Chp-3-Strength Analysis of Beams According to ACI Code

Slides:



Advertisements
Similar presentations
COMPRESSION FIELD THEORY FOR SHEAR STRENGTH IN CONCRETE
Advertisements

Unless otherwise noted, the content of this course material is licensed under a Creative Commons Attribution 3.0 License.
Chp12- Footings.
Design of Concrete Structure I
Lecture 9 - Flexure June 20, 2003 CVEN 444.
Design of Concrete Structure I Eng. Tamer Eshtawi First Semester 2008 Eng. Tamer Eshtawi First Semester 2008.
Reinforced Concrete Design
Unless otherwise noted, the content of this course material is licensed under a Creative Commons Attribution 3.0 License.
Unless otherwise noted, the content of this course material is licensed under a Creative Commons Attribution 3.0 License.
Reinforced Concrete Flexural Members
Design of Concrete Structure I
Shear and Diagonal Tension
Lecture 15- Bar Development
SHEAR IN BEAMS. SHEAR IN BEAMS Example (4.1): A rectangular beam has the dimensions shown in Figure 4.12.a and is loaded with a 40 ton concentrated.
ONE-WAY SLAB. ONE-WAY SLAB Introduction A slab is structural element whose thickness is small compared to its own length and width. Slabs are usually.
Chp.12 Cont. – Examples to design Footings
Section 3 design of post-tensioned components for flexure Developed by the pTI EDC-130 Education Committee lead author: trey Hamilton, University of.
Torsion in Girders A2 A3 M u = w u l n 2 /24 M u = w u l n 2 /10M u = w u l n 2 /11 B2 B3 The beams framing into girder A2-A3 transfer a moment of w u.
CEE Capstone II Structural Engineering
Flexural Component Design
Basic Design Principles For Reinforced Concrete Beam
Lecture Goals Doubly Reinforced beams T Beams and L Beams.
Unless otherwise noted, the content of this course material is licensed under a Creative Commons Attribution 3.0 License.
EXAMPLE 9.2 – Part IV PCI Bridge Design Manual
Weekly Course Distribution
T Beams.
Footings.
EXAMPLE 9.2– Part VI PCI Bridge Design Manual
COLUMNS. COLUMNS Introduction According to ACI Code 2.1, a structural element with a ratio of height-to least lateral dimension exceeding three used.
Introduction to Columns
Composite Beams and Columns
Lecture on CE 4014 Design of Concrete Structures
DESIGN FOR TORSION Reinforced Concrete Structures
SHEAR IN BEAMS. SHEAR IN BEAMS Introduction Loads applied to beams produce bending moments, shearing forces, as shown, and in some cases torques. Beams.
Lecture 21 – Splices and Shear
University of Palestine
Reinforced Concrete Design
Compression Component Design
Chapter 4 - Flexure. Lecture Goals Structures Basic Concepts Rectangular Beams.
Lecture 2 - Fundamentals. Lecture Goals Design Process Limit states Design Philosophy Loading.
By Dr. Attaullah Shah Swedish College of Engineering and Technology Wah Cantt. Reinforced Concrete Design-4 Design of doubly reinforced beams.
1.
FOOTINGS. FOOTINGS Introduction Footings are structural elements that transmit column or wall loads to the underlying soil below the structure. Footings.
CTC 422 Design of Steel Structures
1 Design of Concrete Structure I Dr. Ali Tayeh First Semester 2009 Dr. Ali Tayeh First Semester 2009.
Unless otherwise noted, the content of this course material is licensed under a Creative Commons Attribution 3.0 License.
By Dr. Attaullah Shah Swedish College of Engineering and Technology Wah Cantt. Reinforced Concrete Design-3 Flexural Design of Beams.
6- Calculation of shear stress at composite interface: A)Under service load: Strain and stress distributions across composite beam cross- section, under.
Chapter 4 - Flexure King Saud University University Civil Engineering Department Reinforced Concrete Design Prof. Dr. Mohammad Jamal Al-Shannag.
UNIT-2.
By Dr. Attaullah Shah Swedish College of Engineering and Technology Wah Cantt. Reinforced Concrete Design-6 Shear Design of Beams.
Principal Stresses in Beams
Lecture 5 - Flexure June 11, 2003 CVEN 444.
UNIT-IV SHEAR,TORSION AND BOND.
Reinforced Concrete Design
Behaviour of Reinforced Concrete Beams Under Bending
Reinforced Concrete Design. Compressive Strength of Concrete f cr is the average cylinder strength f’ c compressive strength for design f’ c ~2500 psi.
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg
SINGLY REINFORCED BEAM (R.C.C)
Reinforced Concrete Design-3 Flexural Design of Beams
SINGLY REINFORCED BEAM (R.C.C)
Design of Reinforced Concrete
Reinforced Concrete Design-4 Design of T beams
Reinforced Concrete Design-4 Design of T beams
Reinforced Concrete Design-6
Reinforced Concrete Design-4 Design of doubly reinforced beams
Reinforced Concrete Design-3 Flexural Design of Beams
NOTATION fps = stress in prestressing steel at service loads less decompression stress, ksi 4/7/2019 Ce 572.
Reinforced Concrete Design-4 Design of T beams
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg
Presentation transcript:

Chp-3-Strength Analysis of Beams According to ACI Code From the early 1900s until the early 1960s, nearly all reinforced concrete design in the United States was performed by the working-stress design method (also called allowable-stress design or straight-line design). [n this method, frequently referred to as WSD, the dead and live loads to be supported, called working loads or service loads, were first estimated. Then the members of the structure were proportioned so that stresses calculated by a transformed area did not exceed certain permissible or allowable values.

equivalent rectangular block

Mu is factored load, φ is strength reduction factor. Mn , is defined as the theoretical or nominal resisting moment of a section. Mu is factored load, φ is strength reduction factor.

The usable flexural strength[or ultimate moment capacity]

p. 654 for fy = 40,000 psi, and f’c = 4,000 psi

BALANCED SECTIONS, TENSION-CONTROLLED SECTTONS and COMPRESSTON-CONTROLLED OR BRITTLE SECTIONS

Please continue to read page 71 be able to interpret Figure 3 Please continue to read page 71 be able to interpret Figure 3.5 for comprehension of :

failure can occur in very lightly reinforced beams failure can occur in very lightly reinforced beams. If the ultimate resisting moment of the section is less than its cracking moment, the section will fail immediately when a crack occurs. This type of failure may occur without warning. To prevent such a possibility, the ACI (10.5.1) specifies a certain minimum amount of reinforcing that must be used at every section of flexural members where tensile reinforcing is required by analysis, whether for positive or negative moments. In the following equations, bw, represents the web width of beams.