Www.chemicalfingerprinting.laurentian.ca BALZ S. KAMBER Laurentian University Ultra-high purity ICP-MS.

Slides:



Advertisements
Similar presentations
The Separation of Beryllium from Spectral Interfering Elements in Inductively Coupled Plasma – Atomic Emission Spectroscopic Analysis Daniel R. McAlister.
Advertisements

InfraCal TOG/TPH Analyzers for Oil and Grease Measurements
AAS and FES (Ch 10, 7th e, WMDS)
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
Analysis in ProcESS Xuan Wang Department of Chemical Engineering Department of Metallurgy and Materials Engineering 23/01/2013.
Result validation. Exercise 1 You’ve done an analysis to the best of your ability using the correct procedure. Is your answer correct? possibly, hopefully.
Mercury Monitoring The FDEP Laboratory Perspective Timothy W. Fitzpatrick (850)
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Technical Updates on UTEVA, TEVA and TRU Resins
Standard Addition Used with difficult matrices such as blood Difficult to get an accurate comparison of the amount of analyte in sample vs. amount of analyte.
Quiz Time 05:00 04:0003:0002:0001:3001:0000:4500:3000:1500:00.
Instrumental Chemistry Chapter 11 Atomic Mass Spectrometry.
Materials Assay & ICPMS for DUSEL R&D
Lead Content in Toys Katrina Nowak Chemistry 4101 Fall 2008.
Exposure to Zinc Oxide and Titanium Dioxide Nanoparticles in Sunscreen Heidi Nelson December 9, 2011 CHEM 4101.
MiniSIMS Secondary Ion Mass Spectrometer Dr Clive Jones Millbrook Instruments Limited Blackburn Technology Centre, England
Detection of Copper in Wastewater Seth Holm Chem4101 December 2009.
QUANTITATIVE ANALYSIS & BASIC TOOLS MISS NOORULNAJWA DIYANA YAACOB School of Bioprocess Engineering University Malaysia Perlis 02600, Kangar Perlis
Mass spectrometry 8/23/12 What are the principles behind MS?
Concentration.
Isotope Ratio Performance of an Axial Time of Flight ICP-MS Stuart Georgitis 1, Lloyd Allen 1, and Janos Fucsko 1, Frank Vanhaecke 2 1 LECO Corporation.
1 FDA Survey of Lead in Pharmaceuticals John F. Kauffman, PhD R&D Team Leader CDER, Division of Pharmaceutical Analysis ACPS-CP Meeting July 22,2008.
Proposal for high sensitive measurements of 238 U and 232 Th with NAA Ezio Previtali INFN Sez. Milano Milano-Bicocca University ILIAS: JRA1 3rd General.
Atomic Emission Spectroscopy
Materials Characterization Lab Elemental Analyses by ICP-AES Henry Gong, Senior Analytical Chemist September 10, 2008.
Importance of ultra pure water for analytical research and testing techniques -impact of laboratory water handling and storage procedures on its purity.
Field Methods of Monitoring Atmospheric Systems Chemical Analysis of Particulate Matter Copyright © 2006 by DBS.
The determination of lead by MD-HG-AFS in APMP*-QM-P3 comparison Lu Xiaohua, Lu Hai, Ma Liandi, Cui Yanjie National Research Center for Certified Reference.
in tin pest and pest free Monika Leodolter-Dvorak and Ilse Steffan
Mass spectrometry Ions are analyzed on the basis of their m/z Chlorine has 2 isotopes, 35 Cl and 37 Cl, in the approximate ratio of 3 :1. Electrons are.
Atomic Absorption Spectroscopy
Role of Water in Ion Analysis Telis Dimitrakopoulos, Alan Mortimer & Paul Whitehead ELGA LabWater, Lane End Industrial Park, High Wycombe, HP14 3BY, UK.
Standard Addition Used with difficult matrices such as blood Difficult to get an accurate comparison of the amount of analyte in sample vs. amount of analyte.
