Good Laboratory Practices

Slides:



Advertisements
Similar presentations
The Role of the IRB An Institutional Review Board (IRB) is a review committee established to help protect the rights and welfare of human research subjects.
Advertisements

Tips to a Successful Monitoring Visit
PRINCIPLES OF A CALIBRATION MANAGEMENT SYSTEM
Radiopharmaceutical Production
© WHO – PSM Quality Control Laboratory Pharmaceutical Quality, Good manufacturing Practice & Bioequivalence Kiev, Ukraine October 2005 Maija Hietava.
Review Questions Business 205
Ensuring Better Services and Fair Value “Introduction and roadmap to implementation of ISO in Zambia’s water utilities” Kasenga Hara March 2015.
SOP Melody Lin, Ph.D. Deputy Director, Office for Human Research Protections Director, International Activities Santiago, Chile August.
World Health Organization
Laboratory Personnel Dr/Ehsan Moahmen Rizk.
Lecture 8. Quality Assurance/Quality Control The Islamic University of Gaza- Environmental Engineering Department Environmental Measurements (EENV 4244)
Regulatory Body MODIFIED Day 8 – Lecture 3.
QUALITY ASSURANCE IN BLOOD BANKING
Supplementary Training Modules on Good Manufacturing Practice
Quality Assurance/Quality Control Policy
FPSC Safety, LLC ISO AUDIT.
Quality Control Rutendo Kuwana Technical Officer, WHO, Geneva Training workshop: Training workshop on regulatory requirements for registration of Artemisinin.
ISO Standard is based on the management model of plan – do - check – act. Today we all be discussing the elements of the standard that deal with.
Top Tactics for Maximizing GMP Compliance in Blue Mountain RAM Jake Jacanin, Regional Sales Manager September 18, 2013.
Instructions and forms
Huzairy Hassan School of Bioprocess Engineering UniMAP.
© 2009 Michigan State University licensed under CC-BY-SA, original at Corrective Action.
Good Laboratory Practices (GLPs)
World Health Organization
Good Laboratory Practice
Regulatory Overview.
Approaches for forest certification System versus performance ? Presentation prepared by Pierre Hauselmann for the WWF / WB Alliance Capacity building.
GLP or Good Laboratory Practices
Good Manufacturing Practices
Project co-financed by European Union Project co- financed by Asean European Committee for Standardization Implementing Agency 1 Module 13 GMP Workshop.
Inspection Issues in the Analytical Laboratory: An FDA Perspective Yvonne McKnight Chemist US Food and Drug AdministrationPhone: x
1 Accreditation and Certification: Definition  Certification: Procedures by which a third party gives written assurance that a product, process or service.
MATTHEW MATKOVICH MINE EQUIPMENT COMPLIANCE SPECIALIST QUALITY ASSURANCE & MATERIALS TESTING DIVISION MSHA – APPROVAL & CERTIFICATION CENTER 30CFR, PART.
Good Manufacturing Practice. Good Manufacturing Practice Regulations Establishes minimum GMP for methods to be used, and the facilities or controls to.
Good Laboratory Practice CFR 21 Part 58 A Review for OCRA US RAC Study Group September 2005 Ginger Clasby, MS Promedica International
Michelle Groy Johnson Quality Improvement Officer Research Integrity Office Tough Love: Understanding the Purpose and Processes of Quality Assurance.
Important informations
Quality of Bioequivalence Data Alfredo García - Arieta Training workshop: Training of BE assessors, Kiev, October 2009.
This class cannot be shared or copied without the written permission of PracticeWorks Systems, LLC.
Proposed Rule for Preventive Controls for Animal Food.
Proposed Rule: 21 CFR 507 Proposed Rule for Preventive Controls for Animal Food 1.
QSR and GLP What exactly are these?.
OSHA – What to Expect When You’re Inspected (Following Federal Guidelines)
Copyright FDA Inspections: Where Do Things Go Wrong? Diana Naser RN, MS, CCRP Executive Director Clinical Research Administration Clinical Research.
Investigational Devices and Humanitarian Use Devices June 2007.
Final Rule for Preventive Controls for Animal Food 1 THE FUTURE IS NOW.
ISO Registration Common Areas of Nonconformances.
RIHES-II: H ANDLING A UDITS AND I NSPECTIONS E FFECTIVE D ATE 25 D ECEMBER 2006 V ERSION : 3.0 บุญเหลือ พรึงลำภู 15 มกราคม 2557.
Regulatory Issues in Laboratory Management
Most Common Deficiencies Cheryl O. Morton Managing Director, AIHA Laboratory Accreditation Programs, LLC.
Good Manufacturing Practice (GMP) Compliance: GMPs EXPLAINED.
1 CHALLENGES IN REGULATING QUALITY AND RATIONAL USE OF ANTIBIOTICS ALLIANCE FOR THE PRUDENT USE OF ANTIBIOTICS: INAGURAL MEETING COURTYARD.
Laboratory equipment Dr. W. Huisman Cairo, November 21th 2012.
Quality Control significance in pharmaceutical industry
CM&C Inspections The Pre-Approval Inspection (PAI) in the US 27 May 2010.
Good Laboratory Practices & Good Clinical Practices
Good Laboratory Practice - general information Pirkko Puranen Senior Inspector, Ph.D. Inspectorate.
Responsibilities of Test Facility Management, Study Director, Principal Investigator and Study Personnel G. Jacobs Belgian GLP Monitorate Zagreb, 17 December.
Storage, Labeling, Controlled Medications Guidance Training CFR § (b)(2)(3)(d)(e) F431.
BSB Biomanufacturing CHAPTER 4 GMP – Documentation Part I (SOP)
נמטוציטים משושנת ים Eli. S Lec. No.2.
ISO/IEC
Procedures and Good Laboratory Practices (GLPs)
Laws Relating to Accreditation, the use of NGABs, and Enforcement
Good Laboratory Practices
Good Laboratory Practices
Good Laboratory Practice CFR 21 Part 58
PREREQUISITE PROGRAMS
Radiopharmaceutical Production
OSU Controlled Substances Training Module for Researchers
Presentation transcript:

Good Laboratory Practices Lori Gladney Izabella Osakwe Endia Ford

GLP: GOOD LABORATORY PRACTICE GLP is an FDA regulation. Definition: GLP embodies a set of principles that provides a framework within which laboratory studies are planned performed, monitored, reported and archived. GLP is sometimes confused with the standards of laboratory safety like wearing safety goggles.

HISTORY GLP is a formal regulation that was created by the FDA (United states food and drug administration) in 1978. Although GLP originated in the United States , it had a world wide impact. Non-US companies that wanted to do business with the United states or register their pharmacies in the United States had to comply with the United States GLP regulations. They eventually started making GLP regulations in their home countries. In 1981 an organization named OECD (organization for economic co-operation and development ) produced GLP principles that are international standard.

WHY WAS GLP CREATED? In the early 70’s FDA became aware of cases of poor laboratory practice all over the United States. FDA decided to do an in-depth investigation on 40 toxicology labs. They discovered a lot fraudulent activities and a lot of poor lab practices. Examples of some of these poor lab practices found were Equipment not been calibrated to standard form , therefore giving wrong measurements. Incorrect/inaccurate accounts of the actual lab study Inadequate test systems

FAMOUS EXAMPLE One of the labs that went under such an investigation made headline news. The name of the Lab was Industrial Bio Test. This was a big lab that ran tests for big companies such as Procter and Gamble. It was discovered that mice that they had used to test cosmetics such as lotion and deodorants had developed cancer and died. Industrial Bio Test lab threw the dead mice and covered results deeming the products good for human consumption. Those involved in production, distribution and sales for the lab eventually served jail time.

OBJECTIVES OF GLP GLP makes sure that the data submitted are a true reflection of the results that are obtained during the study. GLP also makes sure that data is traceable. Promotes international acceptance of tests.

MISSION OF GLP Test systems Archiving of records and materials. Apparatus, material and reagent facilities. Quality assurance programs. Performance of the study. Reporting of study results. Standard operating procedures (SOP) Personnel and test facility organization

Standard Operating Procedures (SOP) Written procedures for a laboratories program. They define how to carry out protocol-specified activities. Most often written in a chronological listing of action steps. They are written to explain how the procedures are suppose to work

SOP Routine inspection, cleaning, maintenance, testing and calibration. Actions to be taken in response to equipment failure. Analytical methods Definition of raw data Keeping records, reporting, storage, mixing, and retrieval of data

Statistical Procedures for Data Evaluation Statistical procedures are not simply chosen from a text book Practitioners in a particular field may adopt certain standards which are deemed acceptable within that field. Regulatory agencies often describe acceptable statistical procedures.

Instrumentation Validation This is a process necessary for any analytical laboratory. Data produced by “faulty” instruments may give the appearance of valid data. The frequency for calibration, re-validation and testing depends on the instrument and extent of its use in the laboratory. Whenever an instrument’s performance is outside the “control limits” reports must be discontinued

Instrument Validation (cont) Equipment records should include: Name of the equipment and manufacturer Model or type for identification Serial number Date equipment was received in the laboratory Copy of manufacturers operating instruction (s)

Reagent/ Materials Certification This policy is to assure that reagents used are specified in the standard operating procedure. Purchasing and testing should be handled by a quality assurance program.

