G GE Power Management MMII Intelligent MCC Controller.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
سیستم آلارم دیجیتالی مجهز به ثبات خطا
Pride in Workmanship Worldwide Pride in Workmanship Worldwide.
Emergency Transfer Controls
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
IntegraPower Features and Models. L1L2L3 T1T2T3 RS-232 cable to PC TB1 connections: Remote ON/OFF Remote indicator light Y-  Control Bypass contactor.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
A Motor Management System for Low Voltage Motor Control
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
WELCOME. Controllers Controller 1/32 DIN FKS SMART function for the self-tuning of control parameters. TC, RTD or linear input programmable. Dual Outputs,
E VERY L IFE H AS A P URPOSE… Flame Detection Theory.
SYMAP-BC SYMAP-BC.
Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy.
EUT 1040 Lecture 10: Programmable Logic Controllers.
M Family Industrial Systems 1 M Family relays provide economical & reliable digital protection, metering, control and monitoring in an integrated package.
PLC OPERATION & PROGRAMMING Dr. ONUR TOKER. What is a PLC ? PLC is a computer system controlling a process. inputs - the keyboard is analogous to a proximity.
Introducing GAC’s New Line of Intelligent Generator Set Controllers
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
Chapter 8 Output Modules.
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
Make the most of your energy December 2008 PowerLogic Enercept Submetering ….when space is at a premium PowerLogic® Enercept Meter.
MIG II DIGITAL FEEDER PROTECTION
Chapter 7 SYSTEM PROTECTION
MP-3000 Motor Protection.
Motor Protection for this Millennium
G GE Power Management 369 Motor Management Relay.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
1 Industrial Systems A dvanced L ine P rotection S ystem.
Install IntelSteer Power Saver Device
SCADA and Telemetry Presented By:.
G650 Generator Protection & Control System
© 2006, ZTE Corporation. All rights reserved.   E300 Series Mini-type Integrated Universal Inverter.
FG Wilson Access 4000 Control Panel
Smart transmitters.
1 Chang Shuan Eletronics Co., Ltd
LDA Large Display for Analog Inputs. Agenda What is the LDA? Easy programming About the input Setpoint control Communication Other features Packaging.
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
The PAX Lite: PAX quality at a great low price.. PAX Lite Series Indication and Setpoint Control Simple field set-up Perfect the low-cost meter users.
VS mini J7 COMPACT INVERTER FOR GENERAL USE
3-Phase Submersible Motor Control
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
SmartMQn Motor Horner APG, LLC September 9, 2008.
Motor. What Does it Do? Monitors three phase motors for a number of current, temperature, estimated power and timing parameters. Provides motor protection.
Franklin Electric - The Company You Trust Deep Down Provides The Ultimate Protection for Your Pump & Motor! Franklin SubMonitor.
CUE – Make Any Pump an E-Pump
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
1 Chang Shuan Electronics Co., Ltd
SmartMQn Motor Protective Functions Ken Jannotta Jr. Horner APG, LLC.
© 2015 Eaton. All Rights Reserved. Motor Protection & Communication for Critical Loads Darrell Ouellette Technology Application Specialist.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
G GE Power Management 269Plus Motor Management Relay.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 HighPROTEC-2 MRI4-2 Feeder Relay Sales presentation 2015/08/10.
M20 Shaft Power Monitor PRODUCT TRAINING. Topics 1.What is an M20 Shaft Power Monitor 2.How does it measure Shaft HP 3.Benefits of Shaft Power measurement.
TPS - Thyristor Power Supply for Resistive/Inductive Loads
GROUND-FAULT GROUND-CHECK MONITOR
FEEDER PROTECTION UNIT
MPU-16A MOTOR PROTECTION UNIT.
MPU-16A / FPU-16 TEST UNIT TUTORIAL
Protection Philosophy
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
ACOE347 – Data Acquisition and Automation Systems
PowerLogic™ offer for the basic metering market
Presentation transcript:

g GE Power Management MMII Intelligent MCC Controller

g GE Power Management MMII Intelligent MCC Controller A concept that will offer reduced overall installed cost and production efficiency through information availability to operators and maintenance.

