PowerPoint File available: ~jamesh/powerpoint/ BNL_2011.ppt.

Slides:



Advertisements
Similar presentations
NE Introduction to Nuclear Science Spring 2012
Advertisements

Page 1 Wave / Particle Duality PART I Electrons as discrete Particles. –Measurement of e (oil-drop expt.) and e/m (e-beam expt.). Photons as discrete Particles.
X-ray Diffraction. X-ray Generation X-ray tube (sealed) Pure metal target (Cu) Electrons remover inner-shell electrons from target. Other electrons “fall”
Medical Imaging X-Rays I.
Acknowledgements Christine Gee Janet Newman Tom Peat Center for Structure of Membrane Proteins Membrane Protein Expression Center II Center for HIV Accessory.
Diffraction When “scattering” is not random. detector sample detector x-ray beam scattering.
Compton Effect 1923 Compton performed an experiment which supported this idea directed a beam of x-rays of wavelength  onto a carbon target x-rays are.
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods
Radiation Exposure, Dose and Relative Biological Effectiveness in Medicine Background Image:
Dose. Energy Gained Particles lose energy in matter. Eventually energy loss is due to ionization. An important measure is the amount of energy gained.
Research Opportunities in Radiation-Induced Chemical Dynamics Scientific Opportunities for Studying Laser Excited Dynamics at the LCLS: David Bartels Notre.
CHAPTER 8 (Chapter 11 in text) Characterization of Nanomaterials.
A U.S. Department of Energy laboratory managed by The University of Chicago X-Ray Damage to Biological Crystalline Samples Gerd Rosenbaum Structural Biology.
Interactions with Matter
03/07/2015radiation safety - level 51 Radiation safety level 5 Frits Pleiter.
Radiology is concerned with the application of radiation to the human body for diagnostically and therapeutically purposes. This requires an understanding.
Interaction of Gamma-Rays - General Considerations uncharged transfer of energy creation of fast electrons.
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Simulated diffraction image simulatedreal. SimulatedstatisticReal 5.4%R merge 6.2% 18.9I/sd I/sd (1.4 Ǻ) SDCORR PADFPH31.46.
© 2010 Pearson Education, Inc. Light and Matter: Reading Messages from the Cosmos.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 18 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
NEEP 541 Radiation Interactions Fall 2003 Jake Blanchard.
Ten Years and Change the MX data archive at ALS
Resident Physics Lectures
Long Wave IR Visible UV X-rays Gamma rays wavelength (nm) X-rays absorption.
The Particlelike Properties of Electromagnetics Radiation Wei-Li Chen 10/27/2014.
Spectroscopy Light in chemistry. The Nature of Light Acts as both a particle and a wave Photoelectric effect only explained through waves Interference,
PowerPoint File available: ~jamesh/powerpoint/ Oslo_2010.ppt.
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
Where do photons go When they come out of the beamline and hit my crystal.
Medical Imaging Radiation I. Naked to the Bone: Medical Imaging in the Twentieth Century (Paperback)by Bettyann Kevles Bettyann Kevles E=mc2: A Biography.
Plan : intro Characterization of thin films and bulk materials using x-ray and electron scattering V. Pierron-Bohnes IPCMS-GEMME, BP 43, 23 rue du Loess,