Reagents and Solutions cont Requirements: Reagents and solutions shall be labeled Deteriorated or outdated reagents and solutions shall not be used Include Date opened Stored under ambient temperature Expiration date

Analyst Certification Some acceptable proof of satisfactory training and/or competence with specific laboratory procedures must be established for each analyst. Qualification can come from education, experience or additional trainings, but it should be documented Sufficient people Requirements of certification vary

Laboratory Certification Normally done by an external agency Evaluation is concerned with issues such as Adequate space Ventilation Storage Hygiene

Specimen/Sample Tracking Vary among laboratories Must maintain the unmistakable connection between a set of analytical data and the specimen and/or samples from which they were obtained. Original source of specimen/sample (s) must be recorded and unmistakably connected with the set of analytical data.

Documentation and Maintenance of Records Maintenance of all records provide documentation which may be required in the event of legal challenges due to repercussions of decisions based on the original analytical results. General guidelines followed in regulated laboratories is to maintain records for at least five years Length of time over which laboratory records should be maintained will vary with the situation

Important questions to be answered for any analytical instrument What is the equipment being used for? Is the instrument within specification and is the documentation to prove this available? If the instrument is not within specifications, how much does it deviate by? If the instrument is not within specifications what action has been taken to overcome the defect? Can the standards used to test and calibrate the instrument be traced back to national standards?

What happens if a workplace does not comply with federal Good Laboratory Practice standards?

Disqualification of a Facility Before a workplace can experience the consequences of noncompliance, an explanation of disqualification is needed The FDA states the purpose of disqualification as the exclusion of a testing facility from completing laboratory studies or starting any new studies due to not following the standards of compliance set by the Good Laboratory Practice manual

Possible Violations Falsifying information for permit, registration or any required records Falsifying information related to testing~ protocols, ingredients, observations, data equipment, ect. Failure to prepare, retain, or submit written records required by law

Grounds for Disqualification The testing facility failed to comply with one or more regulations implemented by the GLP manual The failure to comply led to adverse outcomes in the data; in other words, it affected the validity of the study Warnings or rejection of previous studies have not been adequate to improve the facility’s compliance

Consequences of Noncompliance The FDA states the following consequences of noncompliance: The commissioner will send a written proposal of disqualification to the testing facility A regulatory hearing on the disqualification will be scheduled If the commissioner finds that after the hearing, the facility has complied, then a written statement with an explanation of termination of disqualification will be sent to the facility Thus, if it can be shown that such disqualifications did not affect the integrity and outcome of the study itself, or did not occur at all, then the study may be reinstated at the will of the commissioner

Upon Disqualification… If the commissioner finds that the facility was noncompliant on any of the grounds after the hearing, then a final order of noncompliance will be sent to the facility with explanations If a testing facility has been disqualified, any studies done before of after the disqualification will need to be determined as essential to a decision (acceptable or not) If the study is determined unacceptable, then the facility itself may need to show that the study was not affected by the noncompliance that led to the disqualification Once finally disqualified, the facility may not receive or be considered for a research or marketing permit and the study is rejected.

Upon Disqualification… The commissioner may notify the public and all interested persons, including other federal agencies the facility may have contacted The FDA may ask the other agencies to consider whether to support the facility or not under the disqualification Civil or criminal proceedings may occur at the discretion of the commissioner Fines of up to $50,000 if one knowingly commits crime and/or 1 year imprisonment~ for registration applicants and producers Fines up to $5,000 all others~ civil penalty after failing to improve after a minor violation warning was issued~ only those involved in testing will be given civil penalties Those involved in the distribution or sales will be assessed more heavy penalties, such as criminal penalties

Upon Disqualification… The FDA may turn it over to the federal, state or local law enforcement The facility’s sponsor may terminate or suspend the facility from doing any non- clinical study for a permit The sponsor is required to notify the FDA in writing within 15 working days that the facility is to be suspended or terminated and why

Reinstatement of a Disqualified Facility The testing facility may be reinstated as acceptable non-clinical study to be turned into the FDA if the commissioner can be certain that future studies will be conducted in compliance with the Good Laboratory Practice standards and that any current studies integrity have not been severely harmed by the disqualification The disqualified facility will be required to put in writing to the commissioner reasons why it should be reinstated and any actions the facility will take or have taken to assure any disqualification problems will not happen again

Reinstatement of a Disqualified Facility The commissioner will inspect the facility and determine if it shall be reinstated If it is reinstated, the commissioner is required to notify all persons that were notified of the disqualification including the facility itself

References http://www.sjsu.edu/faculty/chem55/55glpout.htm http://www.labcompliance.com/tutorial/glp/default.aspx?sm=d_a UGA Office of the Vice President for Research Wikipedia