Tissue inhomogeneities in Monte Carlo treatment planning for proton therapy L. Beaulieu 1, M. Bazalova 2,3, C. Furstoss 4, F. Verhaegen 2,5 (1) Centre.

Slides:



Advertisements
Similar presentations
The Vin č a Institute of Nuclear Sciences, Belgrade, Serbia * Universita degli studi di Bologna, DIENCA, Italia Radovan D. Ili}, Milan Pe{i}, Radojko Pavlovi}
Advertisements

1 Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration Joonki Noh, Jeffrey A. Fessler EECS Department, The University.
Energy deposition and neutron background studies for a low energy proton therapy facility Roxana Rata*, Roger Barlow* * International Institute for Accelerator.
Photon Beam Monitor-Unit Calculations
Dose Calculations A qualitative overview of Empirical Models and Algorithms Hanne Kooy.
The Use of Computed Tomography Images in Monte Carlo Treatment Planning Magdalena Bazalova PhD defense.
MONTE-CARLO TECHNIQUES APPLIED TO PROTON DOSIMETRY AND RADIATION SAFETY F. Guillaume, G. Rucka, J. Hérault, N. Iborra, P. Chauvel 1 XXXV European Cyclotron.
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods
Building clinical Monte Carlo code from Geant4, PENELOPE or EGSnrc Joao Seco 1, Christina Jarlskog 1, Hongyu Jiang 2 and Harald Paganetti 1 1 Francis H.
Radiation Exposure, Dose and Relative Biological Effectiveness in Medicine Background Image:
Reduced Dose of Proton CT Compared to X-Ray CT in Tissue-Density Variation Sensitivity T. Satogata, T. Bacarian, S. Peggs, A.G. Ruggiero, and F.A. Dilmanian.
Emily Poon Frank Verhaegen March 6, 2006
Interactions of charged particles with the patient I.The depth-dose distribution - How the Bragg Peak comes about - (Thomas Bortfeld) II.The lateral dose.
Vertex2002 pCT: Hartmut F.-W. Sadrozinski, SCIPP Initial Studies in Proton Computed Tomography L. R. Johnson, B. Keeney, G. Ross, H. F.-W. Sadrozinski,
MONTE CARLO RADIATION DOSE SIMULATIONS AND DOSIMETRY COMPARISON OF THE MODEL 6711 AND I BRACHYTHERAPY SOURCES Mark J. Rivard Department of Radiation.
An algorithm for metal streaking artifact reduction in cone beam CT M. Bazalova 1,2, G. Landry 1, L. Beaulieu 3, F. Verhaegen 1,4 1-McGill University,
tomos = slice, graphein = to write
At the position d max of maximum energy loss of radiation, the number of secondary ionizations products peaks which in turn maximizes the dose at that.
Electron Beams: Physical Principles and Dosimetry
BIOLOGICAL EFFICIENCY OF A THERAPEUTIC PROTON BEAM: A STUDY OF HUMAN MELANOMA CELL LINE I. Petrović 1, A. Ristić-Fira 1, D. Todorović 1, L. Korićanac 1,
Department of Radiation Oncology and BIO-X, School of Medicine Stanford University Molecular Imaging Program at Stanford MIPS Monte Carlo treatment planning.
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Dose Distribution and Scatter Analysis
Evaluation of New Pre-Treatment In-Air Patient Specific QA Software for TomoTherapy Treatments Lydia L. Handsfield¹, Quan Chen¹, Kai Ding¹, Wendel Renner²,
PAMELA Contact Author: CONFORM is an RCUK-funded Basic Technology Programme Charged Particle Therapy Treating cancer with protons and light ions Ken Peach,
Научно-практический центр протонной лучевой терапии и радиохирургии (Москва-Дубна) A SYSTEM FOR MEASUREMENT OF A THERAPEUTIC PROTON BEAM DOSE DISTRIBUTION.
Patient Plan Results: Table 3 shows the ratio of the Pinnacle TPS calculation to the DPM recalculation for the mean dose from selected regions of interest.