Chapter 6 An Introduction to Spectrometric Methods Spectrometric methods are a large group of analytical methods that are based on atomic and molecular.
Chapter 27- Atomic/Quantum Physics
Photons, Electrons, and Atoms. Visible and non-visable light Frequencies around Hz Much higher than electric circuits Theory was about vibrating.
NANO 230 Micro/Nano Characterization
“hands-off” Screening with TOPAZ Chips For the purposes of testing both crystallization behavior and capability of the “tray goniometer”, chips were built.
1 Interaction Between Ionizing Radiation And Matter, Part 3 Neutrons Audun Sanderud Department of Physics University of Oslo.
Applications of Monte Carlo Code for a Gamma Resonance System Analysis L. Wielopolski, A. Hanson, I. Dioszegi, M. Todosow, Brookhaven National Laboratory,
Chapter 5 Interactions of Ionizing Radiation. Ionization The process by which a neutral atom acquires a positive or a negative charge Directly ionizing.
Interactions of EM Radiation with Matter
Determining Radiation Intensity
Beamline summary 1.Strong PRT and staff 2.Robust optics and endstation 3.Safety: stable, simple operations 4.Funding: Operational funding secure.
Key slides. Holton J. M. and Frankel K. A. (2010) Acta D66, 393–408.
PowerPoint File available: ~jamesh/powerpoint/ ACA_SINBAD_2013.ppt.
PowerPoint File available: ~jamesh/powerpoint/ SHSSS_Berlin_2015.pptx.
Center for Structures of Membrane Proteins © 2006 Optimizing x-ray structure determination James Holton LBNL/UCSF April 6, 2006.
1.1 What’s electromagnetic radiation
Chemistry – Chapter 4. Rutherford’s Atomic Model.
Interaction Ionizing Radiation with Matter BNEN Intro William D’haeseleer BNEN - Nuclear Energy Intro W. D'haeseleer
INTERACTIONS OF RADIATION WITH MATTER. twCshttp:// twCs
Acknowledgements Christine Gee Janet Newman Tom Peat Center for Structure of Membrane Proteins Membrane Protein Expression Center II Center for HIV Accessory.
Interaction of x-ray photons (and gamma ray photons) with matter.
Crystallography : How do you do? From Diffraction to structure…. Normally one would use a microscope to view very small objects. If we use a light microscope.
 What do you call the following phase changes?  Solid to a liquid  Melting  Liquid to a solid  freezing  Liquid to a gas  vaporization  Gas to.
Interactions of Ionizing Radiation
Lecture 5. Particle Properties of Waves (cont’d)
Interaction of Radiation with Matter
Why are. we not solving more struct tures? James Holton University of California San Francisco and Advanced Light Source Lawrence.
Why are. we not solving more struct tures? James Holton University of California San Francisco and Advanced Light Source Lawrence.
Chapter 2 Radiation Interactions with Matter East China Institute of Technology School of Nuclear Engineering and Technology LIU Yi-Bao Wang Ling.
INTERACTION OF PARTICLES WITH MATTER
Chapter 5 Interactions of Ionizing Radiation
NANO 230 Micro/NanoFabrication
Learning Objectives By the end this lesson you should…
Outside the nucleus, the beta decay {image} will not occur because the neutron and electron have more total mass than the proton. This process can occur.
Resident Physics Lectures (Year 1)
Resident Physics Lectures (Year 1)
Wave / Particle Duality
Presentation transcript:

PowerPoint File available: ~jamesh/powerpoint/ BNL_2011.ppt

Acknowledgements Ken Frankel Rick Donahue Howard Padmore Alastair MacDowell creator: Tom Alber PRT head: Jamie Cate Center for Structure of Membrane Proteins (PSI) Membrane Protein Expression Center II Center for HIV Accessory and Regulatory Complexes W. M. Keck Foundation Plexxikon, Inc. M D Anderson CRC University of California Berkeley University of California San Francisco National Science Foundation University of California Campus-Laboratory Collaboration Grant Henry Wheeler The Advanced Light Source is supported by the Director, Office of Science, Office of Basic Energy Sciences, Materials Sciences Division, of the US Department of Energy under contract No. DE-AC02-05CH11231 at Lawrence Berkeley National Laboratory.

The optimum wavelength for macromolecular crystallography Higher? or Lower?

Charged Particle Equilibrium (CPE) Johns, H. & Cunningham, J. (1974). The physics of radiology. Thomas Springfield, Illinois.

dose Johns, H. & Cunningham, J. (1974). The physics of radiology. Thomas Springfield, Illinois. ~1 cm at 1 MeV f NH Charged Particle Equilibrium (CPE)

satisfies CPE collimator crystal X-ray e-e- violates CPE Assume a spherical crystal…

is there a “problem” with violating CPE? ICRU report 31 “Average Energy Required to Produce an Ion Pair” (1979) for air: W ~ 30 eV/ion-pair yet, final ions are thermalized (<0.1 eV each) Where does 99% of the energy go? Answer: non-ionizing excitations

Secondary ionization e-e-

e-e- e-e- +

Excitation e-e-

e-e-

e-e-

ionizing interactions e-e- + Violating CPE: two kinds of “dose”? non-ionizing interactions ICRU report 36 “Microdosimetry” (1984)

Charged Particle Equilibrium (CPE) Johns, H. & Cunningham, J. (1974). The physics of radiology. Thomas Springfield, Illinois. skin not burned

Ionization track

particle transport simulation using MCNP collimator crystal X-ray

Where do photons go? beamstop Transmitted (98%) Protein 1A x-rays

Where do photons go? beamstop elastic scattering (6%) Transmitted (98%) Protein 1A x-rays

Elastic scattering

Inelastic scattering e-e- +

Where do photons go? beamstop elastic scattering (6%) Transmitted (98%) Protein 1A x-rays

Where do photons go? beamstop elastic scattering (6%) Transmitted (98%) inelastic scattering (7%) Protein 1A x-rays

Where do photons go? beamstop elastic scattering (6%) Transmitted (98%) inelastic scattering (7%) Protein 1A x-rays Re-emitted (99%)Absorbed (~0%)

Photoelectric absorption

e-e- +

Where do photons go? beamstop elastic scattering (6%) Transmitted (98%) inelastic scattering (7%) Protein 1A x-rays Re-emitted (99%)Absorbed (~0%)

Where do photons go? beamstop elastic scattering (6%) Transmitted (98%) inelastic scattering (7%)Photoelectric (87%) Protein 1A x-rays Re-emitted (99%)Absorbed (~0%)

Where do photons go? beamstop elastic scattering (6%) Transmitted (98%) inelastic scattering (7%)Photoelectric (87%) Protein 1A x-rays Re-emitted (~0%)Absorbed (99%) Re-emitted (99%)Absorbed (~0%)

Fluorescence +

e-e- +

Auger emission +

++ e-e-

MCNP cuts off at 1 keV 1 MeV100 GJ/molMedical radiation therapy 100 keV10 GJ/molMedical imaging 10 keV1 GJ/molX-ray crystallography 1 keV100 MJ/molS and P K-edges 100 eV10 MJ/mol“water window” 10 eV1 MJ/molC≡C bond 1 eV100 kJ/molC-C bond, visible light 100 meV10 kJ/molhydrogen bond 10 meV1 kJ/molheat (~300 K)

bonding affects absorption Almkvist, et al. (2010)."K-edge XANES analysis of sulfur compounds: an investigation of the relative intensities using internal calibration", J. Sync. Rad. 17, MCNP model

particle transport simulation using MCNP collimator crystal X-ray

dose reduction with 1 Å radiation Crystal diameter (µm) Dose capture fraction f NH ←???→ 1 keV e - pathlength

100 μm crystal vs energy Photon Energy Dose capture fraction 1 keV 10 keV 100 keV 1 MeV f NH

dose reduction vs energy Photon Energy Dose capture fraction 1 keV 10 keV 100 keV 1 MeV

2 variables Dose capture fraction

Critical escape diameter Photon Energy (eV) Crystal diameter (µm)

Critical escape diameter Photon Energy (eV) Crystal diameter (µm)

Critical escape diameter Photon Energy (eV) Crystal diameter (µm)

Critical escape diameter Photon Energy Crystal diameter (µm) 1 keV 10 keV 100 keV 1 MeV 10 MeV

Darwin’s Formula I(hkl)- photons/spot (fully-recorded) I beam - incident (photons/s/m 2 ) r e - classical electron radius (2.818x m) V xtal - volume of crystal (in m 3 ) V cell - volume of unit cell (in m 3 ) λ- x-ray wavelength (in meters!) ω- rotation speed (radians/s) L- Lorentz factor (speed/speed) P- polarization factor (1+cos 2 (2θ) -Pfac∙cos(2Φ)sin 2 (2θ))/2 A- absorption factor exp(-μ xtal ∙l path ) F(hkl)- structure amplitude (electrons) P A | F(hkl) | 2 I(hkl) = I beam r e 2 V xtal V cell λ 3 L ωV cell Darwin, C. G. (1914)."The theory of X-ray reflexion. Part I", Philos. Mag. 27,

