1 2 Outline Airflow Measurements –How to take air readings –Measuring areas –Mean Entry Velocity Principals of Airflow When and Where to take Air Measurements.

Slides:



Advertisements
Similar presentations
Ventilation submitted by Christopher J. Bise
Advertisements

AIR DISTRIBUTION (Additional information. Also see Chapter 18) General The proper delivery of air for heating, cooling, or ventilation is a crucial part.
HVAC CONTROLS (See section 18.9)
Have We Really Learned From Our Mistakes? Jon Montgomery Ken Heintz Kevin Jones.
SAFETY TALK - SLIDE 1 OF 14 Elkhart Products Corporation 08/00 WELCOME ELKHART PRODUCTS CORPORATION “TOOLBOX SAFETY TALK” Welding, Cutting, & Burning.
Booster fan applications for sections in longwall and room-and-pillar mining Christopher Pritchard MS PE Acting Team Lead Ventilation Group Fires and Explosions.
UTILIZATION OF BOOSTER FANS IN UNDERGROUND COAL MINES
Welding, Cutting, & Burning. GENERAL HAZARDS General hazards of welding include: –Impact –Penetration –Harmful dust –Smoke –Fumes –Heat –Light radiation.
Local Exhaust Hoods. 2 Introduction:  Designed to capture and remove harmful emissions from various processes prior to their escape into the workplace.
Airflow Properties & Measurement
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
HOT WORK PROCEDURES Welding and Hot Work, such as brazing or grinding present a significant opportunity for fire and injury. CCR Title 8 Sub Chapter 7,
Dust Division Pittsburgh Safety and Health Technology Center Mark Schultz Senior Mining Engineer.
By Dr. Ahmed Mostafa Assist. Prof. of anesthesia and I.C.U.
Installing & Maintaining Irrigation Systems Ms. Gripshover Landscaping Unit 15.
Ventilation for Confined Spaces requires ventilation as follows: An employee may not enter the space until the forced air ventilation has eliminated.
Confined Space Ventilation Are We Really Moving Air, or Just Making Ourselves Feel Good?
Technical Study Panel on the Utilization of Belt Air and the Composition and Fire Retardant Properties of Belt Materials in Underground Coal Mining FINAL.
Belt Air Federal Advisory Committee Briefing Ronald Reagan Building Washington, DC January 9-10, 2007.
Unit 6.4. Filtration TB Infection Control Training for Managers at National and Subnational Level.
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
You will work in groups All groups play…In turn…Out of turn Scoring (In Turn)…Right – 4 chips Wrong – loss 2 chips Help…50/ chips… Ask the Group.
Felipe Calizaya Miles Stephens 2010 UTILIZATION OF BOOSTER FANS IN UNDERGROUND COAL MINES Stewart Gillies Univ. of Utah, Salt Lake City, UT Missouri Univ.
NFPA 54 National Fuel Gas Code Boiler Manufacturer ANSI Standards Local Codes Vent Manufacturer.
This presentation is for illustrative and general educational purposes only and is not intended to substitute for the official MSHA Investigation Report.
This presentation is for illustrative and general educational purposes only and is not intended to substitute for the official MSHA Investigation Report.
This presentation is for illustrative and general educational purposes only and is not intended to substitute for the official MSHA Investigation Report.
Final Rule SEALS April 18, Overview § Seal Strengths, Design Applications, and Installation § Seal Strengths, Design Applications,
Chapter 4. Subsurface Ventilation Systems Mine Ventilation and Safety Jiangxi University of Science and Technology 1 Review for Last Classes 
Blasting in Underground Bituminous Coal Mines Pennsylvania Bureau of Deep Mine Safety.
Contestant Briefing Hello I am ______and this is ________. You are to conduct a Pre-shift examination of the Bee No. 1 head gate section, for the oncoming.
AMERICAN COAL MINE SAFETY
Colorado Mine Rescue May 2015
Air Movement and Natural Ventilation
Drafts and Duct System Sizing
2015 Post No.5 & West Virginia State Mine Rescue Contest Day 2 Problem Briefing.
On-Shift Examination Scenario Continuous Miner Section What you will need: Pencil and paper to take notes or perform calculations Calculator to calculate.
Aug 1 st 2014 Mine Rescue Practice Problem Ole Smokey # 9 mine.
2015 Post No.5 & West Virginia State Mine Rescue Contest Day 1 Problem Briefing.
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
Dust Control Training Program for Underground Personnel
This presentation is for illustrative and general educational purposes only and is not intended to substitute for the official MSHA Investigation Report.
Mark J. Schultz, P.E. Chief, Environmental Assessment and Contaminant Control Branch Dust Division Mine Safety and Health Administration Pittsburgh Safety.
When a charged object is brought near a neutral object, it causes (induces) the electrons to shift in position The induced movement of electrons in the.
Belt Air Federal Advisory Committee Briefing Ronald Reagan Building Washington, DC January 9-10, 2007.
Problem Briefing 2013 Day 1 Problem Briefing ACA DAY 1 Statement You are located on the surface of RT #15 mine. This is a new highwall mine that.
Mine Emergency Preparedness Training Mine Recovery.
Pre-Shift Examination Scenario Continuous Miner Section What you will need to complete this exercise: Pencil and paper to take notes or perform calculations.
Indiana Mine Rescue Statement 2013 Thank your for assisting us with our emergency at the Vincennes No. 1 Mine. You are located at the fresh air base established.
This presentation is for illustrative and general educational purposes only and is not intended to substitute for the official MSHA Investigation Report.
Date - 01/02/2003 San Juan Coal Company Thermal Coal Customer Sector Group 1 #BHP Roof Control Jeopardy.
Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Diesel Particulate Matter DPM Compliance
SAFE WORK INSTRUCTIONS
Basics of Seed Conditioning
Who Wants to be a Miner? Sample Question You will work in groups
Workplace Examinations
38th 2014 Day 1 Problem Briefing Problem Briefing.
KCA Regional Skills Contest July 31, 2012 Mine Rescue Problem
Ventilating The Face Area
2016 KCA Regional Mine Rescue Skills April, 7th 2016
2015 KCA Regional Mine Rescue Skills April, 9th 2015
2016 Post 5 & West Virginia State Mine Rescue Contest Day 2
Low Velocity Air Measurements (timed smoke clouds) 14 sec 12 sec 13 sec 16 sec 13 sec 15 sec 14 sec 14 sec 13 sec 14 sec 14 sec 15 sec The time.
Roof Control Jeopardy.
2012 Mine Rescue Contest Day 2
2014 MTTC Pennsylvania Regional Skills Contest
2014 KCA Regional Skills Contest
2016 KCA Nationwide Skills Championship
Presentation transcript:

