Ventilator Check It’s a thorough process that should take longer than 2 minutes!

Slides:



Advertisements
Similar presentations
Patient – Ventilator Asynchrony
Advertisements

Trouble Shooting (Mechanical Ventilation)
Initial Assessment of the Mechanically Ventilated Patient
Improving Oxygenation
1 Pre-ICU Training CHEST Mechanical Ventilatory Support 2008/6/20.
Mechanical Ventilaton Ramon Garza III, M.D.. Indications Airway instability Most surgical patients or trauma Primary Respirator Failure Mostly medical.
“… an opening must be attempted in the trunk of the trachea, into which a tube of reed or cane should be put; you will then blow into this, so that the.
Mechanical Ventilation in the Neonate RC 290 CPAP Indications: Refractory Hypoxemia –PaO2 –Many hospitals use 50% as the upper limit before changing.
Resistance. What is Resistance? Resistance is a measurement of the frictional forces that must be overcome during breathing. It can also be described.
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
Accelerated Ventilator Weaning Guideline A path to excellence! Click Here A path to excellence! Click Here.
Troubleshooting and Problem Solving
Ventilator and Practical Review Nov 2006 Kishore P. Critical Care Conference.
Ventilator Graphics: Not Just Pretty Lines
Initiation of Mechanical Ventilation
J. Prince Neelankavil, M.D.
Initial Ventilator Settings
Ventilators for Interns
Department of Critical Care Medicine Kovai Medical Center and Hospital.
Mechanical Ventilation Tariq Alzahrani M.D Assistant Professor College of Medicine King Saud University.
New Protocols for 2006 Protocols: Provide consistent predictable care for 90% of patients Development of protocols is a dynamic and ongoing process.
Objectives Discuss the principles of monitoring the respiratory system
Understanding Oxygen Therapy in less than an Hour
Principles of Mechanical Ventilation
Mechanical Ventilation Management
Building a Solid Understanding of Mechanical Ventilation
MECHANICAL VENTILATION
MECHANICAL VENTILATION
1 Elsevier items and derived items © 2010 by Saunders, an imprint of Elsevier Inc. Chapter 19 Mechanical Ventilation of the Neonate and Pediatric Patient.
Trouble Shooting (Mechanical Ventilation) Arthur Sadhanandham Medical ICU, CMC.
Vents 101 Ted Lee,MD. Objectives Understand the basics of vent mechanics Describe the various modes of ventilation Learn how to initiate mech. ventilation.
Setting the Vent & Problems. 2 Aspects Oxygenation Ventilation.
Dr Chaitanya Vemuri Int.Med M.D Trainee.  The choice of ventilator settings – guided by clearly defined therapeutic end points.  In most of cases :
Final Considerations in Ventilator Setup Chapter 8.
Weaning and Discontinuation of Ventilatory Support
Passy Muir Valve Speaking Valve for Tracheostomy Patients Deidre Dennison, RN Vascular Intensive Care How it WorksContraindications Benefits InitiationMaking.
Emídio Lima MD, PhD. Mortality Increases with the Duration of Mechanical Ventilation and Weaning Failure.
Ventilator Graphics Chapter 10. Graphics Monitor the function of the ventilator Evaluate the patient’s response to the ventilator Help the clinician adjust.
1 Mosby items and derived items © 2010 by Mosby, Inc., an affiliate of Elsevier Inc. Chapter 14 Respiratory Monitoring in the Intensive Care Unit.
Discontinuation and Weaning from Mechanical Ventilation
CLINICAL ALGORITHM FOR THE MANAGEMENT OF INTUBATED PATIENTS PRESENTING WITH CHANGES VISSIBLE ON CxR Next step in the algorithm.
BASICS OF WAVEFORM INTERPRETATION Michael Haines, MPH, RRT-NPS, AE-C
Ventilator Management James Eakins, MD FACS Director, Trauma and Surgical Critical Care Hahnemann University Hospital.
Ventilator Graphics Emeritus Professor Georgia State University
Mechanical Ventilation 1
WEANING The Discontinuation of Ventilatory Support By Adriana Adams and Cesar Mancillas.
ESSENTIALS OF VENTILATOR GRAPHICS
1 Elsevier items and derived items © 2010 by Saunders, an imprint of Elsevier Inc. Chapter 20 Neonatal and Pediatric High-Frequency Ventilation.
3 nd LECTURE VENTILATORS Part One. Ventilators One of the major life support systems. Ventilators take over the vital role of the respiratory muscles.
APPROACH TO ASSESSMENT AND WEANING OFF THE MECHANICAL VENTILATOR AT THE BEDSIDE DR. MUNIRA DILAWER GHEEWALA.
Cenk Kirakli, MD ; Ilknur Naz, PT, MS ; Ozlem Ediboglu, MD ; Dursun Tatar, MD ; Ahmet Budak, MD ; and Emel Tellioglu, MD A Randomized Controlled Trial.
Principles of Mechanical Ventilation Mazen Kherallah, MD, FCCP.
PRESSURE CONTROL VENTILATION
Ventilators for Interns
Weaning From Mechanical Ventilation
Mechanical Ventilation
Mechanical Ventilation
Pressure Regulated Volume Control Mode
Vents 101 Ted Lee,MD.
Mechanical Ventilation - Introduction
Introduction to Basic Waveforms
Promoting Oxygenation
Mechanical Ventilation
Mechanical ventilator
“Top Ten” Session Review for Mechanical Ventilation Modes
Mechanical ventilation .
Introduction to ventilation
Mechanical ventilator
Transport Ventilator and Beyond!
MECHANICAL VENTILATION
Presentation transcript:

Ventilator Check It’s a thorough process that should take longer than 2 minutes!