Presentation Overview g GE Power Management MMII Intelligent MCC Controller Presentation Overview Applications User Interface Protection and Control Communications Inputs Typical Wiring Metering and Monitoring Ordering

g GE Power Management MMII Intelligent MCC Controller Applications In one package the Motor Manager II (MMII) combines control functions and comprehensive motor protection, providing sophisticated control and protective relaying. Low voltage motor control centers Integrated process and electrical control MAIN

g SINGLE LINE DIAGRAM GE Power Management Application MAIN Legend 52 51 49 37 46 51G 59 27 CONTACTOR A (FORWARD/WYE) CONTACTOR B (REVERSE/DELTA) AUX 1 RELAY AUX 2 PROCESS PLC OR TRANSDUCER CONTROL INPUTS 4 - 20mA INPUT MOTOR MANAGER II 480 VOLTS BUS FUSE CONTACTOR PHASE PT PHASE CT GROUND CT WINDING THERMISTOR RS485 REMOTE COMMUNICATION 1200-19K2 BAUD LOAD SINGLE LINE DIAGRAM Legend MAIN

g GE Power Management Application MAIN 49/51 overload DEVICE PROTECTION 49/51 overload 46 phase unbalance (single phase) welded/open contactor 50G/51G ground fault 48 locked rotor/stalled rotor 49 hot winding (thermistor) 37 undercurrent/under power 27 undervoltage 59 overvoltage STANDARD PROTECTION OPTION 2 ENHANCEMENT MAIN

g Protection Overload Phase unbalance Contactor failure GE Power Management MMII Intelligent MCC Controller Protection Overload Phase unbalance Contactor failure Locked/stalled rotor Ground fault Hot winding thermistor Undercurrent/underpower MAIN

time/current overload g GE Power Management Protection 100000 10000 4 NEMA compatible time/current overload curves 1000 TIME IN SECONDS 100 CURVE # CLASS 30 CLASS 20 10 CLASS 15 CLASS 10 MAIN 1 0.1 0.5 1 2 3 4 5 6 7 8 9 10 20 50 100 MULTIPLE OF PICKUP CURRENT (PER UNIT)

g Control Undervoltage auto restart GE Power Management MMII Intelligent MCC Controller Control Undervoltage auto restart Outputs (assignable to any one of 31 functions) 2 contactor (A and B) 2 programmable Inputs: 6 fixed, 10 programmable 1 analog input MAIN

g Inputs Switched Inputs Switched Inputs GE Power Management MMII Intelligent MCC Controller Inputs Switched Inputs up to 6 fixed control inputs used for start A and B, stop, local isolator, and contactor A and B status. Switched Inputs scaleable to user defined values high and low alarm and trip setpoints recorded with time delays MAIN

g Metering The MMII meters and displays: GE Power Management MMII Intelligent MCC Controller Metering The MMII meters and displays: RMS current of each phase ground fault leakage current motor load as a % of full load current thermal capacity used (%) according to I2t history and chosen overload curve; hot/cold ratio is used to model heating when running below full motor current % unbalance power (kW) energy (kWh) voltage analog input MAIN

g Monitoring Trip Record Statistics and Maintenance GE Power Management MMII Intelligent MCC Controller Monitoring Trip Record when a trip command is issued, a trip record is generated, including the cause of trip and pre-trip actual values Statistics and Maintenance user enabled to set the interval at which a number of routine maintenance tasks should be performed. When these times are exceeded an alarm is generated, including: motor greasing interval contactor inspection maximum motor stopped time MAIN

g User Interface RS485 ModBus®, 1200 - 19,200 bps GE Power Management MMII Intelligent MCC Controller User Interface RS485 ModBus®, 1200 - 19,200 bps Display model for local interface Up to 11 status LEDs MMII PC Software

g User Interface The Chassis Mount Model GE Power Management MMII Intelligent MCC Controller User Interface The Chassis Mount Model mounted inside the motor control center (MCC) comes with all standard features setpoints are loaded through the RS485 communications port from a personal computer running the MMII program. MAIN

g MMIIPC Software Windows based software GE Power Management User Interface MMIIPC Software Windows based software Windows 95 or Windows NT Features: program or modify setpoints load or save setpoints from or to a disk read actual values from the MMII monitor status read pre-trip data and trip record display dynamic trending of actual values get help on any topic print the instruction manual from disk MAIN

g GE Power Management Front View MAIN DISPLAY: 2 line, 40 character illuminated display communicates all messages in simple English for easy interpretation by users unfamiliar with unit RELAY INDICATORS: RELAY A: Contactor A energized RELAY B: Contactor B energized AUX 1: User programmable relay 1 energized AUX 2: User programmable relay 2 energized PROGRAM KEYS: ACTUAL VALUES: Press to enter actual values mode to display actual motor values such as current, ground leakage, thermal capacity. SETPOINTS: Press to enter setpoint mode to alter or examine setpoints. STORE: Save a newly entered setpoint. RESET: Reset the MMII after a trip. MESSAGE: Move to the desired setpoint or actual value message. VALUE: Increment or decrement currently displayed setpoint value. MAIN

