Cochran Consulting, Inc.

Slides:



Advertisements
Similar presentations
How to use the NEC projector Its easy! Really!. How to use the NEC projector IMPORTANT-make sure you have reserved the equipment (projector and/or laptop).
Advertisements

Digital Current Transformer Reporter
PC Encryption installation progress/password screen Includes comments from: Encryption team Sarah Deane Tony Stieber Selected people who took part in the.
The EZ-SAT.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Easy Set-Up Instructions
Lokotrack ST352 Presentation
Troubleshooting Training Course.  Visual and General Test  Perform System Test (Mode  Perform System Test)  Identify The Error  If you need Technical.
LogTag Training January 2015
1 Check all equipment is included before returning. If you have an accident or the equipment is damaged or you need support please contact Blaize
GS3055-I GSM Universal Wireless Alarm Communicator
 Description of PressurePro System  Identify system components  Display and Operational Modes  Sensor alerts  Checking of tire pressures  Manual.
4Identifying Leakage Source (Mech/ Elec) 4Mechanical Air Leak- Down 4Mechanical Air Leak- Up 4Electronic Drift- Up/ Down 4Load Cell Operation 4Understanding.
© 2008 Masimo Corporation Includes a review on Carbon Monoxide Poisoning For Emergency Responders V.8 1 May 2011 Monitoring CO Poisoning with the Rad-57.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
AquaGlo Water Detector Kit For Detecting Water in Jet Fuel
Quick Start Guide for operation
GPS. Meet the Bad Elf GPS Pro The Bad Elf GPS Pro offers the first Apple approved GPS with an informative user interface.
AccuMax Multi-Point Injection Mechanics
The Impulse “Switch” 1Daniel Overman DIS5274/10/2010.
Cochran Consulting, Inc.
1 Training Manual: KI7400 & 7800 Series Sources Level 1, V2.0 August 2008.
Toll Free: Project Manager Tutorial.
1 BRIDGEPAD (BP) SYSTEM TRAINING Adapted for ScoreBridge Users By John de Ridder PSBC Revised 2 November 2009.
Configuring the MagicInfo Pro Display
FG Wilson Access 4000 Control Panel
Programming and Application Packages
The Mavica for the Maverick: A How-to Guide Operating instructions for the Sony Mavica CD350 Digital Camera An Easy-to-Follow Guide to Everything You Need.
White Knight Tap Locator HJ Arnett Industries, LLC Portland, OR
© 2008 Masimo Corporation RAD-57 EMS Carry Case Lightweight: 13 oz. Small: 6.2” x 3.0” x 1.4” Portable: operates on 4 “AA” batteries Supplied with high-visibility,
 Computer memory is device that is used to store data or programs (sequences of instructions) on a temporary or permanent basis for use in an electronic.
Automotive Engines: Theory and Servicing, 7/e By James D. Halderman Copyright © 2011, 2009, 2005, 2001, 1997 Pearson Education, Inc., Upper Saddle River,
COCHRAN EMC-20H w/Helium
ZIMS Tips and Tricks February 2015 Managing Your Staff and My Institution 1.
Mercury G3 Service Tool Training Overview When opening G3 you will start at this screen first import thing to look for is communication.
Easy Set-Up Instructions Vuze ® Table Location System (PC Version) Questions ? Phone: , option 2
CONGRATULATIONS ON YOUR NEW COCHRAN EMC-20H DIVE COMPUTER Cochran Undersea Technology a division of Cochran Consulting, Inc. Copyright All.
Office of Housing Choice Voucher Program Voucher Management System – VMS Version Released October 2011.
Cochran Tethered Diving Telemetry 19 October 2015 © 2015 Cochran Consulting, Inc. Cochran Consulting, Inc. For Advanced, Professional, Scientific, and.
Lifeguard ® C1 Metric Displays Tutorial © 2015 Cochran Consulting, Inc. Introduction CPU Module C1 Metric Displays Cochran Consulting, Inc. 21 October.
© 2015 Cochran Consulting, Inc. Lifeguard ® Battery Tutorial 19 October 2015 Lifeguard Recorder and CPU Modules Batteries Lifeguard Display Modules Battery.
Lifeguard ® PO2 Sensors ‘Tee’ Tutorial © 2015 Cochran Consulting, Inc. Introduction PO2 Sensor Factors PO2 Sensor Tee Installation Cochran Consulting,
OTS / Lifeguard ® Install Tutorial © 2015 Cochran Consulting, Inc. Introduction System Overview Lifeguard D1 Connection Lifeguard Pickup Install Cochran.
Hytech / Lifeguard ® Install Tutorial © 2015 Cochran Consulting, Inc. Introduction System Overview Lifeguard D3 Connection Lifeguard Pickup Install Cochran.
Computer Maintenance Chapter Five BIOS and CMOS Dr. Mohammad AlAhmad.
© 2005 Avaya Inc. All rights reserved. Avaya – Proprietary & Confidential. For Limited Internal Distribution. The information contained in this document.
Smart Streetlight Proof of Concept Group 3 03/26/16 Tucker Russ Thor Cutler Brandon Berry Anthony Giordano.
COCHRAN EMC-16 DIVE COMPUTER Quick Start Guide for operation Diving is a complex sport and many different situations may occur. Your Cochran EMC-16 is.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
SmartBoard Basics By Kate M 1. Computer Hints Please do NOT turn the computers off after class If the previous instructor has not log off the computer.
Analyst ® 5 Introduction 13 June 2016 Introduction Analyst Editions Analyst Libraries Connecting the USB Module © 2016 Cochran Consulting, Inc.
Cochran Consulting, Inc.
Do-more Technical Training
Preliminary Document Cochran Consulting, Inc. 31 July 2016
Wireless 4 Buttons Touch Panel
Wireless 3 Buttons Touch Panel
Cochran Consulting, Inc.
Cochran Consulting, Inc.
G450 and G460 battery pack maintenance
Cochran Consulting, Inc.
Cochran Consulting, Inc.
Digital Chart Recorder Operation
Cochran Consulting, Inc.
Cochran Consulting, Inc.
Cochran Consulting, Inc.
Cochran Consulting, Inc.
Cochran Consulting, Inc.
Cochran Consulting, Inc.
TR20 Series Wireless Training Slides
Cochran Consulting, Inc.
Presentation transcript:

Cochran Consulting, Inc. Lifeguard® Displays Tutorial 15 June 2015 Cochran Consulting, Inc. “Not Just Another Dive Computer” © 2015 Cochran Consulting, Inc.

Lifeguard® Displays Tutorial Features Common to All Display Modules Lifeguard Display Modules are the means of the Lifeguard Family to show information to the diver. They are all wireless, hoseless, and very simple to operate and have no task loading. This is usually referred to as a “Lifeguard Display Module”. The Display Module receives data transmitted from a Lifeguard CPU Module that have matching addresses and are within a one meter radius of each other. There are nine different CPU Modules each with its own display requirements. When the Display Module receives data from one of the nine CPU models, it automatically configures itself to display appropriate information. It is fully automatic with no task loading and no buttons. It even automatically turns itself on and off. At this time there are three different models available: “Lifeguard Display Module D1” for general individual diving use “Lifeguard Display Module D3” for wired surface supplied system tender on the surface “Lifeguard Display Module T1” for a dive supervisor with a dive team Each Display Module is powered by one user replaceable off-the-shelf 3v Lithium battery that typically provides two years of reliable operation in normal use. It can be powered by two “N” cells, but at a substantial reduction in battery life. There are no rechargeable batteries to wear out, and no battery chargers to lose. The life can be substantially less depending on the Taclite usage factor. If the Taclite is turned on 100% of the dive time, it should last for 50 dive hours. The battery voltage is shown on the Primary screen on the bar-graph in the left and should be monitored. When the battery voltage is at or below 2.90 volts the WARNING legend will start flashing along with the screen that shows the battery voltage, and the Taclite will not turn on. When the voltage is at or below 2.80 volts, the Module will continue to function if in a dive but will turn off as soon as the current dive is completed, and it will not turn on again until a new battery is installed. Each Display Module automatically turns on when it receives a data packet with the proper address. It can also be turned on manually by shorting contacts 1 and 2 with a metallic object such as a coin for two seconds. If the Module stops receiving packets and the contacts are not shorted, it automatically turns itself off after 30 minutes. © 2015 Cochran Consulting, Inc.

