CEDAR MECHANICS Liverpool Conceptual Design (Subject to funding from STFC) 1 CEDAR Mechanics Conceptual Design.

Slides:



Advertisements
Similar presentations
Detail Discussion on Different type of Circuit Breaker
Advertisements

Dr. Ruth Collins TrinityHaus
Tritium Target 9 December Overview Design and major subsystems Thermal/structural analysis Cell filling Vent and stack T2 detection and monitoring.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
4-1 Chapter 4 Overview b The DCM is very complex Mechanical, electrical, hydraulic and safety systems all work together Mechanical, electrical, hydraulic.
31/03/11FV 1 CEDAR from flammable gas safety point of view.
HFT PXL Mechanical WBS 1.2 March 2010 Howard Wieman LBNL 1.
AMS-02 Cryosystem Phase III Flight Safety Review January 12, 2010 Phil Mott.
CEDAR MECHANICS Liverpool Conceptual Design (Subject to funding from STFC) 1 CEDAR Mechanics Conceptual Design.
MERIT Hg System Final Design Review Hg Target System Design Interfaces V.B. Graves P.T. Spampinato T.A. Gabriel MERIT Collaboration Meeting MIT Plasma.
18th March Richard Hawkings Humidity control in the ATLAS ID Richard Hawkings (CERN) JCOV meeting 18/3/04  Overview of humidity and associated gas.
Global Design Effort Detector concept # Plenary introductory talk IRENG07 Name September 17, 2007.
Safety Review: RF Issues Derun Li Absorber Safety Review December 9-10, 2003 Lawrence Berkeley National Laboratory Berkeley, CA
11/26/2002Edgar L Black IIT MICE Video Conference November 27, 2002 Summary of safety implementation for proposal.
1 Superconducting Magnets for the MICE Channel Michael A. Green Oxford University Physics Department Oxford OX1-3RH, UK.
MICE Hydrogen System Implementation Tom Bradshaw Elwyn Baynham Iouri Ivaniouchenkov Jim Rochford.
MICE RFCC Module Update Allan DeMello Lawrence Berkeley National Lab MICE CM26 at Riverside California March 26, 2010.
Cooling Update (May 2011) Tim. Overview From last time – Estimate Power Loads Active components Extraneous heat sources – Develop methodology for exploring.
MICE hydrogen review System modifications. Relief circuit repair During leak testing of R&D tests, the insulating vacuum would not go lower than
Patrick Thornton, SNS/FPE June 9, 2008
Control of Particulate Matter from a Sabatier Catalyst Bed HSL 126 Loel Goldblatt, Hamilton Sundstrand Space Systems International, Inc. Karen Murdoch,
Iouri Ivaniouchenkov RAL Safety considerations at RAL July 9, RAL MICE Collaboration Meeting 1.
CEDAR Support Structure and PMT Test Peter Sutcliffe 13 th July 2011 CERN via EVO.
Cooling: CEDAR PMT & Electronics Tim Jones Liverpool Group.
Part 2: Buildings as a System Lee F. Ball Jr., PhD
Installation. Indoor Unit Installation Typical Installation.
Dec. 4, 2001 CERN-1 Hans de Vries VELO Mechanics  RF/vacuum foil  Rectangular bellow  Wake field suppressors  Cabling Summary & Outlook VELO mechanical.
Pixel Support Tube Requirements and Interfaces M.Olcese PST CDR: CERN Oct. 17th 2001.
26 April 2013 Immanuel Gfall (HEPHY Vienna) Belle II SVD Overview.
Ron Madaras, LBL U.S. Pixel Meeting, SCIPP, July 9-10, 2003 Patch Panel 1 (PP1) Brief Review Cost and Effort Estimate.
Design Progress Allen Ellis 18-September
Principles of correct VRV Installation A. Refrigerant pipe work
Conceptual Design Review of the NPDGamma Experiment in Beam Line 13 Seppo Penttila NPDGamma project manager September 25, 2007 at SNS.
- Overview about Malaysia oil and gas - level of realism to traditional drawing (2D dwg) - Be able to store huge amount of data referring. - Single source.
Beam Dump Upgrade Planning Keith Welch 2/5/13. Drivers for Upgrade Historical Problems – Hardware failures Helium system Windows, diffusers Dehumidifiers.
Safety Requirements and Regulations 10/3/20121Safety Requirements & Regulations James Sears.
January 25, 2005GRETINA 2004 Review1 GRETINA 2004 Annual Review Steve Virostek Lawrence Berkeley National Lab Mechanical System.
3.4.3 Student Book © 2004 Propane Education & Research CouncilPage Bulk Plant Emergency Shutdown Equipment and Periodic Examination Methods One.
CM1 Thermal Cycle CM1 Warmup –1/4/12 (Wed.) to 1/6/12 (Fri.) (~50 hours) –Verified turbo interlock system works CM1 Cooldown –Began 1/9/12 (Monday) –At.
CMS ECAL End Cap Meeting CERN 18 Oct to 22 Oct ECAL End Cap High Voltage and Fibre Optic Monitoring Systems Progress. Progress on High Voltage and.
International Conference on Hydrogen Safety 2011 – San Francisco, 12 Sept 2011 Risk informed separation distances for hydrogen refuelling stations Frederic.
CLAS12-RICH Mechanical Design Status-Report CLAS12 RICH Review September 5-6 th 2013 S. Tomassini, D. Orecchini1 D. Orecchini, S. Tomassini.
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
ECAL – EE Design Status Presentation 19/7/06 D.J.A. Cockerill - RAL 1 EE Design Status D Cockerill CERN 19 July 2006.
Summary of the second Hydrogen CEDAR Safety Meeting 24 November 2008 Present: J.Gulley/ SC-GS, A.Sharma/PH-FGSO, Augusto, Cristina, Lau, Niels.
CM27 – 8 th July 2010 LH2 System Progress and Future Plans M Hills T Bradshaw M Courthold I Mullacrane P Warburton.
M. Sannino for S. Cuneo - I.N.F.N. Genova1 Rich2 MAPMT Housing & Cooling Outdated designs and what is needed to get a final executive design Imperial College.
NEDM Collaboration Meeting 5/2008 Preliminary Engineering Report nEDM Central Detector John C. Ramsey Los Alamos National Laboratory.
SAFETY WITH CRYOGENIC SYSTEMS. Safety aspects 1. Physiological 2. Suitability of materials and construction 3. Explosions and flammability 4. Excessive.
Upgrade PO M. Tyndel, MIWG Review plans p1 Nov 1 st, CERN Module integration Review – Decision process  Information will be gathered for each concept.
The integration of 420 m detectors into the LHC
Installation of the T600 at Fermilab CSN2, September 22,
CEDAR MECHANICS Liverpool Conceptual Design (Subject to funding from STFC) 1 CEDAR Mechanics Conceptual Design.
Interface of FP420 to LHC FP420 meeting 28-Sep-2006.
KTAG Mechanics, Optics and Cooling Progress and Schedule NA62 CEDAR Meeting 26March20121.
 1) Introduction  2) GEANT simulations  3) NEW DESIGN : Technology and Assembly  4) Conclusions Reported by G.Feofilov, CBM meetings, Dubna.
CW Cryomodules for Project X Yuriy Orlov, Tom Nicol, and Tom Peterson Cryomodules for Project X, 14 June 2013Page 1.
Update on the ESS monolith design Rikard Linander Monolith and Handling Group ESS Target Division TAC 10, Lund, Nov 5,
RFQ coupler S. Kazakov 07/28/2015. Requirements: Coupler requirements Expected problems: Heating (loop, ceramic window, etc.) Multipactor Solutions: Appropriate.
Working group meeting 07/05/15. Agenda Overview of review and current action list Relief system – Summary of problem – Details of analysis, testing and.
Miscellaneous MEC Topics Mainz, CM September 2016, MEC Session J
Installation of the T600 at Fermilab
cooling and supports of the forward endcap EMC
Consolidation and Upgrade of the LHC Experimental Vacuum Systems
Cryomodule Assembly Plan
Overview of the TARGET Monolith Rough Vacuum
Risk Management Student Powerpoint
Presentation transcript:

CEDAR MECHANICS Liverpool Conceptual Design (Subject to funding from STFC) 1 CEDAR Mechanics Conceptual Design

Design Considerations - Mechanical NA62 will use the West CEDAR filled with hydrogen at 4 bar. High beam flux (50 MHz K + ) requires existing PMTs to be replaced with faster photo-detectors. A high-intensity muon halo, accompanied by low-energy neutrons, surrounds the beam. Simulations indicate that a radius of 20 – 50 cm minimises background. Conceptual design locates the photo-detectors at a radius of 35 cm and associated electronics within an envelope of radius 50 cm. The existing protective and thermally-insulated metal cover around the nose section of the CEDAR cannot be used. Thermal isolation to minimise temperature gradients is vital. Serious design effort is needed if cooled (200 K) PMs are used. CEDAR Mechanics Conceptual Design 2

Design Considerations - Safety Safety considerations require a nitrogen blanket around the optical-readout electronics and HV to eliminate any possibility of an explosion in the event of a hydrogen leak from the CEDAR. The vacuum beampipe needs to be separated from any source of hydrogen by a nitrogen-filled enclosure and all potential hydrogen leaks monitored and connected to beam and power cut-outs. CERN flammable safety rules require all welds are 100% X-rayed. Care must be taken to avoid enclosures large enough to pose a safety risk when filled with gases other than air. The concept presented here has been discussed with Jonathan Gulley, the CERN flammable safety expert. CEDAR Mechanics Conceptual Design 3

4 Orientation – Existing CEDAR The CEDAR nose has 8 PMTs surrounding a hydrogen-filled section of beampipe. Each PMT is rigidly mounted in close proximity to one of the eight quartz windows. The whole nose is surrounded by a thermally insulated, light-tight, metal box to give a well- protected, robust enclosure

