Power Factor: What Is It and Estimating Its Cost Presented by:Marc Tye, P.E. 2004 APPA Business & Financial Conference September 21, 2004.

Slides:



Advertisements
Similar presentations
“Power Factor” In Transmission System
Advertisements

ALPHA POWER SOLUTIONS Presented by Eric Solot An Introduction to Power Factor Correction.
POWER FACTOR IN ELECTRICAL ENERGY MANAGEMENT
Amendment 3/5 Workshop.
COST EFFECTIVE SOLUTION TO REDUCING YOUR ENERGY BILL’S POWER MASTER Power Master, LLC, 2040 E. Ridge Rd, Rochester, NY, 14622,
DTE/ESD Energy Conference and Exhibition Energy Efficiency Implementation Case Study Power Factor Correction Case Study -Power.
Electrical Systems.  This section discusses: –How utilities charge for electricity –How to calculate the avoided cost of electricity –How to use utility.
Energy Savings Through Power Factor Correction
1 Northeast Public Power Association Electric Utility Basics Electric Rates and Cost of Service Studies.
Sinusoidal Steady-State Power Calculations
Announcements Be reading Chapters 1 and 2 from the book
Power Factor Correction Most domestic loads (such as washing machines, air conditioners, and refrigerator) and industrial loads (such as induction motors)
Power Factor and Power Factor Correction
Lesson 27 Power Factor Correction
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
LOGO LINEAR CIRCUIT ANALYSISSAJID HUSSAIN QAZI MEHRAN U.E.T, KHAIRPUR CAMPUS A.C POWERS AND POWER FACTOR.
Example 10.6 Calculating Power in Parallel Loads
1 Training Session on Energy Equipment Electricity Presentation from the “Energy Efficiency Guide for Industry in Asia” ©
Plant Utility System (TKK-2210)
Utility Analysis. Baseline Electricity Analysis  Understanding and documenting current energy use is called developing a baseline. Developing a baseline:
Circuits II EE221 Unit 4 Instructor: Kevin D. Donohue Complex Power, Power Conservation, Power Factor Correction, and Applications.
1 Training Session on Energy Equipment Electrical Systems Presentation to Energy Efficiency Guide for Industry in Asia Chapter 1 © UNEP GERIAP Electrical.
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
TVA Generates Power and sends it down Transmission Lines to Newport Utilities Distribution Substations TVA Newport Utilities Substations Distributes the.
Technical Presentation on the new Power Saving Unit (PSU) Introduced By View Power.
Utility Savings Bill McGroarty Suburban Electric Supply Co.
Chapter 11 AC Power Analysis
POWER FACTOR CORRECTION
A Tariff for Local Reactive Power Supply IEEE PES T&D Conference, April 24, 2008 Christopher Tufon, Pacific Gas and Electric Co. Alan Isemonger, California.
Power in AC Circuits ELEC 308 Elements of Electrical Engineering
Tubas ELECTRICAL NETWORK STUDY Prepared by : Omar Abu-Omar Ahmad Nerat Sameed banifadel PRESENTATION TO: Dr.MAHER KHAMASH.
Welcome New York Independent System Operator. (Pre-NYISO) Regulated Market Physical contracts Regulated industry Cost Based System Two Party Deals Bundled.
AC POWER ANALYSIS Instantaneous & Average Power
Power / Energy Management. Background  USA has 6% of worlds population - Uses 33% of energy consumed  In 1946 we used 30*10 15 BTU  In 1980 we used.
Technical Conference on Net Metering Load Research Study November 5, 2014.
Chapter 7 AC Power Analysis
Circuits II EE221 Unit 11 Instructor: Kevin D. Donohue Complex Power, Power Conservation, Power Factor Correction, and Applications.
Circuit Master Circuit Master™ uses three PROVEN technologies* – Capacitor (reduces DEMAND) – Harmonic Filter (harmful frequencies) – Surge Protection.
Capacitor Training Duck River Electric Membership Corp. Doug Simpson.
Management and Organisation of Electricity Use Electrical System Optimisation Belgrade November 2003.
AN- NAJAH NATIONAL UNIVERSITY OPTIMUM DESIGN AND PERFORMANCE FOR NABLUS NETWORK Submitted To : Dr. Maher Khammash Prepared By : Haitham Sharaf Ahmad Odeh.
Chapter 17 Power in AC Circuits.
1 11/17/2015 Power Quality Correction. 2 11/17/2015 Power Quality Correction.
ANALYSIS OF THE OPERATING CONDITION OF Qalqilia ELECTRICAL NETWORK
Chapter #6 Power Factor Improvement Rashid Gulzar (Bsee )
Three Phase Motors Maths
Talha Mehmood Chapter # 5 TARIFF. Introduction The electrical energy produced by a power station is delivered to a large number of consumers. The supply.
AC POWER ANALYSIS. 2 Content Average Power Maximum Average Power Transfer Complex Power Power Factor Correction.
Electricity pricing Tariffs.
REACTIVE POWER COMPENSATION
Presented by. What is Power Factor? Power Factor is the percentage of current delivered from the utility that is needed to perform the actual work. For.
FUNDAMENTAL OF ELECTRICAL POWER SYSTEMS (EE 270)
Established in Started by visionary Engineers & Entrepreneurs with Proven Power Electronics background. Committed to energy conservation. Made a.
Power Factor Correction
By Fluke India.
1 Chapter 3 AC Power Analysis. 2 AC Power Analysis Chapter 3 3.1Instantaneous and Average Power 3.2Maximum Average Power Transfer 3.3Effective or RMS.
Lesson 3: Ac Power in Single Phase Circuits
Power Generation and Distribution
Power Factor Correction The Definitive power solution
Power Factor Correction The Definitive power solution
Chapter 11 AC Power Analysis
EFFECTIVE OR RMS VALUES
Introduction To Reactive Power
City of Lebanon, Missouri Electric Department
Why does power factor matter Make-up of distribution capacitor banks
Tubas ELECTRICAL NETWORK STUDY
Sr. Lecturer in Electrical Engg. Govt. Polytechnic,Manesar
ELL100: INTRODUCTION TO ELECTRICAL ENGG.
Exercise Session 3 Power systems.
Energy Management PPKSE 06/07 SAA.
Presentation transcript:

Power Factor: What Is It and Estimating Its Cost Presented by:Marc Tye, P.E APPA Business & Financial Conference September 21, 2004

What Is Power Factor Reactive Power (kVAr) Apparent Power (kVA) Real Power (kW) Power Factor can be either lagging (inductive) or leading (capacitive).

Why Utilities Charge For Poor Power Factor?  Low P.F. results in increased system variable costs to produce real power  Losses  Fuel Costs  Low P.F. results in increased system fixed costs to transmit/distribute real power  Generators  Conductors  Transformers  Capacitors  Reactive power must be produced or absorbed to maintain transmission voltages within acceptable limits.

Santee Cooper Uses Various Methods to Charge for Reactive Power Generation and Transmission Customers  Reactive cost is included in customers’ average embedded rates.  Power factor penalty is charged to customers not maintaining a 90% P.F. Transmission Only Customers  Reactive supply and voltage control is a required ancillary service.  Charge based upon the amount of power the customer is wheeling across the transmission system.

Santee Cooper’s Industrial Power Factor Requirement “The Customer’s Excess Reactive Demand for each Billing Month shall be the amount, if any, by which the Customer’s maximum 30-minute integrated reactive demand, in kilovars (kVAr), during such Billing Month exceeds 48.5% of the Customer’s Measured Demand, in kilowatts (kW), for such Billing Month.”  Equivalent to a minimum of 90% power factor by the Customer  Customer can correct to 90% power factor or company will charge for excess reactive demand L-96 Excess Reactive Demand Charge:

Industrial Reactive Demand Charge Based on Average Cost of Capacitor Bank 1.Cost of 69kV, 12,000 kVAr Bank Annual Costs: 2.Debt Service 3.O&M 4.Subtotal 5.CIFR 6.Total 7.Annual Cost per kVAr 8.Monthly Cost per kVAr 9.Adjusted for Inflation 10.Adjusted for Losses 11.Rounded $255,678 $ 49,257 $ 3,000 $ 52,257 $ 4,855 $ 57,112 $ 4.76 $ 0.40 $ 0.43 $ $ 0.44 (7.5% interest, 7 years) (8.5%) (Line 6 / 12,000) (Line 7 / 12) (2 4%) (3.65%) / kVAR - mo

Power Factor Example 7,000 kVAr 13,892 kVA 12,000 kW Cos = 12,000 13,892 = 86.4%

Example of Excess Reactive Demand Charge 1.Measured Demand (kW) 2.Measured Reactive Demand (kVAr) 3.Power Factor 4.Allowed Reactive Demand w/o Charge (kVAr) 5.Excess Reactive Demand (kVAr) 6.Excess Reactive Demand Charge 12,000 7, % 5,820 1,180 $519.20

Santee Cooper Open Access Transmission Tariff  Reactive supply and voltage control from generation sources service is a required ancillary service.  Ancillary service used to maintain transmission voltage  Rate is based on allocated portion of the cost of exciter and generator for each unit that produces kVAr’s.  Rate also includes allocated portion of the power consumed by the exciter.

Reactive Power Cost Summary Generator / Exciter Costs 1.Generator and exciter fixed costs (VAr Related) 2.Production fixed charge rate 3.Generator and exciter costs charged to VArs 4.Fixed O&M charged to VArs 5.Total $6,864, % $ 827,899 $ 224,589 $1,052,488 Real Power Output Charged to Exciter 6.Exciter power consumption 7.Exciter energy consumption 8.Total 9.Total reactive support cost 10.Single system coincident peak (kW) 11.Monthly point to point rate ($ / kW.mo) $ 116,361 $ 158,780 $ 275,141 $1,327,629 3,037,000 $

Example of Reactive Supply and Voltage Control Charge 1.Measured Point to Point Reservation (MW) 2.Monthly Reactive Supply and Voltage Control Charge (kW) 3.Total Monthly Reactive Supply and Voltage Control Charge 100 $ $3,640