Test of the proposed method Introduction CCD Controller CCD Illuminator gel Filter 585nm Assembling the phantom before its irradiation. The phantom, ready.
TÍTULO DO TRABALHO NOMES DOS AUTORES ENDEREÇOS E DOS AUTORES INTRODUTION Gammacell 220 Series 39 is a irradiation device purchased by CDTN/CNEN in.
Applications of Geant4 in Proton Radiotherapy at the University of Texas M.D. Anderson Cancer Center Jerimy C. Polf Assistant Professor Department of Radiation.
Geant4 Collaboration workshop Layered Mass Geometry Improvements for Brachytherapy Applications Shirin A. Enger, Michel D'Amours Université Laval Centre.
O AK R IDGE N ATIONAL L ABORATORY U. S. D EPARTMENT OF E NERGY 1 Radiation Treatment Planning Using Discrete Ordinates Codes R. N. Slaybaugh, M. L. Williams.
Preliminarily results of Monte Carlo study of neutron beam production at iThemba LABS University of the western cape and iThemba LABS Energy Postgraduate.
G. Bartesaghi, 11° ICATPP, Como, 5-9 October 2009 MONTE CARLO SIMULATIONS ON NEUTRON TRANSPORT AND ABSORBED DOSE IN TISSUE-EQUIVALENT PHANTOMS EXPOSED.
Bragg Peak By: Megan Whitley. Bragg Peak  Bragg Peak is the characteristic exhibited by protons that makes them SO appealing for cancer treatment. 
Ian C. Smith 1 A portal-based system for quality assurance of radiotherapy treatment plans using Grid-enabled High Performance Computing clusters CR Baker.
MRI SIMULATION FOR CONFORMAL RADIATION THERAPY OF PROSTATE CANCER Pasquier D 1-3, Palos G 3, Castelain B 1, Lartigau E 1,2, Rousseau J 2,3 1 Department.
Medical Accelerator F. Foppiano, M.G. Pia, M. Piergentili
1 Everyday Statistics in Monte Carlo Shielding Calculations  One Key Statistics: ERROR, and why it can’t tell the whole story  Biased Sampling vs. Random.
1 Radiotherapy, hadrontherapy and treatment planning systems. Faiza Bourhaleb INFN-Torino University Med 1er-Morocco  Radiotherapy  Optimization techniques.
The production of X-Rays X-Rays are produced whenever charged particles are slowed down or stopped. X-rays are generated via interactions of the accelerated.
Bone Mineral Density Math
F. Foppiano, M.G. Pia, M. Piergentili
Outline Intro: voxel phantom + MCNPX Building geometry
P. Rodrigues, A. Trindade, L.Peralta, J. Varela GEANT4 Medical Applications at LIP GEANT4 Workshop, September – 4 October LIP – Lisbon.
If information seems to be missing, make any reasonable assumptions. 1.A target has an areal density of 2.3 g/cm 2 and a thickness of 0.8 inch. What is.
Implementation of a New Monte Carlo Simulation Tool for the Development of a Proton Therapy Beam Line and Verification of the related Dose Distributions.
Interaction of x-ray photons (and gamma ray photons) with matter.
Thickness of CZT detector 110 MeV140 MeV DETECTOR A (1 mm CZT + 5 mm CZT) DETECTOR B (1 mm CZT + 10 mm CZT) DETECTOR C (1 mm CZT + 15 mm CZT) A. Generation.
Dae-Hyun Kim Dept. of Biomedical Engineering The Catholic University of Korea Department of Biomedical Engineering Research Institute.
The Effects of Small Field Dosimetry on the Biological Models Used In Evaluating IMRT Dose Distributions Gene Cardarelli,PhD, MPH.
Development of elements of 3D planning program for radiotherapy Graphical editor options  automated enclose of contour  correction of intersections 
J Cho, G Ibbott, M Kerr, R Amos, and O Mawlawi
J Cho, G Ibbott, M Gillin, C Gonzalez-Lepera, U Titt and O Mawlawi
INTERCOMPARISON P3. Dose distribution of a proton beam
Electron Beam Therapy.
