2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and Operation Manual for detailed instructions)

Slides:



Advertisements
Similar presentations
Engineer Training XL1200 Pneumatics. Engineer Training XL1200 Pneumatics Confidential 2 Working Concept Overview: The Pneumatic System is comprised of:
Advertisements

BeginningNext SlideBack End Program AVADAL 1 of 18 SK-16 Main Pumps 4 Pumps Per Strand – Normally 2 running and 2 on standby as back-up. Motor is 60 HP.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
WIRED TYPE MULTI ZONE FANCOIL CONTROL SYSTEM MODEL : WSF- 700 SYSTEM
Morgan City Rentals Diesel Jet Pump 6 x 6 Peerless Safe Operating Practices and Procedures.
Getting Started Product Description Setting Parameters How does it work Wiring Diagram.
FoamPro 1600 Series Fully automatic Class A foam ONLY
 Description of PressurePro System  Identify system components  Display and Operational Modes  Sensor alerts  Checking of tire pressures  Manual.
Selecting A FoamPro System. 153 Class A foam concentrates –NFPA 1150 or US Forest Service Approved Class B foam concentrates –Use of a lower % foam concentrate.
4Identifying Leakage Source (Mech/ Elec) 4Mechanical Air Leak- Down 4Mechanical Air Leak- Up 4Electronic Drift- Up/ Down 4Load Cell Operation 4Understanding.
SAFETY MEETING Off Highway Trucks. Brakes There are four separate controls used for braking Service Brake Retarder Secondary Brake Parking Brake.
CAFS On-Line Orientation
Pressing Green ► button will cycle through each of four System Modes. The ▲ at the top of the display points to the active System Mode. 1.OFF – Unit will.
Fire Research Pump Boss 400 Pressure Governor
Proportioning Systems. 69 Proportioning Systems Now you know the benefits and uses of water additives, especially Class A foam. So how do we get the concentrate.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
1B-1 Fire Engine Maintenance Unit 1B – Pump Inspections and Maintenance.
KLINGE’S NMR 262 Two Independent Systems Integrated into one Unit This Requires Special Features:  Total Redundancy of Refrigeration Components  Total.
Power-Fill Operation Demonstration Power-Fill Operation Demonstration (See Installation and Operation Manual for detailed instructions)
Hydraulic Anti-Lock Braking System For Trucks, Buses and Motor Homes.
AccuMax Single Point Injection Operation (See Installation and Operation Manual for detailed instructions)
Basics of Pump Vigyan Ashram, Pabal.
CAFS On-Line Orientation
AccuMax Multi-Point Injection Mechanics
Experts in Chem-Feed and Water Treatment General Hydraulics Fluid Mechanics.
CAFS On-Line Orientation Montgomery County Fire & Rescue Service Operating the CAFS Controllers.
Hydronic Mechanical Controls
Programming instructions.. To set the time Pool pump and heat pump must be ON. Pictrue 1Picture 2Picture 3 1.Press, the hour will flash (picture 1) 2.To.
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
Muhajir Ab. Rahim School of Mechatronic Engineering
FoamPro Features & Benefits. 139 FoamPro Systems 1600 Series 2000 Series 3012 Model AccuMax Series.
Water Handling Operations
Settings & Adjustments. Settings & Adjustments.
The complete flow monitoring solution Measure – Display – Switch – Transmit.
GCS 300 System Operation Application – Level 1.
ENGINES. VEHICLE / HEAVY EQUIPMENT SAFETY INSPECTION CHECKLIST OF 296.
Section 703 Apparatus Inspection. Procedures The driver/operator should follow a systematic procedure for inspecting apparatus This ensures that all important.
Engineer Training Pneumatic System Overview. Engineer Training Confidential 2 Working Concept Overview: The Pneumatic System is comprised of:  Y Pistons.
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
Tweety Operation Manual. Refurbish History Motor 1) Cummings Diesel (V6), ) Red Line 3000 (hums at 2800) 3) Top Speed 60 MPH.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
TrueSTEAM™ Humidification Systems Module 6: User Interface.
Fire Fighting Systems Fi Fi Mains ●White System: This system has a lower output as far as volume goes. This main supplies 3x Eductor/Hydrants (500 gpm).
To complete installation on electronic models run one wash cycle then click the DIP switch setting no.4 to the on position DIP switch settings.
CUE – Make Any Pump an E-Pump
Service Section Technical Training December 2005.
Discover the Dosmatic Difference Maintaining your Dosmatic injector for years of service.
The complete flow monitoring solution Measure – Display – Switch – Transmit.
Submitted by Pradeep pataskar Roll no.11031M02034.
STEP 1 Locate the transmission cooler line connection on the vehicle. Identify the correct adapters to be used by referring to the vehicle application.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
Class A Foam 101 Marysville Division of Fire 2009.
Compressed Air Foam System
Foam Equipment & Systems Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
Cleaning Mode Startup Mode Spray Mode Maintenance Mode Standby Mode
Quick Start Guide for Flex Flow Pump
R1 Fundamentals of Refrigeration
Troubleshooting Hydraulic Pumps
TABLE OF CONTENTS A- Unit description B- Microprocessor Control box
SB Packing Automatic Downpuller Power Unit
Fuel Supply System Service
R1 Fundamentals of Refrigeration
CAFS On-Line Orientation
Digital Chart Recorder Operation
Diagnostics Analytical 920 LC Semi-Prep 940 LC
CAFS On-Line Orientation
Universal Interrupted Electronic Oil Primary R7184U Training Module
Component Overview Water Measuring System Syrup Injection System
FOAMPRO 2001 / 2002 Pump Panel. FOAMPRO 2001 / 2002 Pump Panel.
Presentation transcript:

2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and Operation Manual for detailed instructions)

2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner Check Valves Flow Meter

3 Water Tank Water Pump Flowmeter Line Strainer Foam Tank Electronic Direct Injection Proportioner Check Valves Multiple Discharges 3012 Model

4 Digital display reads “Hypro” upon initial power- up System then enters flow mode in standby –Operates as flowmeter Digital Display Operation

5 Push red “FOAM” button to arm system –“ON” light illuminates Open foam discharge –Displays solution volume –“ON” light blinks when foam pump runs Digital Display Operation

6 Water flow display Push “SELECT” button and total volume of water discharged is displayed –Gallons, liters, imperial gallons Digital Display Operation

7 Push “SELECT” button to enter “%” mode –Displays default injection percentage –“PA” Single tank system –“PC” Remote start/stop (“UP” or “DOWN” button will override default setting) Digital Display Operation

8 Push “SELECT” button to enter “TOTAL FOAM” –Displays total concentrate injected Dual-tank mode –Totals for each tank –Display corresponds to tank chosen by dual-tank valve

9 Digital Display Operation Enter “INJECTION PERCENTAGE” from any mode –Press either “UP” or “DOWN” button momentarily to display current percentage setting –Hold either button for two seconds to change setting accordingly

10 Operating Instructions System Reset Total Water %(Percent) Total Foam Reset these modes to 0 or % to default setting Push both the up and down buttons in desired mode

11 Size Max Accuracy Max Operating Tee Flow Range Flow Range 1-1/2x1" gpm gpm 1-1/2" gpm gpm 2" gpm gpm 2-1/2" gpm gpm 3" gpm gpm 4" gpm gpm Flowmeter No flow restrictions Wide operating range

Safety Features

13 When Lo con is Displayed –Selected foam concentrate tank is getting low –If foam concentrate is added within 2 minutes Lo con goes out –If no foam concentrate is added within 2 minutes no con is displayed When no con is Displayed –Foam concentrate pump will not run –Add foam concentrate until no con display goes out then push Red Foam button to start the foam pump Low Foam Display

14 Exceeding Foam Injection Rate Hi Flo display –Occurs when the water flow and selected foam concentrate injection percentage exceeds the foam pump capabilities –Informs pump operator when this situation occurs –Lower the foam concentrate injection percentage or water flow to stop the flashing Hi Flo display

15 Motor Driver Module controls pump motor Totally enclosed environmentally sealed Incorporates system circuit breaker

16 Digital Display Operation Simulated flow –While in “FLOW” mode, push both lower buttons simultaneously –Three bars on left indicate manual mode –Pushing red “FOAM” button will turn foam pump on/off –Pump injects to simulated flow default setting

17 System Air Purge Enter “SIMULATED FLOW” Turn injection valve from “INJECT” to “CAL/FLUSH” Push red “FOAM” button on display to start foam pump

18 System Air Purge (cont.) Run until concentrate flows steady out of dump line Push red “FOAM” button to stop pump Turn injection valve to “INJECT” Exit “SIMULATED FLOW”

System Maintenance

Series Foam Pump Totally enclosed environmentally sealed motor Housing incorporates speed sensor Positive displacement plunger pump –Components made of corrosion resistant materials –Max operating pressure is 400 psi

Foam Pump Hydraulic motor Housing incorporates speed sensor Positive displacement plunger pump –Components made of corrosion resistant materials –Max operating pressure is 400 psi

22 System Maintenance Clean strainer(s) regularly –Purge pump to remove air pockets afterwards Check oil level –Dip stick reading or –Sight glass

Concentrate Management Systems

24 Foam Tank A Foam Tank B Manual CMS

25 Foam Tank B Electronic CMS Foam Tank A

26 Digital Display Operation Dual-tank function –Dual-tank valve in “A” –Displays “PA” and default setting –Dual-tank valve in “B” –Displays “Pb” and default setting Default settings from 0.1 to 6.0%

27 Dual Foam Concentrate Tank (CMS)

28 Dual-Tank Flush System does not require flushing after Class A foam use –Turn off and flush hose Flush after using Class B foam –Flow water and engage foam system –Turn manual valve to “FLUSH” or electric valve to “OFF” (“Off” position is a constant flush)

MultiFlo Interface

30 MultiFlo Interface Std. Controller or AFC MultiFlo Display Control Cable Flowmeter Cable Flowmeter