Chapter 7 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

Slides:



Advertisements
Similar presentations
Since Therefore Since.
Advertisements

Chapter 12 RL Circuits.
Sinusoidal Steady-State Power Calculations
Alternating Current Circuits
AC Power: instantaneous and average power
The average ac power (P av ) is the power dissipated on the load resistor. 0  cos  1, dependent on the complex load. ideal power factor: cos  =1,
Filter & Transfer Function Z1Z1 Z2Z2 V in V out To determine filter type, look how H V as a function of frequency Z 1 and Z 2 could include multiple components.
AC Power: average power
AC Review Discussion D12.2. Passive Circuit Elements i i i + -
Announcements Be reading Chapters 1 and 2 from the book
Copyright © 2013 The McGraw-Hill Companies, Inc. Permission required for reproduction or display. 1 Chapter 11 AC Circuit Power Analysis.
Balanced Three-Phase Circuits
Lesson 24 AC Power and Power Triangle
1 ECE 3336 Introduction to Circuits & Electronics Set #16 Transformers Fall 2012, TUE&TH 4:00-5:30 pm Dr. Wanda Wosik.
Storey: Electrical & Electronic Systems © Pearson Education Limited 2004 OHT 16.1 Power in AC Circuits  Introduction  Power in Resistive Components 
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
Lesson 26 AC Power and Power Factor
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
Alexander-Sadiku Fundamentals of Electric Circuits
Fundamentals of Electric Circuits Chapter 11
Chapter 4 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Alternating Current Circuits
Chapter 31 Electromagnetic Oscillations and Alternating Current Key contents LC oscillations, RLC circuits AC circuits (reactance, impedance, the power.
Electromagnetic Oscillations and Alternating Current
Copyright © 2009 Pearson Education, Inc. Chapter 30 Inductance, Electromagnetic Oscillations, and AC Circuits.
5.4 Circuit Analysis Using Phasors and Complex Impedances
Alternating Current Circuits
Fundamentals of Electric Circuits Chapter 11
Power in AC Circuits ELEC 308 Elements of Electrical Engineering
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Fourth Edition, by Allan R. Hambley, ©2008 Pearson Education, Inc. Lecture 16 Phasor Circuits, AC.
EGN 3373 Introduction to Electrical Systems I A Systems Approach to Electrical Engineering Graphics Adapted from “Physical, Earth, and Space Science”,
1 Chapter 11 AC Power Analysis 電路學 ( 二 ). 2 AC Power Analysis Chapter Instantaneous and Average Power 11.2Maximum Average Power Transfer 11.3Effective.
AC POWER ANALYSIS Instantaneous & Average Power
1 ECE 3336 Introduction to Circuits & Electronics Set #16 Transformers Fall 2011, TUE&TH 4-5:30 pm Dr. Wanda Wosik.
Chapter 7 AC Power Analysis
Circuits II EE221 Unit 11 Instructor: Kevin D. Donohue Complex Power, Power Conservation, Power Factor Correction, and Applications.
© The McGraw-Hill Companies, Inc McGraw-Hill 1 PRINCIPLES AND APPLICATIONS OF ELECTRICAL ENGINEERING THIRD EDITION G I O R G I O R I Z Z O N I 7.
Alexander-Sadiku Fundamentals of Electric Circuits
POLYPHASE CIRCUITS LEARNING GOALS Three Phase Circuits Advantages of polyphase circuits Three Phase Connections Basic configurations for three phase circuits.
Chapter 11 AC Power Analysis
Power System Fundamentals EE-317 Lecture 3 06 October 2010.
1 Figure 7.1, 7.2 Chapter 7: AC PowerCurrent and voltage waveforms for illustration of AC power.
Chapter 13 Magnetically Coupled Circuits
Copyright © 2009 Pearson Education, Inc. Chapter 33 Inductance, Electromagnetic Oscillations, and AC Circuits Part II.
1 ELECTRICAL TECHNOLOGY ET 201  Define series impedances and analyze series AC circuits using circuit techniques.
1 ELECTRICAL TECHNOLOGY EET 103/4  Define and explain sine wave, frequency, amplitude, phase angle, complex number  Define, analyze and calculate impedance,
RC Circuits Chapter 10 Thomas L. Floyd David M. Buchla DC/AC Fundamentals: A Systems Approach.
1 ECE 3336 Introduction to Circuits & Electronics Set #15 Complex Power Fall 2011, TUE&TH 4-5:30 pm Dr. Wanda Wosik.
Chapter 10 Sinusoidal Steady- State Power Calculations
EKT103 ELECTRICAL ENGINEERING
1  Explain and calculate average power, apparent power, reactive power  Calculate the total P, Q and S and sketch the power triangle. ELECTRICAL TECHNOLOGY.
Chapter 31 Lecture 33: Alternating Current Circuits: II HW 11 (problems): 30.58, 30.65, 30.76, 31.12, 31.26, 31.46, 31.56, Due Friday, Dec 11. Final.
Chapter 8 Alternating Current Circuits. AC Circuit An AC circuit consists of a combination of circuit elements and an AC generator or source An AC circuit.
AC POWER ANALYSIS. 2 Content Average Power Maximum Average Power Transfer Complex Power Power Factor Correction.
EKT103 ELECTRICAL ENGINEERING
POLYPHASE CIRCUITS LEARNING GOALS Three Phase Circuits
CHAPTER 2: DC Circuit Analysis and AC Circuit Analysis Motivation Sinusoids’ features Phasors Phasor relationships for circuit elements Impedance and admittance.
FUNDAMENTAL OF ELECTRICAL POWER SYSTEMS (EE 270)
Chapter 13 The Basic Elements and Phasors. Objectives Be able to add and subtract sinusoidal voltages or currents Use phasor format to add and subtract.
Chapter 10 RC Circuits.
RC Circuits (sine wave)
Power in AC Circuits Introduction Power in Resistive Components
Chapter 11 AC Power Analysis
Lesson 21: AC Power and Power Triangle
Chapter 11 AC Power Analysis
Sinusoidal Excitation of Circuits
Power in AC Circuits Introduction Power in Resistive Components
ELL100: INTRODUCTION TO ELECTRICAL ENGG.
The instantaneous power
E E 2415 Lecture 9 Phasor Circuit Analysis, Effective Value and Complex Power: Watts, VAR’s and Volt-Amperes.
Presentation transcript:

Chapter 7 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

Learning Objectives 1. Understand the meaning of instantaneous and average power, master AC power notation, and compute average power for AC circuits. Compute the power factor of a complex load. 2. Learn complex power notation; computer apparent, real, and reactive power for complex loads. Draw the power triangle, and compute the capacitor size required to perform power factor correction on a load. 3. Analyze the ideal transformer; compute primary and secondary currents and voltages and turns ratios. Calculate reflected sources and impedances across ideal transformers. Understand maximum power transfer. 4. Learn three-phase AC power notation; compute load currents and voltages for balanced wye and delta loads. 5. Understand the basic principles of residential electrical wiring and of electrical safety.

The most general expressions for the voltage and current delivered to an arbitrary load are as follows: Where V and I are the peak amplitudes of the sinusoidal voltage and current, respectively, and θy and θI are their phase angles.

Since the instantaneous power dissipated by a circuit element is given by the product of the instantaneous voltage and current, it is possible to obtain a general expression for the power dissipated by an AC circuit element:

Average power

Impedance triangle

Throughout the remainder of this chapter, the symbols and will denote the rms value of a voltage or a current, and the symbols and will denote rms phasor voltages and currents.

The term cos(θ) is referred to as the power factor (pf) The term cos(θ) is referred to as the power factor (pf). The power factor is equal to 0 for a purely inductive or capacitive load and equal to 1 for a purely resistive load.

1. An average component, which is constant; this is called the average power and is denoted by the symbol where R = Re Z. 2. A time-varying (sinusoidal) component with zero average value that is contributed by the power fluctuations in the resistive component of the load and is denoted by

3. A time-varying (sinusoidal) component with zero average value, due to the power fluctuation in the reactive component of the load and denoted by px(t): where X = Im Z and Q is called the reactive power. Note that since reactive elements can only store energy and not dissipate it, there is no net average power absorbed by X.

The units of Q are volt amperes reactive, or VAR The units of Q are volt amperes reactive, or VAR. Q represents exchange of energy between the source and the reactive part of the load; no net power is gained or lost in the process.

The magnitude of |S|, is measured in units of volt amperes (VA) and is called the apparent power.

COMPLEX POWER CALCULATION FOR A SINGLE LOAD FOCUS ON METHODOLOGY COMPLEX POWER CALCULATION FOR A SINGLE LOAD 1. Compute the load voltage and current in rms phasor form, using the AC circuit analysis methods presented in Chapter 4 and converting peak amplitude to rms values. 2. Compute the complex power and set 3. Draw the power triangle, as shown in Figure 7.11. 4. If Q is negative, the load is capacitive; if positive, the load is reactive. 5. Compute the apparent power |S| in volt amperes.

Complex Power Calculations Insert Example 7.4

A power factor close to unity signifies an efficient transfer of energy from the AC source to the load. If the load has an inductive reactance, then θ is positive and the current lags (or follows) the voltage. Thus, when θ and Q are positive, the corresponding power factor is termed lagging. Conversely, a capacitive load will have a negative Q and hence a negative θ. This corresponds to a leading power factor, meaning that the load current leads the load voltage.

FOCUS ON METHODOLOGY COMPLEX POWER CALCULATION FOR POWER FACTOR CORRECTION 1. Compute the load voltage and current in rms phasor form, using the AC circuit analysis methods presented in Chapter 4 and converting peak amplitude to rms values. 2. Compute the complex power and set 3. Draw the power triangle, for example, as shown in Figure 7.17. 4. Compute the power factor of the load pf = cos(θ). 5. If the reactive power of the original load is positive (inductive load), then the power factor can be brought to unity by connecting a parallel capacitor across the load, such that QC = −1/ωC = −Q, where Q is the reactance of the inductive load.

Power Factor Correction

Transformers The Ideal Tranformer A transformer is a device that couples two AC circuits magnetically rather than through any direct conductive connection and permits a “transformation” of the voltage and current between one circuit and the other. The Ideal Tranformer The ideal transformer consists of two coils that are coupled to each other by some magnetic medium. There is no electrical connection between the coils. The coil on the input side is termed the primary and that on the output side the secondary. The primary coil is wound so that it has n1 turns, while the secondary has n2 turns. We define the turns ratio N as

Ideal transformer

An ideal transformer multiplies a sinusoidal input voltage by a factor of N and divides a sinusoidal input current by a factor of N.

It should be apparent that expressing the circuit in phasor form does not alter the basic properties of the ideal transformer, as illustrated by the following equations:

Impedance reflection across a transformer

When the load impedance is equal to the complex conjugate of the source impedance, the load and source impedances are matched and maximum power is transferred to the load.

Maximum Power Transfer Through a Transformer

Balanced three-phase AC circuit Most of the AC power used today is generated and distributed as three-phase power, by means of an arrangement in which three sinusoidal voltages are generated out of phase with one another. Balanced three-phase AC circuit

Positive, or abc, sequence for balanced three-phase voltages The line voltages may be computed relative to the phase voltages as follows:

Balanced three-phase AC circuit (redrawn) The total power delivered to the balanced load by the three-phase generator is constant.

Delta-connected generators