SIMATIC S7 Software Redundancy

Slides:



Advertisements
Similar presentations
Automation and Drives.
Advertisements

Express5800/ft series servers Product Information Fault-Tolerant General Purpose Servers.
Engineering/commissioning
1 A&D CD PD /March 2001/ Profibus_en Internet: Intranet: Power Distribution.
SIRIUS Motor Management
Motorola General Business Use MOTOROLA and the Stylized M Logo are registered in the US Patent & Trademark Office. All other product or service names are.
VL/WL Software Offerings
SIMATIC ET 200M / MP Systemredundancy
P3- Represent how data flows around a computer system
1 Course Number Presentation_ID © 2001, Cisco Systems, Inc. All rights reserved. Cisco 7500 High Availability.
Engineering Redefined
/// MELSEC Safety /// QS001CPU /// QS0J61BT12 /// QS0J65BTB2-12DT /// MELSEC Safety /// Mitsubishi Electric - MELSEC Safety - Training Documentation -
IndraMotion MLD-S IndraMotion MLD-M Number of Inputs and Outpus.
Automation and Drives Applications with IE/PB Link  Verticale integration using engineering tools like SIMATIC PDM or Drive ES  Remote diagnostic / remote.
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Active Stations PC PLC PROFIBUS Passive Stations (Field Devices)
Parts & Functions of a Computer. 2 Functions of a Computer.
DriveAP 1.2 & 2.1 DriveWare®.
A&D AS CS2 FA Systems Support Powered by A&D AS CS2 FA SIMATIC Technical ConsultingPage 1February 2005 Overview Redundancy features Configuration Communication.
Lecture 3&4 Components of the computer. Computer components.
Date: File:MC-SMO-SYS_10.1 SIMOTION Siemens AG All rights reserved. SITRAIN Training for Automation and Drives Connecting HMI Systems.
 A system consisting of a number of remote terminal units (or RTUs) collecting field data connected back to a master station via a communications system.
Programmable Logic Controller Internal Operations
Setup Guide - Profibus communication AC141x with Step 7 V5.5 English
PROFIBUS "Ready for anything!".
Notes: For the installation of a PB network, you can use shielded twisted pair copper cable, glass or plastic FO and infrared components. And you can mix.
Automation and Drives Peer to peer communication between control platforms PROFINET.
Slow Control Activities in FZ Jülich H. Kleines, F. Suxdorf,, K. Zwoll Zentrallabor für Elektronik (ZEL), Forschungszentrum Jülich –What is ZEL? –Industrial.
SIMATIC WinCC V5.0 WinCC V5 Under Windows NT.
PLC: Programmable Logical Controller
Agenda: - Overview of PDM - Example of how to connect to a LR200
A FOUNDATION FIELDBUS System
Date: File:ST-PCS7SYS_V6_üb_pro_E.1 SIMATIC PCS 7 Siemens AG All rights reserved. SITRAIN Training for Automation and Drives Configuration.
Input / Output CS 537 – Introduction to Operating Systems.
EtherCAT Protocol Implementation Issues on an Embedded Linux Platform
Technology Date 10/17/00, Page 1 Technology s PROFIBUS Technology Chips - Modules - Development Kits.
trends in distributed control systems
Chapter 7 AC 800M Hardware Course T314.
InnovationValueTeamwork SHENZHEN INVT ELECTRIC CO., LTD.
Automation and Drives Siemens Automation Cooperates with Education A&D AS SM GE /2006, Page 1 © Siemens AG Subject to change Trainer Package.
1 A+ Guide to Managing and Maintaining Your PC, Fifth Edition Hardware Needs Software to Work Hardware  Physical components of a computer  Visible part.
A+ Guide to Managing and Maintaining Your PC Fifth Edition Chapter 1 Introducing Hardware.
Input/ Output By Mohit Sehgal. What is Input/Output of a Computer? Connection with Machine Every machine has I/O (Like a function) In computing, input/output,
Windows Control Center
Siemens Energy & Automation, Inc. sinamics SINAMICS S120.
ITER – Interlocks Luis Fernandez December 2014 Central Interlock System CIS v0.
DeviceNet Solution December, 2003
A First Look at WirelessHART ® An e-book by Pepperl+Fuchs.
Turck Fieldbus technology. A010 2 Components for: PROFIBUS-DP DeviceNet™ Interbus AS-Interface® CAN Open Ethernet -Modbus TCP -Ethernet/IP -ProfiNet Product.
SIMATIC Overview Automation and Drives SIMATIC Industrial Automation System.
 AUTOMATION  PLC  SCADA  INSTRUMENTATION  DRIVES & MOTORS.
Henri Kujala Integration of programmable logic into a network front-end of a telecontrol system Supervisor: Professor Patric Östergård Instructor: Jouni.
Date: File:PRO1_12E.1 SIMATIC S7 Siemens AG All rights reserved. Information and Training Center Knowledge for Automation Troubleshooting.
Communication via MPI Contents Page Networking via MPI ………………
Aug CMSC 104, LECT-021 Machine Architecture Some material in this presentation is borrowed form Adrian Ilie From The UNIVERSITY of NORTH CAROLINA.
CENTUM CS 3000 R3.04 PROFIBUS Interface Module
Date: File:PRO1_18E.1 SIMATIC S7 Siemens AG All rights reserved. Information and Training Center Knowledge for Automation Appendix: Technical.
CIS250 OPERATING SYSTEMS Chapter One Introduction.
The SIMATIC S7 System Family
Computer Systems Unit 2. Download the unit specification from moodle or the BTEC website Or alternatively visit ahmedictlecturer.wikispaces.com.
SIMATIC® S7系统家族 SIMATIC® PCS 7 NET Software HMI PC SIMATIC® WinCC DP
Automation and Drives A&D AS SM6, Page 1 SIMATIC S7-300 Workshop to promote the S7-300 automation platform.
1 Copyright by PROFIBUS Center Nederland
Programmable Logic Controller (PLC) - Hardware and Software Lecture 12.
INTRODUCTION TO COMPUTERS. A computer system is an electronic device used to input data, process data, store data for later use and produce output in.
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
Redundant network topologies for dependable time transfer
Fault Tolerance Comparison
PROFIDrive PROFISafe.
Siemens Step 7 Project with Controllere in 7 Steps: Step 1
Presentation transcript:

SIMATIC S7 Software Redundancy

SW Redundancy Principle Positioning Application Fields Configuration Features Order number and delivery form REDUNDANCY Area Steam Production Boiler 1 Mixer Boiler 2 Dryer

SW Redundancy Positioning Low Cost / Low Performance Redundancy solution based on standard components Universal solution for all CPU from CPU 315-2DP until CPU 417-4 Marketing parallel to S7-400H Principle Positioning Application Fields Configuration Features Order number and delivery form

SW Redundancy Application Fields Application for processes that tolerate a Master-Slave switchover time of about a second Examples: Water treatment Control of cooling systems Control and monitoring of temperature levels Traffic control Measuring registration Principle Positioning Application Fields Configuration Features Order number and delivery form

SW Redundancy with S7-400 Configuration Principle Redundant Area Non redundant MPI/ Profibus/ Ethernet Redundancy Connection Master controller Back up Area ET 200M with IM 153-2 Active Bus Backup Bus Positioning Application Fields Configuration Features Order number and delivery form

Profibus DP Redundancy with Standard IM 153-2 ET 200M with active Bus modules L+ Redundant IM 153-2 Principle Positioning Application Fields Configuration Features Order number and delivery form IM Bus module (BM) Active Bus module Available as individual components IM: 6ES7 153-2AA02-0XB0 BM: 6ES7 195-7HD00-0XA0 or as Bundle (2 x IM + 1 BM) 6ES7 153-2AR00-0XA0

SW Redundancy Function Principle Master Reserve Positioning Reading of Inputs Reading of Inputs Application Fields Configuration Non redundant user program processing Non redundant user program processing Features Order number and delivery form Reception of status information from reserve controller Reception of information from master controller Redundant user program processing Transmission of redundant data to reserve controller Transmission of information to the master controller Writing of non redundant and redundant outputs Writing of non redundant outputs

SW Redundancy with S7-400 Redundant area Principle Positioning MPI/ PROFIBUS/ Ethernet Application Fields Redundancy Connection Configuration Features Master controller Back up controller Order number and delivery form Redundant area

SW Redundanz with S7-300,-400 and OP7/17 Principle Redundant area Profibus/ Ethernet Master controller Back up Non redundant area OP7/17 PROFIBUS/MPI Positioning Application Fields Configuration Features Order number and delivery form

SW Redundancy with S7-300,-400 and OP7/17 Principle Positioning Redundant area Master controller Back up Non redundant area OP37 PROFIBUS/MPI Application Fields Configuration Features Order number and delivery form

SW Redundancy with S7-400 and WinCC Redundanzbereich PROFIBUS/MPI/Ethernet Master controller Back up Non redundant area WinCC Redundancy script Redundant area Principle Positioning Application Fields Configuration Features Order number and delivery form

SW Redundancy Connection to WinCC WinCC Script for Master-Backup switching (manual or automatic) Diagnostic Information AS1 or 2 is master Status AS-AS communication Status DP-slaves Principle Positioning WinCC Var 1 Var 2 . Var n Application Fields Configuration Features Order number and delivery form V1 V2 V3 V4 AS 1 AS 2 Redundanzbereich

SW Redundancy with single PROFIBUS Principle Positioning MPI/PROFIBUS/ Ethernet Master controller Back up Application Fields Configuration Features Order number and delivery form

SW Redundancy with redundant Ringbus Principle MPI/PROFIBUS/ Ethernet Master controller Back up OLM Positioning Application Fields Configuration Features Order number and delivery form

SW Redundanz with Multi Redundancy Principle Back up controller Redundant area Non redundant area Positioning Application Fields Configuration Features Order number and delivery form

SW Redundancy Features Master slave switchover time dependant on: CPU-Type number of I/O and number of DP-slaves volume of data to be transfered communication device Example with 2 CPU 414-2 DP, 4 DP-Slaves, 4 kBytes Data, communication throught Profibus Data transfer time appr. 1 s DP-Slave swithover appr. 20 ms Fault detection time appr. 100ms Sum appr. 1,1 s Principle Positioning Application Fields Configuration Features Order number and delivery form

SW Redundancy Features Switchover procedure Outputs are beeing frozen during the switchover After the switchover, the transfered data are used Switchover reasons Master failure (Power off or CPU-STOP) Failure of the Profibus-DP of the master controller Manual switchover Memory requirement is 10 kBytes STEP7 V 4.02 is required Principle Positioning Application Fields Configuration Features Order number and delivery form

SW Redundancy Ordering Information Order Number: 6ES7 862-0AC00 -0YA0 single licence for one redundant System (two CPU) 6ES7 862-0AC00 -0YA1 copy license for additional Systems delivery form CD-ROM with electronic documentation in 5 languages as help and PDF-file and 3 application examples Principle Positioning Application Fields Configuration Features Order number and delivery form

SIMATIC S7 Software-Redundancy