Lifeguard® Displays Tutorial Features Common to All Display Modules This Receiver-Display Module peripheral is typically worn on the divers wrist but is also available in hose-mount and retractor-mount configurations. The Model D1 (for OTS systems) and Model D3 (for Hytech systems) are also available in a Panel Mount for use with some Surface Supplied systems such as the Interspiro DP-1. The “Lifeguard Display Modules” have an on-demand LED backlight (“Taclite”) with user selectable colors: Red, Orange, or Amber. The Taclite is turned on by tapping or bumping the case and it turns on for ten seconds. This “Taclite Dwell Time” can be changed by the user. The trans-flective display can be seen in even the brightest sunlight. Depending on which one of the nine CPU Modules the Display Module is communicating with, there is one primary screen and one or two alternate screens. (To see what the various screens show refer to the User Manual or Tutorial for the specific CPU Module.) Tapping or bumping the Display Module case will sequence through the screens. If the Primary screen is currently showing, it will change to the first alternate screen showing more dive information. The Alternate screen will revert back to the Primary screen after four seconds. This time is called “Screen Dwell Time” and can be changed by the user. Note: when case is tapped or bumped, the Taclite will turn on and the first Alternate Screen will be shown at the same time. Display Module with all possible Segments showing © 2015 Cochran Consulting, Inc.

Lifeguard® Displays Tutorial Features Common to All Display Modules When the Display Module turns on, the screen shown to the right will appear. It indicates that it has passed all of its internal checks and has sufficient battery power to start a dive. The display will Start flashing after 10 seconds. Do not start a dive if this screen is showing! A typical normal Surface screen is shown to the right. The “SERVICE” legend being on indicates that the Display Module configuration is being updated to match the CPU Module. This usually takes less than One minute. Do not start a dive if the “SERVICE” legend is on! A typical Surface screen with WARNING is shown to the right. The “WARNING” legend means that some parameter(s) are out of range. Do not start a dive if the “WARNING” legend is on! Determine the Cause of the WARNING first. © 2015 Cochran Consulting, Inc.

Lifeguard® Displays Tutorial Features Common to All Display Modules © 2015 Cochran Consulting, Inc.

Lifeguard® Displays Tutorial Features Common to All Display Modules Note that when the WARNING legend is on, the parameter(s) that is causing the Warning is also flashing. Sometimes the parameter(s) may be on an Alternate Screen in which event Tapping the unit will show that Alternate screen and the flashing parameter(s). Sometimes more than one parameter may be flashing. The entire display flashing is an indicator that the Display Module is not communicating with its companion CPU Module. There are a number of reasons for this: The companion CPU Module is not turned on; The Display and CPU Modules don’t have the same address; The Display and CPU Modules are out of range of each other. Contact 3 Contact 2 Contact 1 There are a number of parameters in the Display Modules that can be changed by the user via Display Module Touch Programming: Acquire TxRx ID Number D1, D3 Taclite Dwell Time D1, D3, T1 Display Module Touch Programming is a feature whereby the user can view or change certain parameters within a Display Module in the field without any software. It involves shorting contacts 1 & 2 or contacts 2 & 3 with a metal object. Display Module Touch Programming functions only when the unit is turned on and NOT in a dive. The CPU Module also has Touch Programming and is described in the CPU Module Tutorial and manual. © 2015 Cochran Consulting, Inc.

Lifeguard® Displays Tutorial Features Common to All Display Modules Short contacts 1 and 2 with a coin starts Display Module Touch Programming and sequences through all of the programming options as shown below. Touching contacts 1 and 2 with a damp finger selects the digit you want to change. The selected digit will flash. Touching contacts 2 and 3 with a coin or damp finger will increment the digit up to nine and then back to zero. Moving from the current Touch Programming option to the next by shorting contacts 1 and 2 automatically tells the Display Module to remember the new number until it is changed again. Leaving the Touch Programming function occurs automatically after the last function was selected. If left in the Touch Programming mode without touching anything, the unit will exit the mode after one minute. First Touch Programming screen is the “Info” screen that shows the Display Module Battery Voltage “3.05” with an implied decimal point. Information shown on this screen cannot be changed. The second Touch Programming screen is the “Acquire ID” screen that allows the Display Module to capture the ID Number of the closest CPU Module. For this function, the normal range (one meter) of the system is reduced to 5 inches. The Display Module and its companion CPU Module must be less than 5 inches from each other. Touching contacts 1 and 2 with a damp finger takes you to the next screen where a zero appears in the right bottom digit as shown in the next screen. © 2015 Cochran Consulting, Inc.

