Gel Filtration Chromatography.

Slides:



Advertisements
Similar presentations
Chromatography Components stationary phase (eg., solid matrix) mobile phase (eg., solvent) solute Solutes which interact differently with the stationary.
Advertisements

Gel Filtration Gel permeation chromatography Size exclusion chromatography Separation of molecules on the basis of size (and shape)
Size Exclusion Chromatography
Foundation GPC Training Course Theory. Nomenclature Gel Permeation ChromatographyGPC Size Exclusion ChromatographySEC Gel Filtration ChromatographyGFC.
1 HPLC Lecture Mobile Phase Selection in Partition Chromatography Optimization of the mobile phase composition and polarity is vital for obtaining.
Separation of molecules and determination of there molecular weight by gel filtration chromatography. Experiment 7 BCH 333.
Chromatography for Protein purification 1
Ion Exchange Laboratory. Today’s Schedule Pre-lab discussion Ion Exchange and Spectrophotometer Ion exchange experiment.
Paper and Thin layer Chromatography
Chromatography.
Size-exclusion chromatography (SEC) Gel permeation chromatography (GPC) Gel Filtration Chromatography (GFC)
1. 2  A form of “partition chromatography”.  Stationary phase is a porous gelatinous matrix (in the form of beads).  Sample components enter pores.
Electrophoretic techniques. Introduction: _The term electrophoresis describe the migration of a charged particle under the influence of an electric field.
Gel filtration Chromatography
Agarose Gel Electrophoresis
Salting out is a method of separating proteins based on the principle that proteins are less soluble at high salt concentrations. The salt concentration.
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
Separation of proteins by ion exchange chromatography
In the name of god.
Basics of Chromatography Jony Mallik. Introductory Principles Chromatography is a combination of two words; * Chromo – Meaning color * Graphy – representation.
Chromatography Desalting and Affinity. Chromatography Technique to separate components of a mixture by passing them through a matrix. –A solvent is used.
Chemistry 4010 Lab It’s all about PROTEINS… It’s all about PROTEINS…
Gel filtration chromatography y/college/voet/ /animat ed_figures/ch05/f5-6.html.
Chapter 4-1 Chromatography
Types of Mechanism in the Chromatography
Magnet Analytical Chemistry Unit 4
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
BIOCHEMICAL METHODS USED IN PROTEN PURIFICATION AND CHARACTERIZATION
Factors affecting electrophoresis The electric field ·       Voltage. If the separation of the electrodes is d (cm) and the potential difference.
ERT106 BIOCHEMISTRY PROTEIN TECHNOLOGY By Pn Syazni Zainul kamal.
Chemistry 1- Separation Objectives: 1) Learn about 2 different separation methods.
Agarose Gel Electrophoresis
Proteins separation and analysis using Fast Protein Liquid Chromatography Ayelet David, Ph.D Dept. of Clinical Pharmacology.
High Performance Liquid Chromatography. The chromatogram is a record of detector output Vs time as the analyte passes through the chromatography.
Principle of separation
HPLC.
Ch 21 – Principles of Chromatography and Mass Spectrometry Ch 22 – Gas and Liquid Chromatography.
Introduction to Instrumental Analysis - Chromatography
Size-exclusion Chromatography prof. aza Department of Pharmacy, Andalas University STIFI Perintis, Padang STIFAR, Pekan Baru STIFI Bhakti Pertiwi, Palembang.
T.A Nouf Alshareef KAU-Faculty of Science- Biochemistry department Analytical biochemistry lab (Bioc 343) 2012 False colour scanning.
Analytical biochemistry lab KAU-biochemistry dep. L. Nouf Alshareef
Ion exchange chromatography
GEL FILTRATION CHROMATOGRAPHY Size Exclusion Chromatography
Food Analysis Lecture 18 (03/27/2012) Basic Principles of Chromatography (3) Qingrong Huang Department of Food Science Read Material: Chapter 27, page.
BY G.SHRAVANI ION EXCHANGE AND GEL PERMEATI ON CHROMATOGRAPHY 1G.SHRAVANI.
Tutorial 09 Overview of other chromatographic methods 1.
Purification of immunoglubin by ion exchange chromatography Bahiya Osrah
Principles of chromatography
SIZE EXCLUSION CHROMATOGRAPHY
Size exclusion Chromatography
Tymoczko • Berg • Stryer © 2015 W. H. Freeman and Company
 Laboratory technique for the Separation of mixtures  Chroma -"color" and graphein - "to write”.  Colour bands - separation of individual compounds.
CHROMATOGRAPHY 1Biochemistry of Medics. Chromatography 2Biochemistry of Medics.
High Performance Liquid Chromatography. What is HPLC ? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube.
Bioseparation II Chromatography Techniques. Chromatography Most widely used purification technique used for biomolecules. Most widely used purification.
Gel Permeation Chromatography Size Exclusion Chromatography
BCH BIOCHEMICAL METHODS (2 UNITS) DR AKINLOYE’S ASPECT
Purification Of Proteins.
Lecture 2: Introduction to Chromatography and Size- Exclusion Chromatography Yaj.
Why Do We Analyze Proteins?
Chapter 4-3 Chromatography Gel Chromatography Dr Gihan Gawish.
Gel Filtration Chromatography.
Size Exclusion Chromatography (SEC)
Basics of Chromatography
Biophysical Tools '04 - Chromatography
Separation of Molecules by Ion Exchange Chromatography
Gel Filtration Chromatography.
Separation of Molecules by Ion Exchange Chromatography
M.S COLLEGE OF ARTS, SCIENCE, COMMERCE AND B.M.S
Presentation transcript:

Gel Filtration Chromatography. Experiment 5 Gel Filtration Chromatography. BCH 333 [practical]

Objectives: The objective of this experiment is for students to learn the principles of gel filtration chromatography by separating of two substance according to the molecular weights. 2. A practical experience on gel filtration chromatography in the laboratory. 3. Importance of gel filtration chromatography and procedures in purification.