Overview – Adapting the CEDAR Nose Remove current PMTs and location fixtures Re-use the nose: all internal optical components are optimised, and the seals on the quartz windows are perfectly good for hydrogen at 4 bar. The 8 new sets of photo-detectors are separated from the quartz windows in the nose and mirrors and lenses are required to focus the Cerenkov light onto them. The mechanical challenge is to preserve the current optical stability and ensure that all the Cerenkov light reaches the photo-detectors. This requires the precision mounting of the photo-detectors and optical components in a rigid, light-weight structure that can be precisely located relative to the quartz windows of the existing nose. Since the insulated nose cover cannot be used, sufficient insulation must be applied to the nose and surrounding region to minimise temperature gradients and fluctuations in the hydrogen filling of the CEDAR. CEDAR Mechanics Conceptual Design 5

Overview - Beampipe The section of hydrogen-filled beampipe attached to the CEDAR requires a new, thinner aluminium window. We suggest reducing the length of this pipe, since the upstream hydrogen does not contribute to the identification of K +. This will reduce (by a small amount) the beam scattering. A small, nitrogen-filled enclosure will separate this shortened length of pipe from the CERN vacuum beampipe. The lightweight structure housing the PMs will be mounted around the beampipe, but not supported off it. CEDAR Mechanics Conceptual Design 6

Photo-detector Support Structure The eight systems of photo-detectors and electronics will each be located at the end of a radial, tubular ‘spider’ arm The spider arms will be supported by a light-weight aluminium flange surrounding the beampipe A mirror to reflect the Cerenkov light radially outwards towards the photo-detectors will be located at the knee of each arm A lens (or mirror-cones) at the outer end of each arm will focus the light onto the photo-detectors Provision will be made for fine adjustments to the orientation of the mirror We have the technology in Liverpool to fabricate the spider from CFC or aluminium CEDAR Mechanics Conceptual Design 7

8

9

Support Structure – Rigidity and Safety Thermally insulating material will fill the space between each of the 8 spider arms. A layer of insulation, enclosed by a tough CFC membrane, will cover the front and back surfaces to give a rigid, lightweight disc structure. This will ensure dimensional stability and compliance with flammable safety codes Installation: We propose to build the structure in two halves, which can be ‘clam-shelled’ around the beampipe Cables from the photo-detector electronics will be routed around the upstream disc wall to the floor CEDAR Mechanics Conceptual Design 10

Alignment of Support Structure to CEDAR The disc structure will be supported from the floor, with provision to move it along the beampipe to its design location Small adjustments to its position vertically and horizontally relative to the beampipe will enable precise location It will be positioned as close to the CEDAR nose as is reasonably practicable, and precisely located by means of dowels. A lightweight, thermally-insulated, light-tight cylinder will enclose the region between the CEDAR nose and the spider knee-joints. Thermal insulation will be applied to the nose and surrounding region of the CEDAR to minimise temperature fluctuations of the hydrogen gas. CEDAR Mechanics Conceptual Design 11

Cooling of Photo-detectors and Electronics Provision will be made for stabilizing the temperature of the photo-detectors and for thermally isolating the photo-detectors and readout electronics. If liquid nitrogen cooling is required, current practice suggests a system of 8 small dewars mounted on a separate structure supported off the floor, with a cold finger from each dewar cooling the photo-detectors at the end of each spider arm. An automatic filling system for the dewars will be used. Liquid-nitrogen cooling will need substantial design input, as will the enclosures for the readout electronics. Particular attention will need to be paid to modelling the thermal environment and minimising any temperature gradients and thermal instability in the surrounding air. CEDAR Mechanics Conceptual Design 12

Safety considerations and Monitoring Monitoring, connected to an emergency cut-out system, is necessary for the pressure of hydrogen in the CEDAR and to test for leakage of hydrogen from the window seals into the light-tight cylindrical enclosure. The temperature of each readout package must be monitored. A supply of gaseous nitrogen is required to flow through the compartments housing the electronics and HV to ensure an atmosphere free of oxygen. This will eliminate any risk of explosion associated with a potential hydrogen leak. A small overpressure will ensure a nitrogen atmosphere surrounding the optical components in the spider arms and the light-tight cylinder and prevent any possibility of moisture condensing from the atmosphere. The light-tight cylinder will be fitted with a release valve to prevent build up of nitrogen pressure. The cylinder will incorporate lightweight panels spring- loaded onto a frame so that in the unlikely event of a CEDAR window seal failing catastrophically they will be ejected and the hydrogen gas will be able to escape rapidly into the atmosphere. It is suggested that the main body of the CEDAR is instrumented with photocouples so that a continuous readout of hydrogen temperature as a function of position is available for diagnostic purposes. CEDAR Mechanics Conceptual Design 13

Summary The conceptual design has addressed the mechanical challenges involved in redesigning the optical interface to the PMs Preliminary ideas on installation and tooling have been addressed Safety requirements concerning flammable materials have been discussed with CERN Safety and addressed Detailed design work is needed on the electronics housing and the focussing of light onto the active surfaces of the PMs Liquid-nitrogen cooling will involve major design effort and modelling to minimise temperature gradients & thermal instability. Little further progress can be made until the collaboration has chosen the optimum PMs. This is a high priority. CEDAR Mechanics Conceptual Design 14