Darwin’s Formula I(hkl)- photons/spot (fully-recorded) I beam - incident (photons/s/m 2 ) r e - classical electron radius (2.818x m) V xtal - volume of crystal (in m 3 ) V cell - volume of unit cell (in m 3 ) λ- x-ray wavelength (in meters!) ω- rotation speed (radians/s) L- Lorentz factor (speed/speed) P- polarization factor (1+cos 2 (2θ) -Pfac∙cos(2Φ)sin 2 (2θ))/2 A- absorption factor exp(-μ xtal ∙l path ) F(hkl)- structure amplitude (electrons) P A | F(hkl) | 2 I(hkl) = I beam r e 2 V xtal V cell λ3 Lλ3 L ωV cell Darwin, C. G. (1914)."The theory of X-ray reflexion. Part I", Philos. Mag. 27,

Darwin’s Formula I(hkl)- photons/spot (fully-recorded) I beam - incident (photons/s/m 2 ) r e - classical electron radius (2.818x m) V xtal - volume of crystal (in m 3 ) V cell - volume of unit cell (in m 3 ) λ- x-ray wavelength (in meters!) ω- rotation speed (radians/s) L- Lorentz factor (speed/speed) P- polarization factor (1+cos 2 (2θ) -Pfac∙cos(2Φ)sin 2 (2θ))/2 A- absorption factor exp(-μ xtal ∙l path ) F(hkl)- structure amplitude (electrons) P A | F(hkl) | 2 I(hkl) = I beam r e 2 V xtal V cell λ 3 L ωV cell Darwin, C. G. (1914)."The theory of X-ray reflexion. Part I", Philos. Mag. 27,

Dose Formula dose- absorbed energy (Gy) I beam - incident (photons/s/μm 2 ) t exp - exposure time (s) λ- x-ray wavelength (in Å) dose ≈ I beam ·t exp λ2λ2 2000

Dose Formula D max - maximum dose (Gy) I beam - incident (photons/s/μm 2 ) t dataset - accumulated exposure time (s) λ- x-ray wavelength (in Å) D max ≈ I beam ·t dataset λ2λ2 2000

Dose Formula D max - maximum dose (Gy) I beam - incident (photons/s/μm 2 ) t dataset - accumulated exposure time (s) R- radius of crystal T en - transmission of a sphere ~ exp(-μ en ·2R)  - density of crystal E ph - photon energy q e - electron charge D max = I beam ·t dataset 3q e E ph 4R  (1-T en )

Darwin’s Formula I(hkl)- photons/spot (fully-recorded) I beam - incident (photons/s/m 2 ) r e - classical electron radius (2.818x m) V xtal - volume of crystal (in m 3 ) V cell - volume of unit cell (in m 3 ) λ- x-ray wavelength (in meters!) ω- rotation speed (radians/s) L- Lorentz factor (speed/speed) P- polarization factor (1+cos 2 (2θ) -Pfac∙cos(2Φ)sin 2 (2θ))/2 A- absorption factor exp(-μ xtal ∙l path ) F(hkl)- structure amplitude (electrons) P A | F(hkl) | 2 I(hkl) = I beam r e 2 V xtal V cell λ 3 L ωV cell Darwin, C. G. (1914)."The theory of X-ray reflexion. Part I", Philos. Mag. 27,