1

2 Outline Airflow Measurements –How to take air readings –Measuring areas –Mean Entry Velocity Principals of Airflow When and Where to take Air Measurements Actions for Excessive Methane

3 Three categories of Airflow Measurements Low Velocity (0 to 120 fpm) Medium Velocity (120 to 2000 fpm) High Velocity (>2000 fpm)

4 The principal mechanism for taking medium air velocity measurement is the Anemometer. A high speed anemometer is most often used for high velocity air measurements!

5 Taking Anemometer Measurements Make sure to zero dial! Make sure air flow is into the back of the anemometer. Press lever to start dial movement. Take reading for 1 Minute. Press lever to stop. For precise measurements, use a wand or extension rod to minimize effects of hand, arm, and body.

6 Traverse the whole entry when taking an anemometer reading. Start 15 Sec. 30 Sec. 45 Sec. End 60 Sec.

7 Take care to record correct dial reading. Dial Reading = 239 feet per minute.

8 Correct reading per correction chart. Correction factor = +43 Note Calibration Due Date Dial Reading = 239 Velocity = 282

9 Take multiple height measurements for irregular roof. 5’ 0” 6’ 6” Average Height = 5’ 6”

10 Estimate Gob Areas. 4 Feet 3 Feet Gob area = 1/2 * 3 *4 = 6 feet 2 Triangular shaped gob

11 Estimate area of obstruction! Crib area = 3 * 2.5 * 6 * 50% = 22.5 feet 2 Taking air reading between 3 rows of cribs. You have to estimate the effect of the cribs.