Dose Profiler simulation update
Study of dental prostheses influence in radiation therapy
Development and characterization of the Detectorized Phantom for research in the field of spatial fractionated radiation therapy. D. Ramazanov, V. Pugatch,
A Brachytherapy Treatment Planning Software Based on Monte Carlo Simulations and Artificial Neural Network Algorithm Amir Moghadam.
Arghya Chattaraj, T. Palani Selvam, D. Datta
Implementation of Object Spot Avoidance in Proton Pencil Beam Treatment on Whole Breast with Implant Metal Injector Peng Wang, PhD, DABR, Karla Leach,
Applications of Dual-Energy Computed Tomography for the Evaluation of Head and Neck Squamous Cell Carcinoma  Reza Forghani, MD, PhD, Hillary R. Kelly,
Physics and Imaging in Radiation Oncology
Physics and Imaging in Radiation Oncology
Design of A New Wide-dynamic-range Neutron Spectrometer for BNCT with Liquid Moderator and Absorber S. Tamaki1, I. Murata1 1. Division of Electrical,
P. Rodrigues, A. Trindade, L.Peralta, J. Varela
On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems  Nick Reynaert, Frederik Crop, Edmond Sterpin, Iwan Kawrakow,
Structure delineation in the presence of metal – A comparative phantom study using single and dual-energy computed tomography with and without metal artefact.
Presentation transcript:

Tissue inhomogeneities in Monte Carlo treatment planning for proton therapy L. Beaulieu 1, M. Bazalova 2,3, C. Furstoss 4, F. Verhaegen 2,5 (1) Centre Hospitalier Univ de Quebec, Quebec, QC, CA, (2) McGill University, Montreal, QC, CA, (3) Stanford University, Stanford, CA, (4) Hopital Maisonneuve-Rosemont, Montreal, QC, CA, (5) Maastro Clinic, Maastricht, NL Proton therapy is gaining popularity in the treatment of cancer and the need for an accurate treatment planning system is obvious. Monte Carlo (MC) dose calculation, despite the relatively long computation time, is the most accurate way to determine the dose delivered to the patient during radiation therapy. Whereas MC dose calculations for conventional photon and electron radiotherapy have been studied extensively, proton beam MC dose calculations have only recently received attention. In this work, the importance of tissue segmentation in proton therapy is investigated using dual-energy CT (DECT) imaging. Another challenge in MC dose calculation treatment planning is metal streaking CT artifacts with the associated tissue and mass density miss-assignment. Their effect on MC proton beam dose calculations is studied for a prostate patient with bilateral hip prostheses. Introduction Tissue segmentation with dual-energy CT: CT images of a 30 cm diameter cylindrical phantom with 9 tissue equivalent inserts (table1, fig 1a) were segmented into material and mass density maps using single- energy CT (fig 1b) and DECT (fig 1c) material extraction. DECT tissue segmentation can distinguish materials with similar relative electron densities ρ e having different effective atomic numbers Z eff. The effect of inaccurate material segmentation for the two soft bone equivalent materials (B200 and CB2-10) and an adipose-equivalent material (PE) with the commonly used single energy CT material segmentation was studied. A left lateral 16×16 cm MeV proton beam was simulated in the MCNPX code. The mass densities for (1.9×1.9×20) mm 3 voxels were binned into 0.1 g/cm 3 bins. The dose was calculated for the exact geometry (D exact ), the single energy CT geometry (D single ) and the dual- energy CT geometry (D dual ). Materials and Methods Metal streaking artifacts: The effect of metal streaking artifacts and their correction based on sinogram interpolation on MC proton beam dose calculations was studied on a patient with bilateral hip prostheses. Dose calculations were performed for three different simulation geometries: considering only tissue of uniform density 1 g/cm 3 (the water-only geometry), and using a CT number to material and mass density calibration curve with original CT images containing streaking artifacts and with artifact corrected CT images. A treatment plan with two 147 MeV proton beams (45° and 315°) was simulated in the MCNPX code. First, the spread-out