Lifeguard® Displays Tutorial Features Common to All Display Modules As the Display Module captures a packet the digit will increment to four indicating it has captured four identical ID’s and will now remember the ID until it is changed again. The time (in seconds) the Taclight stays on after the case is tapped or bumped is called the “Taclite Dwell Time”. The number must be between 1 and 98. If the number is zero, the Taclite is disabled and will not turn on. If the number is 99, the Taclite will stay on permanently until you change it again. If the battery voltage is too low (=< 2.90 volts) the Taclite will not turn on and the audible warning will not sound. This is to preserve what little battery life is remaining. Note that battery life is inversely proportional to the amount of time the Taclite is on. © 2015 Cochran Consulting, Inc.

Lifeguard® Displays Tutorial Features Common to All Display Modules There are a number of parameters in the Display Modules that can changed by using its Touch Programming or the Analyst Version 5 PC software. Enter TxRx ID Number Analyst Only D1, D3, T1 Acquire TxRx ID Number Touch Programming Only D1, D3 Load Diver List Analyst Only T1 Taclite Dwell Time Analyst & Touch Programming D1, D3, T1 Taclite Color Analyst Only D1, D3, T1 Screen Dwell Time Analyst Only D1, D3, T1 Display Deco Time Total/Stop Analyst Only D1, D3, T1 Display Ceiling * 10 Analyst Only D1, D3, T1 Fixed/Proportional Ascent Rate Analyst Only D1, D3, T1 Restore Config to Factory Default Analyst Only D1, D3, T1 When using the Cochran Analyst PC Software, only the “Analyst 5” which was released in 2015 is compatible with the Lifeguard and other products released after 1 January 2015. See the Analyst 5 Tutorial for further information. © 2015 Cochran Consulting, Inc.

Lifeguard® Displays Tutorial LCD Receiver-Display Peripheral – D1 Model D1 Receiver and LCD Display The Lifeguard Display Module D1 the wireless, hoseless means by which the CPU Module communicates with the diver. It is fully automatic with no task loading and no buttons. It even automatically turns itself on and off. It has an on-demand LED backlight (“Taclite”) with user selectable colors: Red, Orange, or Amber. The Taclite is turned on by tapping or bumping the case and turns on for ten seconds. This “On Time” can be changed by the user. The trans-flective display can be seen in even the brightest sunlight. Lifeguard Display Module D1 must be one meter or less away from its companion CPU Module and have matching ID Numbers. Depending on which of the nine CPU Module models is being used, the D1 automatically assumes the personality of that specific module. It is powered by one user replaceable battery that typically provides up to two years of reliable operation. There are no rechargeable batteries to wear out, and no battery chargers to lose. © 2015 Cochran Consulting, Inc.

Lifeguard® Displays Tutorial LCD Receiver-Display Peripheral – D3 Model D3 Receiver and LCD Display The “Lifeguard Display Module D3” is functionally identical to the “Lifeguard Display Module D1”. However, the D3 is intended to be used in Surface Supplied and/or Comm Rope wired tethered systems. It is the Surface Tender Display and has a connector on the side that is wired to the Comm cable. This D3 Module on the surface shows exactly the diver’s dive parameters when the diver is in a dive. The D3 is primarily used with the Hytech wired communication system. While this D3 Module is splash proof, it must not be taken beneath the water surface. Contact Cochran for more details regarding Hytech, OTS, and other Surface Supplied and Tethered systems. © 2015 Cochran Consulting, Inc.

