Oscilloscope Tutorial

Slides:



Advertisements
Similar presentations
An Electronic System Power Supply Example
Advertisements

Voltage and Its Measurements
Measurement of Voltages and Currents
This lesson covers the following outcomes Unit 54 P1, P7, P8 Unit 6 P10, P11.
Introduction 1st semester King Saud University
Introduction to electronics lab ENGRI 1810 Using: Solderless prototype board (white board) Digital multimeter (DMM) Power Supply Signal Generator Oscilloscope.
Sine waves The sinusoidal waveform (sine wave) is the fundamental alternating current (ac) and alternating voltage waveform. Electrical sine waves are.
Medical Oscilloscopes. Cathode ray oscilloscope (CRO) basics: –Many measurement are made easier by the CRO because it will display not only amplitude,
1.3c Current Electricity Alternating Currents Breithaupt pages 74 to 79 November 14 th, 2010.
OSCILLOSCOPES Introduction The Cathode-Ray Tube
BASICS OF LAB SCOPES. Scope Essentials Digital Storage Oscilliscope (DSO) Voltmeter that captures voltage samples & displays them on a screen Voltage.
PRINCIPLES OF MEASUREMENT AND INSTRUMENTATION EKT 112
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
Introduction What is an oscilloscope?.
Fluke Oscilloscope 4 Isolated Channels 200 Mhz Bandwidth CAT III 1000 CAT IV 600 Rated 2.5 GS/s sample rate Connect-and-View™ IP-51 Rated.
The Oscilloscope: Basic Features & Functions  Source –Determines which signal is compared to the trigger settings.  Level –Determines where on the edge.
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
Electric Curcuits and Measurements Basic Electrical components and their functions Measurements of electrical circuits characteristics - Multimeter - Oscilloscope.
POWER SUPPILES LECTURE 20.
A Company Selling Technology and not just a Product.
 Distortion – the alteration of the original shape of a waveform.  Function of distortion analyzer: measuring the extent of distortion (the o/p differs.
 Popular instrument to show time, voltage both DC and AC. Shows Volts / Time.  Display waveforms. Spectrum scope shows volts to Frequency  Cathode (-ve.
The Oscilloscope shows voltage, Waveforms, & Phase shifts
Institute Of Applied Technology ATE 1012 Grade 10 Eng. Rose Hasan.
CHAPTER 9 Oscilloscopes and Graphing Multimeters
Waveform 2.1 Basic Digital Waveforms 2 Measurement Paul Godin Updated October 2009.
Measurement Systems in Electronics University of Pitesti Dolnośląska Wyższa Szkoła Przedsiębiorczości i Techniki w Polkowicach Dobrica Adrian Dr inż. ZDZISŁAW.
Laboratory Equipment 1 st semester King Saud University College of Applied studies and Community Service 1302CT By: Nour Alhariqi.
EE 211 Lecture 1 Thomas H. Ortmeyer January 13, 2006 Clarkson University.
Oscilloscope Muhajir Ab. Rahim School of Mechatronic Engineering
Vertical deflection system: * The function of the deflection system provides an amplified signal of the proper level to derive the vertical deflection.
Scopes  An oscilloscope is a visual voltmeter.  An oscilloscope converts electrical signals into a visual image representing voltage changes over a.
LAB SCOPES. HIGH SPEED VOLTMETER n Replaces: Test LightTest Light Digital Voltmeter/Ammeter/OhmmeterDigital Voltmeter/Ammeter/Ohmmeter Frequency MeterFrequency.
Introduction to the Oscilloscope
S.SESHA PHANINDHRA 12705A0425 II BTECH ECE-B
Capacitive transducer. We know that : C=kЄ° (A/d) Where : K=dielectric constant Є° =8.854 *10^-12 D=distance between the plates A=the area over lapping.
Velleman Oscilloscope: Windows 7 by Mr. David Fritz.
Lecture 5: DMM & Oscilloscope 1. DMM can be used to measure: DC & AC voltages – current - resistance - BJT (β test) - diode test - short circuit test,
1 Electrical Skills Voltage and Its Measurements.
In practice, it is often required to make or break an electric al circuit in many operations. In some applications, it is desirable that this make and.
Signal Analyzers. Introduction In the first 14 chapters we discussed measurement techniques in the time domain, that is, measurement of parameters that.
BASIC INSTRUMENTS - oscilloscopes
© 2011 Pearson Education, Inc. All Rights Reserved Automotive Technology, Fifth Edition James Halderman OSCILLOSCOPES AND GRAPHING MULTIMETERS 43.
Physics Section 12.3 Apply the properties of sound resonance Recall: A standing wave is the result of the superposition of a wave and its reflection from.
AMMETER  An ammeter is a measuring instrument used to measure the current in a circuit. Electric currents are measured in amperes (A), hence the name.
Chapter 9 CAPACITOR.
The Function Generator and the Oscilloscope Dr. Len Trombetta and Dr. Dave Shattuck 1 ECE 2100.
Measurement and Instrumentation
Oscilloscopes. Objectives –After completing this chapter, the student should be able to: Explain the function of an oscilloscope. Identify the basic parts.
FUNCTION GENERATOR.
Crashcourse Oscilloscope and Logic Analyzer By Christoph Zimmermann.
Introduction To Oscilloscopes. What is an Oscilloscope The oscilloscope is basically a graph-displaying device that draws a graph of an electrical signal.
Residential Cabling Technologies Copyright © 2005 Heathkit Company, Inc. All Rights Reserved Electrical Measurements.
Mrs V.S.KharoteChavan,E&Tc,PC poly
ELECTRONIC DEVICES AND CIRCUITS
(5) DMM & Oscilloscope.
Oscilloscope.
Oscilloscopes and Graphing Multimeters
Harmonic Distortion Analyzer, Wave Analyzer and Function Generator
Introduction What is an oscilloscope?.
INTRODUCTION PRESENTATION: OSCILLOSCOPE..
FIGURE 9-1 (a) On an analog scope, the voltage measured at the throttle position signal wire is displayed on a horizontal line at about 0.5 volt. (b) As.
electronics fundamentals
Electronics Fundamentals
ELECTRONICS II 3rd SEMESTER ELECTRICAL
Lab 8 Induction to Oscilloscope
FIGURE 9-1a On an analog scope, the voltage measured at the throttle position signal wire is displayed on a horizontal line at about 0.5 volt.
Oscilloscopes and Graphing Multimeters
Automotive Technology Principles, Diagnosis, and Service
Introduction to the Oscilloscope Engr. Annalyn soria Lecturer.
Presentation transcript:

Oscilloscope Tutorial The oscilloscope is basically a graph-displaying device It draws a graph of an electrical signal. In most applications the graph shows how signals change over time: the vertical (Y) axis represents voltage the horizontal (X) axis represents time.

Oscilloscopes Horizontal sweeps at a constant rate. Vertical plates are attached to an external voltage, the signal you attach to the scope.

Cathode Ray Tubes Variation in potential difference (voltage) placed on plates causes electron beam to bend different amounts. “Sweep” refers to refreshing repeatedly at a fixed rate.

Scope (Con’t) This simple graph can tell you many things about a signal: You can determine the time and voltage values of a signal. You can calculate the frequency of an oscillating signal. You can see the "moving parts" of a circuit represented by the signal. You can tell if a malfunctioning component is distorting the signal. You can find out how much of a signal is direct current (DC) or alternating current (AC). You can tell how much of the signal is noise and whether the noise is changing with time.

How does an Analog Scope work?

How does a Digital Scope work?

Triggering Stabilizes a Repeating Waveform

Waveform shapes tell you a great deal about a signal

If a signal repeats, it has a frequency If a signal repeats, it has a frequency. The frequency is measured in Hertz (Hz) and equals the number of times the signal repeats itself in one second

Voltage, Current, & Phase

Performance Terms Bandwidth The bandwidth specification tells you the frequency range the oscilloscope accurately measures. Rise Time Rise time may be a more appropriate performance consideration when you expect to measure pulses and steps. An oscilloscope cannot accurately display pulses with rise times faster than the specified rise time of the oscilloscope. Vertical Sensitivity The vertical sensitivity indicates how much the vertical amplifier can amplify a weak signal. Vertical sensitivity is usually given in millivolts (mV) per division. Sweep Speed For analog oscilloscopes, this specification indicates how fast the trace can sweep across the screen, allowing you to see fine details. The fastest sweep speed of an oscilloscope is usually given in nanoseconds/div. Gain Accuracy The gain accuracy indicates how accurately the vertical system attenuates or amplifies a signal. Time Base or Horizontal Accuracy The time base or horizontal accuracy indicates how accurately the horizontal system displays the timing of a signal. Sample Rate On digital oscilloscopes, the sampling rate indicates how many samples per second the ADC can acquire. Maximum sample rates are usually given in megasamples per second (MS/s). The faster the oscilloscope can sample, the more accurately it can represent fine details in a fast signal.. ADC Resolution (Or Vertical Resolution) The resolution, in bits, of the ADC indicates how precisely it can turn input voltages into digital values. Record Length The record length of a digital oscilloscope indicates how many waveform points the oscilloscope is able to acquire for one waveform record.