Darwin’s Formula D max - maximum dose (kGy) t dataset - accumulated exposure (s) r e - classical electron radius (2.818x m) V xtal - volume of crystal (in m 3 ) V cell - volume of unit cell (in m 3 ) λ- x-ray wavelength (in meters!) ω- rotation speed (radians/s) L- Lorentz factor (speed/speed) P- polarization factor (1+cos 2 (2θ) -Pfac∙cos(2Φ)sin 2 (2θ))/2 A- absorption factor exp(-μ xtal ∙l path ) F(hkl)- structure amplitude (electrons) P A | F(hkl) | 2 I(hkl) = r e 2 V xtal V cell 2 λ L ωV cell D max t dataset Darwin, C. G. (1914)."The theory of X-ray reflexion. Part I", Philos. Mag. 27,

Darwin’s Formula D max - maximum dose (kGy) r e - classical electron radius (2.818x m) V xtal - volume of crystal (in m 3 ) V cell - volume of unit cell (in m 3 ) λ- x-ray wavelength (in meters!) 2π- rotation range (radians) L- Lorentz factor (speed/speed) P- polarization factor (1+cos 2 (2θ) -Pfac∙cos(2Φ)sin 2 (2θ))/2 A- absorption factor exp(-μ xtal ∙l path ) F(hkl)- structure amplitude (electrons) P A | F(hkl) | 2 I(hkl) = r e 2 V xtal V cell 2 λ L 2πV cell D max Darwin, C. G. (1914)."The theory of X-ray reflexion. Part I", Philos. Mag. 27,

Holton & Frankel (2010) Acta D

Where:  I  DL - average damage-limited intensity (photons/hkl) at a given resolution converting R from μm to m, r e from m to Å, ρ from g/cm 3 to kg/m 3 and MGy to Gy r e - classical electron radius (2.818 x m/electron) h- Planck’s constant (6.626 x J∙s) c- speed of light ( m/s) f decayed - fractional progress toward completely faded spots at end of data set ρ- density of crystal (~1.2 g/cm 3 ) R- radius of the spherical crystal (μm) λ- X-ray wavelength (Å) f NH - the Nave & Hill (2005) dose capture fraction (1 for large crystals) n ASU - number of proteins in the asymmetric unit M r - molecular weight of the protein (Daltons or g/mol) V M - Matthews’s coefficient (~2.4 Å 3 /Dalton) H- Howells’s criterion (10 MGy/Å) θ- Bragg angle  a 2  - number-averaged squared structure factor per protein atom (electron 2 )  M a  - number-averaged atomic weight of a protein atom (~7.1 Daltons) B- average (Wilson) temperature factor (Å 2 ) μ- attenuation coefficient of sphere material (m -1 ) μ en - mass energy-absorption coefficient of sphere material (m -1 ) Self-calibrated damage limit Holton & Frankel (2010) Acta D

wavelength dependence crystal diameter (μm) Å Minimum size for complete data set f NH = 1

Where:  I  DL - average damage-limited intensity (photons/hkl) at a given resolution converting R from μm to m, r e from m to Å, ρ from g/cm 3 to kg/m 3 and MGy to Gy r e - classical electron radius (2.818 x m/electron) h- Planck’s constant (6.626 x J∙s) c- speed of light ( m/s) f decayed - fractional progress toward completely faded spots at end of data set ρ- density of crystal (~1.2 g/cm 3 ) R- radius of the spherical crystal (μm) λ- X-ray wavelength (Å) f NH - the Nave & Hill (2005) dose capture fraction (1 for large crystals) n ASU - number of proteins in the asymmetric unit M r - molecular weight of the protein (Daltons or g/mol) V M - Matthews’s coefficient (~2.4 Å 3 /Dalton) H- Howells’s criterion (10 MGy/Å) θ- Bragg angle  a 2  - number-averaged squared structure factor per protein atom (electron 2 )  M a  - number-averaged atomic weight of a protein atom (~7.1 Daltons) B- average (Wilson) temperature factor (Å 2 ) μ- attenuation coefficient of sphere material (m -1 ) μ en - mass energy-absorption coefficient of sphere material (m -1 ) Self-calibrated damage limit Holton & Frankel (2010) Acta D

wavelength dependence crystal diameter (μm) Å Minimum size for complete data set

wavelength dependence crystal diameter (μm) Å Minimum size for complete data set

wavelength dependence crystal diameter (μm) Å Å Minimum size for complete data set

molecular weight crystal diameter (μm) 100 Da 1 kDa 10 kDa 100 kDa 1 MDa 10 MDa Minimum size for complete data set 1 Å X-rays 2 Å spots B = 24 50% solvent