Lifeguard® Displays Tutorial LCD Teams Receiver-Display Peripheral - T1 The Teams Receiver-Display peripheral allows one diver to monitor the dive parameters of a number of divers in a “Team”. There can be any number of divers in a “Team” and any number of “Teams” on a given Mission. There is no cross-talk between Teams or Team Members. It is typically worn on the divers wrist but is also available in hose-mount and retractor-mount configurations. This is usually referred to as the “Lifeguard Team Module T1”. The Team Module receives data transmitted from any Lifeguard CPU Module that has matching addresses and are within a one meter radius of each other. This Team Display Module recognizes the nine CPU Module types it is communicating with and assumes its specific personality. Up to 64 unique addresses can be set into this Module so that it can recognize up to 64 Lifeguard CPU Modules. The Module is fully automatic with no task loading and no buttons. It even automatically turns itself on and off. It has an on-demand LED backlight (“Taclite”) with user selectable colors: Red, Orange, or Amber. The Taclite is turned on by tapping or bumping the case and turns on for ten seconds. This “On Time” can be changed by the user. The trans-flective display can be seen in even the brightest sunlight. It is powered by one user replaceable battery that typically provides up to two years of reliable operation. There are no rechargeable batteries to wear out, and no battery chargers to lose. Model T1 Multi-diver Teams Receiver and LCD Display © 2015 Cochran Consulting, Inc.

Lifeguard® Displays Tutorial Display Modules Battery The Lifeguard Computer Displays D1 and D3 Modules and Team Module T1 are powered by one user-replaceable Lithium battery three volt Type CR12600SE. With a fresh Lithium battery, the shelf-life of the Module is ten years. If diving, the battery life depends on the use of the backlight “Taclite”. If only occasionally using the Taclite, the batteries will last for over 1,000 hours of diving or two years, whichever occurs first. However, it is recommended to replace the batteries annually. If the Taclite is turned on for 100% of a dive, the battery life will be somewhat over 50 hours of diving. The Taclite turns on every time the case is tapped and the amount of time the Taclite stays on can be changed with the Analyst software or by using Touch Programming. From the factory, the Taclite Dwell Time is set for 10 seconds. For maximum reliability and battery life it is recommend to use Lithium batteries. However, Alkaline “N” cells will also work but at substantially reduced life and reliability. Battery voltage can be seen on the Lifeguard Display Module by using Touch Programming or the Analyst PC software. Note: The Lithium battery is non-magnetic and will not affect a compass. Most Alkaline “N” cells are magnetic. CAUTION: Never use the 12 volt battery that is similar in size to the 1.5 volt “N” Cell. © 2015 Cochran Consulting, Inc.

Lifeguard® Displays Tutorial Replacing Display Modules Battery The Lifeguard Computer Display and Team Modules battery is very easy for the user to replace as there are no chargers, wires, holders, or special tools needed. The battery has its own watertight compartment that is sealed from the electronics. The compartment is accessed by unscrewing its Cap with a coin (a US Quarter is supplied with the product). The Cap has two o-rings for watertight redundancy. The contacts in the Battery Caps and Compartments are of a unique metal that resists seawater corrosion. Should a compartment become flooded, immediately and thoroughly flush the compartment and cap with fresh water, let it dry, and replace the battery. Be sure to carefully inspect the Cap for debris before installing it. The Cap is a special material that is softer than the case material so that the Cap will be expelled should pressure build up within a compartment. CAUTION: Observe proper polarity when installing battery! The positive tip goes in first. Tighten battery cap until the o-rings cannot be seen. Never overtighten the cap. Only use the supplied U.S. Quarter or similar coin. Never use a screwdriver. © 2015 Cochran Consulting, Inc.

Lifeguard® Displays Tutorial Display Module Warranty and Support For Recreational use, the Cochran Lifeguard peripherals have a two year Limited Warranty. For Commercial and Military use it has a one year Limited Warranty. Download the Warranty details from our Website. All Models include USB interface and Standard Edition of the Analyst® PC Software. We are committed to professional, responsive support for the lifetime of our products. Phone during our office hours in Dallas, Texas 972.644.6284 or Email: Service@DiveCochran.com. Visit our Website for details. The Cochran Lifeguard Products can be purchased from Cochran or carefully selected Distributors and Dealers. © 2015 Cochran Consulting, Inc.

Lifeguard® Displays Tutorial © 2015 Cochran Consulting, Inc. ISO 9001:2008 Cochran Consulting Office: 972.644.6284 1758 Firman Drive FAX: 972.644.6286 Richardson, TX 75081 Websites: www.CochranConsulting.com www.DiveCochran.com www.CochranImagers.com www.CochranMilitary.com © 2015 Cochran Consulting, Inc.