Long/Short Pulse Laser Platform

Slides:



Advertisements
Similar presentations
Phototherapy – BBL BroadBand Light™
Advertisements

Introduction to Aesthetic Laser Concepts
MedArt ® 450 CO 2 laser. Table of contents CO 2 CO 2 vs alternatives Considerations in CO 2 treatments Summary The MedArt ® 450 The MedArt ® 456 Recommended.
Say Goodbye to Thread Veins forever
The 2nd generation of Fractional Tx. With CIS-F1
LASER Applications for Skin Rejuvenation
GOLD STANDARD OF RADIOFREQUENCY
GentleLASE, GentleYAG & GentleMAX
Venous Insufficiency: Nuts and Bolts
LASER. ACTION ?? Based on the theory of Selective Photothermolysis: The target chromophore is melanin The target chromophore is melanin ◦Present in the.
4 Joseph Lepselter, Director Clinical Department March 1, 2012 DRAFT CONCEPT.
What if you took 10 times of the power that lights up Paris at night……
بسم الله الرحمن الرحيم Sudan University Of Science & Technology College Of Post Graduate Studies Utilization Of Carbon Dioxide Laser ( 10600nm) In The.
1.  Achrochordons or skin tags are common benign skin over growth usually begin in 2nd decade and peak by the 6th decade of life. There is familial disposition.
By: DR Neda Adibi Dermatologist. The growth of unwanted and terminal hairs in androgen dependent area in the females called hirsutism The etiology is.
Business Opportunity for Beauty Salons
Skin Tightening Skin Tightening Technique. The purpose of a Skin Tightening Treatment With age, the collagen that provides volume and structure to our.
ight mplification of ight mplification of ight mplification of timulated ight mplification of timulated.
Low-level laser therapy for treating myofascial pain syndromes of vertebral genesis mechanisms of therapeutic effects of low-level laser irradiation types.
LASER APPLICATIONS TO MEDICINE AND Prof. Dr. Moustafa. M. Mohamed Vice Dean Faculty of Allied Medical Science Pharos University Alexandria Dr. Yasser khedr.
Laser Safety Calculations
Excel HR ™ 21 st Century Hair Removal. Nd:YAG 1064 nm Skin Types I-VI Safest wavelength for darker skin and tanned patients Effective on dark, coarse.
By B. Nelson. Definition of IR radiation Radiation: the process of emitting energy in waves from a source Portion of the electromagnetic spectrum with.
Intense Pulse Light (IPL) Photo Facial
IPL ™ and Laser For all your skin care needs. The most advance light-based technologies for all your skin care needs –Introduced in 1995 –Tens of thousands.
Quanta “The Story…Who we are, where we come from” Quanta Aesthetic Lasers USA, LLC is in partnership with Quanta System S.p.A. (Italy) to bring this incredible.
Multi-Application Pulsed Light System
Rex Moulton-Barrett, MD Plastic & Reconstructive Surgery San Leandro Surgery Center.
Laser Hair Removal – ClearScan ™ © 2008 Sciton, Inc. All rights reserved.1 High Speed Laser Hair Removal – safe treatment for all skin types.
Contour TM 2940nm Er:YAG ThermaScan TM 1319nm Nd:YAG ClearScan TM 1064nm Nd:YAG BBL TM nm Intense Pulsed Light Personalized For Your.
PLASMA LIGHT TECHNOLOGY FDA and Medical CE certified.
Laser Resurfacing A truly effective procedure for eliminating difficult facial wrinkles.
Accolade QS Alexandrite 755 nm
Copyright 2008 CoolTouch Inc. CoolTouch Product Presentation.
بسم الله الرحمن الرحیم مهرداد کفاشی The application of laser in medical.
بسم الله الرحمن الرحيم Sudan University of Science and Technology College of Postgraduate Studies Evaluation of the Efficacy of Carbon Dioxide Laser in.
Click to edit Master title style Click to edit Master text styles –Second level Third level –Fourth level »Fifth level GentleYAG.
A review in the science and experience of using an Optical and Conductive Radiofrequency System Your Speaker: Epilation And Photo-rejuvenation With The.
Click to edit Master title style Click to edit Master text styles –Second level Third level –Fourth level »Fifth level GentleLASE.
Quanta “The Story…Who we are, where we come from” Quanta Aesthetic Lasers USA, LLC is in partnership with Quanta System S.p.A. (Italy) to bring this incredible.
Advanced Technology Laser Co., Ltd. A leading manufacturer of light based devices for medical and cosmetic applications.
IPL Intense Pulsed Light System by Steinbeis Transfercentre Biomedical Engineering, Donaueschingen, Germany Director: Prof. Dr. Bernhard Vondenbusch.
Affirm TM Anti- Aging Workstation Wrinkles Facial Rejuvenation Surgical Scars Acne Scars Stretch Marks Skin Tightening.
Aurora DSR ELOSTM Technology and key features
Low-Power Lasers Jennifer L. Doherty-Restrepo, MS, ATC, LAT Entry-Level Master Athletic Training Education Program PET 4995: Therapeutic Modalities.
© Copyright Energist Ltd. 2007
Dr. Alireza Vaez Shooshtari
Fractional Ablation Course V Ver 1.0
2007. No absorption into melanin and hemoglobin No absorption into melanin and hemoglobin Secondary heating from water and protein Secondary heating from.
Reporter: 曾 千芳 Retinal Light Damage Mechanism 1. 大綱 Introduction of light hazard to eyes Retinal light damage  Background  Mechanisms of light damage.
Microwave Diathermy ELECTROTHERAPY
Independent Skin Laser Clinic at the Royal Free Hospital Mark Griffiths Consultant Dermatologist, Royal Free Hospital Partner, Private Skin Laser Clinic.
Journal review 아름다운예의원 오영상 M.D.
Faculty of Mathematics and Physics Deptartment of Physics Modelling and measurements of laser-skin thermal interaction ADVISER: prof. dr. Martin Čopič.
Evolve™ in ENT Surgery.
Peter Psillos & Amanda Martyniuk
Intense pulsed light in dermatology
Pediatric vascular anomalies
Photofacial Treatment in Delhi
Hair removal system for most skin type and hair type and collagen remodeling. REV
Hair Removal Solution Cutera’s multiple wavelength hair removal solution includes Alexandrite, Diode and Nd:YAG treatment modes making it the most versatile.
Where You can Go For Get Infini Acne Scars Removal.
Laser Treatment in Pigmented lesion and Tatoo
A Comparative Study of Photoacoustic and Reflectance Methods for Determination of Epidermal Melanin Content  John A. Viator, Jason Komadina, Lars O. Svaasand,
The role of the Lumina intense pulsed light system in the treatment of port wine stains— a case controlled study  N. Reynolds, J. Exley, S. Hills, S. Falder,
Plexr 1 συνεδρία
MedArt SmartSculpt™ Diode Laser.  TECHNICAL SPECIFICATIONS Diode Laser MedArt® 725, 25W, 980nm MedArt® 720, 15W, 980nm Laser Type: Continuous Wave Diode.
Presentation transcript:

Long/Short Pulse Laser Platform Our Solutions Long/Short Pulse Laser Platform Alexandrite 755 nm Long Pulse, up to 16 mm spot size and 2Hz of repetition rate Nd:YAG frequency doubled 532 nm Long Pulse, up to 4 mm spot size and 1Hz of repetition rate Nd:YAG 1064 nm Long Pulse, up to 12 mm spot size and 2Hz of repetition rate Nd:YAG 1064 nm Short Pulse, Up to 8 mm spot size and 7Hz of repetition rate Nd:YAG 1320 nm Long Pulse, Up to 8 mm spot size and 5 Hz of repetition rate IPL source with cut-off filters at 400, 550, 570, 590, 625, 650 nm. Fluence up to 35J/cm2 and 0.5 Hz of repetition rate Combined System, top performances, best return of investment

Vascular lesions removal Pigmented lesions removal Indications Hair Removal Vascular lesions removal Pigmented lesions removal Benign skin solid lesions Scar revision Skin sun damage

SELECTIVE PHOTOTHERMOLYSIS Indications SELECTIVE PHOTOTHERMOLYSIS (RR Anderson, JA Parrish, 1983)

Wavelength Fluence Pulse Width: ≤ TRT Selective Photothermolysis Selective aggression of the target without damage of adjacent tissues Parameters: Wavelength Fluence Pulse Width: ≤ TRT

Selective Photothermolysis Absorption The green 532 nm and the infrared 1064 nm lights are absorbed by the hemoglobin which is the targeted chromophore when treating dermal blood vessels. 532 and 1064 nm are optimal wavelengths for treating superficial micro vessels. 755 nm for hair removal up to Skin Type IV, 1064 nm also for darker skin 1320 nm, due to optimal water absorption is ideal for dermal remodeling The epidermal melanin absorption has to been taken into consideration to avoid side effects.