Bragg peak (SOBP) was designed using simulations in a uniform water phantom (fig 2a). It is impossible to model a modulator wheel in the MCNPX code, and therefore the steps of the modulator wheel were approximated by 5 mm thick PMMA blocks. In order to calculate the dose distribution of the SOBP in the patient in a single MC simulation, 11 PMMA blocks were inserted in the path of the (6×6) cm 2 beams and the source particles (147 MeV protons) were sampled with their respective weights from the volume between the blocks (fig 2b). The patient CT images with (1.9×1.9×20) mm 3 voxels were segmented into 4 materials (air, tissue, bone and steel) using 0.1 g/cm 3 mass density bins. Tissue segmentation with dual-energy CT: Fig 3 presents the results of the phantom study. The exact dose distribution is shown in fig 4a and the differences from D single and D dual are presented in fig 3b and 3c, respectively. In both D single and D dual, the position of the Bragg peak is shifted with respect to the true position of the Bragg peak. The shift is 0.7 cm for D single and 0.7 cm or less for D dual. This is possibly due to mass density differences in the single energy CT and DECT geometry from the exact geometry. Fig 3d demonstrates the dose calculation error in the miss-assigned B200 soft bone tissue equivalent insert. The dose in the B200 insert was by 2% lower than in the exact and DECT geometry. Metal streaking artifacts: The dose distributions calculated based on the water-only geometry, on the original CT geometry and the artifact corrected geometry are presented in fig 4. The shape of the 80% isodose line conforms to the prostate in the water-only dose calculation (fig 4a). Results The dose distribution is significantly distorted in the original CT geometry due to the artifacts (fig 4b). The apparent air between the prostheses results in inaccurate doses with large statistical errors. Additionally due to the air, the 20% and 30% isodose lines extend by 1.5 cm in the healthy tissue. This might cause problems in treatment planning and its optimization. The artifact corrected geometry produced a dose distribution similar to the water-only dose distribution (fig 4b). The true dose distribution is not known. Figure 3: The exact dose distribution (D exact ) using a 200 MeV proton beam (a). PDD with two inhomogeneities (SB3 and B200) (b), the 2% dose calculation error is indicated by the arrow. The dose differences from D exact for D single (c) and D dual (d). The shift in the Bragg peak demonstrates the need for careful mass density assignment in MC dose calculations for proton beams. The dose calculation errors using the conventional single-energy CT tissue segmentation below 2% suggest that the use of DECT for proton dose calculations might only have a small added benefit. The patient study shows that a metal artifact correction is necessary for patients with bilateral hip prostheses. Conclusions Figure 4: Dose distribution for a prostate patient calculated on the basis of homogeneous water geometry (a), on the basis on the geometry with metal artifacts (b) and using the artifact correct images (c). The arrows indicate the apparent range of protons due to artifacts. MATERIALρeρe Z eff lung (LN300) lung (LN450) polyethylene (PE) CT Solid Water (SW) B200 bone mineral CB2 - 10% CaCO CB2 - 30% CaCO CB2 - 50% CaCO SB3 cortical bone Figure 1: Figure 1: The exact geometry (a), the single-energy material segmentation (b) and the dual-energy CT material segmentation (c). Table 1:Relative electron densities ρ e and effective atomic numbers Z eff for materials used in the tissue inhomogeneity study. a) b) All CT geometries were converted into lattices and the dose was scored using the *F8:H,P,E energy deposition tally. Protons, photons and electrons were transported using the la150u cross section library with energy cutoffs of 10 keV. In all simulations, 107 particles were simulated in approximately 15 hours on a 3 GHz machine. Figure2: The spread-out Bragg peak for patient dose calculations (a) and the MCNP geometry showing 0.5 cm PMMA blocks for modulation of the 147 MeV proton beam (b). c) a)b) d) a) b)c)