INTRODUCTION TO T&T ELECTRICAL WIRING CODE TTS 171: PART 1: 2002

Slides:



Advertisements
Similar presentations
Control Circuit Protection Supplementary Protectors vs
Advertisements

Bonding and Grounding What? Why? How?
The Electrical GuruTM Paul W. Abernathy,CME
BS7671 Formula and Tips.
Electrical Safety Basic Electrical Safety Rafael Coll, Environment Safety and Health Section Health& Safety Group Ext Pager: (630)
Stray Current Investigations A Method of Troubleshooting Stray Current on Underground Residential Distribution (URD) Loops Stacey Mighty Malcolm Distribution.
EE4503 Electrical Systems Design
Inspection & Test Overview suite412.
OSHA Office of Training and Education
FIRE PUMP ELECTRICAL CONFIGURATIONS UNDER 600 VOLTS.
CIRCUIT ARRANGEMENT (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation Handbook,
 Recognize the scope and structure of the OSHA standards.  Identify the common electrical hazards in long term care settings.  Discuss electrical safety.
Controlling Hazardous Energy
Electrical Power Systems
Construction Methods and Materials Electric Electric.
Occupational Safety and Health Course for Healthcare Professionals.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE.
Hazard - Inadequate Wiring
Bonding, Grounding and the NEC  Presented by The National Association of Certified Home Inspectors
Chapter 4 – Ohm’s Law, Power and Energy Introductory Circuit Analysis Robert L. Boylestad.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
By Carlin Bright. Electricity The flow of electrons in a conductor.
BUILDING TRADE SAFETY ELECTRICAL SAFETY.
Physiological Effects of Electricity on Human Body by Mohd Yusof Baharuddin.
ELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S
Tom Kader Chief Electrical Inspector Spaces About Electrical Equipment Sufficient access and working space shall be provided and maintained about.
Protection against Electric Shock (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation.
Electricity at Work.
Objectives Review electric circuits and electricity pricing - Introduce HW5 Select conductor and conduit List electrical devices.
ELECTRICAL HAZARDS Electricity is an essential of modern life Some work directly with electricity (Engineers, circuit assemblers) Some work indirectly.
MINIMUM ACCEPTABLE LEVELS OF SAFETY & RELIABILITY
Electrical Installation 2
TTS 171 : PART 1: 2002 ANNEX E PRESENTER WINSTON THOMAS ELECTRICALINSPECTOR 1 ELECTRICAL INSPECTOR 1.
EXAMPLE ELECTRICAL DESIGN OF A SMALL OFFICE
Grounding, bonding, and ground fault currents
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
Copyright  Progressive Business Publications Electrical Safety.
Objectives Review conductor and conduit selection Learn about protection systems (basic rules) Learn to design Residential Electrical Systems.
PORTABLE & TRANSPORTABLE ELECTRICAL EQUIPMENT. Legal Requirement and References Abu Dhabi RSB Electrical Regulations - makes reference to the need to.
Introduction to switchgears
Suggestion on How to Use
Electrical Safety, Subpart K
Testing of Low Voltage Installations
The two types of electricity used in mining are: “AC” or alternating current and “DC” or direct current.
Craig T. Riesen Energy Workshop II 1 Electricity & Generation Basics of Electricity and Electrical Transmission Transmission Generation electrons.
Installation of Heating, Cooling, and Refrigeration Systems Electricity for Refrigeration, Heating and Air Conditioning 7th Edition Chapter 8 Installation.
ELECTRICAL WIRING WIRING BASICS Written by Bobby Joslin
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
UTH-65A VER. CAUTIONS ! PLEASE USE THE OUTLET PREPARED BY A QUALIFIED SERVICEMAN AND MUST CONFIRM IT BEFORE APPLY[SING AN ELECTRIC CURRENT.
Electrical Safety Basic Electrical Safety. Electrical Safety  Course not designed to teach you to work on electrical equipment. Basic Electrical Safety.
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
4.0 DOMESTIC ELECTRICITY Domestic electricity is that electricity which is supplied to homes under specific conditions of current and voltage. Voltage,
Special-Purpose Outlets— Electric Heating, Air Conditioning
Basic Electrical Safety
Smitty’s Two Minute Drills
ESTIMATING AND COSTING OF DOMESTIC INSTALLATION
Personal Protective Equipment
ANNEX E PRESENTER WINSTON THOMAS
Engineering Project Cable Management.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Smitty’s Two Minute Drill #1: Feeders and Branch Circuits
Overcurrent Protection— Fuses and Circuit Breakers
Agenda Introduction of Protective Relays
EET 323 – Electrical System Design Lecture 9: Grounding
Conductor A material, such as copper, that permits the flow of electricity; usually refers to the a wire.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Basic Electrical Safety
Basic Electrical Safety
Objectives Learn about Electricity Pricing Electric systems.
Electrical components and systems
Presentation transcript:

INTRODUCTION TO T&T ELECTRICAL WIRING CODE TTS 171: PART 1: 2002 By GEORGE SAMPSON ELECTRICAL INSPECTOR III GOVERNMENT ELECTRICAL INSPECTORATE

What is the T&T Wiring Code? Revised edition of TTS: 26 20 505-1978 REQUIREMENTS FOR THE ELECTRICAL WIRING OF BUILDINGS AND EQUIPMENT More Comprehensive Additional technical information.

