Electron Probe Microanalysis EPMA Wavelength Dispersive Spectrometry (WDS) I UW- Madison Geoscience 777 Revised 2-25-2013.

Slides:



Advertisements
Similar presentations
NUCP 2371 Radiation Measurements II
Advertisements

Geiger-Muller detector and Ionization chamber
WDS (Wavelength Dispersive Spectrometry):
Chapter 8 Planar Scintigaraphy
Radiation Detectors / Particle Detectors
Internal – External Order We described symmetry of crystal habit (32 point groups) We also looked at internal ordering of atoms in 3-D structure (230 space.
X-Ray Crystallography The most important technique for mineralogy The most important technique for mineralogy Direct measurement of atomic arrangement.
AMCF Materials Characterization School 2012 X-Ray Photoelectron Spectroscopy Tim Morgan.
Physics 6C Interference of EM Waves Prepared by Vince Zaccone For Campus Learning Assistance Services at UCSB.
Quantum Mechanics 102 Tunneling and its Applications.
Properties of Multilayer Optics An Investigation of Methods of Polarization Analysis for the ICS Experiment at UCLA 8/4/04 Oliver Williams.
CHAPTER 8 (Chapter 11 in text) Characterization of Nanomaterials.
The Origins of X-Rays. The X-Ray Spectrum The X-Ray Spectrum (Changes in Voltage) The characteristic lines are a result of electrons ejecting orbital.
ED and WD X-ray Analysis
Those Interfering Signals Modes and Dispersion in Fibers.
Physics 6C Interference of EM Waves Prepared by Vince Zaccone For Campus Learning Assistance Services at UCSB.
Interference Diffraction and Lasers
Types of Analyses Single Collector –Uses only one collector or detector –This is the case with a Daly or EM Advantages: –Need only one detector –Peaks.
Electron Probe Microanalysis EPMA
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
X - Rays & Crystals Characterizing Mineral Chemistry & Structure J.D. Price Characterizing Mineral Chemistry & Structure J.D. Price.
Chapter 8 – Mass Spectrometry. Mass Spectrometry The mass spectrometer can be used for: – Quantitative analysis – as a sophisticated and very sensitive.
Photon detection Visible or near-visible wavelengths
Reflection and Refraction of Light
Chapter 12 Atomic X-Ray Spectroscopy
EDS Energy Dispersive Spectroscopy
Scanning Electron Microscope (SEM)
X-Ray Diffraction Dr. T. Ramlochan March 2010.
PHYS 430/603 material Laszlo Takacs UMBC Department of Physics
Energy-Dispersive X-ray Microanalysis in the TEM Anthony J. Garratt-Reed Neil Rowlands.
Other modes associated with SEM: EBIC
Diffraction is the bending of waves around obstacles or the edges of an opening. Huygen’s Principle - Every point on a wave front acts as a source of tiny.
Reminders for this week Homework #4 Due Wednesday (5/20) Lithography Lab Due Thursday (5/21) Quiz #3 on Thursday (5/21) – In Classroom –Covers Lithography,
Ch 16 Interference. Diffraction is the bending of waves around obstacles or the edges of an opening. Huygen’s Principle - Every point on a wave front.
Ionization Detectors Basic operation
Lecture 24 Interference of Light.
Wave Optics.
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
Light Waves.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
e- beam 2D sample e- beam 3D
Electron probe microanalysis Low Voltage SEM Operation Modified 9/23/10.
Even a single slit causes a diffraction pattern, because every point in the slit serves as a source of a wave. Different parts of the slit have different.
Physics 11 Advanced Mr. Jean May 23 rd, The plan: Video clip of the day Wave Interference patterns Index of refraction Slit & Double Slit interference.
X-ray microanalysis in the electron microscope
Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis.
Interference and Diffraction
X-ray absorption spectroscopy (XAS)
The Significance of Refractive Index “K” Values LSMs, or, Why Long Wavelength Peak Markers Don’t Line Up Correctly John Fournelle* and K. Bolger*, J. Cook*,
Chapter V Radiation Detectors.
Analysis of Fluorine in Fe-bearing phases: Problems and solutions John Fournelle Eugene Cameron Electron Microprobe Lab Department of Geology & Geophysics.
Holt Physics Chapter 12 Waves Periodic Motion A repeated motion that is back and forth over the same path.
Thin-Film Interference Summary
Electron Probe Microanalysis EPMA
Electron probe microanalysis EPMA
Interference of Light Waves
What is XPS? XPS (x-ray photoelectron spectroscopy) is also known as ESCA (electron spectroscopy for chemical analysis). XPS provides chemical information.
Interference of EM Waves
Electron Probe Microanalysis EPMA
Radiation Detectors : Detection actually means measurement of the radiation with its energy content and other related properties. The detection system.
Electron probe microanalysis EPMA
Preface: What’s EPMA all about? How does Geology 777 work?
Electron Probe Microanalysis EPMA
Electron probe microanalysis EPMA
Interference of Light Waves
Electron Probe Microanalysis EPMA
Electron Probe Microanalysis EPMA
X-ray detectors single photon detectors
Electron probe microanalysis
Presentation transcript:

Electron Probe Microanalysis EPMA Wavelength Dispersive Spectrometry (WDS) I UW- Madison Geoscience 777 Revised

Generic EMP/SEM Electron gun Column/ Electron optics Optical microscope WDS spectrometers Scanning coils EDS detector Vacuum pumps SE,BSE detectors Faraday current measurement UW- Madison Geology 777

Key points X-rays are dispersed by crystal with only one wavelength (n ) reflected (=diffracted), with only one wavelength (n ) passed to the detector Detector is a gas-filled (sealed or flow-through) tube where gas is ionized by X-rays, yielding a massive multiplication factor ( ‘ proportional counter ’ ) X-ray focusing assumes geometry known as the Rowland Circle Key features of WDS are high spectral resolution and low detection limits UW- Madison Geology 777

Spectrometers An electron microprobe generally has 3-5 spectrometers, with 1-4 crystals in each. Here, SP4 (spectro #4) of our SX51 (#485) with its cover off. Crystals (2 pairs) Proportional Counting Tube (note tubing for gas) PreAmp UW- Madison Geology 777

X-ray path Only a small % of X-rays reach the spectrometer. They first must pass thru small holes (~10-15 mm dia; red arrows) in the top of the chamber (above, looking straight up), then thru the column windows (below, SP4).Thus, in our EMP, there are different vacuum regimes in the chamber vs the spectrometer, separated by the windows (not in JEOLs). BSE detectors alternate Crystal UW- Madison Geology 777

Wavelength Dispersion Of the small % of X-rays that reach the crystal, only those that satisfy Braggs Law will be diffracted out of the crystal. Note that exact fractions of will satisfy the conditions for defraction. Thus, there is a possibility of “ higher order ” (n=2,3,...11,?) interference in WDS (but there also is the means electronically to discriminate against the interference). n = 2d sin  BA ’ = A ’ C = d sin  for constructive reinforcement of a wave, the distance BA ’ must be one half the wavelength. Thus, 2d sin  =  and by similar geometric construction = n UW- Madison Geology 777

What is n  ? This is sometimes difficult to comprehend. Assume you have your spectrometer set to one particular position, which means for that sin  and that 2d (let ’ s say they = 12 Å), there are several possible signals that the spectrometer can tune in to at that position: (1) an x-ray with wavelength of 12 Å, (2) an x-ray of 6 Å, (3) an x-ray of 4 Å, (4) an x-ray of 3 Å, etc --of course, if and only if such x-rays are being generated in the sample. n = 2d sin  BA ’ = A ’ C = d sin  for constructive reinforcement of a wave, the distance BA ’ must be one half the wavelength. Thus, 2d sin  = and by similar geometric construction = n UW- Madison Geology 777

Lots of Crystals Over the course of the first 30 years of EPMA, ~50 crystals and pseudocrystals have been used. UW- Madison Geology 777