Approx. wavelenghts penetration in the skin Selective Photothermolysis Approx. wavelenghts penetration in the skin Penetration Longer wavelengths as preferable for deeper or larger vessels, because of their greater penetration into tissue and because The relative low melanin absorption may allow more safe heating of the full thickness of the vessel with less risks of epidermal ipo-pigmentation. For small teleangiectasia - such as those occurring commonly on the face and for PWS, lasers emitting wavelengths at or near 532nm are highly suitable, For leg veins treatments the 1064 nm wavelength of is preferable.

Thermal relaxation time for vessels of various diameters Selective Photothermolysis Laser pulse duration – TRT of targets Exposure times for blood vessels should be shorter than their thermal relaxation times Complete heating is achieved without risks of thermal damage of the surrounding tissues (Selective Photothermolysis). Exposure times range from 1 to 10 milliseconds for port wine stains and about 5 to 70 milliseconds for telangiectasia. The power output of the laser must be high enough to permit adequate energy density for vessel coagulation within this time (Energy = Power x Time). Thermal relaxation time for vessels of various diameters Diameter (µm) 30 50 70 100 150 200 250 300 350 400 TRT (ms) 0.4 1.0 2.0 4.2 9.4 16.7 26.0 37.5 51.0 66.7

“milliseconds laser” effect on blood vessels 700 800

Adjustable pulse duration spares normal capillaries, avoiding purpura. “milliseconds laser” effect on blood vessels Adjustable pulse duration spares normal capillaries, avoiding purpura. Purpura after pulsed dye laser Tx

Some Clinical Results

Facial telangiectasia SYSTEM: LASER 532 nm SKIN TYPE 2 AREA: FACE EV. FLUENCE: 23 J/Cm2 FREQUENCY: 2 Hz SESSIONS: 3 FOLLOW UP: 2 months

Facial telangiectasia SYSTEM: 532 nm LASER SKIN TYPE 2 AREA: FACE EV. FLUENCE: 14 J/Cm2 FREQUENCY: 1 Hz SESSIONS: 2 FOLLOW UP: 6 months

Spider angioma SYSTEM: 532 nm Laser SKIN TYPE 3 AREA: FACE SPOT SIZE: 2 mm EV. FLUENCE: 23 J/Cm2 FREQUENCY: 1 Hz SESSIONS: 2 FOLLOW UP: 6 months

Spider angioma SYSTEM: Long Pulse 532 nm SKIN TYPE 3 AREA: Lt upper lid EV. FLUENCE: 16 J/Cm2 FREQUENCY: 1 Hz SESSIONS: 1 FOLLOW UP: 4 Weeks

Spider angioma SYSTEM: 532 nm LASER SKIN TYPE 2 AREA: Nose EV. FLUENCE: 15 J/Cm2 FREQUENCY: 2 Hz SESSIONS: 2 FOLLOW UP: 2 months

Angioma - PWS SYSTEM: Long Pulse 532 nm SKIN TYPE 3 AREA: BACK SPOT SIZE: 2 mm EV. FLUENCE: 13 J/Cm2 @ 532 nm FREQUENCY: 1 Hz SESSIONS: 1 (test) FOLLOW UP: 3 weeks

Angioma - PWS SYSTEM: Long Pulse 532 nm SKIN TYPE 5 AREA: cheek and neck SPOT SIZE: 4 mm EV. FLUENCE: 13 J/Cm2 @ 532 nm FREQUENCY: 1 Hz SESSIONS: 5 FOLLOW UP: 3 months

Hemangioma SYSTEM: Nd:YAG LASER 1064 nm SKIN TYPE 2 AREA: cheek and neck SPOT SIZE: 6 mm EV. FLUENCE: 40 J/Cm2 @ 1064 nm (test) FREQUENCY: 1 Hz SESSIONS: 1 FOLLOW UP: 1 month

Leg telangiectasia SYSTEM: 1064 nm LASER SKIN TYPE 3 EV. FLUENCE: 140 J/Cm2 @ 1064 nm FREQUENCY: 1 Hz SESSIONS: 3 FOLLOW UP: 6 months