12 Narrow, high velocity openings may require you to take out the area of your body! Air velocity has an impact on the amount of obstructions you should consider! Remove 3 feet 2 for body and 3 feet 2 for timber!

13 Calculations Example 5’ 0” 6’ 6” Average Height = 5’ 6” Q = V A 20’ Area = 5.5 X = 110 ft ft. 2 = 104 ft. 2 Q = V A = 282 X 110 = 31,020 cfm 3 Feet 4 Feet Gob area = 1/2 * 3 *4 = 6 feet 2

14 Regulator Take Air Readings Upwind of Obstructions! Try to take air readings a few feet inby corners. Recommended locations to take air readings.

15 O.67 ft ft. 2 Area of block = 0.67 X 1.33 = 0.89 ft. 2 Area of Reg. = 8 X 0.89 = 7.2 ft. 2 If cannot take air reading upwind of regulator then take centerline reading in regulator and multiply by 0.9. Anemometer Reading = 100 fpm Velocity =100 X 0.9 = 90 fpm Q = 90 X 7.2 = 648 cfm

16 How to take smoke readings! It takes two! Measure how long it takes smoke to travel over a pre-determined distance! Best for upstream (smoker) to look down path of smoke with light. Divide distance traveled by time required to get the velocity. Multiply by 60 to get fpm. Example: 6 seconds to travel 10 feet. 10/6 = 1.67, 1.67 X 60 = 100 fpm

Divide the entry into quadrants to take smoke readings. The number of quadrants is flexible! OR take centerline reading and multiply by 0.9!

18 Mean Entry Velocity 1) Measure area behind curtain. 2) Take anemometer reading behind curtain. 3) Calculate airflow behind curtain. 4) Measure remaining area of entry. 4 ft. 5 ft. 16 Ft. 5) Divide airflow reading behind curtain by entry area. 4 X 5 = 20 Ft. 2 Velocity = 272 fpm 16 X 5 = 80 Ft X 20 = 5,440 cfm 5,440/80 = 68 fpm

19 Ventilation Tubing Area R2R2 Area = = 3.14 Pie are square!

20 Vent Tubing Example R2R2 Area = 24 inch Diameter Tubing Area = 3.14 X 1 2 Area = 3.14 ft. 2 Entry Area = 5 X = 97 ft ft. 5 ft. Anemometer reading = 2,350 fpm Mean Entry Velocity = 7,379/97 = 76 fpm Q=VA Q=3.14 X 2,350 Q=7,379 cfm

21

22 Airflow in a mine is induced by pressure differences between intake and exhaust openings.

23 The pressure difference is caused by imposing some form of pressure at one point or a series of points in the ventilating system. Exhausting Fan

24 The pressure created must be great enough to overcome frictional resistance and shock losses. Friction pressure losses are caused by the resistance of the walls on the airstream. Friction losses therefore depend upon the conditions and roughness of individual wall surfaces and velocity of air. Shock pressure losses are caused by abrupt changes on the velocity of air movement. Shock losses therefore are the result of changes on air direction or of airway areas, obstructions, and regulation.

25 Passageways, both intake and returns must be provided to conduct airflow

26 Airflow follows a square-law relationship between volumes and pressures, that is, twice the volume requires four times the pressure. 100,000 CFM 2 inches W.G. 200,000 CFM 8 inches W.G.

27 The pressure drop for each split leaving from a common point and returning to a common point will be the same regardless of the air quantity flowing in each split. R A B

28 Mine ventilation pressures, with respect to atmospheric pressures, may be either positive (blowing) or negative (exhausting). Total Pressure = Static Pressure + Velocity Pressure Static Pressure is the pressure exerted in all directions. Tire pressure is static pressure. Can be negative or positive. Velocity pressure is directional pressure. You feel velocity pressure when you feel the wind. VP is always positive. Exhausting fans are generally rated on Static Pressure. Blowing fans are generally rated on Total Pressure.