Crystals and PC/LSMs Consider the order of 2d in Braggs Law: sin  varies from.2-.8, and varies over a wide range from hundreds to fractions of an Å. Thus, we need diffractors that cover a similiar range of 2d, from around 1 Å to hundreds of Å. In our SX51, we utilize TAP, PET and LIF crystals for the shorter wavelengths. For longer wavelengths, there are 2 options: pseudocrystals (PCs), produced by repeated dipping of a substrate in water upon which a monolayer (~soap film) floats,progressively adding layer upon layer, or layered synthetic microstructures (LSMs; also LDEs, layered diffracting elements), produced by sputtering of alternating light and heavy elements, such as W and Si, or Ni and C. Both these are periodic structures that diffract X-rays. The LSMs yield much higher count rates; however, peaks are much broader, which have good/bad consequences, discussed later. In reality, people interchange the words PC, LSM, LDE, etc. Cameca uses PC and JEOL uses LDE, for same things. UW- Madison Geology 777

Crystals and PCs on the UW SX51 There is a more precise form of Braggs Law, that takes into account refraction, which is more pronounced in the layered synthetic diffractors, n = 2d sin  (1-k/n 2 ) k is refraction factor, n is order of diffraction UW- Madison Geology 777

Pseudocrystals/LSMs Goldstein et al, p. 280

Crystals and PCs: Which to use? The EPMA user may have some control over which crystal to use; some element lines can be detected by either of 2 crystals (e.g. Si Ka by PET or TAP, V Ka by PET or LIF), whereas other elements can only be detected by one (e.g. S Ka by PET). Each probe has its own (unique?) set of crystals and the user has to work out the optimal configuration, taking into account concerns such as time and money (spread the elements out) interferences vs counting statistics (sharper peaks usually have lower count rates) stability (thermal coefficient of expansion) UW- Madison Geology 777

ÅÅ Crystal comparison TAP PC0 -Low counts -Good resolution -High counts -Poor resolution Gopon et al UW- Madison Geology 777

Full Width Half Max Si K  on TAP sin  = P/B= 4862/40=122 FWHM=0.038Å Å 4862 cts 2431 cts Max Half max Full Width Peak (spectral) resolution is described by FWHM counts UW- Madison Geology 777

Crystal comparison The class project in 2002 was to collect data to compare the efficiency of different crystals/ PCs for certain elements. Si K  on TAP sin  = P/B= 4862/40=12 FWHM=0.038Å Si K  on PET sin  = P/B= 207/1.3=159 FWHM=0.006Å ÅÅ TAP gives a higher count rate, and wider peak for Si K  vs. using PET Acquiring accurate Si Ka counts is critical for geological EPMA. Always use TAP! (with rare exceptions) as the the wider peak (6x wider, see FWHM) is less sensitive to chemical peak shifts in silicates (and higher count rate is a plus) UW- Madison Geology 777

WDS detector P10 gas (90% Ar - 10% CH 4 ) is commonly used as an ionization medium. The X-ray enters through the thin window and 3 things can occur: (1) the X-ray may pass thru the gas unabsorbed (esp for high keV X-rays); (2) it may produce a trail of ion pairs (Ar + + e), with number of pairs proportional to the X-ray energy; and (3) if the X-ray is >3206 eV it can knock out an Ar K electron, with L shell electron falling in its place. There are also 2 possibilities that can result from this new photon: (3a) internal conversion of the excess energy with emission of Auger electron (which can produce Ar + + e pairs); or (bc) the Ar Ka X-ray can escape out thru a window, reducing the number of Ar + + e pairs by that amount of energy (2958 eV)-->creating an Ar-esc. peak UW- Madison Geology 777

Detector amplification Nominally, it takes 16 eV to produce one Ar + - electron pair, but the real (effective) value is 28 eV. For Mn Ka (2895 eV), 210 ion pairs are initially created per X-ray. However, there is a multiplier effect (Townsend avalanching). For our example of Mn Ka, all 210 electrons are accelerated toward the center anode (which has a positive voltage [bias] of v) and produces many secondary ionizations. This yields a very large amplification factor (~10 5 ), and has a large dynamic range (0- 50,000 counts/sec). UW- Madison Geology 777