3-Gel filtration chromatography: Also called "Molecular Sieve“ or "Size or gel Exclusion’’. well suited for biomolecules that: Very sensitive to the changes in pH and harsh environmental factors. -If the protein is relatively large (over 100 KDa), gel filtration could be used as an initial step in the purification.

Gel filtration chromatography Mobile phase: buffer or solvent. In this lab the mobile phase is NaCl. Stationary phase: (column matrix) "beads" of hydrated, porous polymer.

Principle: -Gel filtration chromatography separates proteins according to their size. And the molecules are "filtered" through the porous beads. -The gel filtration matrix[stationary phase] contains pores which permit the buffer, small and medium sized molecules to pass through them. -Large molecules can’t get through any pores in the beads and move more rapidly through the column, emerging (eluting) sooner.[elute from the column before the smaller proteins]. - Medium-sized molecules can enter the larger size pores in the matrix, and so they reach the end of the column later. -Small molecules can enter through all pores of the beads and they have the largest volume to pass through before emerging from the column last.  elute last.

The principle of gel filtration chromatography (Figure has been taken from- (http://mortada8.maktoobblog.com/category/instrumental-analysis-studies/chromatographystudies/)

Gel Filtration Chromatography.

Stationary phase [beads]….info.: -The gels used as molecular sieves consist of cross-liked polymers that are generally inert, do not bind or react with the material being analyzed, and are uncharged. Mobile phase: Is the liquid fills the space inside the beads and between the bead particles and this liquid occupies most of the bed volume.

Gel Filtration Resins The gels currently in use are of three types: dextarn, agarose, and polyacrylamide. 1-Dextran [e.g. Sephadex]: -is a polysaccharide composed of glucose residues. -prepared with various degrees of cross-linking to control pores size. -supplied in the form of dry beads that swell when water is added. -It is mainly used for separation of small peptides and globular proteins with small to average molecular mass.

-gel beads come in various sizes: large, medium, fine, and superfine. General information: -The pore size determines the range of molecular weight in which fractionation occurs. -gel beads come in various sizes: large, medium, fine, and superfine. -All consist of semi-permeable, porous gels of cross linked polymers with a range of pore sizes. -The degree of cross linking is controlled to yield a series of gels having different pore sizes.

NOTES: -The larger the beads, the more rapid the flow rate and the poorer the resolution. [because as the flow rate increases, the time available for the molecules to equilibrate between the mobile phase and the pore space in the stationary phase decreases.] When it is used??? The larger beads are for very large preparation in which resolution is less important than time. -Super fine, is used if maximum resolution is required and the time is less important.

Advantages of gel filtration: It is the best method for separation of molecules differing in molecular weight because: 1. It doesn’t depend on temperature, pH, ionic strength and buffer composition, so, separation can be carried out under any conditions. 2. There is less zonal spreading than in other techniques. 3. The elution volume is related to the molecular weight. 4. Important method in protein purification. 5.This separation method is unique in fractionating without requiring protein binding, thus significantly reducing the risk of protein loss.

To estimate the molecular weight for a protein: 1. Several proteins with known molecular weights are run on the column and their elution volumes determined. 2. The elution volumes are then plotted against the log molecular weight of the corresponding proteins. 3. A straight line is obtained for the separation range of the gel being used. 4. The elution volume of a protein of unknown molecular weight is then found, [it can be compared to the calibration curve and the molecular weight determined.]

elution volume, Ve is proportional to log of molecular weight. For high molecular weight less elution volume is needed, and for small molecular weight the large elution volume is needed to elute the sample.

Cautions must be taken: It is important that the gel should be: Homogenous. Free from bubbles. Free from cracks. Free from spaces between the walls. And it should be covered by the liquid "mobile phase" all the time.

For every column, three volumes should be distinguished: The void volume, Vo: - The volume of the mobile phase in the space between the beads . [which is the volume external to the beads]. -Can be determined by the elution of High MW molecules which can not enter any pores . 2. The total volume, Vt (bed volume): -The total volume of material in the column (both solid and liquid). [can be calculated from the dimension of the column.] 3. The elution volume, Ve, of molecules: - the amount of liquid( mobile phase) that must be added to produce a peak of a particular solute in the effluent. Or the volume required for completely eluting the solute from column.

Gel Filtration Chromatography.

-Loading the sample : small volume of sample is placed on the stationary phase and allowed to enter the column. -Packing the column: Preparation of the gel and loading it in the column.

The most common application of gel filtration in biochemistry are: -Molecular weight determination. -Fractionation of macromolecules. -purification.

Practical Considerations -Gels of various pore size are available  choose the one with the best fractionation range for your sample -Good separation usually require long columns and slow flow rate. -Gel filtration is NOT recommended for separating proteins with only a small difference in molecular weight .

The gel filtration material that will be used in the experiment is called Sephadex G-100 and it will separate molecules with molecular weights from 4,000 to 150,000 Da. So, Those molecules which are with molecular weight larger than 150,000 will be excluded from the beads, because of their huge size they can not get through the pores of the beads, and elute first. In your experiment: you will separate a mixture of blue dextran [sugar] with m.wt.= 2,000,000 Da and bromophenol blue[dye] m.wt.= 669.99 Da .