Prediction: Exploiting Nave-Hill effect will require multi-crystal datasets

Other reasons for high energy room temperature

Zero-parallax microscope pinhole mirror microscope

High energy compresses pattern 2 Å data

Example Room-temperature Data lysozyme 50 μm beam 37 Gy/s (0.775 Å) 30s exposures at 20C 90° of data, 97% complete I/  = 1.5 at 1.9 Å R merge 18% (overall) 5% (low) ΔB same as 20 min at 100K B factor scale vs batch

high energy myth: less background elastic background/spot intensity ratio is wavelength-independent!

photon energy (eV) normalized figure of merit obliquity effect

high energy myth: less background elastic background/spot intensity ratio is wavelength-independent! However: inelastic and fluorescence are less, as is absorption

Other reasons for high energy room temperature high pressure?

Room temperature damage rates dose rate (kGy/s) dose at half intensity (MGy)

Room temperature damage rates dose rate (kGy/s) dose at half intensity (MGy)

Room temperature damage has a size dependence?

Radiation Damage “scale factor” F 2 alone cannot explain change in overall scale!

Darwin’s Formula I(hkl)- photons/spot (fully-recorded) I beam - incident (photons/s/m 2 ) r e - classical electron radius (2.818x m) V xtal - volume of crystal (in m 3 ) V cell - volume of unit cell (in m 3 ) λ- x-ray wavelength (in meters!) ω- rotation speed (radians/s) L- Lorentz factor (speed/speed) P- polarization factor (1+cos 2 (2θ) -Pfac∙cos(2Φ)sin 2 (2θ))/2 A- absorption factor exp(-μ xtal ∙l path ) F(hkl)- structure amplitude (electrons) C. G. Darwin (1914) P A | F(hkl) | 2 I(hkl) = I beam r e 2 V xtal V cell λ 3 L ωV cell

“scale factor” implies that damaging motions are larger than unit cell Room temperature damage has a size dependence? high pressure will hold it together? suggests micro-fracture mechanism of spot fading

Radiation Damage prediction large displacements cannot be faster than the speed of sound

Timescales of radiation damage Garret et. al. (2005) Chem. Rev. 105,

Two types of reactions Garret et. al. (2005) Chem. Rev. 105, nonhomogeneous homogeneous

Timescales of radiation damage Garret et. al. (2005) Chem. Rev. 105, LCLS ALS bunch

Room temperature damage rates dose rate (kGy/s) dose at half intensity (MGy)

Room temperature damage rates dose rate (kGy/s) dose at half intensity (MGy)

Nozzle ground to provide large X-ray diffraction angle Droplets freeze at 10 6 o /sec. in vacuum to vitreous ice if cryoprotectant added. Hand-grinding to micron gives large take-off angle for X-rays ! D. DePonte X-rays 5 microns Flow rate 12 microliters per minute. An environmental SEM image of operating protein-beam injector for LCLS.

What about very low energy?

sample shadow on detector Cu

sample shadow on detector

X-ray of cryo stream

low-energy X-rays Cu λ=2d sinθ 2.5 Å data with 5 Å X-rays International Tables for Crystallography, Vol. C, 2nd ed., chapter 6.3

Detector d = 2.5 Å sample injector Mirrors λ = 5 Å d = 2.5 Å h,k,l -h,-k,-l Colliding Beam Anomalous Measurement

Anomalous differences are resilient to non-isomorphism R iso (%) Correlation Coefficient of ΔF ano 100 x 100 lysozyme PDBs

The optimum wavelength for macromolecular crystallography Maximize data/damage→15-50 keV Turn the crank → keV Native element phasing→ keV the future: multi-crystal data sets

PowerPoint File available: ~jamesh/powerpoint/ BNL_2011.ppt