Detector windows Thin (polypropylene) windows are used for light X-rays (e.g. those detected by TAP and PC crystals). Since the windows are thin, the gas pressure must be low (~0.1 atm). And being thin windows, some of the gas molecules can diffuse out through them -- so the gas is replenished by having a constant flow. For thicker windows (mylar), 1 atm gas pressure is used (with higher counts resulting). Sealed detectors with higher pressure gas (e.g. Xe) are also used by some. (I want one!) UW- Madison Geology 777

WDS detector The bias on the anode in the gas proportional counter tube needs to be adjusted to be in the proportional range. Too high bias can produce a Geiger counter effect. Too low produces no amplification. UW- Madison Geology 777

WDS pulse processing Goldstein et al Fig The small electron pulses (charges) generated in the tube are first amplified in the pre-amp (top) located just outside the vacuum on the outside of the spectrometer, then sent to the PHA board where they are amplified (center) and shaped (bottom). Each figure is for one (the same) pulse. UW- Madison Geology 777

Ar-escape peak There is a probability that a small number of Ar Ka X-rays produced by the incident X-ray (here, Fe Ka) will escape out of the counting tube. If this happens, then those affected Fe Ka X-rays will have pulses deficient by 2958 eV. Fig 7.8 is an unusual plot of this (for teaching purposes); what is normally seen is the Pulse Height distribution where the pulses are plotted on an X-axis of a maximum of 5 or 10 volts. Reed, 1993, p. 90 UW- Madison Geology 777

Actual PHA plot for Fe K  : note the Ar- escape peak UW- Madison Geology 777

Actual PHA plot for Si K  : there is no Ar- escape peak. WHY? UW- Madison Geology 777

Higher order reflections Recall n = 2d sin . Higher order reflections are possible in your specimens, and must be avoided to prevent errors in your analyses. Reed (1993) reports that LIF can show a strong second order peak, up to 10% of the first order peak. In 1999, the 777 class examined the higher order reflections of Cr Ka lines. On PET, 2nd and 3rd order peaks were present, and decreased ~an order of magnitude with increasing n. UW- Madison Geology 777

On TAP, up to the 8th order peak was present. Here, the intensity of the odd numbered orders was less than the following even order, e.g. the 5th order Ka had 30% fewer counts than the 6th order line. Differential mode of pulse height analysis (PHA) may be used to ignore counting higher order X-rays. n counts

Pulse Height Analysis If a higher order reflection falls upon a peak (or unavoidable background) position, the analyst has the option of using Pulse Height Analysis, i.e. setting up a window and not counting any X- rays that have energies greater than the window ’ s upper limit. There is a lower limit (baseline, usually 0.5 volts). The window stretches above it (here 4 volts), and thus a second order reflection should have a pulse height around 6 volts, and would not be counted. There are some situations where operation in differential mode can introduce errors (pulse height depression), so the normal mode is integral. And if differential is used, it is good to do some tests first to get a feeling of how comprehensive its filtering action is. window baseline UW- Madison Geology 777

Integral vs Differential PHA Goldstein et al, p Analysis of ‘ light elements ’ such as C is complicated because of the long wavelength (44 Å) which means that higher order reflections of many elements can interfere. At top, where the PHA is set to the “ count everything ” integral mode, the 3rd order reflection of Ni L  1 falls very close to C K  and adds some to C peak counts. Note also the 2 and 3 order Fe L lines. By setting the detector electronics to the discrimination mode (differential), bottom, the higher order lines are strongly (but not totally) suppressed. Spectrometer scans UW- Madison Geology 777

Putting it all together: Spectrometer = Crystal + Detector moving in a highly choreographed dance Dance floor =Rowland Circle UW- Madison Geology 777

Rowland Circle For most efficient detection of X-rays, 3 points must lie upon the focusing circle known as the Rowland Circle. These points are the beam impact point on the sample (A), the active central region of the crystal (B), and the detector -- gas-flow proportional counter (C). A C B UW- Madison Geology 777

Rowland Circle The loci of 3 points must always lie on the Rowland Circle. Starting at the top position (blue), there is a shallow angle of the X-ray beam with the analyzing crystal. To be able to defract a longer wavelength X-ray on the same spectrometer, the crystal travels a distance further out, and effectively the (green) Rowland Circle “ rolls ”, pinned by the beam- specimen interaction point. UW- Madison Geology 777