Grounding Proper grounding is an important step when setting up to take measurements. Properly grounding the oscilloscope protects you from a hazardous shock and protects your circuits from damage. Grounding the oscilloscope is necessary for safety. If a high voltage contacts the case of an ungrounded oscilloscope, any part of the case, including knobs that appear insulated, it can give you a shock. However, with a properly grounded oscilloscope, the current travels through the grounding path to earth ground rather than through you to earth ground. To ground the oscilloscope means to connect it to an electrically neutral reference point (such as earth ground). Ground your oscilloscope by plugging its three-pronged power cord into an outlet grounded to earth ground. Grounding is also necessary for taking accurate measurements with your oscilloscope. The oscilloscope needs to share the same ground as any circuits you are testing. Some oscilloscopes do not require the separate connection to earth ground. These oscilloscopes have insulated cases and controls, which keeps any possible shock hazard away from the user.

Scope Probes Most passive probes have some degree of attenuation factor, such as 10X, 100X, and so on. By convention, attenuation factors, such as for the 10X attenuator probe, have the X after the factor. In contrast, magnification factors like X10 have the X first

Position and Volts per Division Vertical Controls Position and Volts per Division The vertical position control lets you move the waveform up or down to exactly where you want it on the screen. The volts per division (usually written volts/div) setting varies the size of the waveform on the screen. A good general purpose oscilloscope can accurately display signal levels from about 4 millivolts to 40 volts. Often the volts/div scale has either a variable gain or a fine gain control for scaling a displayed signal to a certain number of divisions.

Input Coupling Coupling means the method used to connect an electrical signal from one circuit to another.

Position and Seconds per Division Horizontal Controls Position and Seconds per Division The horizontal position control moves the waveform from left and right to exactly where you want it on the screen. The seconds per division (usually written as sec/div) setting lets you select the rate at which the waveform is drawn across the screen (also known as the time base setting or sweep speed). This setting is a scale factor. For example, if the setting is 1 ms, each horizontal division represents 1 ms and the total screen width represents 10 ms (ten divisions). Changing the sec/div setting lets you look at longer or shorter time intervals of the input signal.

Trigger Position The trigger position control may be located in the horizontal control section of your oscilloscope. It actually represents "the horizontal position of the trigger in the waveform record." Horizontal trigger position control is only available on digital oscilloscopes. Varying the horizontal trigger position allows you to capture what a signal did before a trigger event (called pretrigger viewing). Digital oscilloscopes can provide pretrigger viewing because they constantly process the input signal whether a trigger has been received or not. A steady stream of data flows through the oscilloscope; the trigger merely tells the oscilloscope to save the present data in memory. I n contrast, analog oscilloscopes only display the signal after receiving the trigger.

Trigger Controls (con’t)

Pulse and Rise Time Measurements

Multimeter tutorial A meter is a measuring instrument. An ammeter measures current, a voltmeter measures the potential difference (voltage) between two points, and an ohmmeter measures resistance. A multimeter combines these functions, and possibly some additional ones as well, into a single instrument.

To measure current, the circuit must be broken to allow the ammeter to be connected in series Ammeters must have a LOW resistance

To measure potential difference (voltage), the circuit is not changed: the voltmeter is connected in parallel Voltmeters must have a HIGH resistance

To measure resistance, the component must be removed from the circuit altogether Ohmmeters work by passing a current through the component being tested

Digital Multimeters Digital meters give an output in numbers, usually on a liquid crystal display. Most modern multimeters are digital and traditional analogue types are destined to become obsolete. Digital multimeters come in a wide range of sizes and capability. Everything from simple 3 ½ digit auto ranging pocket meters to larger 8 ½ digit bench model with operator or computer (IEEE488 compatible) settable range selection

An electronic instrument that generates various waveforms such as Function Generator An electronic instrument that generates various waveforms such as Sine wave Square wave Pulse trains Sawtooth The amplitude, DC offset, frequency are adjustable.

Function Generators (con’t) Like multimeters there is a wide variety of device offering various Amplitude characteristics Bandwidth Adjustments of rise and fall times Modulation capability (AM, FM, Pulse, etc.)

Power Supply This is the device that transfers electric power from a source to a load using electronic circuits. Typical application of power supplies is to convert utility's AC input power to a regulated voltage(s) required for electronic equipment. Depending on the mode of operation of power semiconductors PS can be linear or switching. In a switched-mode power supply, or SMPS power handling electronic components are continuously switching on and off with high frequency in order to provide the transfer of electric energy. By varying duty cycle, frequency or a phase of these transitions an output parameter (such as output voltage) is controlled. Typical frequency range of SMPS is from 20 kHz to several MHz.

Parameters that are Power Supply specific include: Power Supply (con’t) Power supplies like many of the other electronic instruments, come in many varieties with a wide range of capabilities: Parameters that are Power Supply specific include: Voltage levels Current Regulation Protection Output impedance Noise (ripple) It’s the designer (or researcher) responsibility to identify the characteristics required.

Oscilloscope

Oscilloscope(continue) DEMO…….Lab3a