Step 1-Chart Review Verify Current ventilator settings with physicians orders Insure correspondence between the MD orders and actual values given in report and that are on the ventilator Contact MD for discrepant values Check orders for ventilator changes, ABGs…. Check current medications (sedation, blood presser medications, antiobiotics…)

Step 1- Chart Review Look at patients CXR, note tube placement Look at patients CBC and C/S results Look at last ABG result Read H & P, read pulmonary consult Know what the general plan is for the patient – Ex: weaning? Continue vent as is?...

Step 2-entering room You should have a good idea about why your patient is on the vent from report and chart review before actually seeing your patient Wash hands/gloves Enter room, assess the patient and ventilator by inspection first – Note medications hanging by IV – Note presence of a feeding tube – Note the monitor for HR, SpO2, BP, hemodynamics parameters – Look at the patient, note if they are awake/sedated

Step 2- entering the room Note if family is in the room, explain who you are and what you are doing Only comment on matters regarding the ventilator or respiratory, no lab tests… Now assess patient. First look at the vent circuit, if patient is on a humidifier you may have to drain the tubing, note water level on huidifier and refill as needed

Step 3- Pt. Assessment Note patients chest movement, tape on ETT and tube marking at lip or gum Re-tape as needed Change HME as needed Check MOV/MLT Check patient’s breath sounds, general appearance, chest movement

Step 4- Ventilator Check Note Heart Rate, SpO2, ECG tracing, BP on monitor, PETCO2, record where appropriate Check circuit for leaks, integrity On Ventilator monitor/record: – Ventilator settings (ensure they are what was ordered). Mode, FIO2, VT/PC, breath type, PEEP, I- time/flow, Alarms (adjust alarms as needed)

Step 4 Ventilator check Ventilator monitored data: – PIP (if high note increases in RAW/fix) – Total rate (if high note presence of fever, hypoxemia, anxiety/aggtation, low Vt) – Total PEEP (if higher than set= auto peep) – MAP (normal 10-12, increased = decreased compliance, higher distending pressures, set PEEP is high) – VTE / VTI (look for difference, if greater than +/- 50 may be a leak) – FIO2 (if analyzer is way off, take vent out of service for repair)

Step 4 Ventilator check Note graphics: – FLOW/TIME: assess for aitrapping – PRESSURE/TIME: assess for over distension, time it takes to reach pressure – VOLUME/TIME: Note if patient is receiving adequate flow on inspiration – PRESS/VOLUME LOOP: note compliance – FLOW/VOLUME LOOP: Note obstructive patterns

Step 4 Ventilator check Perform lung mechanics: – Inspiratory hold to get Static Compliance – Expiratory hold to get Auto-PEEP – RAW calculation

Step 4-Ventilator Check Suction patient as needed (noted by breath sounds, PIP and airway graphics) Give breathing treatment after all checks are done (adjust alarms as needed for treatment delivery)

Communication When you make a change to the ventilator, share your change with the RN The doctor should have been the one giving you the order to change the vent, however if not, share change with the MD as well During rounds (if they are present at the hospital you go to) communicate your ventilator settings and YOUR plan or recomendation

Troubleshooting High PIP (safety valve opens) – Agitation (sedation? Pain meds? Change in mode?) – Increase in airway secretions, suction/bronch – Bronchospasm- broncho dilator – Biting ETT (bite block) – Patient talking/coughing/holding breath

Troubleshooting Low VTE/low PIP: – Look for obvious leaks – Does the patient have a chest tube – Note cuff integrity – Did the patient self extubate – Is the patient on spontaneous mode without proper PSV or support

Troubleshooting High Rate/high Ve: – Pain, agitation, fear/anxiety? – Fever? – Low volumes? – Compensation for Metabolic acidosis? – Do they need sedation, change in mode, increased flow?

Troubleshooting Low rate: – Over sedated? – Compensating for a metabolic alkalosis? – Over ventilated with high Vte – Atrophy of diaphragm? – Neuromuscular impairment?

Weaning Weaning is done when parameters of interest improve. For example oxygenation improves as demonstrated by ABG and SpO2. Wean FIO2 down in increments tolerable by patient. – Wean to 60% first, then begin weaning PEEP – Wean to a minimum of about 40% before extubation is considered

Weaning Patients underlying condition must be improved or improving Look at CXR, labs and physician notes Note if patient is on sedation Note hemodynamic stability, should be off pressers Patient obviously should have drive and ability to breathe, and ability to cough

Weaning Note weaning parameters: – MIP – MEP – VC – RSBI – Vital signs within acceptable parameters – ABG within patient’s normal limit – Cuff pressure is normal

Weaning Strategies: – SBT (spontaneous breathing trials) – Taper down support (wean rate, change to less controlled modes- SIMV then Spontaneous modes) – Give minimum PSV or use ATC/VS – Extubate to BiPAP