The Separation of Beryllium from Spectral Interfering Elements in Inductively Coupled Plasma – Atomic Emission Spectroscopic Analysis Daniel R. McAlister.
1 ERT 207 Analytical Chemistry ERT 207 ANALYTICAL CHEMISTRY ALINA RAHAYU MOHAMED School of Bioprocess Engineering University Malaysia Perlis 02600, Kangar.
Less Manganese lost over C Manganese in Sea Water Excessive Background signal from NaCL Large loss of analyte.
Quality Assurance How do you know your results are correct? How confident are you?
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
7-1 Atomic Mass Spectroscopy General Features Mass Spectrometers §Sources Atomic mass spectroscopy determines elements by mass §Mass to charge ratio §Lower.
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
The Determination of Be in an Enriched Uranium Matrix YGG Darrin K. Mann, D.H. “Bo” Bowman, Thomas J. Oatts, and Vicki F. Belt Analytical Chemistry.
Data Analysis and Presentation Chapter 5- Calibration Methods and Quality Assurance EXCEL – How To Do 1- least squares and linear calibration curve/function.
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/26/2006Chapter 3ICPMS Interference equations Isobaric.
Eliminating Molecular Interferences in ICP-MS for the Simplest Method Development Dr. Torsten Lindemann.
Atomic-absorption spectroscopy
Rapid actinide measurements in environmental samples Dr Phil Warwick Geosciences Advisory Unit Southampton Oceanography Centre.
A screening facility for next generation low-background experiments Tom Shutt Case Western Reserve University.
CHM 410/1410 Lecture 2 Environmental Sampling. Environmental sampling Two things to consider: 1.Size of the samples required 2.Number of samples required.
Chem. 133 – 4/26 Lecture. Announcements Return graded quiz and additional problem Lab – Lab report deadlines (2:4 – Thursday) Today’s Lecture – Mass Spectrometry.
Chemistry 4631 Instrumental Analysis Lecture 18 Chem 4631.
Stoichiometry: Quantitative Information About Chemical Reactions Chapter 4.
Introduction to Geochronology Part 4: Rocks into Ratios Geochronology & Tracers Facility NERC Isotope Geosciences Laboratory British Geological Survey.
Chapter 29 Mass Spectrometry. 29 A Principles of mass spectrometry In the mass spectrometer, analyte molecules are converted to ions by applying energy.
Solution Concentration.  Lesson Objectives  Describe the concept of concentration as it applies to solutions, and explain how concentration can be increased.
Unit 12 Solutions And you. OBJECTIVE To gain informed insights into reactions that take place in aqueous environments you need to have a solid conceptual.
M. Fernández, E. Conde, A.I. Barrado Department of Technology
Sediment Sample Digestion Method
iCAP OES Analysis of Trace Elements in Hair
Etch Dry and Wet Etches.
The Analysis of Soils and Waters in Accordance with U. S
Ultimate Clean Digestion Cups and Clean Lab Testing
ICP-MS ICP – Inductively Coupled Plasma MS – Mass Spectrometry
Technical Updates on TRU and TEVA Resins
Quantifying the Efficiency of Different Solid Sample Digestion Methods: A Comparison of Time, Cost, and Accuracy Connie Hayes.
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
Sediment Sample Digestion Method
remove 167 mL aliquot for Sr-90 spike with 1 mg stable Sr carrier
Suppose we make a new compound containing of C,H, and N
Presentation transcript:

BALZ S. KAMBER Laurentian University Ultra-high purity ICP-MS

Drivers behind geo- and cosmochemical analysis Desire to analyze sub- nanogram quantities of implanted solar wind, returned cometary material, dust in Antarctic ice, etc.

Analytic equipment: SIMS Secondary ion mass spectrometer Pros: Ideal for in situ analysis, quasi non- destructive, high spatial resolution, high mass resolution, for some elements ppt detection limits Cons: sample in ultra-high vacuum, requires perfect surface for ppt analysis, matrix effects, slow, and $

Analytic equipment: ICP-MS Inductively coupled plasma mass spectrometer Pros: ppq detection limits, can work in situ or analyze digests, samples at atmospheric P, matrix insensitive, fast, relatively inexpensive Cons: destructive, requires more material than SIMS, prone to blank contamination during sample preparation, may require elemental pre- concentration

Solution ICP-MS

Instrumental limits: ICP-MS Sensitivity: 450,000 cps ppb -1 Detection limit: 1 cps Consumed mass:2 grams Absolute mass of detected material: 4-5 femtograms ( g) Dilution factor (solution/solid ratio): 1,000 Hence in 2 g of solution, only 2 mg of solid translates to minimum detectable concentration of 4-5 nanograms g -1 (ppt)

Current standard practice for easy metal (e.g. Cu) Up to 0.25 g of sample dissolved Metal or alloy dissolves slowly in 10% HNO 3, in pre-cleaned 0.25 L PP bottle Take 2 g aliquot, add internal standard for drift correction and run on ICP-MS Analysis includes a semi-quantitative mass scan

Simple metal results

Note outlier

Current standard practice for pesky metal (e.g. certain bronzes) Up to 0.25 g of sample dissolved Alloy attacked by aqua regia in ultra-clean Teflon vials at 160degC, converted with HNO3 and taken up in 10g of 20% HNO 3 Take 0.24 g aliquot, add internal standard for drift correction, dilute to 6 g with H 2 O and run on ICP-MS Abandoned U & Th pre-concentration (blank) Analysis includes a semi-quantitative scan

Current standard practice for Si- based, HFSE-doped chips Very small chips (a few mg) rinsed in ultra- clean 5% HNO 3 Attacked in ultra-clean Teflon vials with 0.25 mL HNO 3 conc. and 0.5 mL HF conc. 160degC Conversion with HNO 3 to boil off Si as SiF 4 and taken up in a few g of 5% HNO 3 with internal standards Run on ICP-MS, including a semi-quantitative scan

Chip results 10 mg samples Chip results sub 10 mg samples

Chip results semi-quantitative mass scan

Ideas for new procedures Wipes Metals and chips: improve detection limits by chromatographic matrix exclusion Pre-concentrated U and Th: improve blanks and counting statistics by laser ablation Addition of 234 U and 229 Th spikes

Wipes Combust in quartz crucibles in SNO above-ground facility Take-up ash into 6mL Teflon vessel Digest ash in 0.2mL HF Convert with HNO 3 and analyze in 2 mL of 5% HNO 3 with internal standards Common procedure for environmental samples (peat)

Matrix removal Previous efforts at pre-concentrating Th and U focused on ion chromatography that specifically retains U and Th This is the method preferred by Patricia Grinberg For small samples, this method reaches a blank limit as the U-TEVA resin itself appears to contain a blank Alternative is to remove matrix (all 1+, 2+ and 3+ charged cations) on cation exchange resin

Analyze pre-concentrated U and Th as a UV-laser induced aerosol Dry down U and Th pre-concentrate into inert clean Teflon vial Vaporize residue (and Teflon) with a few pulses of an Excimer laser Transport aerosol into ICP-torch in % He clean stream

UV- laser idea

Analyze pre-concentrated U and Th as a UV-laser induced aerosol Higher ionization efficiency, larger signal, lower blank But need for yield monitor: isotope dilution Addition of known amount of isotopically enriched 234 U and 229 Th

Outlook Simple metals with low contamination risk and wipes can be handled with existing protocols in lab Dangerous metals (Pb, certain bronzes) and HFSE-doped chips need to be digested in a non- geochemical/cosmochemical lab We can train personnel to learn these techniques Publication quality experiments should be performed by a Postdoc