, 2003 by Mosby, Inc., an affiliate of Elsevier Inc. Chapter 20 Urinary Elimination.
OILGEAR PVV PUMPS PVV 200 Performance Curves.
Intravenous Administration Nurses administer meds IV in the following ways: – As mixtures within large volumes of IV fluids (Banana bag) – By injection.
World federation of neuroscience nurses
Copyright © 2010 Delmar, Cengage Learning. ALL RIGHTS RESERVED. Chapter 15 Introduction to IV Therapy.
EBS-1 # COOLANT FLUID EXCHANGE QUICK REFERENCE ATTENTION: Using the Coolant Fluid Exchange requires the FILL and VAC Valves on the SERVICE.
Starting an IV Hanging a Primary IV Solution Hanging an IV Piggy Back Programming an IV Pump Lab Skills.
CANTY QUICKPORTS™ “How they work”
ADMINISTERING OXYGEN.
OBJECTIVES Discuss the various methods of loosening the brake bleeder valve. Discuss the need for brake bleeding. Describe the manual bleeding procedure.
Valve Drainage of the Pleural Cavity
Frames Footwear and Foot-ups: The Birmingham Experience Mark Raven & Philippa Bridgman Introduction The presence of foot wires in circular frame external.
Integrated Disposable
Nursing Instructions for the Tru-Close® Thoracic Vent
Setup & Use - Integrated Set
William Kirke Rogers, MD, Luis Garcia, MD  CHEST 
CAREFUSION PLEURX CATHETER COMPETENCY
Introduction to IV Therapy
Presentation transcript:

Nursing Instructions for the Tru-Close® Suction Drainage System

TCS Drainage System for Post Surgical Abscesses, and Ascites Drainages

TCS Drainage System Configurations Available in capacity sizes of 1000ML, 500ML and 300ML Sizes with drain port include the TCS300D and the TCS500D All have 25” silicone drain tube which can be adjusted in length by cutting the tube at the point where it connects to the bag and then re-attaching Vacuum level for the TCS300D is 4.5 psi (230 mm Hg) Vacuum level for the TCS500, TCS1000 and TCS500D is 2 psi (103 mm hg)

Flush Adapter (AFA-01) The AFA-01 Flush Adapter is sold separately and is to be used when flushing of the catheter is required It has a tube clamp for injection or aspiration of the catheter and to prevent solution from refluxing The needleless, swabable port allows for injection of flushing solutions and aspiration The device comes with a standard Luer Lock fitting and a large bore adapter for the ULTI-flo system To attach the Flush Adapter (AFA-01) remove the Luer Lock connector from the bag tubing and replace it with the tapered connector on the end of AFA-01

Using the TCS Drainage Bags Designed for “closed wound drainage” Equipped with a standard Luer Lock connector to fit all brands of percutaneous drainage catheters If catheter is to be flushed it is recommended that a stopcock or the UreSil Flush Adapter (AFA-01) be attached to the distal end of the tubing prior to hooking the bag to the catheter Vacuum is activated by compressing the bellows at the top of the bag When the bellows is released the fluid will fill the bellows

Using the TCS Drainage Bags(cont.) To reactivate the vacuum depress the bellows The fluid in the bellows will be forced into the bag Dual anti-reflux valves prevent fluid from going up the tubing and back into the catheter The TCS bags will revert to gravity flow if the bellows is full; for gravity drain ensure the bag is below the level of the point being drained Two vents at the top of the bag will prevent air buildup in the bag; you do not have to force air from the bag Only the TCS500D and TCS300D can be emptied without detaching the bag from the catheter

Managing the Patient To maintain the integrity of the closed system ensure an appropriate flushing apparatus (stopcock or AFA-01) is in place prior to attaching the tube to a catheter Attach the bag to the patient’s garment using the clamp secured to the Velcro strap at the top of the bellows housing Do not attach the unit to the drop rail on the bed, attach it to the bedding Instruct the patient on the operation of the TCS so they activate the bellows as needed Drainage and critical measurements (marks on the bag are for reference only) can be taken from the drain port without disturbing the patient; close the drain after use The TCS1000 and TCS500 cannot be drained

Conclusion When using the Tru-Close Suction Drainage System always refer to the IFU contained in the product package. If you have technical questions relating to the Tru-Close Suction System please contact UreSil Customer Service at (800) 538-7374. Thank You