Leg telangiectasia SYSTEM: Light C 532 and 1064 nm LASER SKIN TYPE 2 SPOT SIZE: 4 mm EV. FLUENCE: 130 J/Cm2 @ 1064 nm FREQUENCY: 1 Hz SESSIONS: 2 FOLLOW UP: 6 months

Scars SYSTEM: LASER 532 nm SKIN TYPE: 4 AREA: FACE EV. FLUENCE: 10 J/Cm2 FREQUENCY: 1 Hz SESSIONS: 3 FOLLOW UP: 4 months

Keratosis SYSTEM: 532 nm Laser SKIN TYPE 3 EV. FLUENCE: 40 J/Cm2 FREQUENCY: 1 Hz SESSIONS: 1 FOLLOW UP: 6 Weeks

Epidermal nevus SYSTEM: 532 nm Laser SKIN TYPE 2 AREA: Neck EV. FLUENCE: 30 J/Cm2 FREQUENCY: 6 Hz SESSIONS: 1 FOLLOW UP: 8 Weeks

Hair removal SYSTEM: Long Pulse 1064 nm SKIN TYPE: 3 AREA: BIKINI LINE SPOT SIZE: 10 mm EV. FLUENCE: 45 J/Cm2 FREQUENCY: 2 Hz SESSIONS: 5 FOLLOW UP: 6 months

Hair removal SYSTEM: Long Pulse 755 nm SKIN TYPE 3 AREA: AXILLA SPOT SIZE: 12 mm EV. FLUENCE: 25 J/Cm2 FREQUENCY: 1 Hz SESSIONS: 4 FOLLOW UP: 6 months

Hair removal SYSTEM: Long Pulse 1064 nm SKIN TYPE 3 AREA: Chest SPOT SIZE: 10 mm EV. FLUENCE: 60 J/Cm2 FREQUENCY: 1.5 Hz SESSIONS: 5 FOLLOW UP: 6 months

Hair removal Female axilla, skin type II Treatment parameters with IPL Handpiece: 625-1200 nm Average Fluence: 20 J/Cm2 Pulse mode: Burst 2 Pulse width: 20 ms Pulse pause: 20 ms N. Of treatments: 4

Skin rejuvenation SYSTEM: Short Pulse 1064 nm SKIN TYPE 5 AREA: FACE SPOT SIZE: 6 mm EV. FLUENCE: 16 J/Cm2 FREQUENCY: 7 Hz SESSIONS: 4 FOLLOW UP: 6 months

Skin rejuvenation SYSTEM: Long Pulse 1320 nm SKIN TYPE 3 AREA: FACE SPOT SIZE: 6 mm EV. FLUENCE: 15 J/Cm2 FREQUENCY: 2 Hz SESSIONS: 5 FOLLOW UP: 3 months

Skin rejuvenation Female facial sundamage, skin type III Treatment parameters with IPL Handpiece: 590-1200 nm Average Fluence: 18 J/Cm2 N. Of treatments: 3

Benign pigmented lesions SYSTEM: IPL 550-950 nm filter SKIN TYPE 2 AREA: forehead SPOT SIZE: 2.5x1.3 cm EV. FLUENCE: 18 J/Cm2 SESSIONS: 2 FOLLOW UP: 6 months

Active acne SYSTEM: IPL 400-1200 nm filter SKIN TYPE 2 AREA: forehead SPOT SIZE: 4.8x1.3 cm EV. FLUENCE: 7 J/Cm2 FREQUENCY: 0.5 Hz SESSIONS: 5 FOLLOW UP: 2 months

Active acne SYSTEM: IPL 400-1200 nm filter SKIN TYPE 2 AREA: forehead SPOT SIZE: 4.8x1.3 cm EV. FLUENCE: 7 J/Cm2 FREQUENCY: 0.5 Hz SESSIONS: 5 FOLLOW UP: 2 months

One System with four different wavelengths The Clinic in a System dermatology platform One System with four different wavelengths Long Pulse Alexandrite 755 nm for HAIR REMOVAL Long pulse Nd:YAG 1320 nm for SKIN REJUVENATION Long Pulse Nd:YAG frequency doubled 1064 + 532 nm for VASCULAR LESIONS and HAIR REMOVAL in dark skin IPL Extension for MAXIMUM FLEXIBILITY of use

Power level at the top of the category Four wavelengths. One solution!

Thank you!