29 Air always flows from a point of higher to lower pressure. *Blowing fans create a high pressure point immediately inby the fan. Air travels from this high point through the mine to the surface. *Exhausting fans create a low pressure point immediately inby the fan. Air travels from the surface through the mine to this low pressure point.

30 Blowing Fan *Neutral flows to outside. Smoke will not travel to face area. *Gobs are “pressurized”. Less influx of contaminants from gobs until fan stops. *Harder to maintain required LOC quantities. *Best for mining near OLD WORKS.

31 Exhausting Fan *Neutral flows toward face. Smoke will travel toward face area. *Gobs are “under suction”. Contaminants flow from gobs until fan stops. *Easier to maintain required LOC quantities. *Worse for mining near OLD WORKS.

32 ExhaustingBlowing Face Ventilation  Higher velocity at face.  Best for gas.  Worse for dust.  Lower velocity at face.  Worse for Gas.  Good for Dust.

33

34 Section Pre-shift Examinations. C. During the pre-shift examination, the mine foreman shall determine the volume of air entering each of the following areas if a miner is scheduled to work in the areas during the oncoming shift: 1In the last open crosscut, which means the crosscut in the line of pillars containing the permanent stoppings that separate the intake and return air courses, of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed.

35 Section On-shift Examinations. C. Persons conducting the on-shift examination shall determine at the following locations which are underground: 1 The volume of air in the last open crosscut, which means the crosscut in the line of pillars containing the permanent stoppings that separate the intake and return air courses, of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed.

36 LOC Where is Last Open Crosscut? R

37 LOC Where is Last Open Crosscut? LOC R

38 Section Volume of Air. AThe quantity of air passing through the last open crosscut shall be not less than 9,000 cubic feet per minute; provided, however, that the quantity of air reaching the last open crosscut in pillar recovery sections may be less than 9,000 cubic feet per minute, if at least 9,000 cubic feet of air per minute is being delivered to the intake end of the pillar line. BThe air current at working faces shall under all conditions have a sufficient volume to readily dilute and carry away smoke from blasting and any flammable or harmful gasses.

39 LOC Where is Last Open Crosscut?

40 Where is Last Open Crosscut? LOC

41 Section Pre-shift Examinations. C. During the pre-shift examination, the mine foreman shall determine the volume of air entering each of the following areas if a miner is scheduled to work in the areas during the oncoming shift: 3The volume of air at the intake end of any pillar line 1where a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined, or 2if a split system is used, in the intake entries of each split immediately inby the split point.

42 Section On-shift Examinations. C. Persons conducting the on-shift examination shall determine at the following locations which are underground: 4The volume of air at the intake end of any pillar line 1where a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined, or 2if a split system is used, in the intake entries of each split immediately inby the split point.

43 Where is Intake End of Pillar Line? Intake

44 Where is immediately inby Split Point? Inby

45 LOC Where is Last Open Crosscut ?

46 Where is Last Open Crosscut ? LOC

47 Section Pre-shift Examinations. C. During the pre-shift examination, the mine foreman shall determine the volume of air entering each of the following areas if a miner is scheduled to work in the areas during the oncoming shift: 2On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan required by the federal mine safety law...

48 Section On-shift Examinations. C. Persons conducting the on-shift examination shall determine at the following locations which are underground: 2 The volume of air on a longwall or shortwall, including areas where longwall or shortwall equipment is being installed or removed, in the intake entry or entries at the intake end of the longwall or shortwall. 3 The velocity of air at each end of the longwall or shortwall face at the locations specified in the approved ventilation plan required pursuant to the federal mine safety law;

49 Where are Intake Air Readings required? Velocity Velocity locations as required by approved federal ventilation plan. Volume

50 Where are Intake Air Readings required? Volume Velocity Velocity locations as required by approved federal ventilation plan.

51 Section Weekly Examinations. D. At least every seven days, a certified person shall: 1Determine the volume of air entering the main intakes and in each intake split; 2Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns and where the air leaves the main returns; and 3Test for methane in the return nearest each set of seals immediately after the air passes the seals.