g GE Power Management Front View MAIN CONTROL KEYS: AUTO: Selects operation of start via communication port. MANUAL: Selects manual operation of motor using start key. START A: Energize contactor A. START B: Energize contactor B. STOP: De-energize contactors. STATUS INDICATORS: RUNNING: Contactor is energized and motor is running. STOPPED: Contactor is not energized and motor is not running. TRIPPED: Contactor is not energized. Motor is not running. The MMII has tripped the motor due to a fault. Normally a cause of trip message will be displayed. ALARM: One or more alarm conditions are present. Normally a cause of alarm message will be displayed. FAULT: An internal fault or abnormal condition has been detected. The MMII may need to be replaced or serviced. MAIN

g GE Power Management Rear View MAIN COMMUNICATIONS RS485 2 wire serial communication port operates at 1200 - 19,200 bps for remote commands, monitoring and setpoint store. ModBus® RTU protocol. SWITCH INPUTS Opto-isolated 120 VAC live inputs for various interlock functions. The interlock inputs are fully programmable and can be assigned to such functions as setpoint access, plant interlock, test, and various others. CONTROL POWER 120/240 VAC supply voltage selector switch and fuse access door 4 RELAYS Contactor A: direct on line / forward / wye Contactor B: reverse / delta User programmable relay (AUX 1) User Programmable relay (AUX 2) SUPPLY VOLTAGE required to power the MMII MAIN

g GE Power Management Rear View MAIN Ground safety and surge ANALOG INPUT 4 - 20mA input for process control monitoring / alarming / tripping. VOLTAGE INPUT Phase A voltage input for voltage and power monitoring. THERMISTOR NTC or PTC thermistor input for hot winding detection. GROUND CT INPUT 5 amp or 50:0.025 ground fault input for residually connected phase CTs or separate core balance (zero sequence) CT. PHASE CT INPUTS 3 isolated phase CT inputs that accept 1 amp or 5 amp CT. MAIN

g Communication ModBus® RTU RS485 connection GE Power Management MMII Intelligent MCC Controller Communication ModBus® RTU RS485 connection Up to 32 MMIIs can be daisy chained together on a single communication channel. supports operation at 1200 to 19,200 bps MAIN

g Typical Wiring GE Power Management MMII Intelligent MCC Controller Residual Ground Connection Two Phase CT Connection Direct Connection CT PHASE A CT PHASE A CT PHASE B CT PHASE C CT PHASE C PART 2 OF DIAGRAM MAIN

MAIN MOTOR MANAGER II 4-20mA Analog Input RS485 Stator Thermistor Stop Core Balance (Zero Sequence) Isolater Switch Contactor CT Phase A CT Ground CT Phase B CT Phase C L1 L1 L2 L2 MOTOR L3 L3 4-20mA Analog Input RS485 Programmable Switch Inputs Stator Thermistor Stop MOTOR MANAGER II Start Fixed Switch Inputs = Option 1: Process control = Option 2: Enhanced protection A MCC Ground Bus Contactor A L AC Control Voltage 120 / 240 VAC MAIN N

g Ordering GE Power Management MMII Intelligent MCC Controller MAIN MMII Basic Unit PD Panel Mount With Display * C Chassis Mount (Black Box) 1 Option 1 Process control, process input, undervoltage auto restart, diagnostics 2 Option 2 Enhanced protection, power (kW), thermistor, 2nd contactor control 120 Control voltage 120 VAC 240 Control voltage 240 VAC MAIN

g GE Power Management Accessories: Modifications: Ordering MAIN MMIIPC software package supplied free RS232 TO RS485 CONVERTER box designed for harsh industrial environments 5A PHASE CT: 50, 75, 100, 150, 200, 250, 300, 350, 400, 500, 600, 750, 1000 1A PHASE CT: 50, 75, 100, 150, 200, 250, 300, 350, 400, 500, 600, 750, 1000 50:0.025 GROUND CT for sensitive ground detection on high resistance grounded systems COLLAR for reduced depth mounting Modifications: MOD601: 240 VAC switch inputs - allows the use of external 240 VAC supply to power switch inputs MOD602: 24 - 48 VDC switch inputs - allows the use of external 24 - 48 VDC supply to power switch inputs MOD603: ESD relay - converts AUX 2 relay into an emergency shutdown relay MOD605: Removable rear terminals - allows terminals 13 - 58 to be unplugged from the MMII MOD610: Conformal coating MOD613: 240 VAC VT input MOD616: MMII with remote display MAIN

g GE Power Management MMII Intelligent MCC Controller