WHO BENEFITS? AREAS Designing Planning Electrical Fraternity members and clients AREAS Designing Planning The actual installation of a wiring system

SCOPE COVERS: Installations up to 600 volts NOT COVERED: Installations operated by Authorities for the Generation & Distribution of electrical power such as: Powergen InnCogen T&TEC

ENFORCEMENT HOW? The CEI is the authority with jurisdiction Interpretation Enforcement of this standard

CONFLICT If ever, any conflict arises between TTS 171 and any other standard, the CEI shall be the sole arbitrator and his decision shall be final

WHAT’S NEW? The terminologies are in harmony with international standards Examples 2002 1978 Ground Earth Grounding Conductor Earth Continuity Conductor Grounding Electrode Conductor Earthing Lead (MEC) Receptacle Outlet Socket Outlet

WHAT’S NEW ? ( Cont’d ) Ground Fault Circuit Interrupter & Ground Fault Protection of equipment are also new to the list of definitions.

ANNEX C Revision of TTS 1978 ( Table 21 ) Guidelines on sub-circuit requirements for: Residential Commercial Industrial Installations

Simple Formulae and Worked Example for voltage drop calculation ( section D.1.7.3) New to this standard It was included to assist with the application of the Voltage Drop Tables

ANNEX E Maximum conductor fill for Conduits & Boxes Consider a practical case: Install the following conductors within a common raceway: 6 x 1.5mm sq. 8 x 2.5mm sq. 4 x 6.0mm sq. 6 x 4.0mm sq.

Comply with section 6.2.7 A space factor of 40% is not to be exceeded. The cables are not to be damaged. No more than two ( 2 ) 90 degrees bends are allowed along the conduit work.

DISTRIBUTION AND PROTECTION (Section 4.1.1) Every consumer’s installation shall be adequately controlled by a service disconnect. i.e. Main Switch or Circuit Breaker Does this requirement apply to systems utilizing standby power from a Generator?

The CEI requires that all wiring systems are to comply with section 4 The CEI requires that all wiring systems are to comply with section 4.1.1 whether they utilize a standby Generator or not. In addition, those with standby power must incorporate suitable Transfer Equipment.

Why Transfer Equipment? This is to prevent the inadvertent or accidental interconnection of the normal (T&TEC) and the standby ( Generator) sources of power.

HIGHLIGHTS FROM OTHER SECTIONS OF THE CODE

MARKINGS Section 3.10.1 requires each piece of electrical apparatus and material to bear such markings to identify it To ensure its suitability for the particular application

Examples of Markings Manufacturers’ name, trademark, or other recognized symbols of identification Rated load in amperes Rated frequency or frequency ranges in hertz Whether for continuous load or intermittent

Consequences of failure to conform to technical data Persons could receive a severe electric shock Explosion or fire may occur Serious injury may occur from a fall or flying objects Electrocution is also a very, very real possibility

The foregoing are sufficient reasons to be meticulous when selecting equipment and materials.

GROUNDING ELECTRODE CONDUCTOR & GROUNDING CONDUCTOR

Why should we give the Grounding Electrode Conductor and the Grounding Conductor the respect they deserve?

Three basic reasons for grounding Limits the voltage caused by lightning, or by accidental contact with conductors of higher voltages. Stabilizes the voltage under normal operating conditions - to maintain the voltage at one level relative to ground so equipment connected to the system is subjected only to that potential difference. Facilitates the operation of over current devices such as fuses, circuit breakers or relays under ground fault conditions.

Selection and application of: The Grounding Electrode Conductor and the Grounding Conductor deserves our keenness attention Sizes of grounding conductors ( Sec 9.5 ) See Current Ed. Of NFPA 70 Tables 250-66 and 250-122

APPARATUS IN GARAGES (Section 8.5) Where motor-driven vehicles are: Stored Serviced Repaired All apparatus shall, unless of a totally enclosed or flameproof type, be installed at a minimum height of 1200mm ( 4ft ) above the general floor level.

SEGREGATION OF CIRCUITS (Section 5.23 ) Lighting and power cables operating at voltages above extra-low ( i.e.exceeding 50 V a.c. or 120 V d.c. whether between conductor or to ground). Shall not be drawn into the same conduit or duct as cables of extra-low voltage or of radio systems. Unless the latter are insulated for the higher voltage present.

Note: Failure to observe these guidelines may result in Electromagnetic Induction (EMI ) and disruption of the extra-low voltage equipment.

RACEWAY INSTALLATIONS (section 6.1.1) Conduit works shall be completed before any cables are drawn in. Ends shall be reamed and bushed to avoid abrasion. Inspection boxes shall remain accessible throughout the life of the installation.

TESTING AND INSPECTION (Section 10 ) To determine what malfunctions are possible To determine what protection is necessary and sufficient To minimize the ill-effects of such malfunctions

Section 10.1.1 Requires that every new installation and any alteration to an existing installation shall be inspected and tested to ensure compliance with TTS 171

Inspection and Testing Involves: Visual examination of workmanship Verification of polarity (I.R.test) Effectiveness of grounding Continuity A verification of polarity shall be made to ensure that all fuses, circuit breakers and single pole control devices, are connected to live conductors only.

Since ground fault protection relies on operation of fuses or circuit breakers, the resistance or impedance between the electrode and the remote end of every grounding conductor, shall not exceed 1 ohm. Where metal conduit forms part or whole of the grounding conductor, the above shall also apply.

Electrical Metallic Tubing ( EMT ) Shall be protected against any risk of mechanical damage. Not to be exposed to rain, dripping water, condensation, oil, corrosive substances and hazardous location. Not bend, as to damage the tubing or to effectively reduce its internal diameter. Not be buried directly in the ground.

CONTROL OF MOTORS (Section 8.12.2) Each motor and its control equipment shall have a disconnecting means. For remote disconnecting means: an additional means of isolation adjacent to the motor shall be installed OR a lockout device shall be installed adjacent to the motor The remote means of isolation shall be able to be locked in the off-position.

Conclusion Section 3.1.2 reads in part: This standard contains minimum provision considered necessary for safety, but is not to be regarded as a design specification or an instruction manual for untrained persons.

THE END