52 Section 1 Where are weekly air readings required? Main Intake LOC Main Return

53 Section 1 Section 2 Where are weekly air readings required? Main Intake Intake Split LOC Return Split Main Return

54 Section 1 Where are weekly methane test required? Main Return LOC Main Intake Methane Test

55 Section 1 Where are weekly Air Readings required? Main Return LOC Main Intake Top End Entrance to GOB R ML 1

56 Actions for Excessive Methane

Actions for excessive methane. Paragraph A ATests for methane concentration under this section shall be made by certified or qualified persons trained in the use of an approved detecting device which is properly calibrated. Tests shall be made at least twelve inches from the roof, face, ribs, and floor.

Actions for excessive methane. Paragraph B BWhen one percent or more methane is present in a working place or an intake air course, including an air course in which a belt conveyor is located, or in an area where mining equipment is being installed or removed, work shall cease and electrical power shall be de-energized in the affected working place at the equipment except intrinsically safe atmospheric monitoring systems (AMS).

59 Methane Example R 1.2 % 1. Stop Work in No Kill power to Miner.

Actions for excessive methane. Paragraph B Continued Changes or adjustments shall be made to the ventilation system to reduce the concentration to below one percent. Only work to reduce the concentration of methane below one percent shall be permitted. This does not apply to other faces in the entry or slope in which work can safely continued.

61 Methane Example R 1.2 % 1. Stop Work in No Kill power to Miner. 3. Adjust Ventilation.

Actions for excessive methane. Paragraph C CWhen one and one-half percent or more methane is present in a working place or an intake air course, including an air course in which a belt conveyor is located, or an area where mining equipment is being installed or removed, only work necessary to reduce the methane concentration to less than one and one- half percent will be permitted and all other personnel shall be withdrawn from the affected area. Electrically powered equipment in the affected area shall be de-energized and other mechanized equipment shall be shut off except of intrinsically safe atmospheric monitoring systems (AMS).

63 Methane Example 1.6 % R 2. Withdraw all other personnel. 1. Work to reduce CH4 concentration. 3. De-energize power.

64 R 1.8 % Methane Example 2. Withdraw all other personnel. 1. Work to reduce CH4 concentration. 3. De-energize power.

Actions for excessive methane. Paragraph D DWhen one percent or more methane is present in a return or split between the last working place on a working section and where that split of air meets another split of air, or the location at which the split is used to ventilate seals or worked out areas, changes or adjustments shall be made to the ventilation system to reduce the concentration of methane in the return air to less than one percent.

66 Section 1 Methane Example 1.2 % Changes or adjustments shall be made to the ventilation system to reduce the concentration of methane in the return air to less than one percent 1.2 %

Actions for excessive methane. Paragraph D When one and one-half percent or more methane is present in a return air split between the last working place on a working section and where that split meets another split or air or the location where the split is used to ventilate seals or worked-out areas, everyone except those persons required to perform necessary work to correct the problem shall be withdrawn from the affected area. Other than intrinsically safe atmospheric monitoring systems (AMS), all equipment in the affected area shall be de-energized at the source. No other work shall be permitted in the affected area until the concentration of methane in the return air is less than one percent.

68 Affected Area Active Section 1.8 % 2. All equipment in the affected area shall be de-energized at the source. 1. Withdraw everyone except those persons required to perform necessary work to correct the problem ! 3. No other work shall be permitted in the affected area until the concentration of methane in the return air is less than one percent

69 Active Section 1.9 % 2. All equipment in the affected area shall be de-energized at the source. 1. Withdraw everyone except those persons required to perform necessary work to correct the problem ! 3. No other work shall be permitted in the affected area until the concentration of methane in the return air is less than one percent

Actions for excessive methane. Paragraph G GThe concentration of methane in a bleeder split of air immediately before the air in the split joins another split of air, or in a return air course other than described in subsections D and E, shall not exceed two percent.

71 Active Section 2.5 % Methane Example 2. Changes or adjustments shall be made to the ventilation system to reduce the concentration of methane in the return air to less than one percent 1. Identify problem!

72